Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow resistance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Membrane-Based Air Dehumidification Using Organic Ionic Liquid Desiccant

Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Electrochemical CO 2 Utilization: Scalable System Operation for Formic Acid Production

In recent years, research into the electrochemical reduction of CO 2 has grown exponentially. Formic acid (FA) has become a particular value product from CO 2 due to its versatility [1], optimal atom economy [2], and thermodynamic favorable [3]. FA can be produced electrochemically via a direct two-electron transfer process involving CO 2 with a proton source, requiring less energy input and fewer reaction steps than the conventional Kemira process. However, product selectivity, electrode stability, and low faradic efficiency due to increased resistance under constant current, remain key issues for CO 2 reduction to FA [4]. University of Kentucky’s Center for Applied Energy Research (UK CAER) is currently investigating reactor designs to address the challenges associated with electrochemical CO 2 conversion to FA [5]. The current reactor system employs: (1) an organic-based charge carrier which shuttles charge directly to the catalyst to enable CO 2 reduction to FA; (2) novel electrode materials to mitigate large voltages and improve conductivity; and (3) a flow system which not only allows for the volumetric scale-up of both charge carrier and catalyst, but also decouples the charger carrier re-energized and FA production processes to protect the catalyst’s stability due to overpotential. Through careful adjustment of electrode, charge carrier, and electrolyte selection, cell resistances have decreased by over 15%, facilitating conduction necessary for effective CO 2 reduction to FA. The system uses a highly specific engineered catalyst, which has produced over 100 mM FA at a rate of over 10 mM FA/hour following the aforementioned electrode/charge carrier changes. System design considerations (flow rate, bulk volume) and modeling of the system will also be discussed.

20 FOSSIL-FUELED POWER PLANTS↗

Some observations concerning "laminarization" in heated vertical tubes

For low "turbulent" Reynolds numbers in strongly-heated vertical gas flow, fundamental results of existing direct numerical simulation (DNS) databases have been examined to deduce differences between cases which "revert" to turbulent and those that yield integral parameters which correspond to laminar flow (henceforth laminarizing or laminarized). The objectives of this paper are (1) to examine the streamwise evolution of near-wall flow structures and (2) to determine which, if any, proposed laminarization parameters could be used to discriminate between turbulent and laminarizing flows resulting. Views of streamlines in r-θ cross sections showed evidence of a ring of irregular-shaped streamwise vortices near the wall at all locations. The transverse advection of these vortices is hypothesized to provide a path of least resistance to the transport of streamwise momentum in the wall-normal direction. It is demonstrated that a steady streamwise laminar vortex can provide apparent turbulent momentum transport (as a consequence of the Reynolds decomposition) such that a reasonable mean velocity profile is predicted near the wall. For the present cases, the values of the non-dimensional radius (y c,w + = Re τ,w ) and of the modified wall Reynolds number did discriminate whether turbulent or laminarizing flow resulted.

99 GENERAL AND MISCELLANEOUS↗

Zero-Valent Iron Permeable Reactive Barrier to Remediate Volatile Organic Compounds in Groundwater - 20209

