Spacecraft temperature-control coatings - selection, utilization, and problems related to the space environment.
Spacecraft surface temperature-control coating requirements, selection and performance in prelaunch and space environments
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Spacecraft surface temperature-control coating requirements, selection and performance in prelaunch and space environments
Spacecraft surface temperature-control coating requirements, selection and performance in prelaunch and space environments
Selected bibliography and abstracts of high temperature optical properties and measurements
Purpose: Preclinical animal models of lung cancer can provide a controlled test-bed for testing dose escalation or function-based-treatment-planning studies. However, to extract lung function, i.e. ventilation, one needs to be able to image the lung at different phases of ventilation (in-hale / ex-hale). Most respiratory-gated imaging using micro-CT involves using an external ventilator and surgical intervention limiting the utility in longitudinal studies. A new intrinsic respiratory retrospective gating method was developed and tested in mice. Methods: A fixed region of interest (ROI) that covers the diaphragm was selected on all projection images to estimate the mean intensity (M). The mean intensity depends on the projection angle and diaphragm position. A 3-point moving average (A) of consecutive M values: Mpre, Mcurrent and Mpost, was calculated to be subtracted from Mcurrent. A fixed threshold was used to enable amplitude based sorting into 4 different phases of respiration. Images at full-inhale and end-exhale phases of respiration were reconstructed using the open source OSCaR. Lung volumes estimated at the 2 phases of respiration were validated against literature values. Results: Intrinsic retrospective gating was accomplished without the use of any external breathing waveform. While projection images were acquired at 360 different angles. Only 138 and 104 projections were used to reconstruct images at full-inhale and end-exhale. This often results in non-uniform under-sampled angular projections leading to some minor streaking artifacts. The calculated expiratory, inspiratory and tidal lung volumes correlated well with the values known from the literature. Conclusion: Our initial result demonstrates an intrinsic gating method that is suitable for flat panel cone beam small animal CT systems. Reduction in streaking artifacts can be accomplished by oversampling the data or using iterative reconstruction methods. This initial experience will enable freebreathing small animal micro-CT imaging to fuel longitudinal studies of lung function.
Purpose: To investigate the effects of breathing variation on gating window internal target volume (ITV{sub GW}) in respiratory gated radiation therapy. Method and Materials: Two-dimensional dynamic MRI (dMRI) of lung motion was acquired in ten volunteers and eight lung cancer patients. Resorted dMRI using 4DCT acquisition method (RedCAM) was generated for selected subjects by simulating the image rebinning process. A dynamic software generated phantom (dSGP) was created by moving a solid circle (to mimic the ''tumor'') with dMRI-determined motion trajectories. The gating window internal target area (ITA{sub GW}, 2D counterpart of ITV{sub GW}) was determined from both RedCAM and dSGP/dMRI. Its area (A), major axis (L1), minor axis (L2), and similarity (S) were calculated and compared. Results: In the phantom study of 3 cm tumor, measurements of the ITA{sub GW} from dSGP (A=10.0{+-}1.3 cm{sup 2}, L1=3.8{+-}0.4 cm, and L2=3.3{+-}0.1 cm) are significantly (p<0.001) greater than those from RedCAM (A=8.5{+-}0.7 cm{sup 2}, L1=3.5{+-}0.2 cm, and L2=3.1{+-}0.1 cm). Similarly, the differences are significantly greater (p<0.001) for the 1 cm tumor (A=1.9{+-}0.5 cm{sup 2}, L1=1.9{+-}0.4 cm, and L2=1.3{+-}0.1 cm in dSGP; A=1.3{+-}0.1 cm{sup 2}, L1=1.5{+-}0.2 cm, and L2=1.1{+-}0.1 cm in RedCAM). In patient studies, measurements of the ITA{sub GW} from dMRI (A=15.5{+-}8.2 cm{sup 2}, L1=5.0{+-}1.1 cm, and L2=3.8{+-}1.2 cm) are also significantly greater (p<0.05) than those from RedCAM (A=13.2{+-}8.5 cm{sup 2}, L1=4.3{+-}1.4 cm, and L2=3.7{+-}1.2 cm). Similarities were 0.9{+-}0.1, 0.8{+-}0.1, and 0.8{+-}0.1 in the 3 cm tumor phantom, 1 cm tumor phantom, and patient studies, respectively. Conclusion: ITV{sub GW} can be underestimated by 4DCT due to breathing variations. An additional margin may be needed to account for this potential error in generating a PTV{sub GW}. Cautions need to be taken when generating ITV{sub GW} from 4DCT in respiratory gated radiation therapy, especially for small tumors (<3 cm) with a large motion range (>1 cm).
