Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heating loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Next Generation Thermal Protection System for Outer Planet Probes and Orbiter

Saturn Probe and Ice Giant Orbiter along with in-situ Probe Missions continue to be very high priority mis-sions. A result of the advocacy by OPAG and other Analysis Groups, the 3D Woven, Dual-Layer HEEET thermal protection system, mature at TRL 6, has closed the TPS gap for extreme environment missions. A mid density follow on to DL HEEET, developed to meet earth entry requirements, is a Single Layer vari-ant of the 3D woven TPS, which provides a mass effi-cient single layer 3D Mid-Density TPS (3MDCP) that has been baselined as the heatshield for MSR EEV. Continued development of 3MDCP will elevate it to TRL 6 by 2025. Conformal-PICA (C-PICA) devel-opment was pursued to establish a more efficient and robust alternate to PICA, and it is at TRL 4+. Our rationale for the next generation of TPS de-velopment is based on the on the missions needs of the next decade Outer Planet missions that are unique and more demanding than any other destinations. Taking advantage of the recent planned development of sev-eral materials, the next generation of TPS offers a much more mass efficient option for small, medium, and large class Outer Planet missions. Saturn Probes: While mission designers are gen-erally interested in shallow entry to maintain the g-load during entry around 50g, the heat-load for shallow entry can range between (100 kJ/cm2 – 300 kJ/cm2), two orders of magnitude higher than Venus or Sample Return missions. TPS must not only offer protection but must be mass efficient to perform reasonable sci-ence. TPS mass can quickly become 50% or more of the mass of the entire entry system. Recent analysis performed shows Saturn Probe missions could signifi-cantly benefit from the single layer HEEET (SL-HEEET/3MDCP). A DL-HEEET based heatshield mass could be ~ (40% -50%), SL-HEEET can provide additional (30% - 50%) mass savings. At the same time, C-PICA can provide (30% - 50%) mass savings on the backshell. The combined mass savings can be significant enough to carry an additional probe, if de-sired. Ice Giant Aerocapture Missions: Aerocapture mission architectures can provide significant ad-vantage over traditional propulsive insertion missions in multiple ways. 1) Reduced trip time ~ (4- 6) years (30% -40%), 2) Enables placing the orbiter, probe, and lander, all together and 3) Allows for greater science mass (probes and landers) due to mass efficiency. The delivery of a probe from orbit makes it easier and eliminates mission design constraints by HEEET for direct entry [4] of probes and allows for more targeted in-situ science once the Orbiter is able to collect data. In the past 20 years, progress made in GN&C for lift-guided entry missions (MSL, Orion EFT1, Mars 2020) and the expertise in blunt body aerodynamics at large scale (~ 5m) has led the EDL community to conclude that aerocapture is a “go do” engineering activity. An aerocapture mission that will deplete the excess energy of a fast arrival mission will require a mass efficient TPS that can handle extreme heat-load, ~ (100 kJ/cm2 – 500 kJ/cm2). Hence TPS, feasibility as well as mass efficiency requires assessment. Utilizing the recent developments, a comprehensive, bounding analysis was done to establish the potential for SOA (HEEET) system as well as emerging new TPS such as SL-HEEET and C-PICA. In this proposed poster, we will outline the process by which we establish bounding aerocapture trajecto-ries for hyperbolic excess velocities ranging from 27 km/s to 35 km/s, for low L/D (~ 0.4) configurations and determine conservative/bounding estimate of aer-othermal environment by using a combination of CFD simulations and stagnation point heating estimates [7]. This engineering approach allows us to assess the TPS need vs. TPS capability and determine the applicability of existing TPS. Once an applicable suite of TPS is determined, the TPS thickness and mass are comput-ed. We show that the TPS mass fraction can be as low as 5% to as high as 20%, depending on the use of ad-vanced TPS, while HEEET is sufficient but will require 50% of the entry mass.

