Search NASA⌕ Search

SEARCH · Search NASA

Results for “Green's function methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

294 records · Page 17

Precise Heater Controller with rf-Biased Josephson Junctions

Paramagnetic susceptibility thermometers used in fundamental physics experiments are capable of measuring temperature changes with a precision of a part in 2 x 10(exp 10). However, heater controllers are only able to control open-loop power dissipation to about a part in 10(exp 5). We used an array of rf-biased Josephson junctions to precisely control the electrical power dissipation in a heater resistor mounted on a thermally isolated cryogenic platform. Theoretically, this method is capable of controlling the electrical power dissipation to better than a part in 10(exp 12). However, this level has not yet been demonstrated experimentally. The experiment consists of a liquid helium cell that also functions as a high-resolution PdMn thermometer, with a heater resistor mounted on it. The cell is thermally connected to a temperature-controlled cooling stage via a weak thermal link. The heater resistor is electrically connected to the array of Josephson junctions using superconducting wire. An rf-biased array of capacitively shunted Josephson junctions drives the voltage across the heater. The quantized voltage across the resistor is Vn = nf(h/2e), where h is Planck's constant, f is the array biasing frequency, e is the charge of an electron, and n is the integer quantum state of the Josephson array. This results in an electrical power dissipation on the cell of Pn = (Vn)(sup 2/R), where R is the heater resistance. The change of the quantum state of the array changes the power dissipated in the heater, which in turn, results in the change of the cell temperature. This temperature change is compared to the expected values based on the known thermal standoff resistance of the cell from the cooling stage. We will present our initial experimental results and discuss future improvements. This work has been funded by the Fundamental Physics Discipline of the Microgravity Science Office of NASA, and supported by a no-cost equipment loan from Sandia National Laboratories.

Green, Colin J.↗

Leveraging Existing Mission Tools in a Re-Usable, Component-Based Software Environment

Emerging methods in component-based software development offer significant advantages but may seem incompatible with existing mission operations applications. In this paper we relate our positive experiences integrating existing mission applications into component-based tools we are delivering to three missions. In most operations environments, a number of software applications have been integrated together to form the mission operations software. In contrast, with component-based software development chunks of related functionality and data structures, referred to as components, can be individually delivered, integrated and re-used. With the advent of powerful tools for managing component-based development, complex software systems can potentially see significant benefits in ease of integration, testability and reusability from these techniques. These benefits motivate us to ask how component-based development techniques can be relevant in a mission operations environment, where there is significant investment in software tools that are not component-based and may not be written in languages for which component-based tools even exist. Trusted and complex software tools for sequencing, validation, navigation, and other vital functions cannot simply be re-written or abandoned in order to gain the advantages offered by emerging component-based software techniques. Thus some middle ground must be found. We have faced exactly this issue, and have found several solutions. Ensemble is an open platform for development, integration, and deployment of mission operations software that we are developing. Ensemble itself is an extension of an open source, component-based software development platform called Eclipse. Due to the advantages of component-based development, we have been able to vary rapidly develop mission operations tools for three surface missions by mixing and matching from a common set of mission operation components. We have also had to determine how to integrate existing mission applications for sequence development, sequence validation, and high level activity planning, and other functions into a component-based environment. For each of these, we used a somewhat different technique based upon the structure and usage of the existing application.

