Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Satellite ultraviolet measurements of nitric oxide fluorescence with a diffusive transport model.

Twilight measurements of fluorescence in the (1, 0) gamma band of nitric oxide were made from June 1967 to January 1969 by an ultraviolet scanning spectrometer on board the polar orbiting satellite Ogo 4. Nitric oxide vertical column emission rates were measured between solar zenith angles of 93 and 98 deg. Seasonal and latitudinal variations were found to be less than a factor of 1.3, the scatter and uncertainty in the data prohibiting more precise determinations from being made. Time independent chemical diffusion models for the vertical distribution of nitric oxide agree well with profiles measured from sounding rockets. The column emission rates calculated from the theoretical models are larger than the satellite measurements by a factor of 3.

Rusch, D. W.↗

Effects of cobalt on the microstructure of Udimet 700

Cobalt, a critical and "strategic" alloying element in many superalloys, was systematically substituted by nickel in experimental alloys Udimet 700 containing 0.1, 4.3, 8.6, 12.8 and the standard 17.0 wt.% cobalt. Electrolytic and chemical extraction techniques, X-ray diffraction, scanning electron and optical microscopy were used for the microstructural studies. The total weight fraction of gamma' was not significantly affected by the cobalt content, although a difference in the size and quantities of the primary and secondary gamma' phases was apparent. The lattice parameters of the gamma' were found to increase with increasing cobalt content while the lattice mismatch between the gamma matrix and gamma' phases decreased. Other significant effects of cobalt on the weight fraction, distribution and formation of the carbide and boride phases as well as the relative stability of the experimental alloys during long-time aging are also discussed.

Engel, M. A.↗

Signal and data processing of small targets 1989; Proceedings of the Meeting, Orlando, FL, Mar. 27-29, 1989

The present conference on digital signal processing, association and filtering techniques, and multiple-sensor/multiple-tracking techniques, discusses single-frame velocity estimation, efficient target extraction for laser radar imagery, precision target tracking for small extended objects, IR clutter partitioning for matched filter design, the maximum-likelihood approach to gamma circumvention, position estimation for optical point targets using staring detector arrays, and a multiple-scan signal processing technique for area-moving target indication. Also discussed are a proportional integral estimator, the prediction of track purity in tracking performance evaluations, synchronization and fault-tolerance in a distributed tracker, the benefits of soft sensors and probabilistic fusion, and testing track initiation algorithms fusing two-dimensional tracks.

Drummond, Oliver E.↗

Lunar and Planetary Science XXXV: Lunar Remote Sensing: Fire, Ice, and Regolith

The session "Lunar Remote Sensing: Fire, Ice, and Regolith" included the following:Compositional and Structural Study of the Aristarchus Plateau from Integrated UV-VIS-NIR Spectral Data; Clementine 2.7-?m Data: Mapping the Mare and Searching for Water; On the Search for Water at the Lunar Poles: Results of Forward Modeling of Permanently Shaded Areas and Lunar Prospector Measurements; Searching the Moon for Aluminous Mare Basalts Using Compositional Remote-Sensing Constraints I: Finding the Regions of Interest; Semi-automated Extraction of Contours from Lunar Topographic Maps; Basalts in Mare Humorum and S.E. Procellarum; The Hansteen and Helmet Volcanic Dome Regions on the Moon: Stratigraphy and Ages; Derivation of Elemental Abundance Maps at 15-km Spatial Resolution from the Merging of Clementine Optical and Lunar Prospector Geochemical Data; Remote Sensing and Geologic Studies of the Balmer Region of the Moon; Lava Flows in Mare Nubium and Mare Cognitum: A Geological History Based on Analysis of Multispectral Data; Development of Ground-based Lunar VIS/NEAR IR Spectral Imager; A BRDF Measurement Apparatus for Lab-based Samples; A New Source of High Resolution Lunar Images: Amateur Astronomers! ; Leakage of Gamma Rays and Neutrons from Thick Targets Bombarded by Energetic Protons; Progress on Reviving Lunar Orbiter: Scanning, Archiving, and Cartographic Processing at USGS; Modeling Lateral and Vertical Mixing by Impact Cratering with Applications for the Moon; Optical Maturity Study of Stuart#s Crater Candidate Impact; Evidence for Three Basins Beneath Oceanus Procellarum; and Ellipses of the South Pole-Aitken Basin: Implications for Basin Formation.