E Venkatapathy↗

Radiator heat rejection options for Shuttle payloads

The paper describes four separate advanced space radiator concepts that have been pursued in an integrated effort to develop multipayload use, low-cost heat rejection systems which can overcome the limitations of current radar systems. These four concepts are the following: (1) a wide heat load range, modularized space radiation system; (2) a heat rejection subsystem designed as a compact self-contained heat rejection module which provides a refrigeration cycle to accomodate a wide variation in payload heat loads and cooling temperature requirements; (3) a lightweight flexible fin radiator system with heat rejection capability; and (4) a radiator which does not require a circulating coolant on the radiator panel with heat pipes and thus particularly applies to very-long-duration free-flying payloads where long life reliability is an overriding design parameter. The Orbiter active thermal control system is briefly described.

Ellis, W. E.↗

Loading and heating of a large flat plate at Mach 7 in the Langley 8-foot high-temperature structures tunnel

Surface pressure and cold-wall heating rate distributions (wall-temperature to total-temperature ratio approximately 0.2) were obtained on a large, flat calibration panel at a nominal Mach number of 7 in an 8-foot high-temperature structures tunnel. Panel dimensions were 42.5 by 60.0 in. Test objectives were: (1) to map available flat-plate loading and heating provided by the facility and (2) to determine effectiveness of leading-edge bluntness, boundary-layer trips, and aerodynamic fences in generating a uniform, streamwise turbulent flow field over the test surface of a flat-sided panel holder.

Deveikis, W. D.↗

Evaluation of boundary layer transition criteria for space shuttle orbiter entry

A comparison was made of the effect of boundary layer transition on center-line heating in a conical and a normal-shock flow field. It was shown that the time of transition onset (and, hence, the heating parameter) is significantly influenced by the choice of transition criterion in the normal-shock flow but that this parameter is much less sensitive to the transition criterion in a conical flow field. An evaluation of the effects of boundary layer transition on center-line heating in the conical flow field has shown that the temperatures are less affected by the use of various transition crieria than are heat loads. This difference is due to the delay in the time of transition onset predicted by those criteria with high transition Reynolds numbers. The criteria which predict the most severe thermal environment are those of fully turbulent flow throughout the entry, because transition occurs early in the trajectory for each of these criteria, they tend to predict similar values of maximum temperature and total heat load especially at center-line locations aft of 0.6. Evaluation of center-line heating generated by various trajectory shaping approaches has shown that the maximum surface temperature distribution was not significantly affected by the shaping technique. However, the heat load distribution is influenced, particularly on the forward portion of the vehicle.

Helms, V. T., III↗

Space radiator trade studies for the 25 kW Power System

Advanced radiator designs which will survive the meteoroid hazard of near earth orbit for five years are evaluated for the 25 kW Power System. Weight comparisons of heat pipe radiators and pumped fluid radiators incorporating meteoroid bumpers are presented for the initial 25 kW Power System and growth versions to 250 kW. The heat pipe concept is enhanced by a new design of the thermal interface between the heat pipe and coolant loop. The results show small weight differences between the advanced heat pipe and pumped fluid concepts for heat loads up to about 50 kW. The heat pipe panels have a weight advantage for larger heat loads.

Howell, H. R.↗

The heating environment during Martian atmospheric descent

It has been shown that a vehicle with a lift/drag ratio of 2.3 entering the Martian atmosphere at parabolic speed of 5 km/sec, or from a low orbit at 3.5 km/sec, has a very large landing footprint. At the 5-km/sec entry speed, the trajectory exhibits large skipping motions; however, a lateral range of up to 3300 km is attainable. The entries from low satellite orbit yield a gliding lateral range of 2500 km. The distances correspond to latitude changes of 57 and 42 deg, respectively. The high-speed, skipping entries were accompanied by the most intense heating. The peak stagnation point convective rates varied from 59 W/sq cm to 88 W/sq cm for partially and fully catalytic walls, respectively; the corresponding equilibrium wall temperatures were 1900 K and 2100 K. The peak heating at a wing leading-edge point reached 50 W/sq cm because of the presence of a transitional boundary layer. The lower-speed, gliding entries experienced much milder heating with a peak stagnation point rate of about 14 W/sq cm, resulting in a wall temperature near 1300 K. However, the longer duration of the gliding entries resulted in comparable heat loads for both entry speeds. The highest heat loads approached values experienced by the Shuttle orbiter stagnation point during a typical entry.

