Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Performance Storage Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Understanding the Impact of Data Staging for Coupled Scientific Workflows

We report the rate of data generated by cutting-edge experimental science facilities and large-scale simulations enabled by current high-performance computing (HPC) systems has continued to grow at a far greater pace than the development of the network and storage capabilities on which these systems rely. To cope with this challenge, scientist are moving toward the creation of autonomous experiments and HPC simulations using machine learning. However, efficiently moving, storing, and processing large amounts of data away from the point of origin presents an incredible challenge. In-memory computing, in situ analysis, data staging, and data streaming are recognized viable alternatives to traditional file-based methods for transferring data between coupled workflows. However, the performance trade-offs and limitations for these methods are not fully understood when used in HPC applications. This article presents a comprehensive performance assessment of the current solutions for data staging when applied to applications that are not necessary I/O intensive which makes them not ideal candidates for these methods. Our study is based on experiments running at scale on Oak Ridge National Laboratory's Summit supercomputer using applications and simulations that cover typical computational motifs and patterns. We investigated the usability and cost/benefit trade-offs of staging algorithms for HPC applications under different scenarios and highlight opportunities for optimizing the dataflow between coupled simulation workflows.

97 MATHEMATICS AND COMPUTING↗

Numerical modeling and parametric study of a dual purpose underground thermal battery

We report integrating thermal energy storage with building energy systems can enable flexible building electric demands at buildings to help mitigate the mismatch between electricity supply and demand. A novel building heating and cooling system that integrates a dual-source heat pump with hybrid thermal storage named dual-purpose underground thermal battery (DPUTB) has been developed for reshaping building electric demands. The proposed DPUTB integrated geothermal heat pump system is an original innovation that enables Grid-interactive Energy Efficient buildings. This paper focuses on the study of the novel DPUTB. The DPUTB works as both a thermal storage tank (an inner tank) and a ground heat exchanger (an outer tank separated from the inner tank by the insulation material). High fidelity and computationally effective models are needed to predict the performance of the novel DPUTB. This study has developed a simplified dynamic model for the DPUTB according to heat transfer and energy conservation principles and validated it by using experimental data obtained from testing a small-scale DPUTB apparatus. A parametric study was conducted to identify a design that can achieve the target thermal storage performance of load shift and energy efficiency. The parametric study results show that the inner tank shell thermal conductivity and the phase change material's melting point are the two most influencing factors on the performance of the DPUTB. One single full-size DPUTB with the identified design could provide 1-ton cooling (3.51 kW) with the supply temperature lower than 11 °C for 4 hours in summer after being fully charged in 8 hours. The inner tank filled with phase change material is for cooling thermal storage as a latent tank in the design. However, its capacity can be as high as 60 MJ as a sensible water tank for heating storage in winter. In the future study, the DPUTB model will be incorporated into the dual-source heat pump system for evaluating the overall system performance of demand side management in the long term.

25 ENERGY STORAGE↗

Evidence of Zintl Intermediate Phase and Its Impacts on Li and Na Storage Performance of Pb-Based Alloying Anodes

Anode materials based on conversion and alloying reactions are promising to achieve high energy density of advanced sodium-ion batteries (SIBs). While the chemical similarities between sodium and lithium as alkali elements make the benchmarking strategy practical in developing new high-performance anodes, simply borrowing the anode material from one system to the other does not always guarantee success unless it is based on sound understanding of both Li- and Na-reaction mechanisms. In this work, we report the Na storage performance of a Pb-based anode and its fundamental reaction dynamics. In contrast to its excellent electrochemical performances in Li cells (reversible ~600 mAh/g), the newly developed Pb@PbO–C nanocomposite anode has limited electrochemical Na reaction properties showing moderate capacity and rate performances (~300 mAh/g at 20 mA/g). Synchrotron-based X-ray diffraction and absorption spectroscopy studies reveal the fundamental differences in the Na and Li reaction mechanism of the Pb-based anode. Further, unlike Li reaction, the unique Na reaction mechanism involves the formation of a highly ionic NaPb Zintl phase, which comprises tetrahedral Pb 4 clusters, as an intermediate phase. The strong covalent character of the Pb 4 Zintl clusters adversely affects the electronic conductivity and thus limits the electrochemical performance of the Pb-based anode in Na cells. These findings provide new insights applicable to developing high-performance alloying anode materials.

