Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Status report on the Small Secure Transportable Autonomous Reactor (SSTAR) /Lead-cooled Fast Reactor (LFR) and supporting research and development.

This report provides an update on development of a pre-conceptual design for the Small Secure Transportable Autonomous Reactor (SSTAR) Lead-Cooled Fast Reactor (LFR) plant concept and supporting research and development activities. SSTAR is a small, 20 MWe (45 MWt), natural circulation, fast reactor plant for international deployment concept incorporating proliferation resistance for deployment in non-fuel cycle states and developing nations, fissile self-sufficiency for efficient utilization of uranium resources, autonomous load following making it suitable for small or immature grid applications, and a high degree of passive safety further supporting deployment in developing nations. In FY 2006, improvements have been made at ANL to the pre-conceptual design of both the reactor system and the energy converter which incorporates a supercritical carbon dioxide Brayton cycle providing higher plant efficiency (44 %) and improved economic competitiveness. The supercritical CO2 Brayton cycle technology is also applicable to Sodium-Cooled Fast Reactors providing the same benefits. One key accomplishment has been the development of a control strategy for automatic control of the supercritical CO2 Brayton cycle in principle enabling autonomous load following over the full power range between nominal and essentially zero power. Under autonomous load following operation, the reactor core power adjusts itself to equal the heat removal from the reactor system to the power converter through the large reactivity feedback of the fast spectrum core without the need for motion of control rods, while the automatic control of the power converter matches the heat removal from the reactor to the grid load. The report includes early calculations for an international benchmarking problem for a LBE-cooled, nitride-fueled fast reactor core organized by the IAEA as part of a Coordinated Research Project on Small Reactors without Onsite Refueling; the calculations use the same neutronics computer codes and methodologies applied to SSTAR. Another section of the report details the SSTAR safety design approach which is based upon defense-in-depth providing multiple levels of protection against the release of radioactive materials and how the inherent safety features of the lead coolant, nitride fuel, fast neutron spectrum core, pool vessel configuration, natural circulation, and containment meet or exceed the requirements for each level of protection. The report also includes recent results of a systematic analysis by LANL of data on corrosion of candidate cladding and structural material alloys of interest to SSTAR by LBE and Pb coolants; the data were taken from a new database on corrosion by liquid metal coolants created at LANL. The analysis methodology that considers penetration of an oxidation front into the alloy and dissolution of the trailing edge of the oxide into the coolant enables the long-term corrosion rate to be extracted from shorter-term corrosion data thereby enabling an evaluation of alloy performance over long core lifetimes (e.g., 30 years) that has heretofore not been possible. A number of candidate alloy specimens with special treatments or coatings which might enhance corrosion resistance at the temperatures at which SSTAR would operate were analyzed following testing in the DELTA loop at LANL including steels that were treated by laser peening at LLNL; laser peening is an approach that alters the oxide-metal bonds which could potentially improve corrosion resistance. LLNL is also carrying out Multi-Scale Modeling of the Fe-Cr system with the goal of assisting in the development of cladding and structural materials having greater resistance to irradiation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Software-Based Challenges of Developing the Future Distribution Grid

The software that the utility industry currently uses may be insufficient to analyze the distribution grid as it rapidly modernizes to include active resources such as distributed generation, switch and voltage control, automation, and increasingly complex loads. Although planners and operators have traditionally viewed the distribution grid as a passive load, utilities and consultants increasingly need enhanced analysis that incorporates active distribution grid loads in order to ensure grid reliability. Numerous commercial and open-source tools are available for analyzing distribution grid systems. These tools vary in complexity from providing basic load-flow and capacity analysis under steady-state conditions to time-series analysis and even geographical representations of dynamic and transient events. The need for each type of analysis is not well understood in the industry, nor are the reasons that distribution analysis requires different techniques and tools both from those now available and from those used for transmission analysis. In addition, there is limited understanding of basic capability of the tools and how they should be practically applied to the evolving distribution system. The study reviews the features and state of the art capability of current tools, including usability and visualization, basic analysis functionality, advanced analysis including inverters, and renewable generation and load modeling. We also discuss the need for each type of distribution grid system analysis. In addition to reviewing basic functionality current models, we discuss dynamics and transient simulation in detail and draw conclusions about existing software?s ability to address the needs of the future distribution grid as well as the barriers to modernization of the distribution grid that are posed by the current state of software and model development. Among our conclusions are that accuracy, data transfer, and data processing abilities are key to future distribution grid modeling, and measured data sources are a key missing element . Modeling tools need to be calibrated based on measured grid data to validate their output in varied conditions such as high renewables penetration and rapidly changing topology. In addition, establishing a standardized data modeling format would enable users to transfer data among tools to take advantage of different analysis features. ?