Tauber, Michael E.↗

A Morphing Radiator for High-Turndown Thermal Control of Crewed Space Exploration Vehicles

Spacecraft designed for missions beyond low earth orbit (LEO) face a difficult thermal control challenge, particularly in the case of crewed vehicles where the thermal control system (TCS) must maintain a relatively constant internal environment temperature despite a vastly varying external thermal environment and despite heat rejection needs that are contrary to the potential of the environment. A thermal control system may be required to reject a higher heat load to warm environments and a lower heat load to cold environments, necessitating a relatively high turndown ratio. A modern thermal control system is capable of a turndown ratio of on the order of 12:1, but crew safety and environment compatibility have constrained these solutions to massive multi-loop fluid systems. This paper discusses the analysis of a unique radiator design that employs the behavior of shape memory alloys (SMAs) to vary the turndown of, and thus enable, a single-loop vehicle thermal control system for space exploration vehicles. This design, a morphing radiator, varies its shape in response to facesheet temperature to control view of space and primary surface emissivity. Because temperature dependence is inherent to SMA behavior, the design requires no accommodation for control, instrumentation, or power supply in order to operate. Thermal and radiation modeling of the morphing radiator predict a turndown ranging from 11.9:1 to 35:1 independent of TCS configuration. Coupled thermal-stress analyses predict that the desired morphing behavior of the concept is attainable. A system level mass analysis shows that by enabling a single loop architecture this design could reduce the TCS mass by between 139 kg and 225 kg. The concept has been demonstrated in proof-of-concept benchtop tests.

Cognata, Thomas J.↗

A Morphing Radiator for High-Turndown Thermal Control of Crewed Space Exploration Vehicles

Spacecraft designed for missions beyond low earth orbit (LEO) face a difficult thermal control challenge, particularly in the case of crewed vehicles where the thermal control system (TCS) must maintain a relatively constant internal environment temperature despite a vastly varying external thermal environment and despite heat rejection needs that are contrary to the potential of the environment. A thermal control system is in other words required to reject a higher heat load to warm environments and a lower heat load to cold environments, necessitating a quite high turndown ratio. A modern thermal control system is capable of a turndown ratio of on the order of 12:1, but for crew safety and environment compatibility these are massive multi-loop fluid systems. This paper discusses the analysis of a unique radiator design which employs the behavior of shape memory alloys (SMA) to vary the turndown of, and thus enable, a single-loop vehicle thermal control system for space exploration vehicles. This design, a morphing radiator, varies its shape in response to facesheet temperature to control view of space and primary surface emissivity. Because temperature dependence is inherent to SMA behavior, the design requires no accommodation for control, instrumentation, nor power supply in order to operate. Thermal and radiation modeling of the morphing radiator predict a turndown ranging from 11.9:1 to 35:1 independent of TCS configuration. Stress and deformation analyses predict the desired morphing behavior of the concept. A system level mass analysis shows that by enabling a single loop architecture this design could reduce the TCS mass by between 139 kg and 225 kg. The concept is demonstrated in proof-of-concept benchtop tests.

