Search NASA⌕ Search

SEARCH · Search NASA

Results for “GETTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Commissioning of Extended Electron Beam Ion Source at Brookhaven National Laboratory

Here, the Extended Electron Beam Ion Source (EEBIS) has been installed and commissioned at Brookhaven National Laboratory (BNL) hadron accelerator complex in the spring of 2023. EEBIS has replaced its predecessor, RhicEBIS, which provided ions for BNL hadron facilities for over a decade since 2009. The motivations for the source upgrade are to provide higher intensities of the Au 32+ ion beam for the Relativistic Heavy Ion Collider (RHIC) and to provide of an intense source of polarized 3 He 2+ ions for the future Electron Ion Collider (EIC) at BNL. EEBIS is and will continue to be the primary source for a variety of different ion species for the NASA Space Radiation Laboratory (NSRL) at BNL. EEBIS utilizes two identical, two-meter-long unshielded 5T warm bore superconducting solenoids, and it is operated with electron beam current up to 10 A, providing a high-capacity ion traps to fulfill the requirement for high intensity ion beams. The upstream solenoid contains a “short ion trap” with a length of 95 cm, while the “long ion trap” with a length of 178 cm is located inside the downstream solenoid bore. The main features of EEBIS are: * A Gas injection and ionization cell equipped with a Lorenz pulse valve * High-capacity ZAO non-evaporable getter (NEG) custom linear pumping units * In situ apparatus for pumping speed measurements to monitor NEG activation and saturation * “External drift tube” construction with differential pumping stages to provide space for Lorentz pulse valve and 3 He high-field polarization cell * A Ba oxide electron gun cathode. The design of EEBIS as well as the results of its commissioning and first-year operation are presented and discussed.

43 PARTICLE ACCELERATORS↗

Detection of hot electrons originating from an upper valley at ∼1.7eV above the Γ valley in wurtzite GaN using electron emission spectroscopy

Using electron emission spectroscopy, measurement and analysis were conducted on the energy distribution of vacuum emitted electrons from electrically driven InGaN/GaN green (peak wavelengths 𝜆 ≈ 515nm) light-emitting diodes (LEDs) with and without a prewell superlattice (SL). Here, we report on the detection of a high-energy upper valley at ∼ 1.7eV above the Γ valley from samples with no prewell SL. We propose that these upper valley electrons originate predominantly from trap-assisted Auger recombination (TAAR) in green LEDs, as the intensity of these peaks is found to have quadratic dependence on the carrier density 𝑛 [see Espenlaub et al., J. Appl. Phys. 126, 184502 (2019)]. The high-energy upper valley peak was not observed in the sample with a prewell SL which is attributed to gettering by the prewell SL of still unidentified impurities that act as TAAR centers.

carrier generation & recombination↗

X-ray nanodiffraction studies of ionically controlled nanoscale phase separation in cobaltites

Complex oxide heterostructures provide access to emergent functional and structural phases that are not present in the bulk constituent materials. In this Rapid Communication, we focus on $La_{0.67}Sr_{0.33}CoO_3$ (LSCO)/Gd heterostructures due to the high oxygen ion conductivity, as well as the coupled magnetic and electronic properties of LSCO, which are strongly dependent on the oxygen stoichiometry. This combination of properties enables the ionic control of the functional properties of LSCO thin films through the presence of oxygen getter layers such as Gd.We utilize x-ray nanodiffraction to directly image the nanoscale morphology of LSCO thin films as they are progressively transformed from the equilibrium perovskite phase to the metastable brownmillerite (BM) phase with increasing Gd thickness. Our studies show the coexistence of perovskite and BM phases with a critical oxygen vacancy concentration threshold which leads to the formation of extended BM filaments. In addition to lateral phase separation, we observed phase separation within the film thickness possibly due to pinning of the perovskite and BM phases by the substrate/LSCO and LSCO/Gd interface, respectively. Our studies provide a nanoscale survey of the phase separation in the cobaltites and shed light on the formation of the metastable BM phase.

