Search NASA⌕ Search

SEARCH · Search NASA

Results for “Frequency combs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Optical Sidebands Multiplier

Optical sidebands have been generated with relative frequency tens to hundreds of GHz by using optical sidebands that are generated in a cascade process in high-quality optical resonators with Kerr nonlinearity, such as whispering gallery mode (WGM) resonators. For this purpose, the WGM resonator needs to be optically pumped at two frequencies matching its resonances. These two optical components can be one or several free spectral ranges (FSRs), equal to approximately 12 GHz, in this example, apart from each other, and can be easily derived from a monochromatic pump with an ordinary EOM (electro-optic modulation) operating at half the FSR frequency. With sufficient nonlinearity, an optical cascade process will convert the two pump frequencies into a comb-like structure extending many FSRs around the carrier frequency. This has a demonstratively efficient frequency conversion of this type with only a few milliwatt optical pump power. The concept of using Kerr nonlinearity in a resonator for non-degenerate wave mixing has been discussed before, but it was a common belief that this was a weak process requiring very high peak powers to be observable. It was not thought possible for this approach to compete with electro-optical modulators in CW applications, especially those at lower optical powers. By using the high-Q WGM resonators, the effective Kerr nonlinearity can be made so high that, using even weak seeding bands available from a conventional EOM, one can effectively multiply the optical sidebands, extending them into an otherwise inaccessible frequency range.

Strekalov, Dmitry V.↗

A novel photonic oscillator

We report a novel oscillator for photonic RF systems. This oscillator is capable of generating high-frequency signals up to 70 GHz in both electrical and optical domains and is a special voltage-controlled oscillator with an optical output port. It can be used to make a phase-locked loop (PLL) and perform all functions that a PLL is capable of for photonic systems. It can be synchronized to a reference source by means of optical injection locking, electrical injection locking, and PLL. It can also be self-phase locked and self-injection locked to generate a high-stability photonic RF reference. Its applications include high-frequency reference regeneration and distribution, high-gain frequency multiplication, comb-frequecy and square-wave generation, carrier recovery, and clock recovery. We anticipate that such photonic voltage-controlled oscillators (VCOs) will be as important to photonic RF systems as electrical VCOs are to electrical RF systems.

Yao, X. S.↗

Optical synchronization system for femtosecond X-ray sources

Femtosecond pump/probe experiments using short X-Ray and optical pulses require precise synchronization between 100 meter-10 km separated lasers in a various experiments. For stabilization in the hundred femtosecond range a CW laser is amplitude modulated at 1-10 GHz, the signal retroreflected from the far end, and the relative phase used to correct the transit time with various implementations. For the sub-10 fsec range the laser frequency itself is upshifted 55 MHz with an acousto-optical modulator, retroreflected, upshifted again and phase compared at the sending end to a 110 MHz reference. Initial experiments indicate less than 1 fsec timing jitter. To lock lasers in the sub-10 fs range two single-frequency lasers separated by several teraHertz will be lock to a master modelocked fiber laser, transmit the two frequencies over fiber, and lock two comb lines of a slave laser to these frequencies, thus synchronizing the two modelocked laser envelopes.

47 OTHER INSTRUMENTATION↗

Mach-zehnder based optical marker/comb generator for streak camera calibration

This disclosure is directed to a method and apparatus for generating marker and comb indicia in an optical environment using a Mach-Zehnder (M-Z) modulator. High speed recording devices are configured to record image or other data defining a high speed event. To calibrate and establish time reference, the markers or combs are indicia which serve as timing pulses (markers) or a constant-frequency train of optical pulses (comb) to be imaged on a streak camera for accurate time based calibration and time reference. The system includes a camera, an optic signal generator which provides an optic signal to an M-Z modulator and biasing and modulation signal generators configured to provide input to the M-Z modulator. An optical reference signal is provided to the M-Z modulator. The M-Z modulator modulates the reference signal to a higher frequency optical signal which is output through a fiber coupled link to the streak camera.

42 ENGINEERING↗

A comb-sampling method for enhanced mass analysis in linear electrostatic ion traps

In this paper an algorithm for extracting spectral information from signals containing a series of narrow periodic impulses is presented. Such signals can typically be acquired by pickup detectors from the image-charge of ion bunches oscillating in a linear electrostatic ion trap, where frequency analysis provides a scheme for high-resolution mass spectrometry. To provide an improved technique for such frequency analysis, we introduce the CHIMERA algorithm (Comb-sampling for High-resolution IMpulse-train frequency ExtRAaction). This algorithm utilizes a comb function to generate frequency coefficients, rather than using sinusoids via a Fourier transform, since the comb provides a superior match to the data. This new technique is developed theoretically, applied to synthetic data, and then used to perform high resolution mass spectrometry on real data from an ion trap. If the ions are generated at a localized point in time and space, and the data is simultaneously acquired with multiple pickup rings, the method is shown to be a significant improvement on Fourier analysis. The mass spectra generated typically have an order of magnitude higher resolution compared with that obtained from fundamental Fourier frequencies, and are absent of large contributions from harmonic frequency components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave Comb Generator

Stable reference tones aid testing and calibration of microwave receivers. Signal generator puts out stable tones in frequency range of 2 to 10 GHz at all multiples of reference input frequency, at any frequency up to 1 MHz. Called "comb generator" because spectral plot resembles comb. DC reverse-bias current switched on and off at 1 MHz to generate sharp pulses in step-recovery diode. Microwave components mounted on back of special connector containing built-in attenuator. Used in testing microwave and spread-spectrum wide-band receivers.