Cognata, Thomas J.↗

Superfluid helium 2 liquid-vapor phase separation: Technology assessment

A literature survey of helium 2 liquid vapor phase separation is presented. Currently, two types of He 2 phase separators are being investigated: porous, sintered metal plugs and the active phase separator. The permeability K(P) shows consistency in porous plug geometric characterization. Both the heat and mass fluxes increase with K(P). Downstream pressure regulation to adjust for varying heat loads and both temperatures is possible. For large dynamic heat loads, the active phase separator shows a maximum heat rejection rate of up to 2 W and bath temperature stability of 0.1 mK. Porous plug phase separation performance should be investigated for application to SIRTF and, in particular, that plugs of from 10 to the minus ninth square centimeters to 10 to the minus eighth square centimeters in conjunction with downstream pressure regulation be studied.

Lee, J. M.↗

Summary of Testing Results for the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER)

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The baseline SHIIVER design consists of uninsulated structural skirts attached to a propellant tank insulated with polyurethane Spray-On Foam Insulation (SOFI). The initial testing of the SHIIVER hardware was with liquid hydrogen and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI on the tank domes, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full, with and without MLI installed on the domes. The MLI installed on the domes reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed after exposure to the acoustic environment. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads

SHIIVER↗

Development of steady-state operation using ICH in the LHD

Long-pulse discharge with the electron density n{sub e0} of 1 × 10{sup 19} m{sup −3}, electron temperature T{sub e0} of 2.5 keV, discharge length t{sub dis} of 19 minutes and heating power P{sub inject} of 1MW, is demonstrated using the HAS antenna and the PA antenna for ion cyclotron heating (ICH) and increasing in the power of electron cyclotron heating (ECH). The HAS antenna is designed to phase dipole and excite ideal fast wave with parallel electric field kept small, and low impurity generation and accumulation are achieved on the steady-state discharge by weak parasitic heating around antennas. On the long-pulse discharge, the radiation measured by bolometer is kept smaller than 20% for injection power, and the heat load to divertor is approximately 60 % with low energetic particle losses. The heat load ratio to divertor is not as a function of injection power around 1MW, and energy confinement has been kept during the steady-state discharge.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cooling the dark energy camera instrument

DECam, camera for the Dark Energy Survey (DES), is undergoing general design and component testing. For an overview see DePoy, et al in these proceedings. For a description of the imager, see Cease, et al in these proceedings. The CCD instrument will be mounted at the prime focus of the CTIO Blanco 4m telescope. The instrument temperature will be 173K with a heat load of 113W. In similar applications, cooling CCD instruments at the prime focus has been accomplished by three general methods. Liquid nitrogen reservoirs have been constructed to operate in any orientation, pulse tube cryocoolers have been used when tilt angles are limited and Joule-Thompson or Stirling cryocoolers have been used with smaller heat loads. Gifford-MacMahon cooling has been used at the Cassegrain but not at the prime focus. For DES, the combined requirements of high heat load, temperature stability, low vibration, operation in any orientation, liquid nitrogen cost and limited space available led to the design of a pumped, closed loop, circulating nitrogen system. At zenith the instrument will be twelve meters above the pump/cryocooler station. This cooling system expected to have a 10,000 hour maintenance interval. This paper will describe the engineering basis including the thermal model, unbalanced forces, cooldown time, the single and two-phase flow model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of dynamics of ELM crashes and their mitigation techniques

