Search NASA⌕ Search

SEARCH · Search NASA

Results for “High precision control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Low Cost High Efficiency Magnetrons for Accelerator Applications

High efficiency, low cost RF sources are required for proton, ion, and muon accelerators. These sources must be compact and provide precise control of the output power and phase. Currently only large, expensive klystrons can provide this performance. Calabazas Creek Research Inc. proposes to develop a phase locked magnetron-based system that has phase and amplitude control via a low power amplifier. The system uses phase modulation to control the RF power. The efficiency can exceed 80% and the cost is expected to be less than $3/Watt, significantly lower than other high power amplifiers. CCR originally proposed to develop a magnetron with a grid for control of phase and amplitude. Detailed simulations showed that this was not a promising approach. The grid was found to be viable only in magnetrons with low duty cycle, and amplitude control was demonstrated; but the grid was found to be not effective for phase locking. Attention was turned to a concept from Fermilab, which is very promising for both amplitude and phase control and does not require a grid. CCR will develop an RF system providing phase and amplitude control of a 100 kW peak, 10 kW average 1.3 GHz magnetron. Procedures and techniques will be applicable to design of systems at other frequencies and power levels. The program will include development of the magnetron and locking electronics. The system will be tested at Fermilab. Commercial Applications and Other Benefits Magnetrons can provide high levels of RF power at very high efficiency at low cost. As oscillators, however, their applications are limited. Magnetrons with more precise control of the output power and control of the phase could find wide application in accelerators and colliders. They would also provide improved performance for high resolution radar.

43 PARTICLE ACCELERATORS↗

Understanding Structure–Property Relationships of MoO 3 -Promoted Rh Catalysts for Syngas Conversion to Alcohols

Rh-based catalysts have shown promise for the direct conversion of syngas to higher oxygenates. Although improvements in higher oxygenate yield have been achieved by combining Rh with metal oxide promoters, details of the structure of the promoted catalyst and the role of the promoter in enhancing catalytic performance are not well understood. In this work, we show that MoO 3 -promoted Rh nanoparticles form a novel catalyst structure in which Mo substitutes into the Rh surface, leading to both a 66-fold increase in turnover frequency and an enhancement in oxygenate yield. By applying a combination of atomically controlled synthesis, in situ characterization, and theoretical calculations, we gain an understanding of the promoter-Rh interactions that govern catalytic performance for MoO 3 -promoted Rh. We use atomic layer deposition to modify Rh nanoparticles with monolayer-precise amounts of MoO 3 , with a high degree of control over the structure of the catalyst. Through in situ X-ray absorption spectroscopy, we find that the atomic structure of the catalytic surface under reaction conditions consists of Mo–OH species substituted into the surface of the Rh nanoparticles. Furthermore, using density functional theory calculations, we identify two roles of MoO 3 : first, the presence of Mo–OH in the catalyst surface enhances CO dissociation and also stabilizes a methanol synthesis pathway not present in the unpromoted catalyst; and second, hydrogen spillover from Mo–OH sites to adsorbed species on the Rh surface enhances hydrogenation rates of reaction intermediates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase-sensitive optical coherence tomography-based vibrometry using a highly phase-stable akinetic swept laser source

Phase-sensitive Optical Coherence Tomography (PhOCT) is an emerging tool for in vivo investigation of the vibratory function of the intact middle and inner ear. PhOCT is able to resolve micron scale tissue morphology in three dimensions as well as measure picometer scale motion at each spatial position. Most PhOCT systems to date have relied upon the phase stability offered by spectrometer detection. On the other hand swept laser source based PhOCT offers a number of advantages including balanced detection, long imaging depths, and high imaging speeds. Unfortunately the inherent phase instability of traditional swept laser sources has necessitated complex user developed hardware/software solutions to restore phase sensitivity. Here we present recent results using a prototype swept laser that overcomes these issues. The akinetic swept laser is electronically tuned and precisely controls sweeps without any mechanical movement, which results in high phase stability. We have developed an optical fiber based PhOCT system around the akinetic laser source that had a 1550 nm center wavelength and a sweep rate of 140 kHz. The stability of the system was measured to be 4.4 pm with a calibrated reflector, thus demonstrating near shot noise limited performance. Using this PhOCT system, we have acquired structural and vibratory measurements of the middle ear in a mouse model, post mortem. The quality of the results suggest that the akinetic laser source is a superior laser source for PhOCT with many advantages that greatly reduces the required complexity of the imaging system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detailed study of quark-hadron duality in spin structure functions of the proton and neutron