25 ENERGY STORAGE↗

UNITY: Unified Memory and File Space

This paper describes the vision for UNITY, a new high-performance computing focused data storage abstraction that places the entire memory hierarchy, including both traditionally separated memoryand file-based data storage, into one storage continuum. Through the use of a novel API and a set of services centered around a smart runtime system, UNITY is able to provide a number of valuable and interesting benefits. The unified storage space provides a scalable and resilient data environment that dynamically manages the mapping of data onto available resources based on multiple factors, including desired persistence and energy budget considerations. By eliminating the need for high-performance computing domain scientists to develop architecture-dependent optimizations for rapidly evolving data storage technologies, UNITY addresses both ease-of-use and performance.

Otstott, Douglas↗

A core–shell cathode substrate for developing high-loading, high-performance lithium–sulfur batteries

Lithium–sulfur batteries with a high theoretical energy density would be a promising next-generation energy-storage system if their cell-fabrication parameters (e.g., sulfur loading/content and the electrolyte/sulfur ratio) are improved to a practically necessary level. In this article, we report the design of a three-dimensional core–shell carbon substrate, integrating a porous internal core with a conductive external carbon nanofiber shell. Such a carbon substrate encapsulates a high amount of sulfur as the active material core to form a high-loading core–shell cathode, attaining an ultra-high sulfur loading and content of, respectively, 23 mg cm -2 and 75 wt%. With distinguishable internal and external regions, the carbon substrate facilitates the redox reactions and hinders the polysulfide diffusion. Therefore, the core–shell cathodes exhibit a high areal capacity and energy density of, respectively, 14 mA h cm -2 and 27 mW h cm -2 during cycling. During resting, they achieve a long shelf-life of one month with a low capacity-fade rate of 0.25% per day.

25 ENERGY STORAGE↗

Assessment of tank designs for hydrogen storage on heavy duty vehicles using metal hydrides

The objective of this project was to evaluate material-based hydrogen storage solutions as a replacement for high-pressure hydrogen gas or liquid hydrogen on Class 7 or 8 tractor fuel cell electric vehicles. The project focused on low-density main-group hydrides, a well-known class of materials for hydrogen storage. Prior research has considered metal amides as storage materials for light-duty vehicles but not for heavy-duty applications. The project established the basis for further development of storage systems of this type for heavy duty vehicles (HDV). Systems analysis of an HDV storage system comprised of a tank and associated balance of plant (piping, coolant tubes, burner) was performed to determine the usable hydrogen capacity. A composite storage material comprised of a metal hydride mixed with a high thermal-conductivity carbon is predicted to have a usable hydrogen volumetric capacity comparable to or exceeding that of 700 bar pressurized hydrogen gas. The gravimetric capacity of this material is also predicted to be competitive with pressurized gas, particularly if costly carbon fiber composite Type III or Type IV tanks are excluded. The storage system design parameters and material properties served as inputs to a second model that simulates fuel cell operation in conjunction with the storage system during an HDV drive cycle. The results show that sufficient hydrogen pressure can be produced to operate a Class 8 HDV, yielding a range of ~480 miles. These results are particularly relevant for high-impact regions, such as the South Coast Air Quality Management District, for which an economical vehicular hydrogen storage system with minimal impact on cargo capacity could accelerate adoption of heavy-duty fuel cell electric vehicles. An additional benefit is that knowledge generated by this project can assist in development of material-based storage for stationary applications such as microgrids and backup power for data centers.

08 HYDROGEN↗

Probabilistic Multi-Hazard Assessment of Dry Cask Structures

systems the concrete shall not only provide shielding but insures stability of the upright canister, facilitates anchoring, allows ventilation, and provides physical protection against theft, severe weather and natural (seismic) as well as man-made events (blast incidences). Given the need to remain functional for 40 years or even longer in case of interim storage, the concrete outerpack and the internal canister components need to be evaluated with regard to their long-term ability to perform their intended design functions. Just as evidenced by deteriorating concrete bridges, there are reported visible degradation mechanisms of dry storage systems especially when high corrosive environments are considered in maritime locations. The degradation of reinforced concrete is caused by multiple physical and chemical mechanisms, which may be summarized under the heading of environmental aging. The underlying hygro-thermal transport processes are accelerated by irradiation effects, hence creep and shrinkage need to include the effect of chloride penetration, alkali aggregate reaction as well as corrosion of the reinforcing steel. In light of the above, the two main objectives of this project are to (1) develop a probabilistic multi-hazard assessment framework, and (2) through experimental and numerical research perform a comprehensive assessment under combined earthquake loads and aging induced deterioration, which will also provide data for the development and validation of the probabilistic framework.