The accurate prediction of H-mode pedestal dynamics is critical for planning experiments in existing tokamaks and in the design of future tokamaks such as ITER and DEMO. The main objective of the proposed research is to advance the understanding of the physics of H-mode pedestal. Through advances in coupled kinetic-MHD simulations, a new model for H-mode pedestal and ELM crashes as well as an improved model for the bootstrap current will be developed. ELMmitigation techniques will also be investigated. The proposed research will help design efficient confinement scenarios and reduce transient heat loads on the divertor and plasma facing components. During the last two years, the principal investigator (PI) of this proposal actively participated in physics studies related to the DOE Joint Research Targets. These studies include the modeling of divertor heat load in the DIII-D, Alcator C-Mod, and NSTX tokamaks in 2010, and the modeling of H-mode pedestal structure in the DIII-D tokamak in 2011. It is proposed that this close collaboration with experimentalists from major US tokamaks continue during the next funding period. Verification and validation will be a strong component of the proposed research. During the course of the project, advances will be made in the following areas; Dynamics of the H-mode pedestal buildup and recovery after ELM crashes – The effects of neutral fueling, particle and thermal pinches will be explored; Dynamics of ELM crashes in realistic tokamak geometries – Heat loads associated with ELM crashes will be validated against experimental measurements. An improved model for ELM crashes will be developed; ELM mitigation – The effect of resonant magnetic perturbations on ELMs stability and their evolution will be investigated; Development of a new bootstrap current model – A reduced model for will be developed through careful verification of existing models for bootstrap current against first-principle kinetic neoclassical simulations. The primary focus here will be on plasma regimes where the existing reduced models deviate from each other, such as high-beta and low aspect ratio plasmas; and Results will be verified against analytical models and simulation results from other codes. Simulation results will be compared with diagnostic experimental data such as Thomson measurements (HRTC) or flux measurements if available. We have arrangements with experimentalists from DIII-D and JET to use diagnostic edge data for this validation. In summary, we propose to study the H-mode pedestal buildup, the stability and evolution of ELMs using a model that will account for dynamically evolving neoclassical sources.

42 ENGINEERING↗

Design and Analysis of High Heat Flux Plasma-Facing Components for NSTX Upgrade

The National Spherical Tokamak Experiment (NSTX) upgrade (NSTX-U) requirements lead to enhanced heat loads on plasma-facing components (PFCs) especially in the divertor regions, where normal heat flux density can reach up to 8 MW/m 2 . For these high heat flux (HHF) regions, the PFCs were redesigned, to use castellations which relieved the thermal stresses associated with high incident heat flux. Another design feature of HHF PFCs is the absence of front face mounting holes which create localized areas of high temperature and thermal stress concentrations. Optimized shaping of the front face of the HHF PFCs eliminates regions where the front face is perpendicular to the heat flux direction during normal helicity operation and spreads the heat load. A unique mechanism was designed to connect PFC tiles to the NSTX-U center stack casing using locking features accessible from the low heat flux regions. Isotropic graphite was selected as the HHF PFC tile material. Initial tile design parameters were accessed using analytical expressions for pulsed heat flux loading. A working prototype of the locking mechanism was created during the initial stages of the design to prove the concept performance. This article presents an overview of the divertor HHF PFC design and the results of the thermal and structural analyses performed using ANSYS software. The results of the analyses cover normal operating conditions and disruptions which impose electromagnetic (EM) loads from eddy and halo currents. The 3-D, transient, nonlinear analyses took into account the temperature-dependent properties of the materials, friction interfaces between the parts, and variable electric properties of the parts and interfaces. The results confirm that the HHF PFC tiles remain within the allowable limits for the loads defined by the NSTX-U Recovery Project. In addition, tolerance stack up analyses were performed to ensure tile performance in the worst possible assembly configuration. Finally, the design process was completed successfully, and the NSTX HHF PFC tiles are currently in the production phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transient Convection Due to Imposed Heat Flux: Application to Liquid-Acquisition Devices

