Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat Generation Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Evaluation of mitigation strategies for radioactive fission gases in fluoride-salt-cooled high-temperature reactors

Here, the Fluoride-salt-cooled High-temperature Reactor (FHR) is a promising Generation IV nuclear reactor due to its improved safety design, near atmospheric working pressure, and high electric power conversion efficiency. However, control of radioactive fission gases, such as tritium, is a critical issue in FHRs due to the significantly larger production rate and potentially larger leakage rate of tritium compared to those in Light Water Reactors (LWRs). Therefore, this study proposes two mitigation strategies for tritium in FHRs: Double-Wall Heat eXchanger with a Tritium Carrier (DWHX-TC) option and Single-Wall Heat eXchanger with a Tritium Barrier (SWHX-TB) option. For the DWHX-TC option, two tube surface configurations, i.e., plain and fluted tubes, and four tritium carriers, i.e., helium, FLiBe, FLiNaK, and KF-ZrF 4 , are initially considered, among which the best tube configuration and promising tritium carrier are then selected and used for design optimization of the DWHX. For the SWHX-TB option, two cases, tritium barriers with and without cracks, are investigated in this study. In addition, the two mitigation strategies are evaluated by an in-house, one-dimensional, coupled HEat and MAss Transfer (HEMAT) code developed to predict the leakage rate of tritium in nuclear systems. Our analysis shows that (1) a double-wall configuration using fluted tubes as both the inner and outer tubes is better than other double-wall configurations investigated; (2) helium, as a tritium carrier, is superior to other candidates, including FLiBe, FLiNaK, and KF-ZrF 4 ; (3) the leakage rate of tritium (into the atmosphere) is reduced from 3400 Ci/day, taking the Advanced High-Temperature Reactor (AHTR) as a reference, to 4.0 Ci/day for an optimum design of the DWHX-TC option using helium as the tritium carrier and 1.7 Ci/day for an optimum design of the SWHX-TB option using 30-µm thick silicon carbide (SiC) as the tritium barrier (no cracks); and (4) potential cracks in tritium barriers may significantly deteriorate mass transfer performance of the SWHX-TB option. For example, a cracking rate of 0.1% leads to an increase of 694.1% in the leakage rate under the conditions investigated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cascaded hard X-ray self-seeded free-electron laser at megahertz repetition rate

High-resolution X-ray spectroscopy in the sub-nanosecond to femtosecond time range requires ultrashort X-ray pulses and a spectral X-ray flux considerably larger than that presently available. X-ray free-electron laser (XFEL) radiation from hard X-ray self-seeding (HXRSS) setups has been demonstrated in the past and offers the necessary peak flux properties. So far, these systems could not provide high repetition rates enabling a high average flux. We report the results for a cascaded HXRSS system installed at the European XFEL, currently the only operating high-repetition-rate hard X-ray XFEL facility worldwide. A high repetition rate, combined with HXRSS, allows the generation of millijoule-level pulses in the photon energy range of 6–14 keV with a bandwidth of around 1 eV (corresponding to about 1 mJ eV –1 peak spectral density) at the rate of ten trains per second, each train including hundreds of pulses arriving at a megahertz repetition rate. At 2.25 MHz repetition rate and photon energies in the 6–7 keV range, we observed and characterized the heat-load effects on the HXRSS crystals, substantially altering the spectra of subsequent X-ray pulses. We demonstrated that our cascaded self-seeding scheme reduces this detrimental effect to below the detection level. This opens up exciting new possibilities in a wide range of scientific fields employing ultrafast X-ray spectroscopy, scattering and imaging techniques.