36 MATERIALS SCIENCE↗

Results of External Technical Reviews of Site Modeling Efforts That Support System Plans

An External Technical Review (ETR) team evaluated the system-level modeling and simulation tools in support of Savannah River Site and Office of River Protection liquid waste processing and disposal systems. The reviews focused on the following primary areas: software and modeling tools, capability to model needed facilities and operations, rate at which predictions are performed, and need for additional tools. The Liquid Waste Disposition Systems at these sites are highly integrated operations that involve safely storing liquid waste in underground storage tanks; removing, treating, and disposing low-activity fraction on-site; vitrifying high-level waste; and storing the vitrified waste until permanent disposition at a Federal Repository. The purpose of the ETR team was to evaluate the current process simulation tools that support the planning basis for life cycle liquid waste disposition system plans. These plans establish a base for processing the constituents of liquid waste systems to the end of the program mission. Observations and recommendations were made for each of the review areas. In general, tools appear to provide reasonable estimates for their intended purposes; however, additional functionality and new tools are needed, as well as greater flexibility and improved performance in producing estimates for planning purposes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy Storage Sizing and Operation of an Integrated Utility-Scale PV+ESS Power Plant

Integration of an energy storage system (ESS) into a large-scale grid-connected photovoltaic (PV) power plant is highly desirable to improve performance of the system and overcome the stochastic nature of PV power generation. Algorithms to size ESS within an integrated PV and ESS ( PV+ESS) power plant, conventionally, require a large number of high-resolution samples of PV generation. These algorithms are computationally expensive. In this paper, a two-day optimization algorithm that utilizes n-step constant power output dispatch every day from the PV+ESS power plant is proposed to size the ESS. Additionally, an n-step power dispatch every day through the one-year timeframe based optimization of the size of ESS is also performed. The proposed methods are computationally cheaper and provide acceptable accuracy with respect to the conventional sizing methods. The economics identified from the proposed methods are compared with the typical day-ahead hourly dispatch-based power production from the PV+ESS power plant. This comparison has shown similar economic performance showcasing the accuracy of the proposed methods in sizing the ESS. It also shows the potential for operating PV+ESS power plant in n-step constant power generation mode.

Xia, Qian↗

Bake

Bake is a microservice (i.e., Mochi provider) for high performance bulk storage of raw data regions. Bake uses modular backends to store data on persistent memory, conventional file systems, or other storage media.

Carns, Phil↗

Advanced Hydrogen-Bromine Flow Batteries with Improved Efficiency, Durability and Cost

The hydrogen/bromine flow battery is a promising candidate for large-scale energy storage due to fast kinetics, highly reversible reactions and low chemical costs. However, today's conventional hydrogen/bromine flow batteries use membrane materials (such as Nafion), platinum catalysts, and carbon-paper electrode materials that are expensive. In addition, platinum catalysts can be poisoned and corroded when exposed to HBr and Br 2 , compromising system lifetime. To reduce the cost and increase the durability of H 2 /Br 2 flow batteries, new materials are developed. The new Nafion/polyvinylidene fluoride electrospun composite membranes have high perm-selectivity at a fraction of the cost of Nafion membranes; the new nitrogen-functionalized platinum-iridium catalyst possesses excellent activity and durability in HBr/Br 2 environment; and the new carbon-nanotube-based Br 2 electrodes can achieve equal or better performance with less materials when compared to baseline electrode materials. Preliminary cost analysis shows that the new materials reduce H 2 /Br 2 flow-battery energy-storage system stack and system costs significantly. The resulting advanced H 2 /Br 2 flow batteries offer high power, high efficiency, substantially increased durability, and expected reduced cost.

