Search NASA⌕ Search

SEARCH · Search NASA

Results for “High resolution data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

MARVEL Analysis of the Measured High-resolution Rovibronic Spectra of {sup 48}Ti{sup 16}O

Accurate, experimental rovibronic energy levels, with associated labels and uncertainties, are reported for 11 low-lying electronic states of the diatomic {sup 48}Ti{sup 16}O molecule, determined using the Marvel (Measured Active Rotational-Vibrational Energy Levels) algorithm. All levels are based on lines corresponding to critically reviewed and validated high-resolution experimental spectra taken from 24 literature sources. The transition data are in the 2–22,160 cm{sup −1} region. Out of the 49,679 measured transitions, 43,885 are triplet–triplet, 5710 are singlet–singlet, and 84 are triplet–singlet transitions. A careful analysis of the resulting experimental spectroscopic network (SN) allows 48,590 transitions to be validated. The transitions determine 93 vibrational band origins of {sup 48}Ti{sup 16}O, including 71 triplet and 22 singlet ones. There are 276 (73) triplet–triplet (singlet–singlet) band-heads derived from Marvel experimental energies, 123(38) of which have never been assigned in low- or high-resolution experiments. The highest J value, where J stands for the total angular momentum, for which an energy level is validated is 163. The number of experimentally derived triplet and singlet {sup 48}Ti{sup 16}O rovibrational energy levels is 8682 and 1882, respectively. The lists of validated lines and levels for {sup 48}Ti{sup 16}O are deposited in the supporting information to this paper.

79 ASTRONOMY AND ASTROPHYSICS↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗

VisIO: enabling interactive visualization of ultra-scale, time-series data via high-bandwidth distributed I/O systems

Petascale simulations compute at resolutions ranging into billions of cells and write terabytes of data for visualization and analysis. Interactive visuaUzation of this time series is a desired step before starting a new run. The I/O subsystem and associated network often are a significant impediment to interactive visualization of time-varying data; as they are not configured or provisioned to provide necessary I/O read rates. In this paper, we propose a new I/O library for visualization applications: VisIO. Visualization applications commonly use N-to-N reads within their parallel enabled readers which provides an incentive for a shared-nothing approach to I/O, similar to other data-intensive approaches such as Hadoop. However, unlike other data-intensive applications, visualization requires: (1) interactive performance for large data volumes, (2) compatibility with MPI and POSIX file system semantics for compatibility with existing infrastructure, and (3) use of existing file formats and their stipulated data partitioning rules. VisIO, provides a mechanism for using a non-POSIX distributed file system to provide linear scaling of 110 bandwidth. In addition, we introduce a novel scheduling algorithm that helps to co-locate visualization processes on nodes with the requested data. Testing using VisIO integrated into Para View was conducted using the Hadoop Distributed File System (HDFS) on TACC's Longhorn cluster. A representative dataset, VPIC, across 128 nodes showed a 64.4% read performance improvement compared to the provided Lustre installation. Also tested, was a dataset representing a global ocean salinity simulation that showed a 51.4% improvement in read performance over Lustre when using our VisIO system. VisIO, provides powerful high-performance I/O services to visualization applications, allowing for interactive performance with ultra-scale, time-series data.

97 MATHEMATICS AND COMPUTING↗

The thermodynamic properties of hydrated γ-Al{sub 2}O{sub 3} nanoparticles

In this paper we report a combined calorimetric and inelastic neutron scattering (INS) study of hydrated γ-Al{sub 2}O{sub 3} (γ-alumina) nanoparticles. These complementary techniques have enabled a comprehensive evaluation of the thermodynamic properties of this technological and industrially important metal oxide to be achieved. The isobaric heat capacity (C{sub p}) data presented herein provide further critical insights into the much-debated chemical composition of γ-alumina nanoparticles. Furthermore, the isochoric heat capacity (C{sub v}) of the surface water, which is so essential to the stability of all metal-oxides at the nanoscale, has been extracted from the high-resolution INS data and differs significantly from that of ice‑Ih due to the dominating influence of strong surface-water interactions. This study also encompassed the analysis of four γ-alumina samples with differing pore diameters [4.5 (1), 13.8 (2), 17.9 (3), and 27.2 nm (4)], and the results obtained allow us to unambiguously conclude that the water content and pore size have no influence on the thermodynamic behaviour of hydrated γ-alumina nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heterogeneous Visualization: A Call for Empirically Driven Technology Advancement and Adoption; Preprint