Background: The response of hadrons, the bound states of the strong force (QCD), to external probes can be described in two different, complementary frameworks: as direct interactions with their fundamental constituents, quarks and gluons, or alternatively as elastic or inelastic coherent scattering that leaves the hadrons in their ground state or in one of their excited (resonance) states. The former picture emerges most clearly in hard processes with high momentum transfer, where the hadron response can be described by the perturbative expansion of QCD, while at lower energy and momentum transfers, the resonant excitations of the hadrons dominate the cross section. The overlap region between these two pictures, where both yield similar predictions, is referred to as quark-hadron duality and has been extensively studied in reactions involving unpolarized hadrons. Some limited information on this phenomenon also exists for polarized protons, deuterons, and 3 He nuclei, but not yet for neutrons. Purpose: In this paper, we present comprehensive and detailed results on the correspondence between the extrapolated deep inelastic structure function g 1 of both the proton and the neutron with the same quantity measured in the nucleon resonance region. Thanks to the fine binning and high precision of our data, and using a well-controlled perturbative QCD (pQCD) fit for the partonic prediction, we can make quantitative statements about the kinematic range of applicability of both local duality and global duality. Method: We use the most updated QCD global analysis results at high x from the Jefferson Lab Angular Momentum Collaboration to extrapolate the spin structure function g 1 into the nucleon resonance region and then integrate over various intervals in the scaling variable x. We compare the results with the large data set collected in the quark-hadron transition region by the CLAS Collaboration, including, for the first time, deconvoluted neutron data, integrated over the same intervals. We present this comparison as a function of the momentum transfer Q 2 . Results: We find that, depending on the integration interval and the minimum momentum transfer chosen, a clear transition to quark-hadron duality can be observed in both nucleon species. Furthermore, we show, for the first time, the approach to scaling behavior for g 1 measured in the resonance region at sufficiently high momentum transfer. Conclusions: Here, our results can be used to quantify the deviations from the applicability of pQCD for data taken at moderate energies and can help with extraction of quark distribution functions from such data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Orientation-Controlled Large-Area Epitaxial PbI 2 Thin Films with Tunable Optical Properties

Lead iodide (PbI 2 ) as a layered material has emerged as an excellent candidate for optoelectronics in the visible and ultraviolet regime. Micrometer-sized flakes synthesized by mechanical exfoliation from bulk crystals or by physical vapor deposition have shown a plethora of applications from low-threshold lasing at room temperature to high-performance photodetectors with large responsivity and faster response. However, large-area centimeter-sized growth of epitaxial thin films of PbI 2 with well-controlled orientation has been challenging. Additionally, the nature of grain boundaries in epitaxial thin films of PbI 2 remains elusive. Here, we use mica as a model substrate to unravel the growth mechanism of large-area epitaxial PbI 2 thin films. The partial growth leading to uncoalesced domains reveals the existence of inversion domain boundaries in epitaxial PbI 2 thin films on mica. Combining the experimental results with first-principles calculations, we also develop an understanding of the thermodynamic and kinetic factors that govern the growth mechanism, which paves the way for the synthesis of high-quality large-area PbI 2 on other substrates and heterostructures of PbI 2 on single-crystalline graphene. Here, the ability to reproducibly synthesize high-quality large-area thin films with precise control over orientation and tunable optical properties could open up unique and hitherto unavailable opportunities for the use of PbI 2 and its heterostructures in optoelectronics, twistronics, substrate engineering, and strain engineering.

2D materials↗

High Precision Tune and Coupling Feedback and Beam Transfer Function Measurements in RHIC

Precision measurement and control of the betatron tunes and betatron coupling in the Relativistic Heavy Ion Collider (RHIC) are required for establishing and maintaining both good operating conditions and, particularly during the ramp to high beam energies, high proton beam polarization. While the proof-of-principle for simultaneous tune and coupling feedback was successfully demonstrated earlier, routine application of these systems has only become possible recently. Following numerous modifications for improved measurement resolution and feedback control, the time required to establish full-energy beams with the betatron tunes and coupling regulated by feedback was reduced from several weeks to a few hours. A summary of these improvements, select measurements benefitting from the improved resolution and a review of system performance are the subject of this report.