25 ENERGY STORAGE↗

Electrolyte additive enabled fast charging and stable cycling lithium metal batteries

Batteries using lithium (Li) metal as anodes are considered promising energy storage systems because of their high energy densities. However, safety concerns associated with dendrite growth along with limited cycle life, especially at high charge current densities, hinder their practical uses. Here we report that an optimal amount (0.05 M) of LiPF6 as an additive in LiTFSI-LiBOB dual-salt/carbonate-solvent-based electrolytes significantly enhances the charging capability and cycling stability of Li metal batteries. In a Li metal battery using a 4-V Li-ion cathode at a moderately high loading of 1.75mAh cm(-2), a cyclability of 97.1% capacity retention after 500 cycles along with very limited increase in electrode overpotential is accomplished at a charge/discharge current density up to 1.75 mA cm(-2). The fast charging and stable cycling performances are ascribed to the generation of a robust and conductive solid electrolyte interphase at the Li metal surface and stabilization of the Al cathode current collector.

25 ENERGY STORAGE↗

Applying Machine Learning to Understand Write Performance of Large-scale Parallel Filesystems

In high-performance computing (HPC), I/O performance prediction offers the potential to improve the efficiency of scientific computing. In particular, accurate prediction can make runtime estimates more precise, guide users toward optimal checkpoint strategies, and better inform facility provisioning and scheduling policies. HPC I/O performance is notoriously difficult to predict and model, however, in large part because of inherent variability and a lack of transparency in the behaviors of constituent storage system components. In this work we seek to advance the state of the art in HPC I/O performance prediction by (1) modeling the mean performance to address high variability, (2) deriving model features from write patterns, system architecture and system configurations, and (3) employing Lasso regression model to improve model accuracy. We demonstrate the efficacy of our approach by applying it to a crucial subset of common HPC I/O motifs, namely, file-per-process checkpoint write workloads. We conduct experiments on two distinct production HPC platforms—Titan at the Oak Ridge Leadership Computing Facility and Cetus at the Argonne Leadership Computing Facility—to train and evaluate our models. We find that we can attain ≤ 30% relative error for 92.79% and 99.64% of the samples in our test set on these platforms, respectively.

Xie, Bing↗

Using Conductive Firebrick Resistance Heating to Enable Very High-Temperature Heat Storage in Nuclear Gas Turbine Systems

In order to economically deploy renewable energy on large scales, affordable energy storage is a must. While the cost of current work storage technologies are too high to deploy in quantities that satisfy renewable energy deployment, heat storage options hold promise for dramatically cheaper storage, which can be used to (1) couple with industrial furnaces or refineries to provide high temperature heat to industry, or (2) couple with air-Brayton cycles to add heat for electricity production. The design space and preliminary performance evaluation for an affordable heat storage concept, called Firebrick Resistance-heated Energy Storage (FIRES), has shown promise for near-term deployment in industrial processes by using readily available materials: metallic resistance heaters for converting electricity to stored heat, and common ceramic firebricks used in furnaces for storing heat at temperatures as high as 1200 deg. C. There however remains serious interest in replacing traditional resistance heaters with electrically conductive firebricks that may serve as both the heating element and the storage medium. The work underway is the experimental development of a high-temperature low-cost electric resistance heater system using conductive firebrick, with the aims of (1) proving that conductive firebrick can be used to replace separate electrical heating system to reduce costs, increase operating temperatures, and increase reliability, and (2) developing methodology to enable design and prediction of performance of such systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hydrodynamic and Structural Response Modeling of a Prototype Floating Membrane Reservoir System for Pumped Storage Hydropower

Hydrodynamic, computational fluid dynamics, and finite-element modeling were performed for a novel floating membrane reservoir system design for closed-loop pumped storage hydropower application. The conceptual design, which is now protected under an invention disclosure with a patent pending, offers a potential low-cost, low-impact solution to address the high costs, long investment return periods, and environmental disruptions encountered with traditional pumped storage development while offering modularity to enable replication at many locations. Prior to physical tests on a prototype, this paper documents the response analysis and modeling completed to simulate hydraulic and structural performance under different reservoir deployment and alignment arrangements, evaluate system stability, and refine the conceptual design. The results indicate that the excitation frequency from vortex shedding is at least an order of magnitude lower than the water sloshing frequencies in the reservoir, the structural natural frequency of the entire reservoir, and the vibrational frequencies of the side membranes, although excitation frequencies from other sources could cause mechanical resonance under certain conditions. To control destabilizing effects and prevent rocking motion and vibration, the authors conclude that the design could be improved by including a support structure around the floating reservoir, which could also provide floating-membrane containment, improve safety, and facilitate vertical reservoir movement. These conclusions, based on hydrodynamic and structural response modeling, help define specifications for upcoming full-scale prototype construction, deployment, and testing. This study demonstrates standard modeling technique application to an innovative design for which similar applications have not been previously evaluated. As a result, the refined design is capable of improving the scalability and feasibility of pumped storage hydropower in the United States and will be considered for commercialization following prototype testing.