Source record↗

Dual Function of Cellulose Triacetate–Graft–Polymethacrylic Acid Films for Dyes Removal and for High-Dose Radiation Dosimetry

Graft copolymerization of methacrylic acid (MAc) onto cellulose triacetate (CTA) films was conducted by gamma rays. The grafting conditions were optimized. The structure of grafted CTA films was characterized by Fourier transform infra red–attenuated total reflection, scanning electron microscopy, thermal gravimetric analysis, CHNS/O microanalyzer and, surface area and porosity analyzer. The grafted CTA films were exploited in adsorption of ethyl violet (EV) and phenol red (PR) dyes. The adsorption capacity of the grafted CTA films was investigated at various variables. The adsorption isotherms and kinetic study were examined. Further, the dyed grafted CTA films were used in measurements of high dose radiation. The results indicate that the useful dose range extents up to 440 and 300 kGy for EV and PR, respectively. The effects of relative humidity during irradiation, shelf-life, pre- and post-irradiation storage in dark and indirect daylight conditions on dosimeters performance were investigated.

36 MATERIALS SCIENCE↗

Thermoluminescence (TL) properties and x-ray diffraction (XRD) analysis of high purity CaSO{sub 4}:Dy TL material

This paper presents the characterization and TL properties of dysprosium (Dy) doped calcium sulfate (CaSO{sub 4}) TL material produced by co-precipitation technique with 0.5mol% concentration of dopant. The morphology of the produced TL material was studied using scanning electron microscope (SEM) and the micrograph shows that rectangular parallelepiped shaped crystal with the average of 150 μm in length were produced. The crystallinity of the produced powder was studied using x-ray powder diffraction (XRD). The XRD spectra show that the TL material produced is high purity anhydrite CaSO{sub 4} with average crystallite size of 74 nm with orthorhombic crystal system. The TL behavior of produced CaSO{sub 4}:Dy was studied using a TLD reader after exposure to gamma ray by Co{sup 60} source with the doses of 1,5 and 10 Gy. The glow curve shows linear response with glow peak around 230°C which is desired development in the field of radiation dosimetry.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Frisker Response to Soil Concentrations (Bq/g) Compared to NaI(Tl) - 19338

The Chalk River Laboratories (CRL) began nuclear operations in 1947. Portions of the site land areas have become radiologically contaminated through the 1952 National Reactor Experimental (NRX) accident and/or waste management activities over the past 70 years of site operations. The Environmental Remediation Projects Group (ERP) characterizes, and performs risk assessment, and remedial actions, as required over these contaminated land areas. ERP work activities are subject to controls established by CRL's Radiation Protection (RP) Group such that RP establishes the radiological controls and monitoring requirements for ERP field work activities. The different methods of monitoring soil contamination between ERP and the RP program present some challenges in the interpretation and comparison of the two sets of results and the soil disposition. ERP utilizes NaI(Tl) scintillation detectors and MARSSIM land scanning techniques to measure soil concentrations between sample locations and in excavated materials. Whereas, RP utilizes surface contamination monitoring equipment in the form of a 15.5 cm{sup 2} open area pancake Geiger-Mueller (GM) tube detector to measure soil contamination levels reported in counts per minute (cpm). This paper presents a method to evaluate the theoretical best responses that could be obtained from surface contamination monitoring instrumentation for a known concentration (1 Bq/g) of various radionuclides. A static efficiency of cpm/Bq{sup -1} g{sup -1} is obtained from these calculations. These contamination monitoring sensitivities are then used in a MARSSIM scanning sensitivity equation and compared to the scanning sensitivity of an NaI(Tl) scintillation detector. The results demonstrate that the sensitivity of the frisker probes to particle radiations (betas for pancake) tend to fall in a range of only a few cpm/Bq{sup -1} g{sup -1}. Rather, the primary static response of the pancake probe to soil contamination is from gamma radiation where a value of 36 cpm/Bq{sup -1} g{sup -1} for Cs-137 was obtained at 2.54 cm distance without the application of scanning statistics. In comparison, a 7.6 cm x 7.6 cm NaI(Tl) detector has a Cs-137 static response factor of 10,000 cpm/Bq{sup -1} g{sup -1} at 15 cm distance without applying scanning statistics. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Intercomparison of gamma scattering, gammatography and radiography techniques for mild steel nonuniform corrosion detection