36 MATERIALS SCIENCE↗

Mitigating Process Induced Degradation in p- and n-Czochralski Silicon Wafers with Tabula Rasa

We report on the bulk properties of of n- and p- type Czochralski silicon (Cz-Si) after a high-temperature annealing process known as Tabula Rasa (TR), which is primarily used to annihilate oxygen precipitates. We find significant differences in n- and p-type substrates as well as a strong dependence on the ambient in the resulting process induced degradation. We attribute this ambient dependence to either injection of interstitials or vacancies into the bulk during TR. Finally, we show that subsequent gettering is enhanced due to the annihilation of oxygen precipitates.

14 SOLAR ENERGY↗

Development and Durability Testing of a Low‐Temperature Sintering Bi–Si–Zn Oxide Glass Composite Material (GCM) 129 I Waste Form

The capture and safe storage of radiological iodine ( 129 I) from nuclear fuel reprocessing is of concern due to its long half‐life and potential mobility in the environment. The development of durable waste forms in which to store captured iodine requires materials that are both compatible with the iodine capture phases and durable to repository environments. To that end, Sandia is developing a low‐temperature sintering Bi–Si–Zn oxide glass composite material (GCM) waste form and herein presents results of durability testing. Furthermore, durability studies were extended to both the occluded iodine capture material Ag‐Zeolite (Mordenite, MOR) as well as the GCM, synthesized with compositional variations including: amount of Ag flake added, AgI‐MOR particle size in the GCM, and mass loading of I within the AgI‐MOR. Product consistency test (PCT‐B), chemical durability (MCC‐1) tests, and single‐pass flow‐through (SPFT) tests, were performed on both the individual components of the GCM and the completed GCMs. Durability tests indicate low GCM dissolution rates (<10 −3 g/m 2 ·d) across wide variable ranges including: pH, AgI‐MOR loading, I loading, and AgI‐MOR particle size. Results indicate that the Bi–Si–Zn oxide glass matrix sharply limits the release of iodine from the otherwise relatively fast degrading AgI‐MOR getter material. Furthermore, the formation of an amorphous AgI phase during sintering of the GCM results in the limitation of iodine release during waste form degradation. Durability of GCM and release rates approximate those of established nuclear waste glasses, or analogues such as basaltic glass. This suggests that the Bi–Si–Zn GCM is a viable candidate as a repository iodine waste form.

Mowry, Curtis D.↗

Heavy-ion induced desorption of a TiZrV coated vacuum chamber bombarded with 5 MeV/u Ar{sup 8+} beam at grazing incidence

TiZrV nonevaporable getter (NEG) coated vacuum chambers is a new vacuum technology which is already used in many particle accelerators worldwide. This coating is also of interest for heavy-ion accelerator vacuum chambers. Heavy-ion desorption yields from an activated as well as a CO saturated NEG coated tube have been measured with 5 MeV/u Ar{sup 8+} beam. The sticking probability of the NEG film was obtained by using the partial pressure ratios on two sides of the NEG coated tube. These ratios were compared to results of modeling of the experimental setup with test particle Monte Carlo and angular coefficient methods. The partial pressures inside the saturated NEG coated tube bombarded with heavy ions were up to 20 times larger than those inside the activated one. However, the partial pressure of methane remained the same. The value of the total desorption yield from the activated NEG coated tube is 2600 molecules/ion. The desorption yields after saturation for CH{sub 4}, H{sub 2}, and CO{sub 2} were found to be very close to the yields measured after the activation, while CO increased by up to a factor of 5. The total desorption yield for the saturated tube is up to 7000 molecules/ion. The large value of the desorption yield of the activated NEG coated tube, an order of magnitude higher than the desorption yield from a stainless steel tube at normal incident angle, could be explained by the grazing incident angle.