47 OTHER INSTRUMENTATION↗

Towards linking lab and field lifetimes of perovskite solar cells

Metal halide perovskite solar cells (PSCs) represent a promising low-cost, thin-film photovoltaic (PV) technology, with unprecedented power conversion efficiencies (PCEs) obtained for both single-junction and tandem applications. To push PSCs toward commercialization, it is critical, albeit challenging, to understand device reliability under real-world outdoor conditions where multiple stress factors (e.g., light, heat, humidity) coexist, generating complicated degradation behaviors. It is necessary to identify accelerated indoor testing protocols - which can correlate specific stressors with observed degradation modes in fielded devices - to quickly guide PSC development. Here, we use a state-of-the-art p-i-n PSC stack (with PCE up to ~25.5%) to show that indoor accelerated stability tests can predict our 6-month outdoor aging tests. Device degradation rates under illumination and at elevated temperatures are most instructive for understanding outdoor device reliability. Further, we also find that the indium tin oxide (ITO)/self-assembled monolayer (SAM)-based hole transport layer (HTL)/perovskite interface most strongly affects our device operation stability. Improving the ion-blocking properties of the SAM HTL increases averaged device operational stability at 50 degree C-85 °C by a factor of ~2.8, reaching over 1000 h at 85 °C and to near 8200 h at 50 °C with a projected 20% degradation, which is among the best to date for high-efficiency p-i-n PSCs.

14 SOLAR ENERGY↗

Decarbonizing Cooking Appliances With Hydrogen

A novel hydrogen compatible heterogeneous burner prototype was engineered, fabricated, and evaluated for applications in cooking appliances. The key features targeted and accomplished under this effort included fuel flexibility, tolerance to high hydrogen concentrations (up to 85% in atmospheric design and 100% in premixed design), wide range of thermal power ratings, thermal cycling, reliability, and most importantly safety. The burner was operated in the range of 3000 – 12,000 Btu/h under all practical operating conditions (cold start, hot restart, fuel concentration variance). The heterogeneous oxidation burner technology was evaluated for overall performance targeting safety, reliability, emissions, fuel flexibility, and energy efficiency in a commercial RV and residential cooking range appliance prototypes. The burner demonstrated safe and reliable performance generating infrared heating energy without the consumption of any parasitic energy while using low-cost materials. Performance evaluation testing of the novel IR burner demonstrated fuel flexibility with hydrogen blended natural gas while significantly eliminating air pollutants like NOx and methane and increasing the energy efficiency by up to 20%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Modeling shock-induced void collapse in single-crystal Ta systems at the mesoscales

Understanding the role of microstructural heterogeneities on the shock wave propagation and defect evolution behavior is essential to predicting the dynamic response of metals. Heterogeneities, such as voids, provide challenges to understanding the wave propagation behavior as the shock-void interaction can collapse the void and result in large plastic strains and significant heating (hot spot formation) in the metal. Accurate modeling of this phenomenon requires predicting the void collapse mechanisms and the related heat generation and dissipation mechanisms (hotspot formation) that determine the microstructure evolution. While molecular dynamics (MD) simulations can model the void collapse behavior, the time/length scale capabilities pose a challenge to connect with continuum models or the experimental scales. Here, this study presents the capability of the newly developed quasi-coarse-grained dynamics (QCGD) method that extends the MD simulations to larger system sizes and longer times to model this phenomenon. This study uses QCGD simulations to investigate the mechanisms of shock wave interactions with pre-existing voids in single-crystal Ta microstructures for variations in shock pressures, void size, and loading orientations. For a given orientation, the plasticity contributions and rates of void collapse are observed to vary with shock pressures and void size. The larger void sizes and higher pressures result in increased temperatures (hot spots) and faster void collapse rates and unravel the variations in the plasticity contributions. In addition, QCGD simulations investigate the post-collapse microstructure evolution as a release wave travels through the hot spot region. The simulations reveal that the reduction in temperatures due to heat dissipation initiates the dynamic recrystallization behavior in the hotspot regions.

36 MATERIALS SCIENCE↗

Status of EM Pump Modeling Capability for VTR

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. Most recently, SAS4A/SASSYS-1 has been selected as the safety analysis software for the Versatile Test Reactor (VTR), a new materials testing Sodium Fast Reactor (SFR) to be built by the Department of Energy. In order to support analysis of the VTR, which will utilize ElectroMagnetic (EM) pumps as the primary coolant pumps, the development of new EM pump modeling capabilities has been initiated for SAS4/SASSYS-1. The new physics-based EM pump model captures systems-level transient performance based on equivalent circuit theory and is highly flexible to model a wide range of electromagnetic pumps of the three-phase linear induction type subject to changes in power supply and plant conditions. Within the equivalent circuit framework, two sub-models are developed to provide options for analysts both with and without a detailed geometric characterization of their pump such that minimal information is required to achieve a realistic working model, but specific details of a particular pump design may be captured if sufficient information is provided. In addition, heat generated from pump operation and its transport through the plant system can be modeled to better capture the behavior of certain transients. This paper will outline the model and derive the governing equations of the new EM pump model. An initial comparison between the simple EM pump model and experimental data is made. This comparison shows that the equivalent circuit model can capture pump performance, with greater accuracy near the rated conditions. In order to demonstrate the transient behavior of the new model, a simple transient with an EM pump replacing the centrifugal pumps in the Advanced Burner Test Reactor is included.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Status of EM Pump Modeling Capability for VTR