This paper focuses on the mild steel (MS) corrosion detection and intercomparison of results obtained by gamma scattering, gammatography, and radiography techniques. The gamma scattering non-destructive evaluation (NDE) method utilizes scattered gamma radiation for the detection of corrosion, and the scattering experimental setup is an indigenously designed automated personal computer (PC) controlled scanning system consisting of computerized numerical control (CNC) controlled six-axis source detector system and four-axis job positioning system. The system has been successfully used to quantify the magnitude of corrosion and the thickness profile of a MS plate with nonuniform corrosion, and the results are correlated with those obtained from the conventional gammatography and radiography imaging measurements. A simple and straightforward reconstruction algorithm to reconstruct the densities of the objects under investigation and an unambiguous interpretation of the signal as a function of material density at any point of the thick object being inspected is described. In this simple and straightforward method the density of the target need not be known and only the knowledge of the target material's mass attenuation coefficients (composition) for the incident and scattered energies is enough to reconstruct the density of the each voxel of the specimen being studied. The Monte Carlo (MC) numerical simulation of the phenomena is done using the Monte Carlo N-Particle Transport Code (MCNP) and the quantitative estimates of the values of signal-to-noise ratio for different percentages of MS corrosion derived from these simulations are presented and the spectra are compared with the experimental data. The gammatography experiments are carried out using the same PC controlled scanning system in a narrow beam, good geometry setup, and the thickness loss is estimated from the measured transmitted intensity. Radiography of the MS plates is carried out using 160 kV x-ray machine. The digitized radiographs with a resolution of 50 {mu}m are processed for the detection of corrosion damage in five different locations. The thickness losses due to the corrosion of the MS plate obtained by gamma scattering method are compared with those values obtained by gammatography and radiography techniques. The percentage thickness loss estimated at different positions of the corroded MS plate varies from 17.78 to 27.0, from 18.9 to 24.28, and from 18.9 to 24.28 by gamma scattering, gammatography, and radiography techniques, respectively. Overall, these results are consistent and in line with each other.

36 MATERIALS SCIENCE↗

SORIS - A standoff radiation imaging system

The detection of radiological and special nuclear material within the country’s borders is a crucial component of the national security network. Being able to detect small amounts of radiological material at large distances is especially important for search applications. To provide this capability General Electric’s Research Center has developed, as a part of DNDO’s standoff radiation detection system advanced technology demonstration (SORDS-ATD) program, a standoff radiation imaging system (SORIS). This vehicle-based system is capable of detecting weak sources at large distances in relatively short times. To accomplish this, GE has developed a novel coded aperture detector based on commercial components from GE Healthcare. An array of commercial gamma cameras modified to increase the system efficiency and energy range are used as position sensitive detectors. Unlike typical coded aperture systems, however, SORIS employs a non-planar mask and thus does not suffer the typical limitations of partially encoded regions giving it a wide field of view. Source identification is done using both low-statistics anomaly indicators and conventional high-statistics algorithms being developed by Pacific Northwest National Laboratory. The results of scanned areas and threats identified are displayed to the user and overlaid on satellite imagery.commercial components from GE Healthcare. An array of commercial gamma cameras modified to increase the system efficiency and energy range are used as position sensitive detectors. Unlike typical coded aperture systems, however, SORIS employs a non-planar mask and thus does not suffer the typical limitations of partially encoded regions giving it a wide field of view. Source identification is done using both low-statistics anomaly indicators and conventional high-statistics algorithms being developed by Pacific Northwest National Laboratory. The results of scanned areas and threats identified are displayed to the user and overlaid on satellite imagery.

Coded aperture imager↗

Synthesis of Mg{sub 2}SiO{sub 4}:Dy{sup 3+} nanoparticles by hydrothermal method and investigation of their thermo and photo luminescence properties