Spider venom toxins, such as Protoxin-II (ProTx-II), have recently received much attention as selective Na v 1.7 channel blockers, with potential to be developed as leads for the treatment of chronic nocioceptive pain. ProTx-II is a 30-amino acid peptide with three disulfide bonds that has been reported to adopt a well-defined inhibitory cystine knot (ICK) scaffold structure. Potential drawbacks with such peptides include poor pharmacodynamics and potential scrambling of the disulfide bonds in vivo . In order to address these issues, in the present study we report the solid-phase synthesis of lanthionine-bridged analogues of ProTx-II, in which one of the three disulfide bridges is replaced with a thioether linkage, and evaluate the biological properties of these analogues. We have also investigated the folding and disulfide bridging patterns arising from different methods of oxidation of the linear peptide precursor. Finally, we report the X-ray crystal structure of ProTx-II to atomic resolution; to our knowledge this is the first crystal structure of an ICK spider venom peptide not bound to a substrate.
Channelrhodopsins (ChR) are light-sensitive cation channels used in optogenetics, a technique that applies light to control cells (e.g., neurons) that have been modified genetically to express those channels. Although mutations are known to affect pore kinetics, little is known about how mutations induce changes at the molecular scale. To address this issue, we first measured channel opening and closing rates of a ChR chimera (C1C2) and selected variants (N297D, N297V, and V125L). Then, we used atomistic simulations to correlate those rates with changes in pore structure, hydration, and chemical interactions among key gating residues of C1C2 in both closed and open states. Overall, the experimental results show that C1C2 and its mutants do not behave like ChR2 or its analogous variants, except V125L, making C1C2 a unique channel. Furthermore, our atomistic simulations confirmed that opening of the channel and initial hydration of the gating regions between helices I, II, III, and VII of the channel occurs with 1) the presence of 13-cis retinal; 2) deprotonation of a glutamic acid gating residue, E129; and 3) subsequent weakening of the central gate hydrogen bond between the same glutamic acid E129 and asparagine N297 in the central region of the pore. Also, an aspartate (D292) is the unambiguous primary proton acceptor for the retinal Schiff base in the hydrated channel.
A detector test facility was developed and applied in the evaluation and characterization of lidar detectors in support of the multipurpose airborne differential absorption lidar (DIAL) system based at the Langley Research Center (LaRC). A performance data base of various detector configurations available to the DIAL system was obtained for optimum lidar detector selection. Photomultiplier tubes (PMT's) with multialkaline and bialkaline photocathodes were evaluated in voltage-divider networks (bases) by using either the focusing electrode or dynodes as a gating mechanism. Characteristics used for detector evaluation included gain stability, signal rise time, and the ability to block unwanted high light levels.
Fixed-frequency transmon quantum computers (QCs) have advanced in coherence times, addressability, and gate fidelities. Unfortunately, these devices are restricted by the number of on-chip qubits, capping processing power and slowing progress toward fault-tolerance. Although emerging transmon devices feature over 100 qubits, building QCs large enough for meaningful demonstrations of quantum advantage requires overcoming many design challenges. For example, today’s transmon qubits suffer from significant variation due to limited precision in fabrication. As a result, barring significant improvements in current fabrication techniques, scaling QCs by building ever larger individual chips with more qubits is hampered by device variation. Severe device variation that degrades QC performance is referred to as a defect. Here, we focus on a specific defect known as a frequency collision. When transmon frequencies collide, their difference falls within a range that limits two-qubit gate fidelity. Frequency collisions occur with greater probability on larger QCs, causing collision-free yields to decline as the number of on-chip qubits increases. As a solution, we propose exploiting the higher yields associated with smaller QCs by integrating quantum chiplets within quantum multi-chip modules (MCMs). Yield, gate performance, and application-based analysis show the feasibility of QC scaling through modularity. Our results demonstrate that chiplet architectures, relative to monolithic designs, benefit from average yield improvements ranging from 9.6 – 92.6 × for ≲5 qubit machines. In addition, our simulations explore the design space of chiplet systems and discover configurations that demonstrate average two-qubit gate infidelity reductions that are at best 0.815 × their monolithic counterpart. Lastly, we observe that carefully-selected modular systems achieve fidelity improvements on a range of benchmark circuits.