Our ability to generate data from simulations and experimental platforms is generally outpacing our ability to analyze those data efficiently and effectively. There are a growing number and variety of possible visualization display modalities, from commodity head-mounted displays to large-scale immersive environments, from desktop and touch displays to high-resolution display walls. Many of these visualization technologies and visual environments are rapidly evolving and could revolutionize analysis for certain classes of complex scientific and engineering data. However, the choice of what technology or combination of technologies to use has historically been largely ad hoc and lacks a carefully validated understanding of how to best utilize different visualization technologies to advance the science. To maximize the impact of our data and analyses, it is imperative that we use the most effective visualization environments for the analysis task at hand.

heterogeneous visualization↗

Feasibility of the detection of trace elements in particulate matter using online High-Resolution Aerosol Mass Spectrometry

The feasibility of using an online thermal-desorption electron-ionization high-resolution aerosol mass spectrometer (AMS) for the detection of particulate trace elements was investigated analyzing data from Mexico City obtained during the MILAGRO 2006 field campaign, where relatively high concentrations of trace elements have been reported. This potential application is of interest due to the real-time data provided by the AMS, its high sensitivity and time resolution, and the widespread availability and use of this instrument. High resolution mass spectral analysis, isotopic ratios, and ratios of different ions containing the same elements are used to constrain the chemical identity of the measured ions. The detection of Cu, Zn, As, Se, Sn, and Sb is reported. There was no convincing evidence for the detection of other trace elements commonly reported in PM. The elements detected tend to be those with lower melting and boiling points, as expected given the use of a vaporizer at 600oC in this instrument. Operation of the AMS vaporizer at higher temperatures is likely to improve trace element detection. The detection limit is estimated at approximately 0.3 ng m-3 for 5-min of data averaging. Concentration time series obtained from the AMS data were compared to concentration records determined from offline analysis of particle samples from the same times and locations by ICP (PM2.5) and PIXE (PM1.1 and PM0.3). The degree of correlation and agreement between the three instruments (AMS, ICP, and PIXE) varied depending on the element. The AMS shows promise for real-time detection of some trace elements, although additional work including laboratory calibrations with different chemical forms of these elements are needed to further develop this technique and to understand the differences with the ambient data from the other techniques. The trace elements peaked in the morning as expected for primary sources, and the many detected plumes suggest the presence of multiple point sources, probably industrial, in Mexico City which are variable in time and space, in agreement with previous studies.

99 GENERAL AND MISCELLANEOUS↗

Quantifying and relating land-surface and subsurface variability in permafrost environments using lidar and surface geophsical datasets

The complexity of permafrost dynamics and its critical impact on climate feedbacks warrant continued development of advanced high-latitude terrestrial ecosystem characterization and monitoring approaches. In this study, we explore the value of remote sensing and surface geophysical data for characterizing land surface and subsurface properties and their linkages in an Alaskan Coastal Plain ecosystem. We base our study on data collected at the end of the 2011 growing season in the Barrow Environmental Observatory, where a nested suite of measurements were collected within a polygon-dominated region including: surface ground penetrating radar, electromagnetic, and electrical resistance tomography data; thaw depth, soil temperature and moisture content, soil texture, soil carbon and nitrogen content, and major and trace cations. Previously-collected lidar data were also available for the study. Analysis of the datasets, individually and in combination, revealed the utility of the methods for characterizing critical land-surface and subsurface properties and associated spatial zonation. Lidar analysis was performed to extract geomorphic metrics (such as slope, curvature, and directed distance of polygons), which potentially indicate drainage potential and permafrost deformation state. Cluster analysis of these lidar-obtained attributes suggested that the land surface can be grouped into three spatially coherent zones, each having a dominant geomorphic expression including: a high centered polygon zone, a low centered polygon zone and a transitional zone. Comparison of the geophysical attributes from radar, electrical resistance tomography, and electromagnetic data with point measurements suggests that the surface geophysical data can provide very high-resolution information about subsurface properties that affect ecosystem feedbacks to climate, such as thaw depth and moisture content. Cluster analysis suggested that the geophysical attributes also varied spatially in a systematic way, suggesting the presence of three laterally distinct subsurface zones. Analysis of zone-based subsurface point measurements suggests that the geophysically-defined zones have unique distributions of hydrological, thermal, and geochemical properties and that the subsurface (geophysically-based) and land-surface (lidar-based) zonation is consistent. Although the close linkage between land surface (polygonal geomorphology) and subsurface (active layer) variability revealed through our study is not surprising, to our knowledge this is the first study to document such relationships using high resolution and non-invasive approaches. This study suggests the potential of using coincident lidar and surface geophysical measurements to quantify land surface and subsurface properties (respectively) and their linkages, which are likely to play a role in terrestrial ecosystem evolution and feedbacks to climate. These findings open the way for future research focused on using combined geophysical and remote sensing datasets to estimate subsurface and land-surface properties in high resolution and over large regions as is needed for process understanding and numerical model initialization in high latitude terrestrial ecosystems.