Highlights: • Mg{sub 2}SiO{sub 4}:Dy{sup 3+} nanoparticles have been prepared by hydrothermal and combustion methods. • Thermo and photo luminescent behavior of Mg{sub 2}SiO{sub 4}:Dy{sup 3+} was studied. • The effect of synthesis method on TL properties of Mg{sub 2}SiO{sub 4}:Dy{sup 3+} was investigated. • The optimal dopant concentration for thermo-luminescent property was obtained. - Abstract: In this study, photo and thermo-luminescent properties of Nano crystalline Mg{sub 2}SiO{sub 4}:Dy{sup 3+} prepared by a hydrothermal method were studied and compared to those of nanoparticles prepared by combustion method. The synthesized sample was characterized by X-ray diffraction, transmission electron microscopy, scanning electron microscopy and photoluminescence spectroscopy. The effect of Dy concentration on photo and thermoluminescent intensities was studied. The X-ray diffraction (XRD) patterns of the samples revealed that forsterite was formed as a major phase for all the samples. The crystallite size was found to be in the range of 20–50 nm. The thermo luminescent glow curve indicated that the hydrothermal sample was more efficient than the combustion sample. Two prominent TL bands located at 200 nm and 320 nm were recorded. The prepared nanoparticles exhibited a roughly linear dose response to absorbed dose of 1000 Gy received from 60Co gamma source, suggesting that nanomaterial could be a good candidate for high dose dosimetry.

36 MATERIALS SCIENCE↗

Characterization of the interaction layer in diffusion couples U-7 wt.%Mo/Al 6061 alloy at 550 deg. C and 340 deg. C

Solid state reaction between U-7 wt.%Mo and Al 6061 alloys at 550 deg. C and 340 deg. C was characterized in chemical diffusion couples made by Friction Stir Welding. Results were obtained from optical and scanning electron microscopy, electron probe microanalysis and X-ray diffraction. At 550 deg. C the interaction layer in {gamma}U(Mo)/Al 6061 is formed by U(Al,Si){sub 3} phase but when {gamma}U(Mo) cellular decomposition occurs, UAl{sub 3} and Al{sub 43}Mo{sub 4}U{sub 6} also appear in the interaction layer. At 340 deg. C the use of X-ray diffraction with synchrotron radiation made it possible to analyze the interaction layer. It was found that it is only formed by U{sub 3}Si{sub 5} phase with its cell volume enlarged respect to the original one.

36 MATERIALS SCIENCE↗

Corrosion Behavior of 316L Stainless Steel Fabricated by Selective Laser Melting Under Different Scanning Speeds

This work discussed the effects of different scanning speeds (800, 1083, 1200 and 1400 mm/s) on the microstructure of 316L stainless steel manufactured by selective laser melting (SLM) and the related corrosion behavior. Results showed that there were more voids with faster scanning speeds, and there were oxide powder and non-melt silicon inside the defects. The SLM 316L exhibited a full gamma austenite phase filled with sub-grains, and the average grain size of SLM-1083 mm/s 316L was approximately 42 μm, three times larger than that of the quenched 316L. The pitting potentials for the SLM 316L were all approximately 300 mV higher than that of the quenched due to the modification of inclusions in SLM, but the corrosion rate for the SLM 316L was faster, which was attributed to the voids and unstable passive film. The number of pitting sites increased with the scanning speed, and the pits occurred preferentially at the voids in SLM 316L.

36 MATERIALS SCIENCE↗

Variations in dose distribution and optical properties of Gafchromic{sup TM} EBT2 film according to scanning mode

Purpose: The authors aim was to investigate the effects of using transmission and reflection scanning modes, the film orientation during scanning, and ambient room light on a dosimetry system based on the Gafchromic{sup TM} EBT2 film model. Methods: For calibration, the films were cut to 3 x 3 cm{sup 2} and irradiated from 20 to 700 cGy at the depth of maximum dose using 6 and 10 MV photon beams in a 10 x 10 cm{sup 2} field size. Absolute dose calibration of the linear accelerator was done according to the TRS398 protocol. An FG65-G ionization chamber was used to monitor the dose while irradiating the films in solid water. The film pieces were scanned with an EPSON Expression 1680 Pro flatbed scanner in transmission and reflection modes. Authors investigated the effect of orientation on films and examined the optical properties of EBT2 film using an ellipsometer and an ultraviolet (UV)/visible spectrometer to explain the dosimetric dependence of the film on orientation during the scanning process. To investigate the effect of ambient room light, films were preirradiated in 6 and 10 MV photon beams with intensity-modulated radiotherapy (IMRT) quality assurance (QA) plans, and then exposed to room light, either directly for 2 days in a workroom or for 2 months in a film box. Gamma index pass criteria of (3%, 3 mm) were used. Results: The dose response curves based on net optical density (NOD) indicated that the reflection scanning mode can provide a better dose sensitivity than the transmission scanning mode, whereas the standard deviation of the dose is greater in reflection mode than in transmission mode. When the film was rotated 90 deg. from the portrait orientation, the average dose of the EBT2 film decreased by 11.5-19.6% in transmission mode and by 1.5-2.3% in reflection mode. Using an ellipsometer, variation of the refractive index of EBT2 film--the birefringence property--was found to be the largest between 45 deg. (1.72 and 1.71) and 135 deg. (1.8 and 1.77) for 300 and 800 cGy. Absorption spectra of EBT2 films measured with spectrometer were the function of film orientation. The readings in reflection scanning mode were more stable against room light than those in transmission scanning mode, although dose readings increased in both modes after the films were exposed to room light. Conclusions: The transmission scanning mode exhibited a strong dependence on film orientation during scanning and a change in optical density resulting from room light exposure, so a constant scanning orientation and minimal exposure to light can reduce uncertainty in the measured dose (23 {+-} 3%). The angular dependence was analyzed using Jones matrices and optical properties of EBT2 film were obtained using an ellipsometer and an UV/visible spectrometer. The reflection scanning mode has relatively good stability with respect to room light and film orientation on a scanner, although the large standard deviation of dose is a disadvantage in measurements of absolute dose. Reflection scanning mode can offer a potential advantage for film dosimetry in radiotherapy, although transmission scanning mode is still recommended for dosimetry as it provides better uncertainty results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oligoethylene-bridged diferrocene on Ag(110): Monolayer structures and adsorbate-induced faceting