A model problem is considered that addresses the effect of heat load from an ambient laboratory environment on the temperature rise of liquid nitrogen inside an enclosure. This model has applications to liquid acquisition devices inside the cryogenic storage tanks used to transport vapor-free propellant to the main engine. We show that heat loads from Q = 0.001 to 10 W, with corresponding Rayleigh numbers from Ra = 109 to 1013, yield a range of unsteady convective states and temperature rise in the liquid. The results show that Q = 1 to 10 W (Ra = 1012 to 1013) yield temperature distributions along the enclosure height that are similar in trend to experimental measurements. Unsteady convection, which shows selfsimilarity in its planforms, is predicted for the range of heat-load conditions. The onset of convection occurs from a free-convection-dominated base flow that becomes unstable against convective instability generated at the bottom of the enclosure while the top of the enclosure is convectively stable. A number of modes are generated with small-scale thermals at the bottom of the enclosure in which the flow selforganizes into two symmetric modes prior to the onset of the propagation of the instability. These symmetric vertical modes transition to asymmetric modes that propagate as a traveling-wave-type motion of convective modes and are representative of the asymptotic convective state of the flow field. Intense vorticity production is created in the core of the flow field due to the fact that there is shear instability between the vertical and horizontal modes. For the higher Rayleigh numbers, 1012 to 1013, there is a transition from a stationary to a nonstationary response time signal of the flow and temperature fields with a mean value that increases with time over various time bands and regions of the enclosure.

Duval, Walter M. B.↗

Resistive wall heating due to image current on the beam chamber for a superconducting undulator

The image-current heating on the resistive beam chamber of a superconducting undulator (SCU) was calculated based on the normal and anomalous skin effects. Using the bulk resistivity of copper for the beam chamber, the heat loads were calculated for the residual resistivity ratios (RRRs) of unity at room temperature to 100 K at a cryogenic temperature as the reference. Then, using the resistivity of the specific aluminum alloy 6053-T5, which will be used for the SCU beam chamber, the heat loads were calculated. An electron beam stored in a storage ring induces an image current on the inner conducting wall, mainly within a skin depth, of the beam chamber. The image current, with opposite charge to the electron beam, travels along the chamber wall in the same direction as the electron beam. The average current in the storage ring consists of a number of bunches. When the pattern of the bunched beam is repeated according to the rf frequency, the beam current may be expressed in terms of a Fourier series. The time structure of the image current is assumed to be the same as that of the beam current. For a given resistivity of the chamber inner wall, the application of the normal or anomalous skin effect will depend on the harmonic numbers of the Fourier series of the beam current and the temperature of the chamber. For a round beam chamber with a ratius r, much larger than the beam size, one can assume that the image current density as well as the density square, may be uniform around the perimeter 2πr. For the SCU beam chamber, which has a relatively narrow vertical gap compared to the width, the effective perimeter was estimated since the heat load should be proportional to the inverse of the perimeter.

43 PARTICLE ACCELERATORS↗

NUHOMS{sup R} EOS (Extended Optimized Storage): Robust, Advanced, and Dual Purpose Dry Storage System - 16472

AREVA TN has completed the design, analysis, and US NRC license submittal for the NUHOMS{sup R} Extended Optimized Storage (EOS) system. NUHOMS{sup R} EOS offers a large capacity and high heat load dry storage and transportation solution for UNF. EOS is not a new system, but an evolution of the already-proven safe and low-risk horizontal NUHOMS{sup R} storage system, which is one of the most widely used UNF dry storage systems in the United States. The EOS system features a 37PTH dry shielded canister (DSC) for 37 PWR UNF assemblies and an 89BTH DSC for the 89 BWR UNF assemblies. The EOS DSCs will be stored inside a horizontal storage module (HSM) that is a robust, fortress-like concrete storage overpack. Designed with the lessons learned from the Fukushima event in Japan in mind, EOS has robust margins for beyond design basis (BDB) events and offers the lowest risk and highest safety margin of any dry storage system design for recovery from BDB events. EOS also offers innovative aging management features with an aging management program (AMP) to assure safe and low dose long-term storage at the utility sites. EOS incorporates ports for AMP inspections and offers the option of using duplex stainless steel (DSS) for the DSC shell in order to negate corrosion issues. EOS is stored horizontally and above ground, making it easy and quick to access for visual inspection, monitoring, and mitigating actions during AMP. NUHOMS{sup R} EOS is optimized for high capacity, high burnup, high enrichments, and very low cooling times for UNF assemblies. It enables the highest heat load per canister (50 kW) and low dose rates. Even with high heat loads, EOS has significant margins to design basis limits. As the future of used fuel disposition will require the need to move fuel off-site to interim or consolidated storage, EOS is the ideal solution as it enables on-site loading and unloading operations that mitigate risk when transferring fuel on-site or transporting fuel off-site. The EOS design can be safely located in a traditional outdoor setting with fortress-like concrete reinforced modules that offer superior resistance to attack or can be safely operated inside of a building enclosure for those utilities desiring a more discreet siting for its used fuel storage systems. EOS has an innovative basket design that is made of high strength low alloy (HSLA) material and is easy to fabricate due to its non-welded design. Its innovative inlet and outlet air vent design, which incorporates dose reduction hardware, allows for optimal ambient airflow for highly efficient heat transfer with minimal radiation dose. The NUHOMS{sup R} EOS storage modules are interlocked in a side-by-side configuration offering superior and robust seismic performance. The license application for NUHOMS{sup R} EOS is currently under US NRC review and this system will be available for deployment in 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of Building Energy Modeling Programs: Building Loads

