Search NASA⌕ Search

SEARCH · Search NASA

Results for “Humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Global Evaluation of Terrestrial Near-Surface Air Temperature and Specific Humidity Retrievals from the Atmospheric Infrared Sounder (AIRS)

Global observations of near-surface air temperature and specific humidity over land are needed for a variety of applications, including to constrain global estimates of evapotranspiration (ET). Spaceborne hyperspectral observations, such as those from NASA’s Atmospheric Infrared Sounder (AIRS) mission, show promise for meeting this need, yet there are surprisingly few validation studies of AIRS near-surface atmospheric state retrievals. In this study, we use triple collocation to validate AIRS Level 3 retrievals of near-surface atmospheric state over land using twelve years of gridded station observations and two reanalyses. Deseasonalized AIRS retrievals correlate well with deseasonalized ground observations outside the tropics, but correlate less well in the tropics. Lower temporal sensitivity near the surface in the tropics contributes to the lower correlation for near-surface air temperature and is consistent with known physics of the tropical atmosphere, in which temperatures outside the boundary layer (which dominate the AIRS retrieval signal) are poorly correlated with those near the surface. Retrievals in the tropics may also be more susceptible to errors in cloud-clearing algorithms, and to uncertainty in surface emissivity. Since ET is greatest in the tropics, and tropical measurement networks are particularly sparse, this work motivates new approaches for measuring ET in the tropics.

Evapotranspiration↗

Evaluating Observational Constraints on Intermodel Spread in Cloud, Temperature, and Humidity Feedbacks

Uncertainty in climate feedbacks is the primary source of the spread in projected surface temperature responses to anthropogenic forcing. Cloud feedback persistently appears as the main source of disagreement in future projections while the combined lapse-rate plus water vapor (LR+WV) feedback is a smaller (30%), but non-trivial source of uncertainty in climate sensitivity. Here we attempt to observationally constrain the feedbacks in an effort to reduce the irintermodel uncertainties. The observed interannual variation provides a useful constraint on the long-term cloud feedback, as evidenced by the consistency of global-mean values and regional contributions to the intermodal spread on both interannual and long-term timescales. However, interannual variability does not serve to constrain the long-term LR+WV feedback spread, which we find is dominated by the varying tropical relative humidity (RH) response to interhemispheric warming differences under clear-sky conditions and the RH-fixed LR feedback under all-sky conditions

radiative feedbacks↗

Quantifying and Characterizing Striping of Microwave Humidity Sounder with Observation and Simulation

Striping has been observed in the MetOp-A Microwave Humidity Sounder (MHS) data since its degradation in November 2018. However, accurate striping quantification and characterization remain challenging due to the large scene dynamics observed at W/G bands of MHS. Here we have developed a set of novel algorithms for striping quantification, decomposition, characterization, and simulation. Our algorithm extracts striping from the warm-load and cold-space scenes that are relatively stable. We break down the striping into two parts of thermal and 1/f noise and quantify their absolute magnitude and relative ratio. We found a significant increase in striping at 157 GHz that has more than quadrupled by October 2019 relative to its normal level. Regardless of the degradation, the ratio of thermal and 1/f noise remains the same. Our simulation reproduces all the characteristics of striping against observation. It is shown that 1/f noise generates sharp, non-periodic stripes, while thermal noise also generates stripes but with smoother band features. The latter is due to the periodic calibration that has a chopping effect. The striping percentage, defined as the ratio of 1/f to total noise, shows no dependence on the scene temperature. Striping is pronounced not only in 157 GHz but also in 89 and190 GHz with the striping percentage over 50%, while lower in183 GHz of 20%. The results provide insights for quantifying and understanding striping. Our algorithm can be applied to other radiometers and to simulate striping for evaluating its impact in data assimilation and science products.