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. Most recently, SAS4A/SASSYS-1 has been selected as the safety analysis software for the Versatile Test Reactor (VTR), a new materials testing Sodium Fast Reactor (SFR) to be built by the Department of Energy. In order to support analysis of the VTR, which will utilize ElectroMagnetic (EM) pumps as the primary coolant pumps, the development of new EM pump modeling capabilities has been initiated for SAS4/SASSYS-1. The new physics-based EM pump model captures systems-level transient performance based on equivalent circuit theory and is highly flexible to model a wide range of electromagnetic pumps of the three-phase linear induction type subject to changes in power supply and plant conditions. Within the equivalent circuit framework, two sub-models are developed to provide options for analysts both with and without a detailed geometric characterization of their pump such that minimal information is required to achieve a realistic working model, but specific details of a particular pump design may be captured if sufficient information is provided. In addition, heat generated from pump operation and its transport through the plant system can be modeled to better capture the behavior of certain transients. This paper will outline the model and derive the governing equations of the new EM pump model. An initial comparison between the simple EM pump model and experimental data is made. This comparison shows that the equivalent circuit model can capture pump performance, with greater accuracy near the rated conditions. In order to demonstrate the transient behavior of the new model, a simple transient with an EM pump replacing the centrifugal pumps in the Advanced Burner Test Reactor is included.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multi-objective optimization of CEBAF heat load management and trip rates using AI/ML

The goal of this project is to investigate the use of RL to simultaneously optimize the cryogenic heat load and trip rate of the CEBAF linacs and make it generic to solve multi-objective problems that will enable its application at other Department of Energy (DOE) facilities with similar challenges. The existing approach optimizes the gradient distribution to minimize the trip rate and does not take into account the total heat load. A secondary objective of the project is the develop a framework to correct cavity quality curves (Q-curves) or RF-heat to Gradient relation curves for individual cavities. These curves are currently obtained using historical measurements and may have changed their behavior due to various events. Correction in these curves will allow us to accurately approximate the total RF heat generated by the linacs which is critical for the optimization.

43 PARTICLE ACCELERATORS↗

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

As an alternative to a steam cycle, a supercritical carbon dioxide (sCO2) power cycle can be considered. Able et. al performed an analysis of an sCO2 cycle in a 2x2-1 configuration; however, this study did not include carbon capture. Previous studies assumed an H-Frame turbine and added a solvent based 95% carbon capture system and performed a levelized cost of electricity (LCOE) optimization for the plant. Their results suggest a LCOE slightly better than when using a steam cycle. In the study, steam is still generated in the heat recovery sections for the solvent regeneration in the carbon capture stripper reboiler. H-Frame gas turbines are also assumed. This work starts with the optimal design from the mentioned work to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. H-Frame gas turbine off-design performance and exhaust conditions to the heat recovery section are obtained from commercial software, Thermoflow®. The CO2 turbomachinery, heat exchangers and other unit operations are sized and implemented in an Aspen Plus® model. Using the gas turbine exhaust conditions as input, the sCO2 cycle is optimized by adjusting stream split ratios, sCO2 circulation flowrate and compressor speed for maximum efficiency. This is done while keeping the target 95% CO2 capture.