Greene, Kevin↗

Alternative, Green Processes for the Precision Cleaning of Aerospace Hardware

Precision cleaning is necessary to ensure the proper functioning of aerospace hardware, particularly those systems that come in contact with liquid oxygen or hypergolic fuels. Components that have not been cleaned to the appropriate levels may experience problems ranging from impaired performance to catastrophic failure. Traditionally, this has been achieved using various halogenated solvents. However, as information on the toxicological and/or environmental impacts of each came to light, they were subsequently regulated out of use. The solvent currently used in Kennedy Space Center (KSC) precision cleaning operations is Vertrel MCA. Environmental sampling at KSC indicates that continued use of this or similar solvents may lead to high remediation costs that must be borne by the Program for years to come. In response to this problem, the Green Solvents Project seeks to develop state-of-the-art, green technologies designed to meet KSCs precision cleaning needs.Initially, 23 solvents were identified as potential replacements for the current Vertrel MCA-based process. Highly halogenated solvents were deliberately omitted since historical precedents indicate that as the long-term consequences of these solvents become known, they will eventually be regulated out of practical use, often with significant financial burdens for the user. Three solvent-less cleaning processes (plasma, supercritical carbon dioxide, and carbon dioxide snow) were also chosen since they produce essentially no waste stream. Next, experimental and analytical procedures were developed to compare the relative effectiveness of these solvents and technologies to the current KSC standard of Vertrel MCA. Individually numbered Swagelok fittings were used to represent the hardware in the cleaning process. First, the fittings were cleaned using Vertrel MCA in order to determine their true cleaned mass. Next, the fittings were dipped into stock solutions of five commonly encountered contaminants and were weighed again showing typical contaminant deposition levels of approximately 0.00300g per part. They were then cleaned by the solvent or process being tested and then weighed a third time which allowed for the calculation of the cleaning efficiency of the test solvent or process.Based on preliminary experiments, five solvents (ethanol, isopropanol, acetone, ethyl acetate, and tert-butyl acetate) were down selected for further testing. When coupled with ultrasonic agitation, these solvents removed hydrocarbon contaminants as well as Vertrel MCA and showed improved removal of perfluorinated greases. Supercritical carbon dioxide did an excellent job dissolving each of the five contaminants but did a poor job of removing Teflon particles found in the perfluorinated greases. Plasma cleaning efficiency was found to be dependent on which supply gas was used, exposure time, and gas pressure. Under optimized conditions it was found that breathing air, energized to the plasma phase, was able to remove nearly 100% of the contamination.These findings indicate that alternative cleaning methods are indeed able to achieve precision levels of cleanliness. Currently, our team is working with a commercial cleaning company to get independent verification of our results. We are also evaluating the technical and financial aspects of scaling these processes to a size capable of supporting the future cleaning needs of KSC.

Vertrel MCA↗

Multiwavelength Variability and Correlation Studies of Mrk 421 During Historically Low X-ray and Y-ray Activity in 2015–2016

We report a characterization of the multiband flux variability and correlations of the nearby (z=0.031) blazar Markarian 421(Mrk 421) using data from Mets ̈ahovi, Swift, Fermi-LAT, MAGIC, FACT, and other collaborations and instruments from 2014November till 2016 June. Mrk 421 did not show any prominent flaring activity, but exhibited periods of historically low activity above 1 TeV (F>1TeV<1.7×10−12ph cm−2s−1) and in the 2–10 keV (X-ray) band (F2−10 keV<3.6×10−11erg cm−2s−1),during which the Swift-BAT data suggest an additional spectral component beyond the regular synchrotron emission. The highest flux variability occurs in X-rays and very high-energy (E>0.1 TeV)γ-rays, which, despite the low activity, show a significant positive correlation with no time lag. The HRkeV and HRTeV show the harder-when-brighter trend observed in many blazars, but the trend flattens at the highest fluxes, which suggests a change in the processes dominating the blazar variability. Enlarging our dataset with data from years 2007 to 2014, we measured a positive correlation between the optical and the GeV emission over a range of about 60 d centred at time lag zero, and a positive correlation between the optical/GeV and the radio emission over a range of about 60 d centred at a time lag of 43+9−6d. This observation is consistent with the radio-bright zone being located about 0.2 parsec downstream from the optical/GeV emission regions of the jet. The flux distributions are better described with a lognormal function in most of the energy bands probed, indicating that the variability in Mrk 421 is likely produced by a multiplicative process.