Climate↗

High-resolution ultrahigh-pressure long column reversed-phase liquid chromatography for top-down proteomics

We report development of an approach providing high-resolution RPLC of proteins and its utility for mass spectrometry-based top-down proteomics. A chromatographic peak capacity of ~450 was achieved for proteins and large polypeptides having MWs up to 43 kDa in the context of proteomics applications. RPLC column lengths from 20 to 200 cm, particle sizes from 1.5 to 5 m, bonding alkyl chains from C1 to C2, C4, C8, and C18, and particle surface structures that spanned porous, superficially porous (porous shell, core-shell), and nonporous were investigated at pressures up to14K psi. Column length was found as the most important factor for >20 kDa proteins in gradient RPLC, and shortening column length degraded RPLC resolution and sensitivity regardless of the size and surface structure of the packing particles used. The alkyl chains bonded to the silica particle surface significantly affected the RPLC recovery and efficiency, and short alkyl C1-C4 phases provided higher sensitivity and resolution than C8 and C18 phases. Long gradient separations (e.g., >10 hours) with long columns (e.g., 100 cm) were particularly effective in conjunction with use of high accuracy mass spectrometers (e.g., the Orbitrap Elite) for top-down proteomics with improved proteoform coverage by allowing multiple HCD, CID, and ETD dissociation modes. It was also found that HCD produced small fragments useful for proteoform identification, while low energy CID and ETD often complemented HCD by providing large fragments.

columns and stationary phases↗

Ambidextrous Helical Nanotubes from Self-Assembly of Designed Helical Hairpin Motifs

Tandem repeat proteins exhibit native designability and represent potentially useful scaffolds for the construction of synthetic biomimetic assemblies. We have designed two synthetic peptides, HEAT R1 and LRV M3Δ1, based on the consensus sequences of single repeats of thermophilic HEAT (PBS HEAT) and Leucine- Rich Variant (LRV) structural motifs, respectively. Self-assembly of the peptides afforded high aspect-ratio helical helical nanotubes. Cryo-electron microscopy with direct electron detection was employed to analyze the structures of the solvated filaments. Three dimensional reconstructions from the cryo-EM maps led to atomic models for the HEAT R1 and LRV M3Δ1 filaments at resolutions of 6.0 Å and 4.4 Å, respectively. Surprisingly, despite sequence similarity at the lateral packing interface, HEAT R1 and LRV M3Δ1 filaments adopt the opposite helical hand and differ significantly in helical geometry, while retaining a local conformation similar to previously characterized repeat proteins of the same class. The differences in the two filaments could be rationalized on the basis of differences in cohesive interactions at the lateral and axial interfaces. These structural data reinforce previous observations regarding the structural plasticity of helical protein assemblies and the need for high resolution structural analysis. Despite these observations, the native designability of tandem repeat proteins offers the opportunity to engineer novel helical nanotubes. Furthermore, the resultant nanotubes have independently addressable and chemically distinguishable interior and exterior surfaces that would facilitate applications in selective recognition, transport, and release.

59 BASIC BIOLOGICAL SCIENCES↗

A MONTE CARLO ANALYSIS OF THE VELOCITY DISPERSION OF THE GLOBULAR CLUSTER PALOMAR 14

We present the results of a detailed analysis of the projected velocity dispersion of the globular cluster Palomar 14 performed using recent high-resolution spectroscopic data and extensive Monte Carlo simulations. The comparison between the data and a set of dynamical models (differing in fraction of binaries, degree of anisotropy, mass-to-light ratio M/L, cluster orbit, and theory of gravity) shows that the observed velocity dispersion of this stellar system is well reproduced by Newtonian models with a fraction of binaries f{sub b} < 30% and an M/L compatible with the predictions of stellar evolution models. Instead, models computed with a large fraction of binaries systematically overestimate the cluster velocity dispersion. We also show that, across the parameter space sampled by our simulations, models based on the modified Newtonian dynamics theory can be reconciled with observations only assuming values of M/L lower than those predicted by stellar evolution models under standard assumptions.