Chinen, Anderson Soares↗

Implementation of an Experimental Setup Based on the Three-Omega Method for Thermal Conductivity Measurements of Molten Salts

Molten salt reactors (MSRs) are one of the most promising next-generation nuclear reactor designs which use molten salts as the fuel and coolant. To design, model, predict, license, and operate MSRs, the behavior of the fuel and coolant must be understood as a function of temperature and irradiation, i.e., burnup. Of particular importance and complexity is the reliable and reproducible measurement of thermal conductivity of molten salts at high temperatures (> 500 °C). Thermal conductivity provides information on the rate at which heat passes through a specified material and is dependent on chemical composition. Currently, in the national laboratory complex, several methods for measuring thermal conductivity on molten salt systems are under development, however, to date, consistent data have not been produced. Typically, thermal conductivity measurements of high-temperature melts have been conducted by using the Transient Hot Wire (THW) method where thermal conductivity is determined by the change in temperature over time at a certain distance from a heating wire. Another time-dependent technique is the laser flash method, commonly used for solid samples. Laser flash requires prior measurements of density and heat capacity to calculate the thermal conductivity of the sample, introducing additional measurement errors. Steady state and time-dependent measurements such as THW and laser flash have errors from convection and ambient temperature fluctuations (heat radiation). In order to produce high fidelity thermal conductivity data, a measurement technique needs to be developed that will reduce the effect of convection at high temperatures by measuring in a very fast time window. In addition, to measure on actinide and irradiated salts the sample size should be small. Therefore, this project aims to develop a frequency-domain technique based on the three-omega (3?) method, previously proven to work on solids, nanofluids and low temperature solar salts (25 to 250 °C). If the 3?-device can be designed with materials that can withstand high temperatures (>500 °C) and can be configured to reduce errors due to convection, then it would prove to be a valuable technique for ensuring thermal conductivity on molten salt systems needed for MSR development. For this proposal, the 3? instrument will be designed, assembled, and tested on non-radioactive salts before being used on actinide bearing salts. In addition, a thermal model will be developed to determine the thermal conductivity of the sample from the measured thermal oscillation of the sensor. Because 3? is a direct method that requires a small volume of sample and works in a very fast time window, it will aid in suppressing the interference due to convection which is ideal when working with high temperature liquid samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact on Cycle Efficiency of Small Combined Heat and Power Plants from Increasing Firing Temperature Enabled by Additive Manufacturing of Turbine Blades and Vanes

The results of this study show that a 180°F (100°C) increase in firing temperature can increase the gas turbine efficiency by 1 percentage point without improving cooling effectiveness and add 2 additional percentage points in efficiency by using advanced turbine blades with higher internal cooling efficiency. The engine upgrades evaluated in this study show potential for increasing the CHP cycle efficiency by 3 percentage points while increasing the steam generation rate by 8%.

Uysal, Selcuk Can↗

Activation Analysis for the Inboard Region of FNSF Using SERPENT

This study describes an application of the SERPENT 2 code with the TENDL-2017 nuclear data library and the latest available model features of the Fusion Energy System Studies–Fusion Nuclear Science Facility (FNSF), to evaluate the activation of components after shutdown at 1, 10, and 100 years, assuming a plant lifetime of 8.5 full-power years. The primary parameters evaluated include the specific activity, decay heat, and waste disposal rating (WDR). The specific activity and decay heat are calculated with SERPENT 2 using a 360-deg model of the FNSF, while the WDR is calculated and classified based on the waste disposal limits established by the U.S. Nuclear Regulatory Commission under 10 CFR 61.55 as well as by using the Fetter approach. A python-based script developed for a previous high-level waste classification and analysis study was implemented and adapted to this research to calculate the WDR by comparing nuclide concentrations to the values established in 10 CFR 61.55 to generate a waste classification for each component surveyed. As only three short-lived isotopes have limitations for classifications beyond Class A, of which only 63Ni is present in appreciable quantities, there is a limit to the amount that short-lived isotopes contribute to the most significant waste analyzed here. In most cases, a handful of long-lived isotopes can be problematic, such as 59Ni and 94Nb, for example, which are solely responsible for multiple Class C classifications. The results herein reported heavily depend on the specific materials and mass/volume fractions in the specific model used in this study, which has changed and evolved since the inception of the FNSF concept and past studies. Furthermore, the more significant contributions of this study may be the development of a modeling and simulation toolkit and a strategy to perform these calculations, so to help evaluate and optimize future fusion facilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design complexity and performance analysis in additively manufactured heat exchangers

