Search NASA⌕ Search

SEARCH · Search NASA

Results for “HIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

300 records · Page 17

Materials Characterization of Additively Manufactured Components for Rocket Propulsion

To advance Additive Manufacturing (AM) technologies for production of rocket propulsion components the NASA Glenn Research Center (GRC) is applying state of the art characterization techniques to interrogate microstructure and mechanical properties of AM materials and components at various steps in their processing. The materials being investigated for upper stage rocket engines include titanium, copper, and nickel alloys. Additive manufacturing processes include laser powder bed, electron beam powder bed, and electron beam wire fed processes. Various post build thermal treatments, including Hot Isostatic Pressure (HIP), have been studied to understand their influence on microstructure, mechanical properties, and build density. Micro-computed tomography, electron microscopy, and mechanical testing in relevant temperature environments has been performed to develop relationships between build quality, microstructure, and mechanical performance at temperature. A summary of GRC's Additive Manufacturing roles and experimental findings will be presented.

Additive Manufacturing↗

Femoral Head Bone Loss Following Short and Long-Duration Spaceflight

Exposure to mechanical unloading during spaceflight is known to have significant effects on the musculoskeletal system. Our ongoing studies with the mouse bone model have identified the failure of normal stem cell-based tissue regeneration, in addition to tissue degeneration, as a significant concern for long-duration spaceflight, especially in the mesenchymal and hematopoietic tissue lineages. The 30-day BionM1 and the 37-day Rodent Research 1 (RR1) missions enabled the possibility of studying these effects in long-duration microgravity experiments. We hypothesized that the inhibition of stem cell-based tissue regeneration in short-duration spaceflight would continue during long-duration spaceflight and furthermore would result in significant tissue alterations. MicroCT analysis of BionM1 femurs revealed 31 decrease in bone volume ratio, a 14 decrease in trabecular thickness, and a 20 decrease in trabecular number in the femoral head of space-flown mice. Furthermore, high-resolution MicroCT and immunohistochemical analysis of spaceflight tissues revealed a severe disruption of the epiphyseal boundary, resulting in endochondral ossification of the femoral head and perforation of articular cartilage by bone. This suggests that spaceflight in microgravity may cause rapid induction of an aging-like phenotype with signs of osteoarthritic disease in the hip joint. However, mice from RR1 exhibited significant bone loss in the femoral head but did not exhibit the severe aging and disease-like phenotype observed during BionM1. This may be due to increased physical activity in the RH hardware. Immunohistochemical analysis of the epiphyseal plate and investigation of cellular proliferation and differentiation pathways within the marrow compartment and whole bone tissue is currently being conducted to determine alterations in stem cell-based tissue regeneration between these experiments. Our results show that the observed inhibition of stem cell-based tissue regeneration persists during long-duration spaceflight. Furthermore, spaceflight femurs from BionM1 indicate onset of an accelerated aging-like phenotype with signs of osteoarthritic disease shown by disruption of the epiphyseal boundary and endochondral ossification. These effects are likely caused by a failure of stem cells to regenerate degraded tissues and may have significant implications for bone and cartilage health following extensive periods of mechanical unloading during long-duration spaceflight.

stem cells↗

Femoral Head Bone Loss Following Short and Long-Duration Spaceflight

Exposure to mechanical unloading during spaceflight is known to have significant effects on the musculoskeletal system. Our ongoing studies with the mouse bone model have identified the failure of normal stem cell-based tissue regeneration, in addition to tissue degeneration, as a significant concern for long-duration spaceflight, especially in the mesenchymal and hematopoietic tissue lineages. The 30-day BionM1 and the 37-day Rodent Research 1 (RR1) missions enabled the possibility of studying these effects in long-duration microgravity experiments. We hypothesized that the inhibition of stem cell-based tissue regeneration in short-duration spaceflight would continue during long-duration spaceflight and furthermore would result in significant tissue alterations. MicroCT analysis of BionM1 femurs revealed 31% decrease in bone volume ratio, a 14% decrease in trabecular thickness, and a 20% decrease in trabecular number in the femoral head of space-flown mice. Furthermore, high-resolution MicroCT and immunohistochemical analysis of spaceflight tissues revealed a severe disruption of the epiphyseal boundary, resulting in endochondral ossification of the femoral head and perforation of articular cartilage by bone. This suggests that spaceflight in microgravity may cause rapid induction of an aging-like phenotype with signs of osteoarthritic disease in the hip joint. However, mice from RR1 exhibited significant bone loss in the femoral head but did not exhibit the severe aging and disease-like phenotype observed during BionM1.This may be due to increased physical activity in the RH hardware. Immunohistochemical analysis of the epiphyseal plate and investigation of cellular proliferation and differentiation pathways within the marrow compartment and whole bone tissue is currently being conducted to determine alterations in stem cell-based tissue regeneration between these experiments. Our results show that the observed inhibition of stem cell-based tissue regeneration persists during long-duration spaceflight. Furthermore, spaceflight femurs from BionM1 indicate onset of an accelerated aging-like phenotype with signs of osteoarthritic disease shown by disruption of the epiphyseal boundary and endochondral ossification. These effects are likely caused by a failure of stem cells to regenerate degraded tissues and may have significant implications for bone and cartilage health following extensive periods of mechanical unloading during long-duration spaceflight.