Purpose: Despite multiple methodologies already proposed to correct respiratory motion in the whole PET imaging field of view (FOV), such approaches have not found wide acceptance in clinical routine. An alternative can be the local respiratory motion correction (LRMC) of data corresponding to a given volume of interest (VOI: organ or tumor). Advantages of LRMC include the use of a simple motion model, faster execution times, and organ specific motion correction. The purpose of this study was to evaluate the performance of LMRC using various motion models for oncology (lung lesion) applications. Methods: Both simulated (NURBS based 4D cardiac-torso phantom) and clinical studies (six patients) were used in the evaluation of the proposed LRMC approach. PET data were acquired in list-mode and synchronized with respiration. The implemented approach consists first in defining a VOI on the reconstructed motion average image. Gated PET images of the VOI are subsequently reconstructed using only lines of response passing through the selected VOI and are used in combination with a center of gravity or an affine/elastic registration algorithm to derive the transformation maps corresponding to the respiration effects. Those are finally integrated in the reconstruction process to produce a motion free image over the lesion regions. Results: Although the center of gravity or affine algorithm achieved similar performance for individual lesion motion correction, the elastic model, applied either locally or to the whole FOV, led to an overall superior performance. The spatial tumor location was altered by 89% and 81% for the elastic model applied locally or to the whole FOV, respectively (compared to 44% and 39% for the center of gravity and affine models, respectively). This resulted in similar associated overall tumor volume changes of 84% and 80%, respectively (compared to 75% and 71% for the center of gravity and affine models, respectively). The application of the nonrigid deformation model in LRMC led to over an order of magnitude gain in computational efficiency of the correction relative to the application of the deformable model to the whole FOV. Conclusions: The results of this study support the use of LMRC as a flexible and efficient correction approach for respiratory motion effects for single lesions in the thoracic area.
The transport of protons across membranes is an essential process for both bioenergetics of modem cells and the origins of cellular life. All living systems make use of proton gradients across cell walls to convert environmental energy into a high-energy chemical compound, adenosine triphosphate (ATR), synthesized from adenosine diphosphate. ATR, in turn, is used as a source of energy to drive many cellular reactions. The ubiquity of this process in biology suggests that even the earliest cellular systems were relying on proton gradient for harvesting environmental energy needed to support their survival and growth. In contemporary cells, proton transfer is assisted by large, complex proteins embedded in membranes. The issue addressed in this study was: how the same process can be accomplished with the aid of similar, but much simpler molecules that could have existed in the protobiological milieu? The model system used in the study contained a bilayer membrane made of phospholipid, dimyristoylphosphatidylcholine (DMPC), which is a good model of the biological membranes focusing cellular boundaries. Both sides of the bilayer were surrounded by water which simulated the environment inside and outside the cell. Embedded in the membrane was a fragment of the Influenza-A M2 protein and enough sodium counterions to maintain system neutrality. This protein has been shown to exhibit remarkably high rates of proton transport and, therefore, is an excellent model to study the formation of proton gradients across membranes. The Influenza M2 protein is 97 amino acids in length, but a fragment 25 amino acids long, which contains a transmembrane domain of 19 amino acids flanked by 3 amino acids on each side, is sufficient to transport protons. Four identical protein fragments, each folded into a helix, aggregate to form small channels spanning the membrane. Protons are conducted through a narrow pore in the middle of the channel in response to applied voltage. This channel is large enough to contain water molecules, and is normally filled with water. In analogy to the mechanism of proton transfer in some other channels, it has been postulated that protons are translocated along the network of water molecules filling the pore of the channel. This mechanism, however, must involve an additional, important step because the channel contains four histidine amino acid residues, one from each of the helices, which are sufficiently large to occlude the pore and interrupt the water network. The histidine residues ensure channel selectivity by blocking transport of small such as sodium or potassium. They have been also implicated in gating protons due to the ability of each histidine to become positively charged by accepting