The self-assembly of a ferrocene (Fc) derivative, oligoethylene-bridged diferrocene (diFc), Fc(CH{sub 2}){sub 14}Fc, on Ag(110) surface has been investigated by scanning tunneling microscopy (STM) under ultrahigh vacuum. Three ordered structures, the majority {beta} and the minorities {alpha} and {gamma}, are formed at monolayer coverage. In {alpha} and {gamma}, a unit cell contains one molecule and the molecules are parallel to each other so that the distances between Fc groups and between oligoethylene chains are reduced. A unit cell contains five molecules in {beta}: four of them are parallel to each other but not parallel to the fifth. The interaction between diFc and Ag(110), which is relatively strong in comparison to the intermolecular interaction, is dominant for the assembly of the ordered structures. The adsorption of diFc molecules induces the reorganization of substrate steps, which prefer to follow the directions of the superstructure lattice vectors, i.e. ({+-}1,2) and ({+-}3,2) of the Ag(110) surface. The (12 13-1) facet is formed due to step bunching at regions with high step density. By using in situ STM, the process of step reorganization and faceting has been observed in real time. It is concluded that the Ag adatoms play a key role on the substrate reorganization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fermi 130 GeV gamma-ray excess and dark matter annihilation in sub-haloes and in the Galactic centre

We analyze publicly available Fermi-LAT high-energy gamma-ray data and confirm the existence of clear spectral feature peaked at E{sub γ} = 130 GeV. Scanning over the Galaxy we identify several disconnected regions where the observed excess originates from. Our best optimized fit is obtained for the central region of Galaxy with a clear peak at 130 GeV with local statistical significance 4.5σ. The observed excess is not correlated with Fermi bubbles. We compute the photon spectra induced by dark matter annihilations into two and four standard model particles, the latter via two light intermediate states, and fit the spectra with data. Since our fits indicate sharper and higher signal peak than in the previous works, data favors dark matter direct two-body annihilation channels into photons or other channels giving only line-like spectra. If Einasto halo profile correctly predicts the central cusp of Galaxy, dark matter annihilation cross-section to two photons is of order ten percent of the standard thermal freeze-out cross-section. The large dark matter two-body annihilation cross-section to photons may signal a new resonance that should be searched for at the CERN LHC experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Root cause analysis and solutions for plastic gamma detector degradation in challenging environments—An overview