36 MATERIALS SCIENCE↗

Electron-stimulated desorption from polished and vacuum fired 316LN stainless steel coated with Ti-Zr-Hf-V

In this study, two identical 316LN stainless steel tubular samples, which had previously been polished and vacuum-fired and then used for the electron-stimulated desorption (ESD) experiments, were coated with Ti-Zr-Hf-V with different morphologies: columnar and dense. ESD measurement results after nonevaporable getter (NEG) activation to 150, 180, 250, and 350 °C indicated that the values for the ESD yields are significantly (2–20 times) lower than the data from our previous study with similar coatings on nonvacuum-fired samples. Based on these results, the lowest pressure and best long-term performance in particle accelerators will be achieved with a vacuum-fired vacuum chamber coated with dense Ti-Zr-Hf-V coating activated at 180 °C. This is likely due to the following facts: after NEG activation, the hydrogen concentration inside the NEG was lower than in the bulk stainless steel substrate; the NEG coating created a barrier for gas diffusion from the sample bulk to vacuum; the dense NEG coating performed better as a barrier than the columnar NEG coating.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long-life micro vacuum chamber for a micromachined cryogenic cooler

Micromachined cryogenic coolers can be used for cooling small electronic devices to improve their performance. However, for reaching cryogenic temperatures, they require a very good thermal insulation from the warm environment. This is established by a vacuum space that for adequate insulation has to be maintained at a pressure of 0.01 Pa or lower. In this paper, the challenge of maintaining a vacuum chamber with a volume of 3.6 × 10{sup −5} m{sup 3} and an inner wall area of 8.1 × 10{sup −3} m{sup 2} at a pressure no higher than 0.01 Pa for five years is theoretically analyzed. The possible sources of gas, the mechanisms by which these gases enter the vacuum space and their effects on the pressure in the vacuum chamber are discussed. In a long-duration experiment with four stainless steel chambers of the above dimensions and equipped with a chemical getter, the vacuum pressures were monitored for a period of two years. In that period, the measured pressure increase stayed within 0.01 Pa. This study can be used to guide the design of long-lifetime micro vacuum chambers that operate without continuous mechanical pumping.

42 ENGINEERING↗

A passively pumped vacuum package sustaining cold atoms for more than 200 days

Compact cold-atom sensors depend on vacuum technology. One of the major limitations to miniaturizing these sensors is the active pumps—typically ion pumps—that are required to sustain the low pressure needed for laser cooling. Although passively pumped chambers have been proposed as a solution to this problem, technical challenges have prevented successful operation at the levels needed for cold-atom experiments. The authors present the first demonstration of a vacuum package successfully independent of ion pumps for more than a week; their vacuum package is capable of sustaining a cloud of cold atoms in a magneto-optical trap (MOT) for greater than 200 days using only non-evaporable getters and a rubidium dispenser. Measurements of the MOT lifetime indicate that the package maintains a pressure of better than 2×10−7 Torr. This result will significantly enable the development of compact atomic sensors, including those sensitive to magnetic fields, where the absence of an ion pump will be advantageous.

Little, Bethany J. (ORCID:0000000332892798)↗

Side-by-side evaluation of the outgassing rate and ultimate pressure achieved inside tubes made of low-carbon and stainless steel

The hydrogen outgassing rate of a vacuum chamber made of AISI 1020 low-carbon steel was found to be notably smaller than a similar chamber made of AISI 316L stainless steel following heat treatment at 150 °C. When the chambers were baked at 400 °C, the outgassing rate of the 1020 low-carbon steel chamber was approximately 2000 times smaller than that of the 316L stainless-steel chamber. After quantifying hydrogen outgassing rates, vacuum chambers made of 1020 low-carbon steel and 316L stainless steel were heated for a prescribed duration and then pumped with an ion pump and nonevaporable getter pump to reach “ultimate pressure.” The 1020 low-carbon steel chamber reached lower pressures than the 316L stainless-steel chamber. Monte Carlo simulation predictions using the measured hydrogen outgassing rates are in good agreement with the ultimate pressure measurements. Finally, our measurements indicate that low-carbon steel can provide pressures within the extreme high vacuum range (<7.5 × 10 -13 Torr) if care is taken to minimize the surface area contribution from stainless steel.