an additional proton. Two mechanisms of gating have been proposed. In one mechanism, all four histidines acquire an additional proton and, due to repulsion between their positive charges, move away from one another, thus opening the channel. The alternative mechanism relies of the ability of protons to move between different atoms in a molecule (tautomerization). Thus, a proton is captured on one side of the gate while another proton is released from the opposite side, and the molecule returns to the initial state through tautomerization. The simulations were designed to test these two mechanisms. Large-scale, atomic-level molecular dynamics simulations of the channel, in which the histidine residues were in different protonation states revealed that all intermediate states of the system involved in the tautomerization mechanism are structurally stable and the arrangement of water molecules in the channel is conducive to the proton transport. In contrast, in the four-protonated state, postulated to exist in the gate-opening mechanism, the electrostatic repulsion between the histidine residues appears to be so large that the channel looses its structural integrity and one helix moves away from the remaining three. This result indicates that such a mechanism of proton transport is unlikely. The simulations revealed that translocation along a network of water molecules in the channel and tautomerization of the histidine residues in the M2 proteins in the most likely mechanism of proton transport. The results not only explain how a remarkably simple protein system can efficiently aid in the formation of proton gradients across cell walls, but also suggest how this system can be genetically re-engineered to become a directional, reversible proton pump. Such a pump can provide energy to laboratory-built models of simple cellular systems. If they were successfully constructed it would greatly advance our understanding of the beginnings of life and find important applications in medicine and pharmacology.
Purpose: To evaluate the effect of breathing irregularities on target location in gated treatments using amplitude and phase gating. Methods: 111 breathing patterns acquired using RPM system were categorized based on period and amplitude STD as regular (STD period ≤ 0.5 s, STD amplitude ≤ 1.5 mm), medium (0.5 s < STD period ≤ 1 s, 1.5 mm < STD amplitude ≤ 3 mm) and irregular (STD period > 1 s, STD amplitude > 3 mm). One pattern representative of the average defined population was selected per category and corresponding target motion reproduced using Quasar Respiratory Motion Phantom. Phantom in motion underwent 4D-CT scan with phase reconstruction. Gated window was defined at end of exhale and DRRs reconstructed in treatment planning at 40% (beam on) and 60% phase (beam off). Target location uncertainty was assessed by comparing gated kV triggered images continuously acquired at beam on/off on a True Beam 2.0 with corresponding DRRs. Results: Average target uncertainty with amplitude gating was in [0.4 – 1.9] mm range for the different scenarios with maximum STD of 1.2 mm for the irregular pattern. Average target uncertainty with phase gating was [1.1 – 2.2] mm for regular and medium patterns, while it increased to [3.6 – 9.6] mm for the irregular pattern. Live gated motion was stable with amplitude gating, while increasing with phase gating for the irregular pattern. Treatment duration range was [68 – 160] s with amplitude and [70 – 74] s with phase gating. Conclusion: Breathing irregularities were found to affect gated treatments only when using phase gating. For regular and medium patterns no significant difference was found between the two gating strategies. Amplitude gating ensured stable gated motion within the different patterns, thus reducing intra-fraction target location variability for the irregular pattern and resulting in longer treatment duration.
Quantum circuits can be reduced through optimization to better fit the constraints of quantum hardware. One such method, initial-state dependent optimization (ISDO), reduces gate count by leveraging knowledge of the input quantum states. Surprisingly, we found that ISDO is broadly applicable to the downstream circuits produced by circuit cutting. Circuit cutting also requires measuring upstream qubits and has some flexibility of selection observables to do reconstruction. Therefore, we propose a state-dependent optimization (SDO) framework that incorporates ISDO, our newly proposed measure-state dependent optimization (MSDO), and a biased observable selection strategy. Building on the strengths of the SDO framework and recognizing the scalability challenges of circuit cutting, we propose nonseparate circuit cutting-a more flexible approach that enables optimizing gates without fully separating them. We validate our methods on noisy simulations of QAOA, QFT, and BV circuits. Results show that our approach consistently mitigates noise and improves overall circuit performance, demonstrating its promise for enhancing quantum algorithm execution on near-term hardware.