Mrk 421↗

Investigation of Hardware and Instrumentation to Measure Hand Grasp Activity with the Spacesuit Gloves

Introduction: During the 2022 suited injury summit, it was hypothesized that there will be concerns for hand and glove injuries for future exploration space missions, especially given the fact that the “total number of Extravehicular activity (EVA) hours and frequency” for lunar surface missions is expected to vastly increase [1]. It has been reported that the hands experienced the greatest “absolute numbers” of reported injuries and far exceeds other injuries during EVA [1, 2]. It was reported that the most fatiguing part of the surface EVA was the repetitive gripping tasks [3]. It was recommended that a “glove sub-team” be created to look at possible injury mechanism and mitigation strategies. Some of the recommendations that were suggested [1] are as follows: examine hand fatigue, utilize motion capture, examine the duration and frequency of hand movements, and identify frequent hand motions. We started assessing hardware and instrumentation to measure hand grasp activity in the pressurized glove environment. The purpose of this test was to perform a hardware evaluation for motion capture (MoCap) gloves obtained from StretchSense (Auckland, New Zealand). The specific gloves used were the Pro Fidelity and SuperSplay to determine the repeatability, reliability, feasibility, and useability inside of a pressurized gloved environment. Methods: The MoCap gloves were customized (e.g., battery/Bluetooth pack relocated to upper arm) to better suit the pressurized testing environment and protect the subject from unintentional injury (Fig. 1). Fourteen total subjects from different demographics (i.e., gender and pressurized glove experience level) participated in this test series. Testing included one session each of a baseline data collection (NASA Johnson Space Center (JSC) building 21) and a spacesuit glove box (Fig. 2 at JSC building 7 room 2027) data collection (under vacuum down to 4.3 psid), where each session lasted 3-5 hours. Controlled and reproducible tasks to systematically evaluate the repeatability and reliability of the hardware were performed during baseline data collection. Additionally, subjects performed simulated EVA-like tasks in a pressurized gloved environment. For all sessions, MoCap gloves were placed on each of the subjects’ hands and the signal from it, or the raw capacitance (Fig. 3), was analysed. The raw capacitance was used to estimate the open and closed hand states between the testing conditions and allow us to provide an offset caused by the pressurized environment. Results & Discussion: Initial observation with the bare hands (baseline) condition showed that the MoCap gloves appeared to track grasping and releasing of the fingers (opening and closing fist) with both high- and low-speed conditions, while adduction and abduction of the fingers were not relatively tracked. A hardware evaluation was done outside of the glove box to assess the reliability and repeatability of the MoCap glove. In one task, a point force was applied to various locations on the back of the hand. When the point force was applied to the space between the 1st digit and the pointer finger, there was a noticeable distortion to the MoCap data. Another task examining an increasing force from a 10 lb. sandbag applied to the back of the hand while lying flat on a table, showed a constant flat line with only a distortion when the weight was increased or added to the back of the hand. Fig. 3 shows an object relocation task where you can see when each individual finger “opened” and “closed” (changed position) when picking up and setting down the dumbbell. When the fingers were stationary, the signal remained relatively flat compared to the peaks and valleys that can be observed in Fig. 3. This study showed promising results and imperative input into an attempt to discriminate between hand states across various functional tasks and should be evaluated with context to the repeatability and reliability outcomes. Depending on the task done inside of the pressurized glove box environment and outside, the results appear to be affected by many different factors (i.e., drift, pressure, hand size, etc.). Significance: If this hardware proves to be reliable and repeatable in determining the open and closed hand states then this may provide critical insight into assisting in the characterization of the pressurized gloved environment and the effect on crew member exertion level. Ultimately, this tool will provide useful data for quantifying the repetitive nature of EVA training and tasks. Acknowledgments: The authors would like to acknowledge the NASA Mars Campaign Office for providing funding for this research. Lastly, thanks to all the engineers and technicians at NASA JSC who helped with this data collection. References: [1] Reiber, et al. (2022), NASA/TM-20220007605; [2] Scheuring, et al. (2009), Av., Sp., and Envir. Med. 80(2). [3] Scheuring, et al. (2007), NASA/TM–2007–214755.