36 MATERIALS SCIENCE↗

A high-temperature radiation-resistant rectifier based on p{sup +}-n junctions in 4H-SiC ion-implanted with aluminum

A combination of a high-dose (5 s- 10{sup 16} cm{sup -2}) implantation of Al ions into epitaxial n-type 4H SiC layers grown by chemical deposition from th e vapor phase and rapid (15 s) thermal annealing at 1700-1750 deg. C has been used to form layers with a rectangular impurity profile according to the mechanism of solid-phase epitaxial crystallization. The combined effects of enhanced diffusion of radiation defects after implantation and gettering of defects during annealing bring about an improvement in the quality of the initial material, which ensures an increase in the diffusion length of the minority charge carriers by several times. Metastable states annealed within different temperature ranges are formed in SiC under the effect of irradiation with various particles. Low-temperature annealing of radiation defects increases the radiation and temporal lifetime of devices under irradiation. High-temperature annealing of radiation defects makes it possible to vary the lifetime of nonequilibrium charge carriers, i.e, vary the frequency range of devices. The radiation resistance of SiC-based devices increases as the operation temperature is increased to 500 deg. C.

36 MATERIALS SCIENCE↗

The effect of morphology and surface composition on radiation resistance of heterogeneous material CdS-PbS

As a result of a complex study of the heterophase photosensitive material CdS-PbS by the methods of scanning electron microscopy and Auger spectrometry, it has been found that the radiation resistance of this material depends on the morphology and phase composition at its surface. It is shown that, as the temperature of annealing is increased, aggregations with predominant content of PbS grow; simultaneously, the composition of these aggregations varies as a consequence of the reaction of substitution of sulfur atoms with oxygen atoms. The latter of the aforementioned processes brings about a decrease in the radiation resistance of the heterophase photosensitive material CdS-PbS, which is accounted for by a decrease in the gettering due to appearance of an intermediate oxidized layer between PbS and CdS. An increase in the sizes and number of spherical aggregations at the surface, which consist of crystallites with predominant content of PbS, brings about an increase in the radiation resistance.

36 MATERIALS SCIENCE↗

LSM/YSZ Button Cell Tests in Cathode Air with Measured Cr Concentrations

A test fixture and methodology was developed for testing anode-supported SOFC button cells downstream from a chromia pellet at a prescribed temperature for qualitative control of Cr volatility. An alumina foam coated with Cr-gettering Na2CO3 was placed downstream from the cell to capture Cr species from the cathode air by reacting to form Na2CrO4. The coating and reaction product are both water soluble, facilitating dissolution from the porous substrate for subsequent ICP analysis to determine the Cr concentration in the resulting solution. The mass of collected Cr is used to calculate the average Cr concentration in the known volume of air used during the test. Cells with LSM/YSZ cathodes were electrochemically tested for 600 to 1000 hours with chromia pellets at varying conditions of temperature and humidity to elicit varying levels of Cr volatility. Molar Cr concentrations of only 40 to 170 ppt caused ~4%/kh degradation.

Hardy, John S.↗

Temperature-Dependent Sheet and Contact Resistivity Measurements on Ag and Ag-Ni Circuit Pastes

The metal circuits and brazes used in electronic, energy conversion, and/or energy storage devices often have difficulty wetting and adhering to ceramic and/or ceramic-passivated metal substrates. Here, a novel Particle Interlayer Directed Wetting and Spreading (PIDWAS) technique is demonstrated that utilizes screen printing, the low wetting angle of silver on nickel, and the high work of adhesion between nickel and various ceramics to produce well-adhered, self-assembled silver patterns on ceramic and/or stainless-steel substrates not normally wet by silver. The resulting Ag-Ni circuits have higher sapphire adhesion strengths (up to 30 MPa on sapphire), higher densities (>97% on sapphire), and similar high-temperature electronic resistivities to those made using commercially-available Heraeus C8710 or DAD-87 silver circuit pastes. Similarly, Ag-Ni brazes between a variety of ceramic and/or stainless-steel substrates have better microstructural stability with rapid thermal cycling, reduction-oxidation cycling, and dual atmosphere isothermal aging than conventional Ag-CuO brazes. In addition, the residual Ni in these Ag-Ni circuits and brazes can be used to chemically getter surface segregated Al, ensuring low contact resistances on a variety of chromia- and/or alumina-passivated stainless steels. Reference: [1] Hu G, Zhou Q, Bhatlawande A, Park J, Termuhlen R, Ma Y, Bieler TR, Yu HC, Qi Y, Hogan T & Nicholas JD. Patterned Nickel Interlayers for Enhanced Silver Wetting, Spreading and Adhesion on Ceramic Substrates. Scripta Materialia, 2021; 196, 113767. 10.1016/j.scriptamat.2021.113767 [2] Park J, Phongpreecha T, Nicholas JD & Qi Y. Enhanced Liquid Metal Wetting on Oxide Surfaces via Patterned Particles. Acta Materialia, 2020; 199, 551-560. 10.1016/j.actamat.2020.08.037