99 GENERAL AND MISCELLANEOUS↗

Bilevel Nodal Behind-the-meter Solar Disaggregation Under Unexpected Extreme Weather Conditions

As the power grid undergoes significant paradigm shift due to the increasing penetration of renewable generation, the ever-growing installation of behind-the-meter (BTM) solar generation in the power grid also has a significant impact on nodal loads, posing challenges on transmission operators. Furthermore, increasing frequent and severe extreme weather events intertwine with ubiquitous BTM solar generations and have amplified the challenges of accurately model nodal load profiles, especially under the lack of ground-truth information for verification. To tackle these challenges, this paper introduces a bilevel model that utilizes year-long data (e.g., proxy solar, zonal load, and individual node load profiles) to disaggregate metered profiles into actual demand and BTM solar generation at each transmission node. The proxy solar not only scales the BTM solar generation of individual nodes but also create a compensation term for enhancing performance on days with unexpected extreme weather events. The proposed algorithm is validated with real-world PJM Interconnection data during unexpected events like the recent Winter Storm Elliott. For quantitative evaluations, a novel Score error is introduced, which is based on mean percentages and load scales and offers a universal assessment method suitable for all nodes and different data formats (e.g., normalized or raw values).

behind-the-meter solar, load disaggregations, load↗

Functional Assessment of Shell Recharge Solutions' SKY™ Platform OpenADR Capability

The project’s overall objective is to research, develop, and conduct a wide-scale demonstration of a utility smart charge management (SCM) system to develop optimal managed charging structures for grid value, evaluate the impact of EV charging on local distribution utility operations, and evaluate the utilities’ ability to control electronic vehicle (EV) charging load based on grid conditions. This report covers Argonne’s validation testing in the first period of the project, the objective of which was to determine the current managed charging functionality of the EVSE hardware, the network and the vehicle telematics software solution and understand gaps that need to be addressed prior to a large-scale demonstration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Speed to Power: Solutions for Accelerating Large Load Connections

Rapid growth in demand from data centers and other large loads is creating a range of new challenges for electricity planners, investors, system operators, and regulators, leading to bottlenecks that have slowed connection of large loads to the electric grid. In response, innovative solutions for accelerating large load connections are beginning to emerge across the U.S. Drawing on an extensive document and literature review, this report identifies more than 40 potential solutions for accelerating large load connections, organized into five functional areas: load forecasting, interconnection, resource planning and procurement, markets and operations, and cost allocation and ratemaking. The five functional areas provide a framework for organizing challenges and solutions to large load connection bottlenecks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electromagnetic Transient Modeling of Data Centers

This report serves as a user manual for the accompanying EMT model library developed by the National Laboratory of the Rockies (NLR) for various equipment in large data centers. The EMT model library enables detailed modeling of large data center loads for conducting grid stability studies. The EMT model library for data centers include detailed models of a 5.5 kW power supply unit (PSU), a 2.5 uninterruptible power supply (UPS), a 260 MW gas turbine-generator, a 500 kW motor load, and a 33 kW IT rack. These components represent all major equipment in data centers that need to be modeled for performing grid stability studies for data centers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Status of development of the Small Secure Transportable Autonomous Reactor (SSTAR) for worldwide sustainable nuclear energy supply.