43 PARTICLE ACCELERATORS↗

The Design and Performance of Low Cost Haptic Interfaces to Control Precision Nuclear Robotic System - 18351

Nuclear decommissioning environments are challenging and hazardous, typically involving high temperatures, pressures and extreme radiation. Robotic devices are commonly used to complete tasks within challenging environments, which would otherwise pose a risk to human health, however remotely operating robots without full three-dimensional vision is challenging, and operators of robotic systems require extensive training to enable precise navigation through three-dimensional environments using multiple two-dimensional views for feedback. This project explores the possibility of using a human arm as a master device for controlling a variety of low-cost slave robots, with the aim of reducing training times whilst providing a cheaper, more intuitive control system. Virtual Reality (VR) and haptics are used as an aid for navigation of the remote environment, whilst also providing a digital twin for the operator to enable real-time feedback from the slave robot. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electrically Injected UV-Visible Nanowire Lasers

There is strong interest in minimizing the volume of lasers to enable ultracompact, low-power, coherent light sources. Nanowires represent an ideal candidate for such nanolasers as stand-alone optical cavities and gain media, and optically pumped nanowire lasing has been demonstrated in several semiconductor systems. Electrically injected nanowire lasers are needed to realize actual working devices but have been elusive due to limitations of current methods to address the requirement for nanowire device heterostructures with high material quality, controlled doping and geometry, low optical loss, and efficient carrier injection. In this project we proposed to demonstrate electrically injected single nanowire lasers emitting in the important UV to visible wavelengths. Our approach to simultaneously address these challenges is based on high quality III-nitride nanowire device heterostructures with precisely controlled geometries and strong gain and mode confinement to minimize lasing thresholds, enabled by a unique top-down nanowire fabrication technique.

42 ENGINEERING↗

The management of tumor motions in the stereotactic irradiation to lung cancer under the use of Abches to control active breathing

Purpose: Breathing control is crucial to ensuring the accuracy of stereotactic irradiation for lung cancer. This study monitored respiration in patients with inoperable nonsmall-cell lung cancer using a respiration-monitoring apparatus, Abches, and investigated the reproducibility of tumor position in these patients. Methods: Subjects comprised 32 patients with nonsmall-cell lung cancer who were administered stereotactic radiotherapy under breath-holding conditions monitored by Abches. Computed tomography (CT) was performed under breath-holding conditions using Abches (Abches scan) for treatment planning. A free-breathing scan was performed to determine the range of tumor motions in a given position. After the free-breathing scan, Abches scan was repeated and the tumor position thus defined was taken as the intrafraction tumor position. Abches scan was also performed just before treatment, and the tumor position thus defined was taken as the interfraction tumor position. To calculate the errors, tumor positions were compared based on Abches scan for the initial treatment plan. The error in tumor position was measured using the BrainSCAN treatment-planning device, then compared for each lung lobe. Results: Displacements in tumor position were calculated in three dimensions (i.e., superior-inferior (S-I), left-right (L-R), and anterior-posterior (A-P) dimensions) and recorded as absolute values. For the whole lung, average intrafraction tumor displacement was 1.1 mm (L-R), 1.9 mm (A-P), and 2.0 mm (S-I); the average interfraction tumor displacement was 1.1 mm (L-R), 2.1 mm (A-P), and 2.0 mm (S-I); and the average free-breathing tumor displacement was 2.3 mm (L-R), 3.5 mm (A-P), and 7.9 mm (S-I). The difference between using Abches and free breathing could be reduced from approximately 20 mm at the maximum to approximately 3 mm in the S-I direction for both intrafraction and interfraction positions in the lower lobe. In addition, maximum intrafraction tumor displacement with the use of Abches was 4.5 mm (S-I) in the lingular segment. These results suggest that use of the Abches system can reduce deviations in tumor position to levels below those achieved under free breathing, irrespective of the tumor location. Conclusions: Respiratory control with high accuracy and reproducibility is required for high-precision radiotherapy of inoperable nonsmall-cell lung cancer and was achieved using Abches in this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Containerless measurements on liquids at high temperatures