Polyvinyl toluene (PVT) plastic is often used to make gamma ray sensitive scintillators and is used in many important applications. For example, PVT is used to scan recycled steel going into a plant to be processed. It is also used in personnel portals to scan employees, and is used at the borders of many countries to scan cargo and cars passing through. In recent years, it was discovered that PVT can become degraded when it absorbs water and then is subjected to daily temperature swings, as is evidence by a reduction in scintillation light. Water absorption by PVT was notionally associated with temporary fogging (i.e., a rapid decrease in opacity which was reversible over time) and permanent fogging (i.e., permanent crack-like defects) and was for some time suspected to be the leading cause of the fogging due to circumstantial evidence. However, definitive proof was not established and in particular the specific mechanisms by which water entered the plastic and ultimately created temporary and permanent point-like defects was not fully understood. This paper is an overview of an effort initiated to reveal the fundamental root cause and also the dynamics of the fogging and degradation processes. This understanding is important not only to solve degradation problems for PVT in fielded systems, but also (1) to provide direction for future procurements for new equipment, and (2) to provide direction for future R&D efforts into advanced plastics with enhanced spectroscopic capabilities or dual particle gamma/neutron capabilities. Unexpected outcomes of this investigation included (1) the capability to predict the onset of fogging based on models using weather data alone, and (2) new modified formulations of PVT and PS which are fog-resistant. This paper provides an overview of the water uptake and associated mechanisms for various compositions, characterization of resulting temporary and permanent defects, predictive modeling of fogging, and possible solutions including encapsulation, heaters and new formulations. While this paper is an overview of the root cause analysis and solution, five accompanying papers (Lance et al., 2018, Myllenbeck and Feng, 2018, Payne et al., 2018, Zaitseva et al. 2018, Kouzes et al., 2018) from the same conference (SORMA 2018) delve further into the details and also expand upon the scope of what will be reported herein.

36 MATERIALS SCIENCE↗

An approach towards plastic scintillators from thermally activated delayed fluorescent dyes and cross-linkable bismuth compounds

Cross-linked polyvinyltoluene (PVT) based plastic scintillators loaded with dyes exhibiting thermally activated delayed fluorescence (TADF) and various amounts of (caproate)di-(methacrylate) bismuth (CMB) were developed. The co-polymerization of vinyl toluene monomer loaded with different weight ratios of CMB and 1 wt% of TADF dye yielded highly transparent cross-linked plastic scintillators with intense green photoluminescence. The thermal and mechanical properties of the scintillators were investigated using thermogravimetric analysis (TGA), differential scanning calorimetry (DSC) and micro indentation techniques. Here, their performance for radiation detection was assessed by performing gamma spectroscopy using a Cs-137 source and benchmarked to commercial plastic scintillators. The loading of CMB was guided by Monte Carlo N-Particle (MCNP) simulations. The results of this study show that the cross-linking approach and the use of TADF dyes yield scintillators with good mechanical properties with a uniaxial yield strength up to ~66 MPa for compositions loaded with 40 wt% of CMB and high optical quality. However, the light yield in gamma spectroscopy experiments is found to be reduced with the addition of CMB, suggesting a trade-off between mechanical yield strength and light yield in gamma spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-D-207B-01: A Prediction Model for Distinguishing Radiation Necrosis From Tumor Progression After Gamma Knife Radiosurgery Based On Radiomics Features From MR Images

Purpose: To develop and validate a prediction model using radiomics features extracted from MR images to distinguish radiation necrosis from tumor progression for brain metastases treated with Gamma knife radiosurgery. Methods: The images used to develop the model were T1 post-contrast MR scans from 71 patients who had had pathologic confirmation of necrosis or progression; 1 lesion was identified per patient (17 necrosis and 54 progression). Radiomics features were extracted from 2 images at 2 time points per patient, both obtained prior to resection. Each lesion was manually contoured on each image, and 282 radiomics features were calculated for each lesion. The correlation for each radiomics feature between two time points was calculated within each group to identify a subset of features with distinct values between two groups. The delta of this subset of radiomics features, characterizing changes from the earlier time to the later one, was included as a covariate to build a prediction model using support vector machines with a cubic polynomial kernel function. The model was evaluated with a 10-fold cross-validation. Results: Forty radiomics features were selected based on consistent correlation values of approximately 0 for the necrosis group and >0.2 for the progression group. In performing the 10-fold cross-validation, we narrowed this number down to 11 delta radiomics features for the model. This 11-delta-feature model showed an overall prediction accuracy of 83.1%, with a true positive rate of 58.8% in predicting necrosis and 90.7% for predicting tumor progression. The area under the curve for the prediction model was 0.79. Conclusion: These delta radiomics features extracted from MR scans showed potential for distinguishing radiation necrosis from tumor progression. This tool may be a useful, noninvasive means of determining the status of an enlarging lesion after radiosurgery, aiding decision-making regarding surgical resection versus conservative medical management.

60 APPLIED LIFE SCIENCES↗