Significant progress and improvements have been made on development of a pre-conceptual design of the Secure Transportable Autonomous Reactor (SSTAR) Lead-Cooled Fast Reactor (LFR) concept since it was last reported on at ICAPP 05. SSTAR is a small, 20 MWe (45 MWt), exportable, natural circulation, fast reactor plant concept incorporating proliferation resistance for deployment in non-fuel cycle states and developing nations, fissile self-sufficiency for efficient utilization of uranium resources, autonomous load following making it suitable for small or immature grid applications, and a high degree of passive safety. Customers of SSTAR include: (1) clients looking for energy security at small capital outlay; (2) cities in developing nations; and (3) deregulated independent power producers in developed nations. The SSTAR pre-conceptual design integrates three major features: primary coolant natural circulation heat transport; lead (Pb) coolant; and transuranic nitride fuel in a pool vessel configuration. The Pb coolant flows upward through the core which is an open-lattice of large-diameter (2.5 centimeter) fuel pins containing transuranic nitride pellets clad bonded with liquid Pb to silicon-enhanced ferritic/martensitic (F/M) stainless steel arranged on a triangular pitch with spacing maintained by grid spacers; the core does not incorporate removable fuel assemblies as one means of restricting access to the fuel. The whole core is a single removable assembly with a long lifetime (30 years) at which time refueling equipment is brought onsite. Conversion of the core thermal energy to electricity is accomplished using a supercritical carbon dioxide (S-CO{sub 2}) Brayton cycle energy converter providing higher plant efficiencies and lower balance of plant costs than the traditional Rankine steam cycle operating at the same reactor core outlet temperature. A control strategy has been developed for automatic control of the S-CO{sub 2} Brayton cycle in principle enabling autonomous load following over the full power range between nominal and essentially zero power whereby the reactor core power adjusts itself to the heat removal from the reactor system to the power converter through the large reactivity feedback of the fast spectrum core without the need for motion of control rods, while the automatic control of the power converter matches the heat removal from the reactor to the grid load. A safety design approach has been formulated for SSTAR based upon defense-in-depth providing multiple levels of protection against the release of radioactive materials. The inherent safety features of the lead coolant (T{sub boil} = 1740 C, lack of chemical reaction of Pb with the CO{sub 2} working fluid, low absorption of neutrons by Pb, and the heavy Pb), nitride fuel (high thermal conductivity, transuranic nitride decomposition temperature {approx} 1300 C, compatibility with cladding, low volumetric swelling and fission gas release), fast neutron spectrum core, pool vessel configuration, natural circulation, and containment enable the requirements for each level of protection to be readily met or exceeded. The interest in higher plant efficiencies has heretofore driven interest in operation of SSTAR at higher Pb temperatures to take advantage of the increase in plant efficiency with temperature of the S-CO{sub 2} Brayton cycle. A peak cladding temperature of 650 C has been used as a goal; at this temperature, a reactor core outlet temperature of 564 C is achieved resulting in a Brayton cycle efficiency of 44.2 % and a net plant efficiency of 43.8 %. It has always been recognized that this would require the development of cladding and structural materials for long-term service in Pb coolant up to 650 C peak cladding temperature with corrosion protection provided by active maintenance and control of the dissolved oxygen potential in the coolant giving rise to the formation of protective oxide layers on the steel cladding and structures. SSTAR development has been supported by the testing in the DELTA loop at Los Alamos National Laboratory of alloy specimens with special treatments or coatings which might enhance corrosion resistance at the temperatures at which SSTAR operates. The focus of LFR development in the U.S. is now shifting towards the development of a near-term deployable LFR test demonstrator and a near-term deployable small exportable LFR. Both reactors would operate at lower temperatures enabling the use of existing materials such as T91 or HT9 F/M stainless steel that is already incorporated into the ASME codes and have been shown to have corrosion resistance to lead-bismuth eutectic with active oxygen control at temperatures below about 550 C in experiments carried out in the DELTA loop and elsewhere.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mining Smart Meter Data to Enhance Distribution Grid Observability for Behind-the-Meter Load Control: Significantly improving system situational awareness and providing valuable insights

