Mach 1 oxidation of thoriated nickel chromium at 1204 C /2200 F/.

Electropolished and ground samples of TD-NiCr were exposed to a 1-atm, Mach 1 gas stream at 1204 C for times up to 50 hr. The samples were subjected to both cyclic and isothermal exposure. Weight change, metal loss, X-ray diffraction, metallographic, and electron microprobe analyses were performed. Neither surface preparation nor cyclic-against-isothermal-exposure conditions had a strong effect on the oxidation behavior of the alloy. Initially, a Cr2O3 layer was formed whose volatilization resulted in a very rapid loss of metal - more than 40 microns in the first hour. At about 1 hr, the Cr2O3 layer broke down and NiO began to cover the surface. By 5 hr, the NiO had covered the surface and the rate of loss slowed. The rate-controlling step was diffusion of Cr through NiO.

Lowell, C. E.↗

Brayton heat exchanger unit development program (alternate design)

A Brayton Heat Exchanger Unit Alternate Design (BHXU-Alternate) consisting of a recuperator, a heat sink heat exchanger, and a gas ducting system, was designed and fabricated. The design was formulated to provide a high performance unit suitable for use in a long-life Brayton-cycle powerplant. Emphasis was on double containment against external leakage and leakage of the organic coolant into the gas stream. A parametric analysis and design study was performed to establish the optimum component configurations to achieve low weight and size and high reliability, while meeting the requirements of high effectiveness and low pressure drop. Layout studies and detailed mechanical and structural design were performed to obtain a flight-type packaging arrangement, including the close-coupled integration of the BHXU-Alternate with the Brayton Rotating Unit (BRU).

Duncan, J. D.↗

Dynamic oxidation behavior at 1000 and 1100 C of four nickel-base cast alloys, NASA-TRW VIA, B-1900, 713C, and 738X

The superalloys NASA-TRW VIA, B-1900, 713C, and 738X were tested cyclically and isothermally for resistance to oxidation in high velocity gas streams for 100 hours at specimen temperatures of 1000 C and 1100 C. Alloys VIA and B-1900, which were the most oxidation resistant, displayed slight and very similar weight changes and metal losses. Alloy 713C also sustained only slight metal losses, but it exhibited some tendency to spall. Alloy 738X was found to be the most susceptible to cyclic oxidation; this resulted in heavy spalling, which in turn caused high weight losses and high metal losses. Oxidation test results are related to the amounts of chromium aluminum, and the refractory metals in the alloys investigated.

Sanders, W. A.↗

Particle flow within a transonic compressor rotor passage with application to laser-Doppler velocimetry

A theoretical analysis was conducted of the dynamic behavior of micron size particles moving in the three-dimensional flow field of a rotating transonic axial-flow air compressor rotor. The particle velocity lag and angular deviation relative to the gas were determined as functions of particle diameter, mass density and radial position. Particle size and density were varied over ranges selected to correspond to typical laser-Doppler velocimeter (LDV) flow field mapping applications. It was found that the particles move essentially on gas stream surfaces and that particle tracking is relatively insensitive to the rotor radial coordinate. Velocity lag and angular deviation increased whenever particle size or mass density increased, and particle tracking was more sensitive to a change in particle diameter than to a corresponding change in mass density. Results indicated that velocity and angular deviations generally less than 1 percent and 1 degree could be achieved with 1 gm/cc tracer particles with diameters of 1 micron or less.

Maxwell, B. R.↗

Mass transfer in binary X-ray systems

The influence of X-ray heating on gas flows in binary X-ray systems is examined. A simple estimate is obtained for the evaporative wind flux from a stellar atmosphere due to X-ray heating which agrees with numerical calculations by Alme and Wilson (1974) but disagrees with calculations by Arons (1973) and by Basko and Sunyaev (1974) for the Her X-1/HZ Her system. The wind flux is sensitive to the soft X-ray spectrum. The self-excited wind mechanism does not work. Mass transfer in the Hercules system probably occurs by flow of the atmosphere of HZ Her through the gravitational saddle point of the system. The accretion gas stream is probably opaque with atomic density of not less than 10 to the 15th power per cu cm and is confined to a small fraction of 4(pi) steradians. Other binary X-ray systems are briefly discussed.