The application of containerless techniques for measurements of the thermophysical properties of high temperature liquids is reviewed. Recent results obtained in the materials research laboratories at Intersonics are also presented. Work to measure high temperature liquid properties is motivated by both the need for reliable property data for modeling of industrial processes involving molten materials and generation of data form basic modeling of materials behavior. The motivation for this work and examples of variations in thermophysical property values from the literature are presented. The variations may be attributed to changes in the specimen properties caused by chemical changes in the specimen and/or to measurement errors. The two methods used to achieve containerless conditions were aeroacoustic levitation and electromagnetic levitation. Their qualities are presented. The accompanying slides show the layout of levitation equipment and present examples of levitated metallic and ceramic specimens. Containerless techniques provide a high degree of control over specimen chemistry, nucleation and allow precise control of liquid composition to be achieved. Effects of minor additions can thus be measured in a systematic way. Operation in reduced gravity enables enhanced control of liquid motion which can allow measurement of liquid transport properties. Examples of nucleation control, the thermodynamics of oxide contamination removal, and control of the chromium content of liquid aluminum oxide by high temperature containerless processes are presented. The feasibility of measuring temperature, emissivity, liquidus temperature, enthalpy, surface tension, density, viscosity, and thermal diffusivity are discussed in the final section of the paper.

Weber, Richard↗

Ion-Gated Gas Separation through Porous Graphene

Porous graphene holds great promise as a one-atom-thin, high-permeance membrane for gas separation, but to precisely control the pore size down to 3–5 Å proves challenging. Here we propose an ion-gated graphene membrane comprising a monolayer of ionic liquid-coated porous graphene to dynamically modulate the pore size to achieve selective gas separation. This approach enables the otherwise nonselective large pores on the order of 1 nm in size to be selective for gases whose diameters range from 3 to 4 Å. We show from molecular dynamics simulations that CO 2 , N 2 , and CH 4 all can permeate through a 6 Å nanopore in graphene without any selectivity. But when a monolayer of [emim][BF 4 ] ionic liquid (IL) is deposited on the porous graphene, CO 2 has much higher permeance than the other two gases. We find that the anion dynamically modulates the pore size by hovering above the pore and provides affinity for CO 2 , while the larger cation (which cannot go through the pore) holds the anion in place via electrostatic attraction. This composite membrane is especially promising for CO 2 /CH 4 separation, yielding a CO 2 /CH 4 selectivity of about 42 and CO 2 permeance of ~10 5 GPU (gas permeation unit). We further demonstrate that selectivity and permeance can be tuned by the anion size, pore size, and IL thickness. The present work points toward a promising direction of using the atom-thin ionic liquid/porous graphene hybrid membrane for high-permeance, selective gas separation that allows a greater flexibility in substrate pore size control.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-throughput Accurate-wavelength Lens-based Visible Spectrometera

A scanning visible spectrometer has been prototyped to complement fixed-wavelength transmission grating spectrometers for charge exchange recombination spectroscopy. Fast f/1.8 200 mm commercial lenses are used with a large 2160 mm-1 grating for high throughput. A stepping-motor controlled sine drive positions the grating, which is mounted on a precision rotary table. A high-resolution optical encoder on the grating stage allows the grating angle to be measured with an absolute accuracy of 0.075 arcsec, corresponding to a wavelength error ≤ 0.005 Å. At this precision, changes in grating groove density due to thermal expansion and variations in the refractive index of air are important. An automated calibration procedure determines all relevant spectrometer parameters to high accuracy. Changes in bulk grating temperature, atmospheric temperature and pressure are monitored between the time of calibration and the time of measurement to insure a persistent wavelength calibration

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precision control of multiple quantum cascade lasers for calibration systems

We present a precision, 1-A, digitally interfaced current controller for quantum cascade lasers, with demonstrated temperature coefficients for continuous and 40-kHz full-depth square-wave modulated operation, of 1–2 ppm/ °C and 15 ppm/ °C, respectively. High precision digital to analog converters (DACs) together with an ultra-precision voltage reference produce highly stable, precision voltages, which are selected by a multiplexer (MUX) chip to set output currents via a linear current regulator. The controller is operated in conjunction with a power multiplexing unit, allowing one of three lasers to be driven by the controller, while ensuring protection of controller and all lasers during operation, standby, and switching. Simple ASCII commands sent over a USB connection to a microprocessor located in the current controller operate both the controller (via the DACs and MUX chip) and the power multiplexer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin Transparency Method for High Precision Experiments with Polarized Beams