The US DOE-SRS, the US EPA, and the South Carolina Department of Health and Environmental Control determined it was appropriate to perform a non-time critical removal action at the P-Area Groundwater Operable Unit at the SRS to reduce the mass and downgradient transport of trichloroethylene in the P-Area groundwater plume. Contaminated groundwater discharges to a nearby stream, Steel Creek, within the SRS boundaries, resulting in trichloroethylene concentrations above the maximum contaminant level. Impact to surface water is limited in areal extent and supported by recently collected characterization data. The P-Area Groundwater Operable Unit encompasses the groundwater beneath an industrial area within SRS, P Area, where the P-Reactor once operated. The boundaries of the P-Area Groundwater Operable Unit extend northwest to Steel Creek, northeast toward PAR Pond, and southeast to Meyers Branch. Groundwater in the Upper Three Runs Aquifer of the P-Area Groundwater Operable Unit has been impacted by reactor and facility operations between 1954 and 1991, including tritium and volatile organic compounds. The P-Area surface units contributing to groundwater contamination were remediated as part of the P-Area Operable Unit in 2011. The P-Reactor closure is one of the first of its kind in the DOE Complex and is one of only a few full-sized production reactors in the US to undergo completion of final closure activities. The nature and extent of groundwater contamination was determined using a variety of investigative approaches such as groundwater monitoring wells, direct-push technology, and surface water samples. Groundwater contamination associated with trichloroethylene is primarily exhibited in a narrow plume that extends from the source area at P-Reactor and west to Steel Creek. Maximum contaminant level exceedances in groundwater occur over an area of ∼6.9 hectares for trichloroethylene with concentrations as high as 7.7 milligrams per liter. To the west of the P-Area facility area, the trichloroethylene groundwater plume is controlled by a buried geologic feature, assumed to be an old stream bed, that further narrows the groundwater plume in what has been designated as the 'neck area.' This narrowing of the groundwater plume provides an ideal location for a treatment barrier. The non-time critical removal action alternative chosen is to install a zero-valent iron permeable reactive barrier within the neck area of the trichloroethylene groundwater plume, perpendicular to groundwater flow direction. This technology will provide a treatment barrier that will reduce trichloroethylene groundwater concentrations by 90% and has an anticipated useful life of at least 25 years. A pre-design investigation was performed in the neck area to confirm site lithology, hydrogeology, geochemistry, and extent of trichloroethylene contamination prior to a final design. A treatability study, conducted as part of the pre-design investigation, indicated that the subsurface and groundwater in the PArea Groundwater Operable Unit is compatible with the zero-valent iron and will not lead to excessive buildup from mineralization/precipitation or biofouling. Probabilistic modeling was conducted using field and laboratory data to determine the expected performance of the zero-valent iron permeable reactive barrier. The model simulations indicated that a 3.81-centimeter thick barrier would provide greater than 90% reduction of trichloroethylene groundwater concentration. The final design of the zero-valent iron permeable reactive barrier is a barrier that will extend 80.5 linear meters in a 'zigzag' orientation to best transect the trichloroethylene plume and account for varying groundwater flow. The barrier will be installed from 13.7 meters below ground surface to 41.1 meters below ground surface for 65.8 linear meters and from 13.7 meters below ground surface to 36.6 meters below ground surface for 14.6 linear meters, the base of which is 'keyed' into a low permeability zone. The barrier is designed to a thickness of 10.2 centimeters, which was determined to reduce the trichloroethylene groundwater concentrations by greater than 90% with a safety factor of 2.67. A total of approximately 689 metric tons of zero-valent iron will be injected through 22 injection wells spaced 3.66 meters apart, using guar to suspend the zero-valent iron. Zero-valent iron permeable reactive barrier construction will be monitored through 23 installed resistivity receivers offset 7.32 meters from the zerovalent iron permeable reactive barrier. The zero-valent iron will be energized with a low-voltage 100 Hertz signal during injection and will be monitored using the resistivity receivers to ensure complete coalescence of the zero-valent iron permeable reactive barrier. The zero-valent iron was sized to have a hydraulic conductivity greater than the natural subsurface, thus promoting groundwater flow through the barrier. As contaminated groundwater contacts the zero-valent iron, volatile organic compounds, including trichloroethylene, are immediately degraded to harmless compounds such as ethylene. The performance of the zero-valent iron permeable reactive barrier will be monitored using three upgradient monitoring well clusters, six downgradient monitoring well clusters, and four in-wall monitoring wells. The in-wall monitoring wells will indicate immediate reduction of trichloroethylene mass in the groundwater and allow analyses of the zero-valent iron permeable reactive barrier health. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Grassland intensification effects cascade to alter multifunctionality of wetlands within metaecosystems

Sustainable agricultural intensification could improve ecosystem service multifunctionality, yet empirical evidence remains tenuous, especially regarding consequences for spatially coupled ecosystems connected by flows across ecosystem boundaries (i.e., metaecosystems). Here we aim to understand the effects of land-use intensification on multiple ecosystem services of spatially connected grasslands and wetlands, where management practices were applied to grasslands but not directly imposed to wetlands. We synthesize long-term datasets encompassing 53 physical, chemical, and biological indicators, comprising >11,000 field measurements. Our results reveal that intensification promotes high-quality forage and livestock production in both grasslands and wetlands, but at the expense of water quality regulation, methane mitigation, non-native species invasion resistance, and biodiversity. Land-use intensification weakens relationships among ecosystem services. The effects on grasslands cascade to alter multifunctionality of embedded natural wetlands within the metaecosystems to a similar extent. These results highlight the importance of considering spatial flows of resources and organisms when studying land-use intensification effects on metaecosystems as well as when designing grassland and wetland management practices to improve landscape multifunctionality.

