Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Voltage Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Developing Antimatter Containment Technology: Modeling Charged Particle Oscillations in a Penning-Malmberg Trap

The NASA MSFC Propulsion Research Center (PRC) is conducting a research activity examining the storage of low energy antiprotons. The High Performance Antiproton Trap (HiPAT) is an electromagnetic system (Penning-Malmberg design) consisting of a 4 Tesla superconductor, a high voltage confinement electrode system, and an ultra high vacuum test section; designed with an ultimate goal of maintaining charged particles with a half-life of 18 days. Currently, this system is being experimentally evaluated using normal matter ions which are cheap to produce and relatively easy to handle and provide a good indication of overall trap behavior, with the exception of assessing annihilation losses. Computational particle-in-cell plasma modeling using the XOOPIC code is supplementing the experiments. Differing electrode voltage configurations are employed to contain charged particles, typically using flat, modified flat and harmonic potential wells. Ion cloud oscillation frequencies are obtained experimentally by amplification of signals induced on the electrodes by the particle motions. XOOPIC simulations show that for given electrode voltage configurations, the calculated charged particle oscillation frequencies are close to experimental measurements. As a two-dimensional axisymmetric code, XOOPIC cannot model azimuthal plasma variations, such as those induced by radio-frequency (RF) modulation of the central quadrupole electrode in experiments designed to enhance ion cloud containment. However, XOOPIC can model analytically varying electric potential boundary conditions and particle velocity initial conditions. Application of these conditions produces ion cloud axial and radial oscillation frequency modes of interest in achieving the goal of optimizing HiPAT for reliable containment of antiprotons.

Chakrabarti, S.↗

Environmental Testbed Development to Evaluate Power Distribution Materials in Electrified Aircraft (EA)

NASA is pursuing the development of electrified propulsion (EP) technologies to improve air transportation in terms of efficiency, affordability, and sustainability. The power requirements are expected to reach 20 megawatts for large EP commercial airliners. A key challenge is transmission and distribution of the high voltage (20 kilovolts) needed for some EP systems. This is a challenge because the risk of electrical failure in aircraft at high altitude (low pressure) due to corona discharge and other forms of partial discharge increases significantly when voltages exceed 327 V. Corona discharge is a form of partial discharge in which gaseous molecules are ionized by strong electric fields. Corona discharge leads to aging in power transmission lines. Aging is a leading cause of electrical failure in electrical insulation materials. In particular, aging from electrical, vibrational, and thermal stresses decrease the performance life of insulation materials. There are currently no test standards or equipment that can effectively age materials under high altitude, voltage and frequency conditions. This poster proposes a design for a test system including an environmental chamber that can simulate the environment of future EP systems for material and component aging tests.

Materials Test chamber Design↗

Design and Analysis of the Staggered Double Grating Slow Wave Circuit for 263 GHz Sheet Beam TWT

The complete design process of a high-frequency circuit for a 263 GHz staggered double grating, sheet beam traveling wave tube is presented in this article. Here, this device, for use in a pulsed electron paramagnetic resonance spectrometer instrument, requires >30 dB gain and a 20 GHz bandwidth centered at 263 GHz. In addition to the standard Pierce gain analysis and point by point particle in cell (PIC) simulation, a novel fast pulse response analysis technique was utilized to determine the accurate synchronization voltage and test the ``hot” feature of the high-frequency circuit. Since this new method can evaluate the entire bandwidth in a single simulation, it can significantly reduce the computational resources normally required for the conventional PIC analysis while also illustrating the potential instabilities near the band edge. Good agreement between the fast pulse response and PIC simulation results validate the accuracy of this novel method. According to the analysis results and given the manufacturing limits of nano/micro-computer numerical control (CNC) machining, an appropriate SWS, coupler, and sever designs were chosen to complement the simulated design. Finally, a prototype circuit was manufactured and cold tested to verify the design and inspect the machining tolerances.

42 ENGINEERING↗

Considerations for a Standardized Test for Potential-Induced Degradation of Crystalline Silicon PV Modules (Presentation)

Over the past decade, there have been observations of module degradation and power loss because of the stress that system voltage bias exerts. This results in part from qualification tests and standards note adequately evaluating for the durability of modules to the long-term effects of high voltage bias that they experience in fielded arrays. This talk deals with factors for consideration,progress, and information still needed for a standardized test for degradation due to system voltage stress.

14 SOLAR ENERGY↗

A flexible test facility for liquid xenon detector development

As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. Here, we describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.