The spin transparency method is a technique for efficient and flexible control of the beam polarizationin a synchrotron. It can be implemented in a figure-8 collider, a racetrack with two identical Siberiansnakes, as well as in a conventional ring at an energy corresponding to an integer spin resonance.Weak-field magnetic insertions called Spin Navigators provide polarization stabilization and manip-ulation including spin flipping. By compensating the spin effects of imperfections, a real synchrotroncan be turned into an effectively ideal ring from the spin dynamics point of view thus enabling funda-mental ultra-high precision experiments such as search for Electric Dipole Moment and Dark Matter.We discuss the possibility of applying the spin transparency mode at ultra-high energies

Filatov, Yury N.↗

Exo-C: A Dedicated Probe-scale Space Mission for Coronagraphic Imaging and Spectroscopy of Exoplanetary Systems

"Exo-C", the Exoplanet Coronagraph, is a concept for a dedicated probe-scale (< $1B) space mission optimized for direct imaging of exoplanetary systems. It was the product of a detailed mission study carried in 2013-2015 under the sponsorship of the NASA Astrophysics Division. Exo-C was designed to be capable of spectrally characterizing 1-2 dozen nearby exoplanets in reflected visible light, discovering previously undetected planets, and imaging structure in hundreds of circumstellar disks. It would obtain unique science results on planets down to super-Earth size and serve as a technology pathfinder toward an eventual flagship-class mission to find and characterize habitable Earth-like exoplanets. Key design elements are an unobscured telescope aperture, an internal coronagraph with deformable mirrors for precise wavefront control, and an orbit and observatory design chosen for high thermal stability. ExoC’s telescope aperture, orbit, mission lifetime, and spacecraft bus are all comparable to those of the highly successful Kepler mission. Much of the needed technology development (precision pointing, wavefront sensing and correction, high contrast integral field spectroscopy, detector flight readiness) has been advanced by the WFIRST Coronagraph Instrument (CGI) project over the past several years. Mission performance, mass, power, and cost estimates have also benefited from detailed work by the WFIRST CGI team. A Cost and Technical Evaluation (CATE) was performed in 2015 by the Aerospace Corporation. Today Exo-C is a backup option to WFIRST CGI. It could nominally be implemented within seven years from project start. This white paper summarizes the study final report, with updates on performance and technical readiness as of spring 2019.

Karl R. Stapelfeldt↗

Thickness dependence of piezo-bimorph adaptive mirror bending

A new generation of adaptive x-ray optics (AXO) is being installed on high-coherent-flux x-ray beamlines worldwide to correct and control the optical wavefront with sub-nm precision. These ultra-smooth mirrors achieve high reflectivities at glancing angles of incidence and can be hundreds of mm long. One type of adaptive x-ray mirror relies on piezoelectric ceramic strips which are segmented into channels and actuated to induce local, longitudinal bending, generating one-dimensional shape changes in the mirror substrate. A recently described mirror model uses a three-layer geometry with parallel actuators on the front and back surfaces of a thicker mirror substrate. By analogy to a solved problem in the thermal actuation of a tri-metal strip, we show that the achievable bending radius varies approximately as the square of the substrate thickness. We provide an analytic solution and simulate bending using a finite-element model.

47 OTHER INSTRUMENTATION↗

Operating characteristics of a 10 kW xenon ion propulsion module

Performance testing of a two-engine functional model xenon ion propulsion module is described. Use of highly modified J-series 30 cm ion engines reconfigured for xenon propellant, a computer controlled operating system, and precise flow control system are shown to result in very reliable ion module operation at high input power levels. Ion engine operation at a nominal 4.0 ampere beam current and 30.0 volt discharge gives a specific impulse of 3310 sec, a total engine efficiency of 64.3 percent, and a thrust-to-power ratio of 39.5 mN/kW at an input power level of 5.10 kW. These modified J series ion engines are shown to be capable of throttling over an 8:1 range from a power level of 5.48 kW at 3285 sec to a power level of 0.70 kW at 1856 sec. In addition, complete ion engine performance mapping of important system level parameters such as thrust, specific impulse, efficiency and thrust-to-power ratio are presented.

Aston, Graeme↗