Sigman, E. H.↗

Laser frequency stabilisation on narrow resonances of cold magnesium atoms at the {sup 1}S{sub 0} – {sup 3}P{sub 1} transition

Experimental studies aimed at developing an optical frequency standard based on ultracold magnesium atoms with a relative uncertainty of Δν/ν < 10{sup –16} are performed. The frequency of the clock laser system at a wavelength of 457 nm is stabilised to narrow optical resonances (Ramsey fringes) in time-separated laser fields interacting with cold magnesium atoms localised in a magneto-optical trap (MOT). The frequency stability of the laser system is investigated using a femtosecond comb based on a Ti:sapphire laser. Long-term frequency stability (determined by the Allan function) of ∼5 × 10{sup –15} at averaging time τ = 1000 s is obtained. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual-comb spectroscopy of laser-induced plasmas

Dual-comb spectroscopy has become a powerful spectroscopic technique in applications that rely on its broad spectral coverage combined with high frequency resolution capabilities. Experiments to date have primarily focused on detection and analysis of multiple gas species under semi-static conditions, with applications ranging from environmental monitoring of greenhouse gases to high resolution molecular spectroscopy. Here, we utilize dual-comb spectroscopy to demonstrate broadband, high-resolution, and time-resolved measurements in a laser induced plasma for the first time. As a first demonstration, we simultaneously detect trace amounts of Rb and K in solid samples with a single laser ablation shot, with transitions separated by over 6 THz (13 nm) and spectral resolution sufficient to resolve isotopic and ground state hyperfine splittings of the Rb D 2 line. This new spectroscopic approach offers the broad spectral coverage found in the powerful techniques of laser-induced breakdown spectroscopy (LIBS) while providing the high-resolution and accuracy of cw laser-based spectroscopies.

Frequency comb↗

4D Density Determination of NH Radicals in an MSE Microplasma Combining Planar Laser Induced Fluorescence and Cavity Ring-Down Spectroscopy

An application of microplasmas is surface modification under mild conditions and of small, well defined areas. For this, an understanding of the plasma composition is of importance. First results of our work on the production and detection of NH radicals in a capacitively coupled radio frequency (RF) microplasma are presented. A microstructured comb electrode was used to generate a glow discharge in a hydrogen/nitrogen gas mixture by applying 13.56 MHz RF voltage. The techniques of planar laser induced fluorescence (PLIF) and cavity ring-down spectroscopy (CRDS) are used for space and time resolved, quantitative detection of the NH radical in the plasma. The rotational temperature was determined to be 820 K and, the density 5.1x10{sup 12} cm{sup 3}. Also, time dependent behaviour of the NH production was observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MODELING TECHNIQUES FOR LIQUID PROPELLANT ROCKET COMBUSTION PROCESSES

A qualitative physical processes description of stable and unstable combustion in rockets is presented to establish the basis for choosing model hardware design criteria. It is concluded that it is not possible to scale rocket combustion processes in the usual sense of the term. The studies conducted at Rocketdyne have shown that model chambers which satisfactorily model the steady state behavior of large engines must be designed to maintain (1) the propellant injection density, and (2) the chamber to throat Contraction ratio (hence chamber pressure). For studies of destructive acoustic modes of combustion instability a third parameter, the frequency, must also be maintained.

COMBUSTION↗

Generation of Optical Combs in a WGM Resonator from a Bichromatic Pump

Optical combs generated by a monolithic resonator with Kerrmedium can be used in a number of applications, including orbital clocks and frequency standards of extremely high accuracy, such as astronomy, molecular spectroscopy, and the like. The main difficulty of this approach is the relatively high pump power that has to be used in such devices, causing undesired thermorefractive effects, as well as stimulated Raman scattering, and limiting the optical comb quality and utility. In order to overcome this problem, this innovation uses a different approach to excitation of the nonlinear oscillations in a Kerr-nonlinear whispering gallery mode (WGM) resonator and generation of the optical comb. By coupling to the resonator two optical pump frequencies instead of just one, the efficiency of the comb source can be increased considerably. It therefore can operate in a lowerpower regime where the undesirable effects are not present. This process does not have a power threshold; therefore, the new optical component can easily be made strong enough to generate further components, making the optical comb spread in a cascade fashion. Additionally, the comb spacing can be made in an arbitrary number of the resonator free spectral ranges (FSR). The experimental setup for this innovation used a fluorite resonator with OMEGA= 13.56 GHz. This material has very low dispersion at the wavelength of 1.5 microns, so the resonator spectrum around this wavelength is highly equidistant. Light was coupled in and out of the resonator using two optical fibers polished at the optimal coupling angle. The gap between the resonator and the fibers, affecting the light coupling and the resonator loading, was controlled by piezo positioners. The light from the input fiber that did not go into the resonator reflected off of its rim, and was collected by a photodetector. This enabled observation and measurement of the (absorption) spectrum of the resonator. The input fiber combined light from two lasers centered at around 1,560 nanometers. Both laser frequencies were simultaneously scanned around the selected WGMs of the same family. However, they were separated by one, two, three, or ten FSRs. This was achieved by fine-tuning each laser frequency offset until the selected resonances overlap on the oscilloscope screen. The resonator quality factor Q = 7 x 10(exp 7) was relatively low to increase the linewidth and, therefore, the duty cycle of both lasers simultaneously coupled into their WGMs. The optical spectrum analyzer (OSA) connected to the output fiber was continuously acquiring data, asynchronously with the laser scan. The instrument was set to retain the peak power values; therefore, a trace recorded for a sufficiently long period of time reflected the situation with both lasers maximally coupled to the WGMs.