54 ENVIRONMENTAL SCIENCES↗

Generalized Analysis of Dynamic Flow Fouling on Heat Transfer Surfaces

Several energy applications involve flow of untreated heat transfer fluids that contain trace amounts of mineral salts, such as calcium carbonate and calcium sulfate, which show reverse solubility with temperature. The gradual accretion of these salts onto the heat transfer surfaces causes fouling that degrades thermal performance over time. While fouling of bare surfaces has been extensively studied, fouling of nonwetting superhydrophobic or liquid-infused surfaces is less understood, especially under dynamic flow conditions. This study presents a systematic experimental analysis to elucidate dynamic flow fouling of calcium carbonate and calcium sulfate on smooth, superhydrophobic and liquid-infused surfaces in a generalized manner. Here, copper tubes with modified inner surface wettability are fabricated and subjected to forced convection at different flow rates and fouling salt concentrations. Fouling characteristics of the two salts on the different surfaces are examined through microstructural analysis, and quantified in terms of asymptotic fouling resistance that measures the total extent of fouling, and a threshold time, which correlates to the onset of significant fouling. Using Taguchi design of experiments, the study reports, for the first time, closed-form analytical relationships for the asymptotic fouling thermal resistance and threshold time on the Reynolds number, dimensionless concentration of fouling agent and dimensionless infused liquid viscosity that represents the different surface types in a unified manner. It is shown that the analytical model accurately predicts the fouling characteristics in up to about 97% of the data, based on which contour maps of optimum surface designs for minimizing fouling resistance are presented. The results provide information on designing surfaces for reduced fouling or for estimating the fouling characteristics for a given surface in applications.

36 MATERIALS SCIENCE↗

PFLOTRAN-SIP: A PFLOTRAN Module for Simulating Spectral-Induced Polarization of Electrical Impedance Data

Spectral induced polarization (SIP) is a non-intrusive geophysical method that collects chargeability information (the ability of a material to retain charge) in the time domain or its phase shift in the frequency domain. Although SIP is a temporal method, it cannot measure the dynamics of flow and solute/species transport in the subsurface over long times (i.e., 10–100 s of years). Data collected with the SIP technique need to be coupled with fluid flow and reactive-transport models in order to capture long-term dynamics. To address this challenge, PFLOTRAN-SIP was built to couple SIP data to fluid flow and solute transport processes. Specifically, this framework couples the subsurface flow and transport simulator PFLOTRAN and geoelectrical simulator E4D without sacrificing computational performance. PFLOTRAN solves the coupled flow and solute-transport process models in order to estimate solute concentrations, which were used in Archie’s model to compute bulk electrical conductivities at near-zero frequency. These bulk electrical conductivities were modified while using the Cole–Cole model to account for frequency dependence. Using the estimated frequency-dependent bulk conductivities, E4D simulated the real and complex electrical potential signals for selected frequencies for SIP. These frequency-dependent bulk conductivities contain information that is relevant to geochemical changes in the system. This study demonstrated that the PFLOTRAN-SIP framework is able to detect the presence of a tracer in the subsurface. SIP offers a significant benefit over ERT in the form of greater information content. It provided multiple datasets at different frequencies that better constrained the tracer distribution in the subsurface. Consequently, this framework allows for practitioners of environmental hydrogeophysics and biogeophysics to monitor the subsurface with improved resolution.

54 ENVIRONMENTAL SCIENCES↗

Trace explosive residue detection of HMX and RDX in post-detonation dust from an open-air environment

Explosives are often used in industry, geology, mining, and other applications, but it is not always clear what remains after a detonation or the fate and transport of any residual material. The goal of this study was to determine to what extent intact molecules of high explosive (HE) compounds are detectable and quantifiable from post-detonation dust and particulates in a field experiment with varied topography. We focused on HMX (1,3,5,7-Tetranitro-1,3,5,7-tetrazocane), which is less studied in field detonation literature, as the primary explosive material and RDX (1,3,5-Trinitroperhydro-1,3,5-triazine) as the secondary material. The experiment was conducted at Site 300, Lawrence Livermore National Laboratory’s Experimental Test Site, in California, USA. Two 20.4 kg and one 40.8 kg above ground explosions (primarily comprised of LX-14, an HMX-based polymer-bonded high explosive) were detonated on an open-air firing area on separate days. The complex terrain of the firing area (e.g., buildings, berm, low-height obstacles) was advantageous to study HE deposition in relation to plume dynamics. Three types of samples were collected up to 100 m away from each shot: surface swipes of aluminum plates, surface swipes of fixed objects, and filters from air samples. We used atmospheric flow tube-mass spectrometry (AFT-MS) to quantify picogram levels of molecular residue of HE material in the post-detonation dust. An aliquot of sample extract in methanol (e.g., 1 µL of 0.5 mL) was placed onto a resistive material and then thermally desorbed into the AFT-MS. We successfully detected and quantified both HMX and RDX in many of the samples. Based on mass (pg) detected and solution dilution, we back-calculated the mass collected on the swipe or filter (ng per sample). The aerial distribution of molecular residue was consistent with the path of the plume, which was strongly determined by wind speed and direction at the time of each shot. The quantity of material detected appeared to correlate more with distance from the shot and the wind conditions than with shot size. This study demonstrates that the picogram detection levels of AFT-MS are well-suited for quantification of analytes (e.g., HMX and RDX) in environmental samples.