Distributed Energy Resources (DERs) are playing an increasingly important role in power systems. In 2023, five categories of DERs-distributed solar, electric vehicles (EVs), energy storage, residential smart thermostats, and small-scale combined heat and power-are expected to contribute about 104 GW to the U.S. summer peak (see GTM, 2018). With the increasing integration of DERs in power distribution systems, distributed load control is imperative to smooth the fluctuations that they introduce. However, a main challenge is that distribution systems lack systematic situational awareness because of their limited sensors. Furthermore, most customer-level behind-the-meter (BTM) DERs, such as rooftop photovoltaics (PVs), are being integrated into distribution systems, which complicates the system monitoring and control. Furthermore, enhanced electric grid monitoring is needed to promote renewable integration while ensuring reliability, but current approaches rely on expensive sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of electric vehicles on the IEEE 34 node distribution infrastructure

With the growing penetration of the electric vehicles to our daily life owing to their economic and environmental benefits, there will be both opportunities and challenges to the utilities when adopting plug-in electric vehicles (PEV) to the distribution network. In this study, a thorough analysis based on real-world project is conducted to evaluate the impacts of electric vehicles infrastructure on the grid relating to system load flow, load factor, and voltage stability. IEEE 34 node test feeder was selected and tested along with different case scenarios utilizing the electrical distribution design (EDD) software to find out the potential impacts to the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Load-Side Control for Frequency Regulation in Smart Grids

Frequency control rebalances supply and demand while maintaining the network state within operational margins. It is implemented using fast ramping reserves that are expensive and wasteful, and which are expected to become increasingly necessary with the current acceleration of renewable penetration. The most promising solution to this problem is the use of demand response, i.e., load participation in frequency control. Yet it is still unclear how to efficiently integrate load participation without introducing instabilities and violating operational constraints. In this paper, we present a comprehensive load-side frequency control mechanism that can maintain the grid within operational constraints. In particular, our controllers can rebalance supply and demand after disturbances, restore the frequency to its nominal value, and preserve interarea power flows. Furthermore, our controllers are distributed (unlike the currently implemented frequency control), can allocate load updates optimally, and can maintain line flows within thermal limits. We prove that such a distributed load-side control is globally asymptotically stable and robust to unknown load parameters. We illustrate its effectiveness through simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Scalable Hardware-and-Human-in-the-Loop Grid-interactive Efficient Building Equipment Performance Dataset

This project developed a publicly available, high-fidelity dataset about the interactions among humans, homes, and heat pumps supporting grid interactive efficient buildings to balance demand on the grid with comfort for occupants. Laboratory measurements and simulations of the hardware capture the second-scale electric power dynamics of heat pumps providing grid services like load shifting and load shedding. Field measurements, behavior tracking, and qualitative surveys of people in their homes over multiple years—including experimentally adjusting the heating and cooling system to provide grid services—to capture the reciprocal effect of human behavior on grid services, and grid services on human comfort. Taken together, these data capture the complete Hardware and Human in the loop system for residential heat pumps, reducing large uncertainties in simulation for design, and models for control of heat pumps, and grid-interactive buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

COHORT: Coordination of Heterogeneous Thermostatically Controlled Loads for Demand Flexibility