Bhatlawande, Aishwarya↗

Numerical comparison of hydrogen desorption behaviors of metal hydride beds based on uranium and on zirconium-cobalt

In this paper, the hydrogen delivery capabilities of uranium (U) and zirconium-cobalt (ZrCo) are compared quantitatively in order to find the optimum getter materials for tritium storage. A three-dimensional hydrogen desorption model is applied to two identically designed cylindrical beds with the different materials, and hydrogen desorption simulations are then conducted. The simulation results show superior hydrogen delivery performance and easier thermal management capability for the U bed. This detailed analysis of the hydrogen desorption behaviors of beds with U and ZrCo will help to identify the optimal bed material, bed design, and operating conditions for the storage and delivery system in ITER. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydriding performances and modeling of a small-scale ZrCo bed

In order to evaluate the performance of the hydriding of a ZrCo bed, a small-scale getter bed of ZrCo was designed and fabricated. The results show that the hydriding time at room temperature was somewhat shorter than that at higher temperatures of ZrCo and that the performance of hydriding at low temperatures of ZrCo was better than that at high temperatures of ZrCo. The experimental results of the hydrogen pressure of hydriding (ZrCoH{sub 2.8}) at different temperatures were in agreement with the computed values using a numerical modeling equation but with a small difference during the first 10 minutes of the hydriding of ZrCo. The model is based on the Kozeny-Carman equation. The effect of a helium blanket on hydriding was measured and analyzed. The hydriding with no helium blanket in the primary vessel of ZrCo is much faster than that with a helium blanket. The hydriding at a helium concentration of 8% is slower than that at 0%. As the helium concentration increases, the hydriding of ZrCo decreases. The experimental results of the hydriding with 0 %, 4%, and 8% of helium concentration are in agreement with the calculated values but with minimal differences during the first 10 minutes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

IMPEDANCE MEASUREMENT OF VACUUM CHAMBER COMPONENTS FOR THE ADVANCE PHOTON SOURCE (APS) UPGRADE

The proposed Advance Photon Source Upgrade (APS-U) employs a multi-bend achromat (MBA) lattice to increase the photon brightness by two to three orders of magnitude. One of the main design challenges of the upgrade is to minimize rf heating and collective instabilities associated with the impedance of small-aperture vacuum components. As part of this effort, my research focuses on impedance measurement and simulation of various MBA vacuum components. Here, we present the summary of the impedance contributions for the APS-U and describe our planned impedance measurement technique, including some measurement results for the non-evaporative getter (NEG)-coated copper chamber and simulation results for other critical components using a novel Goubau line (G-line) set up.

APS↗

Vertical Septum Magnet Design for the APS Upgrade

The vertical injection scheme proposed for the APS Upgrade (APS-U) Project requires a challenging septum magnet that must meet stringent beam physics, magnetic field leakage, and vacuum requirements. The current iteration of this magnet design includes an enlarged stored-beam chamber aperture of 9 mm x 12 mm and a reduction of the septum thickness to 1.5 mm. The enlarged aperture accommodates a non-evaporable getter (NEG)-coated stored beam chamber to better achieve the required vacuum. A prototype septum magnet has been built and measurements confirm the cancellation of a peak leakage field even though the value is six times larger than the design. The leakage field measured at the upstream (US) end cancels the downstream (DS) end as was expected by design. The measured and simulated leakage field and the stored beam trajectories are reported.

43 PARTICLE ACCELERATORS↗