atmospheric flow tube-mass spectrometry (AFT-MS), ↗

Influence of fine-scale B2 precipitation on dynamic compression and wear properties in hypo-eutectic Al0.5CoCrFeNi high-entropy alloy

The near equiatomic high-entropy alloys based on Al, Co, Cr, Fe, Ni have provided a novel microstructural template for alloy design. The face-centered cubic (FCC) matrix strengthened by body-centered cubic (BCC) based ordered B2 precipitates can be used to develop a new generation of precipitation strengthened alloys. The present study focuses on an Al0.5CoCrFeNi hypo-eutectic alloy consisting of an as-solidified FCC+B2 microstructure. Guided by solution thermodynamic modeling, this alloy has been isothermally aged for solid-state precipitation of a high fraction of fine-scale intragranular B2 particles. The dynamic compressive strength, hardness, and sliding wear response of the alloy as a function of B2 phase fraction is examined. The flow stress at 0.02% true strain increased from ~ 670 MPa to ~1350 (102%) MPa, the ultimate compressive strength increased from ~1160 MPa to 1500 MPa (20%), and the wear resistance increased more than 5 times with progressively increasing phase fraction of B2 precipitates.

Gwalani, Bharat↗

Control of chiral orbital currents in a colossal magnetoresistance material

Colossal magnetoresistance (CMR) is an extraordinary enhancement of the electrical conductivity in the presence of a magnetic field. It is conventionally associated with a field-induced spin polarization that drastically reduces spin scattering and electric resistance. Ferrimagnetic Mn 3 Si 2 Te 6 is an intriguing exception to this rule: it exhibits a seven-order-of-magnitude reduction in ab plane resistivity that occurs only when a magnetic polarization is avoided 1,2 . Here, we report an exotic quantum state that is driven by ab plane chiral orbital currents (COC) flowing along edges of MnTe 6 octahedra. The c axis orbital moments of ab plane COC couple to the ferrimagnetic Mn spins to drastically increase the ab plane conductivity (CMR) when an external magnetic field is aligned along the magnetic hard c axis. Consequently, COC-driven CMR is highly susceptible to small direct currents exceeding a critical threshold, and can induce a time-dependent, bistable switching that mimics a first-order ‘melting transition’ that is a hallmark of the COC state. Further, the demonstrated current-control of COC-enabled CMR offers a new paradigm for quantum technologies.

36 MATERIALS SCIENCE↗

Combining Distributed Electrochemical Measurements with a Semi-Empirical Model to Identify Local Variations in Overpotentials for PEM Water Electrolyzers

Abstract A segmented cell and PCB approach was used to demonstrate an advanced technique for measuring and understanding the electrochemical behavior of PEM water electrolyzers. By employing a semi-empirical model, discrete modes of overpotential and their spatial distributions were identified in an operating cell. Distributed area-specific resistance (DASR measurements indicate that local dehydration of the polymer electrolyte membrane is the primary driver of increased polarization, behaving similarly to mass transport-limited currents at low flow rates due to ineffective gas-phase bubble removal. To improve quantification, the overall ohmic overpotential is divided into background (η Ohm,b ) and mass transport-coupled (η Ohm,mt ) components. Two types of anode diffusion media, a baseline PTL and a thin foil liquid/gas diffusion layer (LGDL), were examined. The results show significant variations in η Ohm,b and highlight that ineffective bubble removal leads to pronounced local dehydration. The effect of cell temperature on various overpotentials was also examined. Negligible differences in diffusion overpotential were observed when comparing PEWE performance using the PTL and LGDL, despite major differences in two-phase fluid transport within each diffusion media. This underscores the critical role of the catalyst layer's micro-porous structure in diffusion processes. The study highlights the complex nature and intricacies of mass transport limitations within PEWEs.