The main objective of this research is to investigate the tradeoffs between design complexity and thermal performance in additively manufactured metallic heat exchangers. Such heat exchangers have become a favorite topic for investigation in various fields ranging from air conditioning to aircraft gas turbine engines. In particular, high manufacturing cost has emerged as the major drawback in broad applications of manifold-microchannel heat exchanger (MMHXs). The possibility of cost-effective manufacturing has generated wide interest in applying additive manufacturing (AM) for fabricating MMHXs. Furthermore, AM technologies will provide an opportunity for enhanced design and superior heat transfer performance. In this study, innovative MMHXs are designed and fabricated through selective laser melting. An experimental setup was designed to measure pressure drop and heat transfer for the developed MMHXs with a wide range of Reynolds numbers. Furthermore, the coefficient of performance was calculated based on the heat flow rate, air pressure drop, and air flow rate. Measurement results demonstrated that in some scenarios adding more internal features, i.e., increasing design complexity, does not necessarily improve the MMHX performance.

10 SYNTHETIC FUELS↗

Emulation of neutron-irradiated microstructure of austenitic 21Cr32Ni model alloy using dual-ion irradiation

Here, in this study, the capability of heavy-ion irradiation to emulate neutron irradiation was demonstrated on an austenitic 21Cr32Ni type ternary model alloy. The model alloy used in this study is chemically analogous but compositionally simpler than of alloy 800H, which is a candidate austenitic Ni alloy which has been proposed for use in Generation IV reactors. The microstructure of the 21Cr32Ni model alloy irradiated in the BOR-60 fast reactor to 17.1 dpa and 35 dpa at ~380°C was characterized using transmission electron microscopy (TEM). The 17.1 dpa BOR-60 irradiated microstructure was then compared with the microstructure of the same material developed under dual-ion (DI) irradiation using various He/dpa ratios between 0.1 and 16.6 appm He/dpa in the temperature range of 430°C-500°C. The results showed that both neutron and DI irradiation of 21Cr32Ni model alloy produced dislocations in the form of a dislocation network as well as {111}-type faulted dislocation loops, cavities, and radiation-induced Ni enrichment at radiation-induced sinks. When the dose and the He/dpa ratio were kept similar to those in neutron irradiation, DI irradiation of the 21Cr32Ni model alloy at 460°C resulted in over-nucleation of small cavities and in a high density of faulted dislocation loops compared to those observed in the fast-neutron irradiated alloy of the same heat irradiated at ~380°C. The optimal condition for reproducing the neutron-irradiated microstructure was DI irradiation at 460°C and 0.1 appm He/dpa. In that case, the faulted loop and cavity size distributions in the BOR-60 irradiated 21Cr32Ni model alloy samples closely matched with those measured in the DI irradiated 21Cr32Ni model alloy sample. The fact that the He/dpa is an order of magnitude smaller than the helium generation rate for fast neutron irradiation, stops over nucleation and allows for the development of a similar microstructure as for neutron irradiation.

21Cr32Ni model alloy↗

Enhanced Cloud Top Longwave Radiative Cooling Due To the Effect of Horizontal Radiative Transfer in the Stratocumulus to Trade Cumulus Transition Regime

Abstract Recent studies develop the SPeedy Algorithm for Radiative TrAnsfer through CloUd Sides (SPARTACUS) to handle the influence of horizontal RT on vertical radiative fluxes within an atmospheric column. The present study applies SPARTACUS to large eddy simulation (LES)‐generated cloud fields across the stratocumulus to trade cumulus transition (STCT) regime with coarse and fine vertical resolutions. The results show that, as the vertical resolution increases, radiation simulations show increasingly stronger cloud‐top longwave (LW) radiative cooling. Consequently, the sharp radiative heating gradient across the cloud layer in the LES‐like resolution simulations cannot be resolved with the coarse resolution simulations. Including the horizontal RT typically enhances cloud LW radiative cooling rate by less than 10% for all the cloud fields but more significantly in the cloud fields during the STCT. The enhanced cloud LW radiative cooling also occurs in the lower cloud layer in the decoupled cumulus cloud regime.