Demand flexibility is increasingly important for power grids. Careful coordination of thermostatically controlled loads (TCLs) can modulate energy demand, decrease operating costs, and increase grid resiliency. We propose a novel distributed control framework for the Coordination Of HeterOgeneous Residential Thermostatically controlled loads (COHORT). COHORT is a practical, scalable, and versatile solution that coordinates a population of TCLs to jointly optimize a grid-level objective, while satisfying each TCL’s end-use requirements and operational constraints. To achieve that, we decompose the grid-scale problem into subproblems and coordi- nate their solutions to find the global optimum using the alternating direction method of multipliers (ADMM). The TCLs’ local problems are distributed to and computed in parallel at each TCL, making COHORT highly scalable and privacy-preserving. While each TCL poses combinatorial and non-convex constraints, we characterize these constraints as a convex set through relaxation, thereby making COHORT computationally viable over long planning horizons. After coordination, each TCL is responsible for its own control and tracks the agreed-upon power trajectory with its preferred strategy. In this work, we translate continuous power back to discrete on/off actuation, using pulse width modulation. COHORT is generalizable to a wide range of grid objectives, which we demonstrate through three distinct use cases: generation following, minimizing ramping, and peak load curtailment. In a notable experiment, we validated our approach through a hardware-in-the-loop simulation, including a real-world air conditioner (AC) controlled via a smart thermostat, and simulated instances of ACs modeled after real-world data traces. During the 15-day experimental period, COHORT reduced daily peak loads by an average of 12.5% and maintained comfortable temperatures.

demand response↗

EV charging site day-ahead load prediction in a synthetic environment for RL based grid-informed charging

Ensuring grid health in the face of increasing demand for power is an emerging challenge especially due to transportation electrification. A free market approach to influencing electric vehicle (EV) load through grid-informed hourly dynamic pricing is introduced in this work. The setting of charging price is done by a reinforcement learning (RL) agent that learns the complicated dynamics by interacting with a synthetic environment. This synthetic environment is a combination of distribution feeder simulation, EV charger user behavior dynamics, and EV charging simulation. A key module in this synthetic environment involves obtaining the day-ahead charging profile of EV charging stations based on real-world past data. The day-ahead prediction is also useful in other traditional optimizations related to EV charge scheduling. The proposed approach involves using EV charging data from two different past time horizons – one to determine the shape of the daily profile and the other to determine a scaling value to capture actual energy consumption. Real-world charging data over many years from the ACN charging network has been used to demonstrate the ability to predict the day-ahead profile with only charge session data. Both Python and MATLAB have been used for data cleaning, processing, analysis, and prediction.

Suryanarayana, Harish↗

Heat Storage Options for Sodium, Salt and Helium Cooled Reactors to Enable Variable Electricity to the Grid and Heat to Industry with Base-Load Reactor Operations

Electricity markets are changing rapidly because of (1) the addition of wind and solar and (2) the goal of a low-carbon electricity grid. These changes result in times of high electricity prices and very low or negative electricity prices. California has seen its first month where more than 20% of the time (mid-day) the wholesale price of electricity was zero or negative. This creates large incentives for coupling heat storage to advanced reactors to enable variable electricity and industrial-heat output (to maximize revenue) while the reactor operates at base load (minimize cost). Recent studies have examined coupling various types of heat storage to Rankine and Brayton power cycles. However, there has been little examination of heat-storage options between (1) the reactor and (2) the power-conversion system or industrial customer. Heat-storage systems can be incorporated into sodium , helium-, and salt-cooled reactors. Salt-cooled reactors include the fluoride-salt-cooled high-temperature reactor (FHR) with its solid fuel and clean coolant and the molten salt reactor (MSR) with its fuel dissolved in the salt. For sodium and salt reactors, it is assumed that a heat-storage system would be in the secondary loop between the reactor and power cycle. For helium-cooled reactors, heat storage can be in the primary or secondary loop. This report is a first look at the rational and the heat storage options for deploying gigawatt-watt hour heat-storage systems with GenIV reactors. Economics and safety are the primary selection criteria. The leading heat-storage candidate for sodium-cooled systems (a low-pressure secondary system with small temperature drop across the reactor core) is sodium coolant stored in large steel tanks, with the coolant transferring heat in channels. The design minimizes sodium volume in the storage and, thus, the risks and costs associated with sodium. For helium systems (high-pressure with large temperature drop across the core), the leading heat storage options are (1) varying the temperature of the reactor core, (2) steel or alumina firebrick in a secondary pressure vessel and (3) nitrate or hot-rock/firebrick at atmospheric pressure. For salt systems (low pressure, high temperatures, and small temperature drop across the reactor core) the leading heat-storage systems are secondary salts. In each case, options are identified and questions to be addressed are identified. In some cases there is a strong coupling between the heat-storage technology and the power cycle. The leading sodium heat-storage technology may imply changes in the power cycle. High-temperature salt systems couple efficiency to Brayton power cycles that may create large incentives for the heat storage to remain within the power cycle rather than in any intermediate heat transfer loop.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Intelligent load pattern modeling and denoising using improved variational mode decomposition for various calendar periods