A new VMEDAC64, 12-bit 64 channel digital-to-analog converter, a Versa Module Europa (VME) module, features 64 analog voltage outputs with user selectable multiple ranges, has been developed for control system applications at Inter University Accelerator Centre. The FPGA (Field Programmable Gate Array) is the module's core, i.e., it implements the DAC control logic and complexity of VMEbus slave interface logic. The VMEbus slave interface and DAC control logic are completely designed and implemented on a single FPGA chip to achieve high density of 64 channels in a single width VME module and will reduce the module count in the control system applications, and hence will reduce the power consumption and cost of overall system. One of our early design goals was to develop the VME interface such that it can be easily integrated with the peripheral devices and satisfy the timing specifications of VME standard. The modular design of this module reduces the amount of time required to develop other custom modules for control system. The VME slave interface is written as a single component inside FPGA which will be used as a basic building block for any VMEbus interface project. The module offers multiple output voltage ranges depending upon the requirement. The output voltage range can be reduced or expanded by writing range selection bits in the control register. The module has programmable refresh rate and by default hold capacitors in the sample and hold circuit for each channel are charged periodically every 7.040 ms (i.e., update frequency 284 Hz). Each channel has software controlled output switch which disconnects analog output from the field. The modularity in the firmware design on FPGA makes the debugging very easy. On-board DC/DC converters are incorporated for isolated power supply for the analog section of the board.
An automated method for evaluating the image quality of calcified plaques with respect to motion artifacts in noncontrast-enhanced cardiac computed tomography (CT) images is introduced. This method involves using linear regression (LR) and artificial neural network (ANN) regression models for predicting two patient-specific, region-of-interest-specific, reconstruction-specific and temporal phase-specific image quality indices. The first is a plaque motion index, which is derived from the actual trajectory of the calcified plaque and is represented on a continuous scale. The second is an assessability index, which reflects the degree to which a calcified plaque is affected by motion artifacts, and is represented on an ordinal five-point scale. Two sets of assessability indices were provided independently by two radiologists experienced in evaluating cardiac CT images. Inputs for the regression models were selected from 12 features characterizing the dynamic, morphological, and intensity-based properties of the calcified plaques. Whereas LR-velocity (LR-V) used only a single feature (three-dimensional velocity), the LR-multiple (LR-M) and ANN regression models used the same subset of these 12 features selected through stepwise regression. The regression models were parameterized and evaluated using a database of simulated calcified plaque images from the dynamic NCAT phantom involving nine heart rate/multi-sector gating combinations and 40 cardiac phases covering two cardiac cycles. Six calcified plaques were used for the plaque motion indices and three calcified plaques were used for both sets of assessability indices. In one configuration, images from the second cardiac cycle were used for feature selection and regression model parameterization, whereas images from the first cardiac cycle were used for testing. With this configuration, repeated measures concordance correlation coefficients (CCCs) and associated 95% confidence intervals for the LR-V, LR-M, and ANN were 0.817 [0.785, 0.848], 0.894 [0.869, 0.916], and 0.917 [0.892, 0.936] for the plaque motion indices. For the two sets of assessability indices, CCC values for the ANN model were 0.843 [0.791, 0.877] and 0.793 [0.747, 0.828]. These two CCC values were statistically greater than the CCC value of 0.689 [0.648, 0.727], which was obtained by comparing the two sets of assessability indices with each other. These preliminary results suggest that the variabilities of assessability indices provided by regression models can lie within the variabilities of the indices assigned by independent observers. Thus, the potential exists for using regression models and assessability indices for determining optimal phases for cardiac CT image interpretation.
This chapter showcases selected illustrations of various manifestations of nanoscale and molecular electronic effects as investigated by quantum mechanical methods. The examples include results demonstrating (1) how graphitic nanoribbons can be assembled into multiterminal networks and the influence on electron transport; (2) how the position of a single embedded molecule can be modified to change the overall conduction state of a nanowire; (3) how carbon nanotubes can be assembled into complex covalent arrays and how these can be obtained experimentally; (4) how quantum interference can be understood as emerging from the presence of multiple levels of confinements in carbon nanorings; (5) how new functionality emerges at the nanoscale due to the interplay of magnetic, electronic, and structural properties of individual graphitic nanoribbons assembled into wiggle-like structures; and (6) how quantum chemical modeling can lead to the design of electrodes with enhanced interfaces for molecular coupling.