Strekalov, Dmitry V.↗

Improved masers for X-band and Ku band

Slow-wave structure of traveling-wave maser utilizes comb system which is comprised of ruby on one side and alumina on other; alumina also supports isolator material. Radiation at pump frequency is coupled to ruby through shaped alumina strips. Contact between ruby bars and comb completes conductance path for heat transfer.

Clauss, R. C.↗

Laser-assisted molecular alignment in a strongly dissipative environment

This paper shows that transient alignment of linear molecules in a dense collisional environment can result from the formation of trapped aligned ''dark'' states in a laser field constituting either a comb of resonant short pulses or a sinusoidally frequency-modulated wave with a continuous flux. Simulation of the laser-induced dynamics of CO molecules reveals that the latter approach is effective at room temperature and requires three orders of magnitude less laser intensity compared to known alignment techniques.

74 ATOMIC AND MOLECULAR PHYSICS↗

Tunable terahertz multichannel filter based on one-dimensional superconductor-dielectric photonic crystals

By means of the transfer matrix method, the transmission properties of one-dimensional photonic crystals (PCs) consisting of superconductor and dielectric have been systematically investigated within the terahertz frequency range (0.1–10 THz). It is shown that comb-like resonant peaks in transmission band can be formed without adding any defect layer in superconductor-dielectric PCs, which means that such a one-dimensional periodic structure can serve as a tunable terahertz multichannel filter by using the PCs passband. Furthermore, the influences coming from the period of the structure, the thickness of the components, the permittivity of the dielectric layers, temperature, and the normal conducting electrons on the filtering properties are also numerically investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Instrumentation for vector electric field measurements from DE-B

Instrumentation has been developed, using the symmetric double-floating probe technique, to make vector electric field measurements from the low-altitude Dynamics Explorer (DE-B) spacecraft. Six 11-m cylindrical antennas are deployed along three orthogonal axes to form the sensor array. The outer two meters of each element are used as sensors, which results in a baseline of 21.4 m for the dc measurement for each axis. Efforts have been made to provide straight antennas and antennas that will not bend from thermal stresses as sun angles are changed. Measurements of the dc electric field will be made 16 times/sec or every half-kilometer along the orbit. Sensitivity will be 0.1 mV/m with a range of + or - 1 V/m. A 20-channel comb filter spectrometer will monitor ac electric fields, concentrating on frequencies below 1 kHz. Electric fields from any single axis or two axes may be sampled by the spectrometer within the range of 1 microvolt/m to 10 mV/m

Maynard, N. C.↗

Ion beams extraction and measurements of plasma parameters on a multi-frequencies microwaves large bore ECRIS with permanent magnets

We have developed an all-permanent magnet large bore electron cyclotron resonance ion source (ECRIS) for broad ion beam processing. The cylindrically comb-shaped magnetic field configuration is adopted for efficient plasma production and good magnetic confinement. To compensate for disadvantages of fixed magnetic configuration, a traveling wave tube amplifier (TWTA) is used. In the comb-shaped ECRIS, it is difficult to achieve controlling ion beam profiles in the whole inside the chamber by using even single frequency-controllable TWTA (11-13GHz), because of large bore size with all-magnets. We have tried controlling profiles of plasma parameters and then those of extracted ion beams by launching two largely different frequencies simultaneously, i.e., multi-frequencies microwaves. Here we report ion beam profiles and corresponding plasma parameters under various experimental conditions, dependence of ion beams against extraction voltages, and influence of different electrode positions on the electron density profile.

43 PARTICLE ACCELERATORS↗

Theory and applications of sampled analog recursive CTD comb filters

Sampled analog comb filter using a recursive filter implementation was studied. Charge transfer device delay lines were used as the delay elements. The similarities and differences between sampled analog recursive filter and digital recursive filter were pointed out. Both canceller type and integrator type comb filter using the first order or the second order canonical circuits were studied. Experimental results of frequency response are presented to show their difference from that of digital filters. A theoretical analysis was presented based essentially on the digital filter theory but modified to take into account the differences described above. The usefulness of this theory in analyzing the comb filter characteristics was discussed. Several applications of both the canceller type comb filter and the integrator type comb filter were demonstrated.

Tao, T. F.↗