This paper proposes a novel approach to identify the load patterns considering calendar impact and denoising process, which advances the state of art of load identification and load forecasting to a more flexible and adaptive extent by revealing the correlation between load profile and the substantial influence factors. With the rapid development and the promising application of energy intemet and grid modernization, the accurate load modeling and forecasting especially by load pattern modeling (LPM) have become more and more critical to observe and estimate load profile so as to optimize the operation efficiency of the power grid. Traditional methods mostly focus on the static LPM itself which are unable to account the non-linear and highly dynamic load fluctuations in order to balance the demand of the power grid during various calendar period (VCP) scheduling. In this paper, a load pattern modeling method for power grid considering the impact of typical calendar effects is proposed using a combination of improved variational mode decomposition (IVMD) and deep belief network (DBN) algorithm. Firstly, an index of load curve curvature (LCC) is proposed to improve the selection of value K in the conventional VMD algorithm. The value K of the intrinsic modality is determined by adopting LCC to better quantify the average instantaneous frequency of the modal decomposition of the VMD and to reduce the elevated stochasticity of k. Secondly, an optimization formulation is developed based on adaptive segmented loop decomposition of the typical correlation coefficient to suppress the edge effect in VMD decomposition, which would enable the reconstructed curve to incorporate the variabilities from the initial data. Finally, the IVMD and DBN algorithms are jointly implemented to optimize the accuracy of VCP load pattern modeling curve regression. Numerical examples have been performed with the results proving that the proposed method significantly outperforms the state-of-art in reducing the modeling error of VCP load curve, improving the overall forecasting accuracy, and reducing load dispatching cost.

deep belief network↗

Load Reduction, Demand Response and Energy Efficient Technologies and Strategies

The Department of Energy’s (DOE’s) Pacific Northwest National Laboratory (PNNL) was tasked by the DOE Office of Electricity (OE) to recommend load reduction and grid integration strategies, and identify additional demand response (energy efficiency/conservation opportunities) and strategies at the Forest City Housing (FCH) redevelopment at Pearl Harbor and the Marine Corps Base Hawaii (MCBH) at Kaneohe Bay. The goal was to provide FCH staff a path forward to manage their electricity load and thus reduce costs at these FCH family housing developments. The initial focus of the work was at the MCBH given the MCBH has a demand-ratchet tariff, relatively high demand (~18 MW) and a commensurate high blended electricity rate (26 cents/kWh). The peak demand for MCBH occurs in July-August. And, on average, family housing at MCBH contributes ~36% to the MCBH total energy consumption. Thus, a significant load reduction in family housing can have a considerable impact on the overall site load. Based on a site visit to the MCBH and meetings with MCBH installation, FCH, and Hawaiian Electric Company (HECO) staff, recommended actions (including a "smart grid" recommendation) that can be undertaken by FCH to manage and reduce peak-demand in family housing are made. Recommendations are also made to reduce overall energy consumption, and thus reduce demand in FCH family housing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Framework to Evaluate the Grid Impacts of EV Fleet Charging Solutions

Growing Electric vehicle (EV) adoption in residential and commercial applications is driving the need for the charging infrastructures required to fulfill the charging needs. The resulting increase in demand for electric power will add a significant load to the electric grid, which could negatively impact the grid operation. EVs are power electronic loads and draw harmonic currents which can lead to a host of power quality issues. Therefore, it is crucial to assess the grid impacts and management of EV charging loads to ensure the reliable operation of the electric grid. In this paper, we develop a framework to help determine power-quality impacts given an EV charging schedule on the system. We compare the performance of unmanaged and managed charging solutions on factors like voltage drop, flicker, harmonic distortion and the peak site load - based on the EV depot in Hazelwood school district. The results allow insights into operation and site design of EV depots.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Advanced Techniques for Power System Identification from Measured Data