Geology↗

Wear in particle based CSP systems from particle abrasion and attrition at high temperature

High temperature particle-based receivers offer distinct advantages over conventional molten salt receivers due to their ability to achieve temperatures above 700 ºC, direct absorption of solar energy as they fall through a beam of concentrated sunlight, and the relative ease of storage (and retrieval using a secondary working fluid) in insulated storage tanks. The use of particles, however, also raises concerns with material degradation from the flow of hot or cold particles through discharge hoppers or along the inner receiver surfaces and other system components (e.g. tubes, valves etc.), depending on operating mode of the receiver. The flow of particles over surfaces may result in loss of material from abrasive wear, impact erosion from impingement under gravitational fall and particle attrition as particles fall and move on top of each other. In the present study, the performance of candidate materials and particles were evaluated through a series of abrasion erosion and particle attrition experiments at room temperature as well as at 800 °C. Candidate materials were subject to abrasive wear from particles at low particle to material velocities inside a resistance heated kiln, and analyzed for changes in mass and surface morphology using cross-sectional scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS) tests. The wear rate for different specimens was noted to be largely driven by the strength of chromia scales built on the specimens from exposure to high temperature. Particle attrition measurements explored the susceptibility of particles to breakdown from particle to particle interaction and the generation of fines from this process. At the low velocities expected in particle based CSP plants, the particles tested exhibited near negligible breakdown. However, changes in the particle hardness at 800 ºC resulted in a significantly higher particle breakdown to sizes <40 microns raising potential environmental concerns. In addition to particle breakdown, it was also noted that the sample had oxides from the stainless steel test setup mixed in with the particles. Similar oxides can be expected to turn up in the utility scale particle based CSP plants as well. The presence of oxide was also noted to affect the solar absorptivity of the mixture compared to a clean initial specimen, potentially resulting in a change in the overall efficiency of the CSP plant.

14 SOLAR ENERGY↗

Application of a Heat Integrated Post-combustion CO 2 Capture System with Hitachi Advanced Solvent into Existing Coal-Fired Power Plant (Final Technical Report)

The goal of this final project report is to comprehensively summarize the work conducted on project DE-FE0007395. In accordance with the Project Management Plan (PMP), Revision F dated 5/10/2019, and Statement of Project Objectives (SOPO) within, the University of Kentucky (UK) Center for Applied Energy Research (CAER) (Recipient) has successfully demonstrated a unique, versatile CO 2 capture system (CCS) using a heat integrated process combined with two-stage stripping for process intensification, heat recovery and demineralized (DM) water generation. This project involved the design, fabrication, installation, testing of and data analysis from the UK CAER 0.7 MWe small pilot scale CO2 capture process installed at Kentucky Utilities (KU) E.W. Brown Generating Station in Harrodsburg, KY. During each of the four project Budget Periods (BPs), UK CAER met all project deliverables, all project milestones, with National Energy Technology Laboratory (NETL) approved adjustments made to the campaign long-term hours during BP4. The CCS was constructed in modular skids. Two solvent campaigns were initially conducted; the first with a 30 wt% monoethanolamine (MEA) as a baseline, and the second with the Hitachi H3-1 advanced solvent. Additional tests were performed with two advanced solvents including CAER and Proprietary Solvent C. Short-period testing with a higher concentration of 40 wt% MEA was conducted to evaluate the potential saving with high alkalinity. From the various solvent campaigns, unique aspects of the UK CAER CCS technology, as well as its flexibility and versatility were experimentally validated and demonstrated. With respect to solvent evaluation efforts in identifying candidates with significant operational and capital cost savings potential, performance of solvents were evaluated to determine the energy requirements for regeneration; environmental impacts from secondary emissions and degradation products; degradation rates, solvent make-up rates and stability. The assessments were done from parametric tests that determined optimum operating conditions for the individual solvents to maximize process efficiency and minimize the parasitic load of the power plant, and from long term campaigns (1000 hours for 30 wt% MEA and 1000 hours for H3-1) which collectively informed the techno-economic analyses (TEA) of the process. The long term campaigns included corrosion studies which used three types of metal coupons in different sections of the process: (absorber, primary stripper, lean carbon-loaded and rich carbon loaded flow streams in process) to mimic heat and flow dynamics process equipment were exposed to. The estimated corrosion rates were used to elucidate corrosion mechanisms and to further guide process material selection for potential capital cost savings.

gas separation↗