Rachel L Thompson↗

Cleanroom Microbes Survive Drying, Vacuum, and Proton Irradiation

Introduction : The goal of planetary protection at NASA is to mitigate the risk of contaminating sensitive target bodies with biological life. While many cleaning procedures have been put in place to reduce bioburden on spacecraft, microbes are experts at evolving to survive harsh conditions. Specifically, the dry, low-nutrient environment of a cleanroom (commonly used for assembly of spacecraft) can represent an environment where extremophiles can survive. Methods : Scientists at NASA MSFC wished to gather a snapshot of the microbial population within a variety of cleanrooms on site. A study was undertaken to collect air, surface, and floor samples from clean-rooms and isolate unique morphologies. From this study, 95 isolates were collected and saved in a microbial library. About 86% of these were identified at least to a genus level. Following identification, 24 microbes were selected, based on a literature review, as potential extremophiles. These were grown in liquid cultures, diluted to a set optical density, washed with water, and then applied to a sterilized Kapton coupon. Droplets were allowed to dry overnight in a biosafety cabinet. Coupons were then installed in a pelletron and pumped down to high vacuum (~1E-6 Torr). Samples were then subjected 100 keV protons at a fluence of 2x10 15 p+/cm 2 up to 4x10 15 p+/cm 2 . Following exposure, samples were returned to the microbiology lab where they were pro-cessed by submerging in water, vortexing, and then plating either droplets or spread plates. Recovery data collected was qualitative with a ranking or +, minor, or – for growth. Some selected radiotolerant strains were sequenced using the Illumina sequencing platform. The resulting genomes were annotated with the Rapid Annotations using Subsystems Technology (RAST) server and analyzed for conserved and unique stress response relevant genomic signatures to identify clues related to specific tolerances. Results and Discussion : After five rounds of proton radiation, we narrowed our isolates to five, non-spore forming bacteria that demonstrated survival: Arthrobacter koreensis, Paenarthrobacter nitroguajacolicus, Mycetocola manganoxydans , and an Erwinia sp. Furthermore, we exposed these four microbes to 254 nm wavelength light at an intensity of 80 W/m 2 at a distance of ~18 cm for 10 minutes. Only A. koreensis demonstrated survival following UV exposure. Finally, we performed whole genome sequencing on the four strains to look for genetic markers of stress resistance. When we compared the genomes of the four strains, we found that genes coding for GGDEF and EAL domains with PAS/PAC sensors were only found in A. koreensis . These domains, modulated by PAS/PAC sensors, are hypothesized to facilitate survival under drying, desiccation, and proton irradiation. Drying and Desiccation : PAS domains sense hydration changes and modulate GGDEF and EAL domain activity to adjust c-di-GMP levels, enhancing resistance to desiccation. For instance, in Pseudomonas aeruginosa , the PAS domain of RbdA modulates activity under varying hydration conditions, affecting stress responses [1]. Proton Irradiation : Proton irradiation causes oxidative stress, leading to ROS generation. PAS domains detect this stress and modulate GGDEF and EAL domains to manage oxidative stress responses. In Shewanella , EAL domain proteins modulated by PAS sensors help bacteria adapt to extreme conditions [2]. These genes upregulate other stress response genes, protecting membrane function, protein stability, DNA repair, and antioxidant defenses. The modulation of c-di-GMP by PAS domains is crucial for bacterial adaptation to stress conditions, enabling dynamic physio-logical adjustments [3]. Understanding these mechanisms provides insights into bacterial stress responses and strategies for controlling bacterial growth [4]. Conclusions : These findings indicate that clean-rooms harbor extremophile microbes that may be able to survive conditions in deep space. Furthermore, while we identified certain stress-response genes that may be at least partly responsible for the phenotypes observed in this study, there are likely unidentified genes or characteristics about A. koreensis , and other bacteria, that may allow them to survive in harsh environments. Future studies will focus on identifying these unknown genes and characteristics, further elucidating the mechanisms of extremophile survival and potentially informing the development of new biotechnologies for space exploration and other extreme environments.

Chelsi Cassilly↗