13 HYDRO ENERGY↗

Opportunities and data requirements for data-driven prognostics and health management in liquid hydrogen storage systems

During the past decade, Prognostics and Health Management (PHM) has become an important set of tools in various areas of industry and academic reliability engineering. PHM consists of a variety of mathematical and computational methods used to support data-driven decision-making to increase the safety, availability, and reliability of complex engineering systems. In particular, PHM can provide crucial insight into reliability and safety design improvements for developing technologies where historical performance and failure data are limited. This is the case of hydrogen fueling and storage technologies. This work presents a high-level approach for designing data-driven PHM applications for bulk liquid hydrogen (LH 2 ) storage systems for hydrogen fueling stations. This paper addresses core aspects of the design, development, and implementation of data-driven PHM applications that can improve the reliability assessment of hydrogen components. The analysis focuses on the relationship between data availability and diagnostic/prognostic capabilities; potential challenges; and integration schemes for current risk mitigation measures. We identify potential condition-monitoring data sources for key components in an LH 2 storage system, including storage tanks, piping, and pumps. Further, we determine that the short-term goals for the implementation of data-driven models in PHM frameworks in hydrogen systems should focus on developing adequate data collection and analysis strategies, as well as exploring the effect on reliability, safety, and regulations for hydrogen systems.

08 HYDROGEN↗

Conceptual Design of a 100 MWe Modular Molten Salt Power Tower Plant

A conceptual design of a 100 MWe modular molten salt solar power tower plant has been developed which can provide capacity factors in the range of 35 to 75%. Compared to single tower plants, the modular design provides a higher degree of flexibility in achieving the desired customer's capacity factor and is obtained simply by adjusting the number of standard modules. Each module consists of a standard size heliostat field and receiver system, hence reengineering and associated unacceptable performance uncertainties due to scaling are eliminated. The modular approach with multiple towers also improves plant availability. Heliostat field components, receivers and towers are shop assembled allowing for high quality and minimal field assembly. A centralized thermal-storage system stores hot salt from the receivers, allowing nearly continuous power production, independent of solar energy collection, and improved parity with the grid. A molten salt steam generator converts the stored thermal energy into steam, which powers a steam turbine generator to produce electricity. This paper describes the conceptual design of the plant, the advantages of modularity, expected performance, pathways to cost reductions, and environmental impact.

14 SOLAR ENERGY↗

Development & Experimental Validation of a Generalized Resistance-Capacitance Model for Numerical Simulation of Phase-Change Material Embedded Heat Exchangers

Latent heat thermal energy storage (LHTES) using phase change material (PCM) has attracted increased attention as a viable solution for overcoming the mismatch between energy supply and demand for renewable energy-based systems. PCM-embedded heat exchangers (PCM-HX) have the potential to significantly improve thermal performance due to high storage capacity and low temperature variation during the phase change process. Most models for simulating LHTES heat transfer use Computational Fluid Dynamics (CFD) simulations, which have high computational costs resulting from considering the complex and time-dependent physics relevant to PCM-HXs. In this paper, a Generalized Resistance Capacitance-based Model (GRCM) was developed to predict the thermal performance of arbitrary PCM-HXs in a computationally efficient manner without compromising modeling accuracy. The GRCM is exercised for three case studies: (i) verification for a single-slabbed finned PCM-HX, (ii) verification and validation for a copper foam/paraffin composite PCM-HX, and (iii) validation for a straight tube annular finned PCM-HX. The copper foam PCM-HX uses an electric heater at the top of HX, while the other two configurations utilize water as heat transfer fluid. For the single-slabbed finned PCM-HX melting case, the mean deviation in average PCM temperature predicted by the GRCM compared to the CFD model was between 0.56 – 0.73 K, with maximum temperature deviation of 2.68 K. For the HTF outlet temperature, the validation results showed that GRCM prediction matches very well with experimental data, with mean temperature deviation of 0.24 K during melting case, while for solidification case was 0.34 K. These results showcase the GRCM’s capability for accurately reproducing the thermal characteristics of PCM-HXs with considerably lower computational effort.

42 ENGINEERING↗