microgravity↗

Risk Of Early Onset Osteoporosis Due To Spaceflight

Bone minerals decline in microgravity, and bone mineral density (BMD) losses of approximately -1 to -1.5% per month were calculated for astronauts serving on long-duration missions prior to 2009. It is unclear whether BMD losses will stabilize with time in space, or continue to diminish with time. In addition, it is unknown if fractional gravity, present on the moon and Mars, will mitigate the mineral loss. Clinicians diagnose osteoporosis in premenopausal females and males younger than 50 years on the basis of BMD T-scores < -2.5 (hip and lumbar spine) accompanied by clinical evidence of a fragility fracture. If mission-related changes to the skeleton cannot be corrected by rehabilitation after the mission, crewmembers could be at risk for premature osteoporosis-related fractures in later life. To mitigate this risk it is necessary to understand the dynamics underlying the BMD changes that occur in microgravity, to monitor for the persistence of changes after space flight, and to evaluate if and how current and future osteoporosis treatments might be used to mitigate the risk of long-term skeletal problems in astronauts.

Sibonga, Jean↗

Failure Simulation Testing of the Z-1 Spacesuit Titanium Bearing Assemblies

The Z-2 is a candidate for NASA's next generation spacesuit, designed for a range of possible missions with enhanced mobility for spacewalks both on planetary surfaces and in microgravity. Increased mobility was accomplished through innovations in shoulder and hip joints, using a number of new bearings to allow spacesuit wearers to dip, walk, and bend with ease; all important tasks for a planetary explorer collecting samples or traveling over rough terrain. The Advanced Spacesuit Development Team of NASA Johnson Space Center requested that the NASA White Sands Test Facility (WSTF) perform a series failure simulation tests on three titanium bearing assemblies, an elemental part of the joint construction used in new spacesuit designs. This testing simulated two undetected failures within the bearings and as a result the objective of this test program was to evaluate whether a failed or failing bearing could result in ignition of the titanium race material due to friction. The first failure was an inner seal leak sufficient to pressurize the race with +99 percent oxygen. The second failure was an improperly installed or mismatched ball port that created a protrusion in the ball bearing race, partially obstructing the nominal rolling path of each ball bearing. When the spacesuit bearings are assembled, bearing balls are loaded into the assembly via a ball port. The ball port is specific and unique to each bearing assembly (matched pair). The simulated mismatched ball port is a significant source of friction, which would be caused by an assembly error. To evaluate this risk, the bearings were cycled in a simulated worst-case scenario environment, with operational loads, and potential flaw conditions. During test the amount of actuation torque required and heat generated through continuous operation were measured and the bearings were observed for sparks or burning events. This paper provides detailed descriptions of the test hardware, methodology, and results.

de Baca, Richard C.↗

A 3D-printed Broadband Millimeter Wave Absorber

We present the design, manufacturing technique, and characterization of a 3D-printed broadband graded index millimeter wave absorber. The absorber is additively manufactured using a fused filament fabrication (FFF) 3D printer out of a carbon-loaded high impact polystyrene (HIPS) filament and is designed using a space-filling curve to optimize manufacturability using said process. The absorber's reflectivity is measured from 63 GHz to 115 GHz and from 150 GHz to 215 GHz and is compared to electromagnetic simulations. The intended application is for terminating stray light in Cosmic Microwave Background (CMB) telescopes, and the absorber has been shown to survive cryogenic thermal cycling.