Purpose: GATE is a Monte Carlo simulation toolkit based on the Geant4 package, widely used for many medical physics applications, including SPECT and PET image simulation and more recently CT image simulation and patient dosimetry. The purpose of the current study was to calculate dose point kernels (DPKs) using GATE, compare them against reference data, and finally produce a complete dataset of the total DPKs for the most commonly used radionuclides in nuclear medicine. Methods: Patient-specific absorbed dose calculations can be carried out using Monte Carlo simulations. The latest version of GATE extends its applications to Radiotherapy and Dosimetry. Comparison of the proposed method for the generation of DPKs was performed for (a) monoenergetic electron sources, with energies ranging from 10 keV to 10 MeV, (b) beta emitting isotopes, e.g., {sup 177}Lu, {sup 90}Y, and {sup 32}P, and (c) gamma emitting isotopes, e.g., {sup 111}In, {sup 131}I, {sup 125}I, and {sup 99m}Tc. Point isotropic sources were simulated at the center of a sphere phantom, and the absorbed dose was stored in concentric spherical shells around the source. Evaluation was performed with already published studies for different Monte Carlo codes namely MCNP, EGS, FLUKA, ETRAN, GEPTS, and PENELOPE. A complete dataset of total DPKs was generated for water (equivalent to soft tissue), bone, and lung. This dataset takes into account all the major components of radiation interactions for the selected isotopes, including the absorbed dose from emitted electrons, photons, and all secondary particles generated from the electromagnetic interactions. Results: GATE comparison provided reliable results in all cases (monoenergetic electrons, beta emitting isotopes, and photon emitting isotopes). The observed differences between GATE and other codes are less than 10% and comparable to the discrepancies observed among other packages. The produced DPKs are in very good agreement with the already published data, which allowed us to produce a unique DPKs dataset using GATE. The dataset contains the total DPKs for {sup 67}Ga, {sup 68}Ga, {sup 90}Y, {sup 99m}Tc, {sup 111}In, {sup 123}I, {sup 124}I, {sup 125}I, {sup 131}I, {sup 153}Sm, {sup 177}Lu {sup 186}Re, and {sup 188}Re generated in water, bone, and lung. Conclusions: In this study, the authors have checked GATE's reliability for absorbed dose calculation when transporting different kind of particles, which indicates its robustness for dosimetry applications. A novel dataset of DPKs is provided, which can be applied in patient-specific dosimetry using analytical point kernel convolution algorithms.
Ribonucleotides and 2'-deoxyribonucleotides are the basic units for RNA and DNA, respectively, and the only difference is the extra 2'-OH group on the ribonucleotide sugar. Cellular rNTP concentrations are much higher than those of dNTP. When copying DNA, DNA polymerases not only select the base of the incoming dNTP to form a Watson-Crick pair with the template base but also distinguish the sugar moiety. Some DNA polymerases use a steric gate residue to prevent rNTP incorporation by creating a clash with the 2'-OH group. Y-family human DNA polymerase η (hpol η) is of interest because of its spacious active site (especially in the major groove) and tolerance of DNA lesions. Here, we show that hpol η maintains base selectivity when incorporating rNTPs opposite undamaged DNA and the DNA lesions 7,8-dihydro-8-oxo-2'-deoxyguanosine and cyclobutane pyrimidine dimer but with rates that are 103-fold lower than for inserting the corresponding dNTPs. X-ray crystal structures show that the hpol η scaffolds the incoming rNTP to pair with the template base (dG) or 7,8-dihydro-8-oxo-2'-deoxyguanosine with a significant propeller twist. As a result, the 2'-OH group avoids a clash with the steric gate, Phe-18, but the distance between primer end and Pα of the incoming rNTP increases by 1 Å, elevating the energy barrier and slowing polymerization compared with dNTP. In addition, Tyr-92 was identified as a second line of defense to maintain the position of Phe-18. Lastly, this is the first crystal structure of a DNA polymerase with an incoming rNTP opposite a DNA lesion.