79 ASTRONOMY AND ASTROPHYSICS↗

THE BURST CLUSTER: DARK MATTER IN A CLUSTER MERGER ASSOCIATED WITH THE SHORT GAMMA-RAY BURST, GRB 050509B

We have identified a merging galaxy cluster with evidence of two distinct subclusters. The X-ray and optical data suggest that the subclusters are presently moving away from each other after closest approach. This cluster merger was discovered from observations of the first well-localized short-duration gamma-ray burst (GRB), GRB 050509B. The Swift/Burst Alert Telescope error position of the source is coincident with a cluster of galaxies ZwCl 1234.0+02916, while the subsequent Swift/X-Ray Telescope localization of the X-ray afterglow found the GRB coincident with 2MASX J12361286+2858580, a giant red elliptical galaxy in the cluster. Deep multi-epoch optical images were obtained in this field to constrain the evolution of the GRB afterglow, including a total of 27,480 s exposure in the F814W band with Hubble Space Telescope Advanced Camera for Surveys, among the deepest imaging ever obtained toward a known galaxy cluster in a single passband. We perform a weak gravitational lensing analysis based on these data, including mapping of the total mass distribution of the merger system with high spatial resolution. When combined with Chandra X-ray Observatory Advanced CCD Imaging Spectrometer and Swift/XRT observations, we are able to investigate the dynamical state of the merger to better understand the nature of the dark matter component. Our weak gravitational lensing measurements reveal a separation of the X-ray centroid of the western subcluster from the center of the mass and galaxy light distributions, which is somewhat similar to that of the famous 'Bullet cluster', and we conclude that this 'Burst cluster' adds another candidate to the previously known merger systems for determining the nature of dark matter, as well as for studying the environment of a short GRB. Finally, we discuss potential connections between the cluster dynamical state and/or matter composition, and compact object mergers, which is currently the leading model for the origin of short GRBs. We also present our results from a weak-lensing survey based on archival Very Large Telescope images in the areas of five other short GRBs, which do not provide any firm detections of mass concentrations representative of rich clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

3D Imaging of Microbial Biofilms: Integration of Synchrotron Imaging and an Interactive Visualization Interface

Understanding the interactions of structured communities known as “biofilms” and other complex matrixes is possible through the X-ray micro tomography imaging of the biofilms. Feature detection and image processing for this type of data focuses on efficiently identifying and segmenting biofilms and bacteria in the datasets. The datasets are very large and often require manual interventions due to low contrast between objects and high noise levels. Thus new software is required for the effectual interpretation and analysis of the data. This work specifies the evolution and application of the ability to analyze and visualize high resolution X-ray micro tomography datasets.

Biofilm Viewer↗

Integration of New Technology Considering the Trade-Offs Between Operational Benefits and Risks: A Case Study of Dynamic Line Rating

Electric grid operators are adept at handling complexity and uncertainty. However, with increasing introduction of renewable generation, distributed energy resources, and more frequent severe weather events, operators will experience new workload and challenging decision scenarios. Here, this paper quantifies risks and benefits from an operator's perspective of introducing weather based forecast Dynamic Line Ratings (DLR) using variable wind conditions in addition to ambient temperature to relieve transmission congestion and facilitating more offshore wind (OSW). A concept of operations (CONOPS) applied to a forecast DLR implementation and its integration with OSW is defined. A method for evaluating tradeoffs of derating to make the rating more conservative but decreasing the benefit was developed and applied to a case study for two existing overhead transmission lines on Long Island, New York. The CONOPS uses historical day-ahead and hour-ahead High Resolution Rapid Refresh weather forecasts and weather station data to support planning and real-time operations. The analysis determines the risk of downgrades in real-time operational rating compared to the forecast and quantifies the frequency and severity of last-minute downgrades. The risk is compared against the benefits in increased capacity to provide insights on the additional amount of uncertainty DLR and OSW will add to the operator's workload.