Mccray, R.↗

Melting behavior and phase relations of lunar samples

An attempt was made to show that feldspar would float during melting. Large anorthite crystals were placed beneath a silicate glass representative of liquid in which plagioclase accumulation is thought to have occurred. In less than 3 hours at 1,300 C, the crystals rose to the top in a Pt crucible 3 cm deep equilibrated in air and in a Mo crucible 1.5 cm deep equilibrated in an H2/CO2 gas stream of log PO2 = -10.9 (below Fe/FeO). These results suggest that lunar crustal formation by feldspar flotation is possible without special recourse to differential sinking of plagioclase versus mafic minerals or selective elutriation of plagioclase.

Hays, J. F.↗

Oxidation of contaminative methane traces with radio-frequency discharge

An 11.8 MHz glow discharge was used to oxidize trace levels of methane in oxygen. The concentration of methane can be reduced by three orders of magnitude. The effects of power (0-400 W), flow rate (10-1000 cc-STP/min) and concentration (70-8000 ppm) were investigated at pressures ranging from 50 torr to almost 1 atm. No organic reaction products were detected in the treated gas stream. The process may prove useful for the removal of atmospheric trace contaminants at ambient pressure.

Flamm, D. L.↗

Comments on unmixedness

Unmixedness in flames refers to the condition in which eddies of fuel and oxidant have engulfed each other but where the molecular mixing necessary for complete reaction has not taken place. This phenomenon is studied experimentally using a flow geometry consisting of a coaxial Mach 2 hydrogen jet surrounded by a parallel cold Mach 2 air stream. Gas sample measurements taken downstream in the region near the flame revealed the presence of unreacted hydrogen and oxygen in the same sample. The data were analyzed by means of the CHARNAL program which uses a step function variation with time for instantaneous concentration.

Eggers, J. M.↗

A high pressure, high temperature combustor and turbine-cooling test facility

A new test facility is being constructed for developing turbine-cooling and combustor technology for future generation aircraft gas turbine engines. Prototype engine hardware will be investigated in this new facility at gas stream conditions up to 2480 K average turbine inlet temperature and 4.14 x 10 to the 6th power n sq m turbine inlet pressure. The facility will have the unique feature of fully automated control and data acquisition through the use of an integrated system of mini-computers and programmable controllers which will result in more effective use of operating time, will limit the number of operators required, and will provide built in self protection safety systems. The facility and the planning and design considerations are described.

Cochran, R. P.↗

Technology advancement of the static feed water electrolysis process

Some results are presented of a research and development program to continue the development of a method to generate oxygen for crew metabolic consumption during extended manned space flights. The concept being pursued is that of static feed water electrolysis. Specific major results of the work included: (1) completion of a 30-day electrode test using a Life Systems, Inc.-developed high performance catalyst. During startup the cell voltages were as low as 1.38 V at current densities of 108 mA/sq cm (100 ASF) and temperatures of 355 K (180 F). At the end of 30 days of testing the cell voltages were still only 1.42 V at 108 mA/sq cm, (2) determination that the Static Feed Water Electrolysis Module does not release an aerosol of the cell electrolyte into the product gas streams after a break-in period of 24 hours following a new electrolyte charge, and (3) completion of a detailed design analysis of an electrochemical Oxygen Generation Subsystem at a three-man level (4.19 kg/day (9.24 lb/day) of oxygen).