Time-synchronized measurements provide rich information for estimating a power-system's electromechanical modal properties via advanced signal processing. This information is becoming critical for the improved operational reliability of interconnected grids. A given mode's properties are described by its frequency, damping, and shape. Modal frequencies and damping are useful indicators of power-system stress, usually declining with increased load or reduced grid capacity. Mode shape provides critical information for operational control actions. This project investigated many advanced techniques for power system identification from measured data focusing on mode frequency and damping ratio estimation. Investigators from the three universities coordinated their effort with Pacific Northwest National Laboratory (PNNL). Significant progress was made on developing appropriate techniques for system identification with confidence intervals and testing those techniques on field measured data and through simulation. Experimental data from the western area power system was provided by PNNL and Bonneville Power Administration (BPA) for both ambient conditions and for signal injection tests. Three large-scale tests were conducted for the western area in 2005 and 2006. Measured field PMU (Phasor Measurement Unit) data was provided to the three universities. A 19-machine simulation model was enhanced for testing the system identification algorithms. Extensive simulations were run with this model to test the performance of the algorithms. University of Wyoming researchers participated in four primary activities: (1) Block and adaptive processing techniques for mode estimation from ambient signals and probing signals, (2) confidence interval estimation, (3) probing signal design and injection method analysis, and (4) performance assessment and validation from simulated and field measured data. Subspace based methods have been use to improve previous results from block processing techniques. Bootstrap techniques have been developed to estimate confidence intervals for the electromechanical modes from field measured data. Results were obtained using injected signal data provided by BPA. A new probing signal was designed that puts more strength into the signal for a given maximum peak to peak swing. Further simulations were conducted on a model based on measured data and with the modifications of the 19-machine simulation model. Montana Tech researchers participated in two primary activities: (1) continued development of the 19-machine simulation test system to include a DC line; and (2) extensive simulation analysis of the various system identification algorithms and bootstrap techniques using the 19 machine model. Researchers at the University of Alaska-Fairbanks focused on the development and testing of adaptive filter algorithms for mode estimation using data generated from simulation models and on data provided in collaboration with BPA and PNNL. There efforts consist of pre-processing field data, testing and refining adaptive filter techniques (specifically the Least Mean Squares (LMS), the Adaptive Step-size LMS (ASLMS), and Error Tracking (ET) algorithms). They also improved convergence of the adaptive algorithms by using an initial estimate from block processing AR method to initialize the weight vector for LMS. Extensive testing was performed on simulated data from the 19 machine model. This project was also extensively involved in the WECC (Western Electricity Coordinating Council) system wide tests carried out in 2005 and 2006. These tests involved injecting known probing signals into the western power grid. One of the primary goals of these tests was the reliable estimation of electromechanical mode properties from measured PMU data. Applied to the system were three types of probing inputs: (1) activation of the Chief Joseph Dynamic Brake, (2) mid-level probing at the Pacific DC Intertie (PDCI), and (3) low-level probing on the PDCI. The Chief Joseph Dynamic Brake is a 1400 MW disturbance to the system and is injected for a half of a second. For the mid and low-level probing, the Celilo terminal of the PDCI is modulated with a known probing signal. Similar but less extensive tests were conducted in June of 2000. The low-level probing signals were designed at the University of Wyoming. A number of important design factors are considered. The designed low-level probing signal used in the tests is a multi-sine signal. Its frequency content is focused in the range of the inter-area electromechanical modes. The most frequently used of these low-level multi-sine signals had a period of over two minutes, a root-mean-square (rms) value of 14 MW, and a peak magnitude of 20 MW. Up to 15 cycles of this probing signal were injected into the system resulting in a processing gain of 15. The resulting measured response at points throughout the system was not much larger than the ambient noise present in the measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