Roy, Anirban (ORCID:0000000163803386)↗

Concurrent evaluation of autophagy induction and Burkholderia infection at the single cell level

Autophagy is a natural, regulated cellular process that "cleans up" cellular debris by degrading and recycling dysfunctional proteins. There is a high potential impact of exploiting the benefits of autophagy to complement existing treatments, but little has been done to date on bacterial pathogens of defense concern such as Burkholderia pseudomallei, a highly virulent Select Agent pathogen that is intrinsically resistant to most classes of antibiotics. Assessment of autophagy in the context of infection typically requires use of multiple technologies in combination (e.g., Western analysis paired with microscopy or flow cytometry) as applied to heterogeneous populations of cells. To address this, we have developed a dual target reporter cell line (RAW264.7 LC3-BFP:mPlum, GFP-RelA) that enables concurrent visualization of infection and autophagy induction. We assessed the effect of clinically approved small molecule inducers of autophagy on infection by Burkholderia thailendensis, a closely related but less virulent surrogate for B. pseudomallei. The reporter cells were first infected with a B. thailendensis strain that constitutively expresses GFP, then treated with one of four known autophagy inducers (rapamycin, niclosamide, bromhexine HC1, or flubendazole) for 4 hours. Confocal fluorescence imaging was used to quantify autophagy stimulation at the single cell level. Autophagy maturation was observed as a decrease in BFP LC3 puncta with a concurrent increase in mPlum LC3 puncta. B. thailendensis infection was assessed by monitoring translocation of GFP-RelA (an NFkB subunit) into the nucleus and through quantitating the intracellular bacterial presence in single cells. Preliminary results indicate that bromhexine HC1 and niclosamide may hinder B. thailendensis' ability to replicate intracellularly and reduce overall bacterial survival.

59 BASIC BIOLOGICAL SCIENCES↗

Advances in the Co-Simulation of Detailed Electrical and Whole-Building Energy Performance

This article describes recent co-simulation advances for the simultaneous modeling of detailed building electrical distribution systems and whole-building energy performance. The co-simulation architecture combines the EnergyPlus® engine for whole-building energy modeling with a new Modelica library for building an electrical distribution system model that is based on harmonic power flow. This new library allows for a higher-fidelity modeling of electrical power flows and losses within buildings than is available with current building electrical modeling software. We demonstrate the feasibility of the architecture by modeling a simple, two-zone thermal chamber with internal power electronics converters and resistive loads, and we validate the model using experimental data. The proposed co-simulation capability significantly expands the capabilities of building electrical distribution system models in the context of whole-building energy modeling, thus enabling more complex analyses than would have been possible with individual building performance simulation tools that are used to date.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Large eddy simulation of lean blow-off in swirl-stabilized flame with the subgrid dissipation concept

The lean blow-off mechanism of the premixed swirl flame is numerically investigated by large eddy simulation (LES) with the subgrid dissipation concept (SDC) combustion model. Three simulated cases cover stable, near blow-off, and transient conditions. Compared with the experiment, the LES-SDC approach captures the flow and combustion features for stable and near blow-off conditions. More importantly, the predictions of the blowoff procedure and duration agree satisfactorily with the experiment, indicating that the LES-SDC approach is a promising tool for predicting strong, unsteady turbulent combustion processes. Further, the numerical results are used to investigate the blow-off mechanism. Two stages in the blow-off procedure are specified. The first is the necking and extinction of the downstream flame surface, and the second is the shrinking of the upstream flame surface. The blow-off mechanism is well explained by the theory of stretched flame extinction. At the end of the recirculation zone, the large negative radial velocity pushes the flame to the central line. The combustion process here can be abstracted as the stretched counter-flame of the reactant-reactant configuration. The excessive flame stretch dominates the flame extinction and triggers the blow-off event. The upstream flame resists the intense stretch with the help of hot product recirculation, and the combustion here can be idealized as the counter-flame of the reactant-product configuration. The alignment of the temperature gradient and flow velocity, together with the excessive stretch, clearly indicates the tendency of flame local extinction. A Damköhler number-based blow-off criterion is raised from the mean flow strain rate and laminar flame bulk extinction strain rate.