Dark Matter detectors↗

Development of In-Situation Radioactivity Inspection System for Food Materials

The impacts on the ocean of releases of radionuclides from the Fukushima nuclear power plants remain unclear. Korean people worry about radioactive contamination of Japanese and Korean sea products. Radioactive contamination of processed foodstuffs, livestock, sea products, farm products imported from Japan and fishes caught in coastal oceans of Korea has become an important social issue. Recently, there are also needs of inspection system for monitoring of public meals such like school feedings of kindergarten, elementary/middle/high school and university. Radioactivity inspections of food materials have been executed manually with portable measuring instruments or at labs using their samples. But, it's very important the radioactivity inspection should be performed at the field of feeding facilities. To protect the health of people from radioactivity contained in Japanese marine products imported to Korea, a system to inspect radioactivity in real time has been developed. The system is to measure the radioactivity level of farm and marine products and public meals continuously and automatically at inspection sites of an agency checking radiation of imported foodstuffs or school. The performance test of NaI(Tl) detector was examined using the quantified Cs-137 source 10 Bq/kg, 30 Bq/kg, 50 Bq/kg, 300 Bq/kg and 900 Bq/kg at Korea Research Institute of Standards and Science(KRISS). Source was put in a box and radioactivity was measured in the middle of the box. First of all, Background was measured and calibration was performed using the Cs-137 300 Bq and Ba-133 3700 Bq for 60 minutes. After setting the background and calibration data, tests of the Cs-137 10, 30, 50, 300, 900 Bq/kg were executed for 10 minutes. A peak-shaped graph is shown at the location of 662 KeV (80∼100 channel). This is due to the gamma radiation energy with 662 KeV emitted by the Cs-137. Because through KRISS examination, the MDA (minimum detectable activity) is about 23 Bq/kg, it is reasonable Cs-137 10 Bq/kg cannot be measured. And in cases of Cs-137 300 Bq/kg and 900 Bq/kg, there are some peak movement on the graph. It can be adjusted by controlling gain or high voltage. The examination was identified through the performance test (Cs-137 10, 30, 50, 300, 900 Bq/kg) at KRISS. In order to increase the measurement efficiency of Cs-137 and the system performance, database will be built up based on radioactivity measurement results from 10 to 300 Bq/kg with the unit 10. Thus, Cs-137 concentration of food materials can be identified below the maximum permissible concentration of 100 Bq/kg on a basis of the spectrum characteristic of Cs-137. Also, anxiety about radioactive contamination of foods after the Fukushima nuclear accident will be eased and trust of the radioactive inspection is expected definitely. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Autonomous Inspection of Electrical Transmission Structures with Airborne UV Sensors and Automated Air Traffic Management

This report details test and measurement flights to demonstrate autonomous UAV (Unmanned Aerial Vehicle) inspection of high-voltage electrical transmission structures. A UAV built with commercial, off-the-shelf hardware and software, supplemented with custom sensors and logging software, measured ultraviolet (UV) emissions from a test generator placed on a low-altitude substation and a medium-altitude switching tower. Since corona discharge precedes catastrophic electrical faults on high-voltage structures, detection and geolocation of ultraviolet emissions is needed to develop a UAV-based self-diagnosing power grid. Signal readings from an onboard ultraviolet sensor were validated during flight with a commercial corona camera. Geolocation was accomplished with onboard GPS; the UAV position was logged to a local ground station and transmitted in real time to a NASA server for tracking in the national airspace. The method has practicality and relevance but not adequacy; either improved UAV position determination technology or increased sensor range is needed to enable broad deployment of this method.

Moore, Andrew J.↗

Tantalum capacitor behavior under fast transient overvoltages

Tantalum capacitors were tested to determine failure time when subjected to short-duration, high-voltage surges caused by lightning strikes. Lightning is of concern to NASA because of possible damage to critical spacecraft circuits. The test was designed to determine the minimum time for tantalum capacitor failure and the amount of overvoltage a capacitor could survive, without permanent damage, in 100 microseconds. All tested exhibited good recovery from the transient one-shot pulses with no failure at any voltage, forward or reverse, in less than 25 microseconds.

Zill, J. A.↗

Low cost space power generation

The success of this study has given a method of fabricating durable copolymer films without size limitations. Previously, only compression molded samples were durable enough to generate electrical energy. The strengthened specimens are very long lived materials. The lifetime was enhanced at least a factor of 1,300 in full pyroelectric conversion cycle experiments compared with extruded, non-strengthened film. The new techniques proved so successful that the lifetime of the resultant copolymer samples was not fully characterized. The lifetime of these new materials is so long that accelerated tests were devised to probe their durability. After a total of more than 67 million high voltage electrical cycles at 100 C, the electrical properties of a copolymer sample remained stable. The test was terminated without any detectable degradation to allow for other experiments. One must be cautious in extrapolating to power cycle performance, but 67 million electrical cycles correspond to 2 years of pyroelectric cycling at 1 Hz. In another series of experiments at reduced temperature and electrical stress, a specimen survived over one-third of a billion electrical cycles during nearly three months of continuous testing. The radiation-limited lifetimes of the copolymer were shown to range from several years to millions of years for most earth orbits. Thus, the pyroelectric copolymer has become a strong candidate for serious consideration for future spacecraft power supplies.