17 WIND ENERGY↗

Continuous Reliability Enhancement for Wind (CREW) Database: Wind Plant Reliability Benchmark

To benchmark the current U.S. wind turbine fleet reliability performance and identify the major contributors to component-level failures and other downtime events, the Department of Energy (DOE) funded the development of the Continuous Reliability Enhancement for Wind (CREW) database by Sandia National Laboratories. This report is the second annual Wind Plant Reliability Benchmark, to publically report on CREW findings for the entire wind industry. The CREW database uses both high resolution Supervisory Control and Data Acquisition (SCADA) data from operating plants and Strategic Power Systems’ (SPS) ORAPWind® (Operational Reliability Analysis Program for Wind) data, which consists of downtime and reserve event records and daily summaries of Generating, Unavailable, and Reserve time for each turbine. Together, these data are used as inputs into CREW’s reliability modeling. The results presented here include: the primary CREW Benchmark statistics (operational availability, utilization, capacity factor, mean time between events, and mean downtime); time accounting from an availability perspective; time accounting in terms of the combination of wind speed and generation levels; power curve analysis; and top system and component contributors to unavailability.

Peters, Valerie A.↗

OSIRIS User's Manual, v. 1.0

The On-Site Inspection RadioIsotopic Spectroscopy (OSIRIS) system is a gamma-ray spectroscopy instrument for on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). [1] OSIRIS identifies fission-product isotopes with a high-resolution gamma-ray spectrometer. The spectrometer is controlled by a ruggedized notebook computer running data acquisition and data analysis software customized for CTBT on-site inspections. This manual explains OSIRIS preparation and setup for operation; startup procedures, including energy-calibration of the spectrometer; spectral measurements and spectral analyses; and shutdown procedures.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Dynamics retrieval from stochastically weighted incomplete data by low-pass spectral analysis

Time-resolved serial femtosecond crystallography (TR-SFX) provides access to protein dynamics on sub-picosecond timescales, and with atomic resolution. Due to the nature of the experiment, these datasets are often highly incomplete and the measured diffracted intensities are affected by partiality. To tackle these issues, one established procedure is that of splitting the data into time bins, and averaging the multiple measurements of equivalent reflections within each bin. This binning and averaging often involve a loss of information. Here, we propose an alternative approach, which we call low-pass spectral analysis (LPSA). In this method, the data are projected onto the subspace defined by a set of trigonometric functions, with frequencies up to a certain cutoff. This approach attenuates undesirable high-frequency features and facilitates retrieving the underlying dynamics. A time-lagged embedding step can be included prior to subspace projection to improve the stability of the results with respect to the parameters involved. Subsequent modal decomposition allows to produce a low-rank description of the system's evolution. Using a synthetic time-evolving model with incomplete and partial observations, we analyze the LPSA results in terms of quality of the retrieved signal, as a function of the parameters involved. We compare the performance of LPSA to that of a range of other sophisticated data analysis techniques. We show that LPSA allows to achieve excellent dynamics reconstruction at modest computational cost. Finally, we demonstrate the superiority of dynamics retrieval by LPSA compared to time binning and merging, which is, to date, the most commonly used method to extract dynamical information from TR-SFX data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Limitations and Benefits of ARISA Intra-genomic Diversity Fingerprinting

Monitoring diversity changes and contamination in mixed cultures and simplemicrocosms is challenged by fast community structure dynamics, and the need for means allowing fast, cost-efficient and accurate identification of microorganisms at high phylogenetic resolution. The method we explored is a variant of Automated rRNA Intergenic Spacer Analysis based on Intra-Genomic Diversity Fingerprinting (ARISAIGDF), and identifies phylotypes with multiple 16S–23S rRNA gene Intergenic Transcribed Spacers. We verified the effect of PCR conditions (annealing temperature, duration of final extension, number of cycles, group-specific primers and formamide) on ARISA-IGD fingerprints of 44 strains of Shewanella.We present a digitization algorithmand data analysis procedures needed to determine confidence in strain identification. Though using stringent PCR conditions and group-specific primers allow reasonably accurate identification of strains with three ARISA-IGD amplicons within the 82–1000 bp size range, ARISA-IGDF is best for phylotypes with ≥4 unambiguously different amplicons. This method allows monitoring the occurrence of culturable microbes and can be implemented in applications requiring high phylogenetic resolution, reproducibility, low cost and high throughput such as identifying contamination and monitoring the evolution of diversity in mixed cultures and low diversity microcosms and periodic screening of small microbial culture libraries.

59 BASIC BIOLOGICAL SCIENCES↗