Jensen, F. C.↗

Effect of heating method on stress-rupture life

The effect of radiant(furnace), resistance(electric current), burner(hot gas stream), and a combination of resistance and burner heating on intermediate time (100 to 300 hr) stress-rupture life and reduction of area was evaluated. All heating methods were studied using the nickel-based alloy Udimet 700 while all but burner heating were evaluated with the cobalt-based alloy Mar-M 509. Limited test results of eight other superalloys were also included in this study. Resistance heated specimens had about 20 to 30 percent of the stress-rupture life of radiant heated specimens. The limited burner heating data showed about a 50 percent life reduction as compared to the radiant heated tests. A metallurgical examination gave no explanation for these reductions.

Bizon, P. T.↗

Spectrophotometry of the X-ray binary HZ Herculis

An extensive set of absolute spectrophotometric observations of HZ Her over the wavelength range from 3300 to 10,000 A is presented and analyzed to determine to what extent the observations can be interpreted in terms of a model for the system. The specific model to be tested consists of a large star (HZ Her) with a hot cap beneath the X-ray source, an accretion disk around the X-ray source, and a gas stream flowing between the primary star and the disk. It is found that the model is compatible to a large extent with the detailed observations and that the physical characteristics of the various components can be derived. The mass, luminosity, and radius of the primary star, the mass of the X-ray object, and the orbital dimensions are obtained by analyzing the energy distribution at minimum light and X-ray eclipse data. The angle and effective temperature of the hot cap on the primary are also determined along with the energy distribution, diameter, and thickness of the accretion disk. It is concluded that HZ Her fills its Roche lobe and is an A7 V star, that the logarithm of its surface gravity is about 3.6, and that the mass of the X-ray object is 1.95 solar masses.

Oke, J. B.↗

A high-pressure, high-temperature combustor and turbine-cooling test facility

NASA-Lewis Research Center is presently constructing a new test facility for developing turbine-cooling and combustor technology for future generation aircraft gas turbine engines. Prototype engine hardware will be investigated in this new facility at gas stream conditions up to 2480 K average turbine inlet temperature and 4,140,000 N per sq m turbine inlet pressure. The facility will have the unique feature of fully-automated control and data acquisition through the use of an integrated system of minicomputers and programmable controllers, which will result in more effective use of operating time, will limit the number of operators required, and will provide a built-in self-protection safety system. The paper describes the facility and the planning and design considerations involved.

Cochran, R. P.↗

X-rays from massive black holes

Tidal disruption of nondegenerate stars is shown to provide an important heat source for gas accreting onto massive black holes (about 10 to 100 million solar masses) in galactic nuclei. Turbulent dissipation by accreting gas streams can also be significant, and the heat input suffices to give rise to temperatures above about 1 billion K, resulting in an appreciable hard X-ray luminosity.

Meszaros, P.↗

Hydrogen production by water decomposition using a combined electrolytic-thermochemical cycle

A proposed dual-purpose power plant generating nuclear power to provide energy for driving a water decomposition system is described. The entire system, dubbed Sulfur Cycle Water Decomposition System, works on sulfur compounds (sulfuric acid feedstock, sulfur oxides) in a hybrid electrolytic-thermochemical cycle; performance superior to either all-electrolysis systems or presently known all-thermochemical systems is claimed. The 3345 MW(th) graphite-moderated helium-cooled reactor (VHTR - Very High Temperature Reactor) generates both high-temperature heat and electric power for the process; the gas stream at core exit is heated to 1850 F. Reactor operation is described and reactor innards are illustrated. A cost assessment for on-stream performance in the 1990's is optimistic.

Farbman, G. H.↗

Experimental determination of transient strain in a thermally-cycled simulated turbine blade utilizing a non-contact technique

A type of noncontacting electro-optical extensometer was used to measure the displacement between parallel targets mounted on the leading edge of a simulated turbine blade throughout a complete heating and cooling cycle. The blade was cyclically heated and cooled by moving it into and out of a Mach 1 hot gas stream. The principle of operation and measurement procedure of the electro-optics extensometer are described.

Calfo, F. D.↗