This technical report presented the methodologies, processes, and results of comparing three Building Energy Modeling Programs (BEMPs) for load calculations: EnergyPlus, DeST and DOE-2.1E. This joint effort, between Lawrence Berkeley National Laboratory, USA and Tsinghua University, China, was part of research projects under the US-China Clean Energy Research Center on Building Energy Efficiency (CERC-BEE). Energy Foundation, an industrial partner of CERC-BEE, was the co-sponsor of this study work. It is widely known that large discrepancies in simulation results can exist between different BEMPs. The result is a lack of confidence in building simulation amongst many users and stakeholders. In the fields of building energy code development and energy labeling programs where building simulation plays a key role, there are also confusing and misleading claims that some BEMPs are better than others. In order to address these problems, it is essential to identify and understand differences between widely-used BEMPs, and the impact of these differences on load simulation results, by detailed comparisons of these BEMPs from source code to results. The primary goal of this work was to research methods and processes that would allow a thorough scientific comparison of the BEMPs. The secondary goal was to provide a list of strengths and weaknesses for each BEMP, based on in-depth understandings of their modeling capabilities, mathematical algorithms, advantages and limitations. This is to guide the use of BEMPs in the design and retrofit of buildings, especially to support China’s building energy standard development and energy labeling program. The research findings could also serve as a good reference to improve the modeling capabilities and applications of the three BEMPs. The methodologies, processes, and analyses employed in the comparison work could also be used to compare other programs. The load calculation method of each program was analyzed and compared to identify the differences in solution algorithms, modeling assumptions and simplifications. Identifying inputs of each program and their default values or algorithms for load simulation was a critical step. These tend to be overlooked by users, but can lead to large discrepancies in simulation results. As weather data was an important input, weather file formats and weather variables used by each program were summarized. Some common mistakes in the weather data conversion process were discussed. ASHRAE Standard 140-2007 tests were carried out to test the fundamental modeling capabilities of the load calculations of the three BEMPs, where inputs for each test case were strictly defined and specified. The tests indicated that the cooling and heating load results of the three BEMPs fell mostly within the range of spread of results from other programs. Based on ASHRAE 140-2007 test results, the finer differences between DeST and EnergyPlus were further analyzed by designing and conducting additional tests. Potential key influencing factors (such as internal gains, air infiltration, convection coefficients of windows and opaque surfaces) were added one at a time to a simple base case with an analytical solution, to compare their relative impacts on load calculation results. Finally, special tests were designed and conducted aiming to ascertain the potential limitations of each program to perform accurate load calculations. The heat balance module was tested for both single and double zone cases. Furthermore, cooling and heating load calculations were compared between the three programs by varying the heat transfer between adjacent zones, the occupancy of the building, and the air-conditioning schedule.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