Olsen, Randall B.↗

Testing of the Piezo-Actuators at High Dynamic Rate Operational Conditions

Reliability of the piezo-actuators deployed in SRF cavity tuners operated at high dynamic voltage range rate conditions can lead to a significant impact on the overall performance of the SRF linacs. We tested at FNAL piezoactuators P-844K075 that were developed at Physik Instrumente (PI) for LCLSII project. Although these actuators were developed for a CW linac we tested them at high dynamic rate inside a cryogenic/insulated vacuum environment. Results of the tests will be presented. Different modes of the piezo-actuators failure will be discussed.

43 PARTICLE ACCELERATORS↗

Additional extensions to the NASCAP computer code, volume 1

Extensions and revisions to a computer code that comprehensively analyzes problems of spacecraft charging (NASCAP) are documented. Using a fully three dimensional approach, it can accurately predict spacecraft potentials under a variety of conditions. Among the extensions are a multiple electron/ion gun test tank capability, and the ability to model anisotropic and time dependent space environments. Also documented are a greatly extended MATCHG program and the preliminary version of NASCAP/LEO. The interactive MATCHG code was developed into an extremely powerful tool for the study of material-environment interactions. The NASCAP/LEO, a three dimensional code to study current collection under conditions of high voltages and short Debye lengths, was distributed for preliminary testing.

Mandell, M. J.↗

Electrostatic Precipitation in Nearly Pure Gaseous Nitrogen

Electrostatic precipitation was performed in a nearly pure gaseous nitrogen system as a possible remedy for black dust contaminant from high pressure 6000 psi lines at the NASA Kennedy Space Center. The results of a prototype electrostatic precipitator that was built and tested using nitrogen gas at standard atmospheric pressures is presented. High voltage pulsed waveforms are generated using a rotating spark gap system at 30 Hz. A unique dust delivery system utilizing the Venturi effect was devised that supplies a given amount of dust per unit time for testing purposes.

Buhler, Charles↗

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge and Neutralizer Cathodes

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for both discharge and neutralizer cathodes. Discharge keeper erosion was found to be significantly reduced from what was observed in the NEXT 2 kh wear test and NSTAR Extended Life Test, providing adequate protection of vital cathode components throughout the test with ample lifetime remaining. The area of the discharge cathode orifice plate that was exposed by the keeper orifice exhibited net erosion, leading to cathode plate material building up in the cathode-keeper gap and causing a thermally-induced electrical short observed during the test. Significant erosion of the neutralizer cathode orifice was also found and is believed to be the root cause of an observed loss in flow margin. Deposition within the neutralizer keeper orifice as well as on the downstream surface was thicker than expected, potentially resulting in a facility-induced impact on the measured flow margin from plume mode. Neutralizer keeper wall erosion on the beam side was found to be significantly lower compared to the NEXT 2 kh wear test, likely due to the reduction in beam extraction diameter of the ion optics that resulted in decreased ion impingement. Results from the post-test inspection have led to some minor thruster design improvements.

Electric Propulsion↗

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge and Neutralizer Cathodes

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in April 2014 after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This presentation presents relevant results of the post-test inspection for both discharge and neutralizer cathodes.

Lifetime↗

Post-test Inspection of NASA’s Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge and Neutralizer Cathodes

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 h of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for both discharge and neutralizer cathodes. Discharge keeper erosion was found to be significantly reduced from what was observed in the NEXT 2 kh wear test and NSTAR Extended Life Test, providing adequate protection of vital cathode components throughout the test with ample lifetime remaining. The area of the discharge cathode orifice plate that was exposed by the keeper orifice exhibited net erosion, leading to cathode plate material building up in the cathode-keeper gap and causing a thermally-induced electrical short observed during the test. Significant erosion of the neutralizer cathode orifice was also found and is believed to be the root cause of an observed loss in flow margin. Deposition within the neutralizer keeper orifice as well as on the downstream surface was thicker than expected, potentially resulting in a facility-induced impact on the measured flow margin from plume mode. Neutralizer keeper wall erosion on the beam side was found to be significantly lower compared to the NEXT 2 kh wear test, likely due to the reduction in beam extraction diameter of the ion optics that resulted in decreased ion impingement. Results from the post-test inspection have led to some minor thruster design improvements.

Ion engine↗

The performance of cable braids and terminations to lightning induced transients

The latest specification detailing the test waveforms for indirect lightning transients as applied to aircraft wiring systems specify very high voltages and currents. Although considerable data exists for measuring cable screen leakage using such methods as surface transfer impedance and bulk cable injection, there is little data on the likely core transient level that is likely to be induced from these threats. In particular, the new Waveform 5 at very high current levels (10 kA) is reputed to cause severe cable damage. A range of representative cables were made with various screen termination techniques and screening levels. These were tested first to determine their relative screening performance and then they were subjected to lightning transient testing to all the specified waveforms. Core voltages were measured for each test. Tests were also performed on bundles with fewer wires to determine the failure criteria with Waveform 5 and these tests also include flat conductor cables. The test showed that correctly terminated cable bundles performed well in all the tests and would provide a high level of protection to the electronic systems. The use of overbraides, provided the individual screens are well terminated, appears to be unnecessary.

Crofts, David↗