Matthew Petroff↗

NASA Advanced Space Suit xEMU Development Report – Components

For the past several years, the Exploration Extra-Vehicular Mobility Unit (xEMU) team at NASA’s Johnson Space Center has focused on the development and detailed design of the xEMU to support missions to the International Space Station (ISS) and a moon landing in 2024. In that context, this paper examines the development and baseline detailed design of the xEMU helmet, extra-vehicular visor assembly (EVVA), hard upper torso (HUT), shoulders, liquid cooling and ventilation garment (LCVG), boots, waist brief hip (WBH), ancillary hardware, and environmental protection garment (EPG) . This paper will outline the challenging technical requirements, significant architectural trades, technical solutions required to overcome these challenges, and a current status of the detailed design. The preliminary results of Design Verification Testing (DVT) as it relates specifically to these components will also be provided, along with a forward strategy for final maturation into a flight-ready design.

Shane McFarland↗

International Standard Measures During the AGBRESA Bed Rest Study

The Artificial Gravity Bed Rest with European Space Agency (AGBRESA) study involved 2 campaigns of 60-day bed rest at 6° head down tilt in the:envihab facility in Cologne, Germany, in 2019. The objective was to determine whether centrifugation of supine subjects mitigates physiological changes that occur due to the exposure to the spaceflight analog of 6° head down tilt. A set of international standard measures was used to evaluate bone, muscle, nutritional status, ocular changes, and psychological state and to assess cardiovascular, sensorimotor, and immune systems functions. After 60 days of bed rest, the subjects who were not exposed to centrifugation had significant decreases in mineral density at the hip and lumbar spine, decreased muscle strength of the knee and ankle, reduced maximal aerobic capacity, orthostatic intolerance, and impaired balance and locomotion, as well as significant biochemical, immunological, and psychological alterations. A daily 30-min exposure to 1 Gz supine centrifugation at the center of mass (0.3 Gz at the head, 2 Gz at the feet) mitigated mineral density loss in the femur neck and lumbar spine; and lessened the effects of bed rest on aerobic capacity, biochemistry, and immunology. However, low statistical power could contribute to the non-significant effects that are reported.

Bed rest↗

Comparative Study of Additively Manufactured Inconel 625 In the As-Built and Heat-Treated Condition

This study was conducted to characterize the microstructure and mechanical properties of Inconel 625 manufactured with laser powder bed fusion (L-PBF), electron beam melting (EBM), wire arc additive manufacturing (WAAM), electron beam directed energy deposition (EB-DED), laser powder directed energy deposition (LP-DED), and laser wire directed energy deposition (LW-DED) in both the as built and heat-treated condition. The heat treatment in this study included stress relieving, hot isostatic pressure (HIP), and solution treatment. The effects of the heat treatment on the grain widths and hardness of the alloy will be observed across the technologies before and after heat-treatment. At the end of this study there will be a comparative analysis of the alloy Inconel 625 across the six technologies.

V Luna↗

Analysis of Additively Manufactured Inconel 718 Combustion Behavior in Promoted Oxygen Environments

Promoted combustion testing is a vital tool for engineers to establish the combustion and flammability characteristics of materials (metallic or otherwise) in oxygen enriched environments. Historically, much of the established data for metallic promoted combustion has been with regards to cast and wrought forms. However, with the emergence of additive manufacturing as a preferred method of fabrication, the need exists to evaluate how metals in that form behave. This paper will serve as a review of the work that has been done and an analysis of the nickel-based superalloy Inconel 718, a material popular for aerospace applications such as liquid fueled rocket components and turbine engines. Promoted combustion testing (per the ASTM G124 standard) was conducted on samples of both wrought and selective laser melted fabrication, to provide comparison of flammability response between materials produced by each manufacturing method. Additionally, post-build treatments were applied to test samples to identify any effects on performance provided by hot isostatic pressing, oxygen-getting wrap during HIP, stress relieving, and solutionizing/aging heat treatments. This study will utilize optical and scanning electron microscopy, energy dispersive spectroscopy, x-ray diffraction, and metallography to identify the differences in behavior of additively manufactured and wrought Inconel 718.

Additively Manufactured↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S. Faragalla↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S Faragalla↗