42 ENGINEERING↗

Single-Phase Dielectric Fluid Thermal Management for Power-Dense Automotive Power Electronics

This paper describes the design and performance of a dielectric fluid cooling concept for automotive power electronics. The concept combines a low-thermal-resistance package (which eliminates metalized ceramic substrates) with a high-performance convective cooling strategy (slot jets impinging on finned surfaces). Modeling was first used to design the cooling system to maximize thermal performance and minimize pumping power. Additionally, a prototype was then fabricated, and experiments were conducted to validate the model predictions using three fluids at various fluid flow rates (16.7 cm 3 /s [1 L/min] to 68.3 cm 3 /s [4.1 L/min]) and inlet temperatures (30C and 70C). The final design was compact (120-cm 3 total volume, including heat exchanger and conceptual power modules) and cooled 12 devices (e.g., silicon carbide). The validated model was then used to predict the junction-to-fluid thermal resistance and pumping power for various conditions, including 40C fluid temperature. The results predict thermal resistance values as low as 19 mm 2 K/W are possible using the dielectric fluid cooling approach. The dielectric fluid cooling system is predicted to provide thermal resistance and pumping power values that are approximately 56% and 90% lower, respectively, compared to an automotive power electronics cooling system.

30 DIRECT ENERGY CONVERSION↗

Microstructure and strengthening of Al-6Ce-3Ni-0.7Fe (wt%) alloy manufactured by laser powder-bed fusion

In this study, an Al-6Ce-3Ni-0.7Fe (wt%) alloy was fabricated via laser powder-bed fusion and its microstructure, thermal stability, tensile properties, and creep properties are investigated for two rapid-solidification rates with different eutectic spacings. For both faster- and slower-cooled states, the as-fabricated alloy mostly shows elongated grains with very fine eutectic networks (~40 nm lamellar width) comprising a high-volume fraction (~18 %) of intermetallic phases. Faster-cooled samples, however, display a less continuous eutectic network with finer spacing (~100 nm), leading to higher Orowan strengthening and therefore superior microhardness and yield stress up to ~350 °C. Upon aging (300 - 450 °C), micron-size Al 9 (Ni,Fe) 2 needle-like precipitates form within grains, and the Al 11 Ce 3 eutectic network spheroidizes, while retaining a submicron width and spacing, resulting in 33–37 % drop in microhardness after 144 h aging at 400 °C. Limited tensile ductility (~6 %) and creep ductility (~1-2 %) are measured for both faster- and slower-cooled alloys due to an inhomogeneous microstructure, where cavitation preferentially initiates at melt-pool boundaries, precipitate-free zones, and/or denuded zones, eventually leading to local fracture. Denuded zones, induced by stress, form due to diffusional flow with stress-dependent orientations, and are identified as microstructurally weak regions leading to strain localization. The present alloy does not show a significant difference in 300 °C creep resistance between: (i) tensile and compressive loading, (ii) faster- and slower-cooled samples, and (iii) continuous and spheroidized eutectics. Creep resistance at 300 °C is comparable to that of a Ce-richer Al-10.5Ce-3.1Ni-1.2Mn (wt%) alloy, despite the formation of denuded zones and needle-like Al 9 (Ni,Fe) 2 precipitates.

36 MATERIALS SCIENCE↗

Thermomechanical response of thickly tamped targets and diamond anvil cells under pulsed hard x-ray irradiation

In the laboratory study of extreme conditions of temperature and density, the exposure of matter to high intensity radiation sources has been of central importance. Here, we interrogate the performance of multi-layered targets in experiments involving high intensity, hard x-ray irradiation, motivated by the advent of extremely high brightness hard x-ray sources, such as free electron lasers and 4th-generation synchrotron facilities. Intense hard x-ray beams can deliver significant energy in targets having thick x-ray transparent layers (tampers) around samples of interest for the study of novel states of matter and materials’ dynamics. Heated-state lifetimes in such targets can approach the microsecond level, regardless of radiation pulse duration, enabling the exploration of conditions of local thermal and thermodynamic equilibrium at extreme temperature in solid density matter. The thermal and mechanical responses of such thick layered targets following x-ray heating, including hydrodynamic relaxation and heat flow on picosecond to millisecond timescales, are modeled using radiation hydrocode simulation, finite element analysis, and thermodynamic calculations. Assessing the potential for target survival over one or more exposures and resistance to damage arising from heating and resulting mechanical stresses, this study doubles as an investigation into the performance of diamond anvil high pressure cells under high x-ray fluences. Long used in conjunction with synchrotron x-ray radiation and high power optical lasers, the strong confinement afforded by such cells suggests novel applications at emerging high intensity x-ray facilities and new routes to studying thermodynamic equilibrium states of warm, very dense matter.

Meza-Galvez, J. (ORCID:000000032699849X)↗