John Xun Yang↗

Fabrication and Testing of a Novel Ceramic-Based Additively Manufactured Humidity Sensor

A material capable of detecting minute changes in ambient humidity via a change in its electrical properties is critical to enabling the success of vapor-sensitive components on Earth and abroad. Manufacturing of these hydrophilic materials currently follows an extensive process of heat treating focused on removing the solvent and organic vehicle. This research aims to reduce the complexity of manufacturing these novel sensors by eliminating the high-temperature (>850 °C) processing stages. A method based on printing a polymer embedded with hydrophilic nanoparticles is accomplished through selected additively manufactured methods. This research branches into the elimination of physical spare parts with the ability to print highly sensitive in-situ sensors, reducing the environmental footprint in space-critical environments like the International Space Station (ISS).

sensor↗

Xplo-SA9T: Optimization of Sorbent Technology With Existing and New Amine Variants for Carbon Dioxide Removal and Humidity Control

Scrubbing of the spacesuit air stream to control humidity and regulate carbon dioxide (CO 2 ) relies on amine-loaded resins, colloquially known as sorbents. The efficacy of Rapid Cycle Amine technology relies on the propensity of nitrogens toward adsorption of CO 2 while simultaneously offering regenerative properties under vacuum or positive pressure. The commonly utilized sorbent, SA9T, was recreated and evaluated further to increase stability and serve as a benchmark comparison for newly synthesized amine sorbent technologies. Ongoing storage studies with eight different environments will allow the development of applicable storage protocols and provide insight into possible ammonia generation pathways. Attempts to alleviate the known issues with SA9T included the alteration of the primary amine (tetraethylenepentamine), the choice of resin, and the particle size distribution. In-house CO 2 breakthrough experiments were conducted using a specialized apparatus that can simulate spacesuit conditions, offering high-quality triplicate capacity analysis affording direct comparison to known adsorbents in the literature. Thermo-Desorption Gas Chromatography Mass Spectrometry studies on the synthesized materials revealed any reagent or solvent offgassing while Nuclear Magnetic Resonance spectroscopy tracked the stability of the bound amine. Scanning Electron Microscope images of sieved materials provided a more accurate size interpretation facilitating synthetic design and pressure drop elimination. All efficient sorbents were synthesized to a commercial batch scale subsequent to evaluation including Xplo-SA9T.

John R Tidwell↗

Variable Refrigerant Flow Performance: Humidity and Efficiency in Multifamily Buildings in New York, NY

Variable refrigerant flow (VRF) systems have become common in large multifamily buildings. The upfront cost is appealing to developers, as a single system can provide all heating and cooling. VRF systems also use no on-site fossil fuels which can help avoid greenhouse gas emissions. However, there have been very few data on how VRF systems actually perform in buildings. Researchers monitored three new, multifamily buildings with a focus on VRF system sizing, humidity control, and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Variation of Ice Microphysical Properties With Temperature and Humidity at Tops of Convective Clouds

A better understanding of the many interacting processes governing the evaluation of ice in natural clouds is required to improve the representation of ice clouds in global circulation models. Recent studies suggest a dominant role of vapor growth processes in determining the temperature dependence of cloud top ice sizes and shapes. Using airborne cloud remote sensing along with reanalysis data, here we show that observed cloud top ice effective radii and estimated normalized growth rates at cloud top highly correlate with an approximately linear relationship, which is consistent with a conceptual model also presented. Furthermore, significant differences in crystal shape characteristics and scattering asymmetry parameters are found between sub- and super-saturated cloud tops over ocean, although not over land. These results provide valuable observational targets for studying ice formation and evolution processes using models, while also helping interpretation of satellite observations of ice microphysical properties at cloud tops.

ice↗

Observations of airflow around a supertall curved building and its impact on temperature and humidity in Houston's urban center

Characterization of realistically shaped skyscrapers embedded in non-uniform neighbourhoods experiencing intricate weather patterns remains inadequately investigated. Aiming to close this gap, the Center for Multiscale Applied Sensing team deployed its mobile observatory in the street canyons around the curved Wells Fargo Plaza skyscraper in downtown Houston, TX. Three deployments allowed airflow observations under different inflow wind and thermodynamic stability conditions. Doppler lidar measurements reveal that when inflow hits the curved wall of the skyscraper, perpendicular canyons experience similar vortex configurations creating two windward and two leeward circulations. Windsond measurements support that buoyancy within the deep street canyons can generate thermal updrafts as strong as 2 m s -1 which is sufficient to overturn the mechanical downwash under gentle wind conditions. Canyons experiencing venting during the daytime were observed to be more thermodynamically stable at night while thermodynamically stable canyons during the day were observed to be more thermodynamically unstable at night owing to the accumulation of heat near street-level. Fourier decomposition of the vertical velocity measurements shows that in all cases flow exhibited high Reynolds numbers and was composed of turbulent eddies of predominantly 6 and 15 min periods. Here, this observational dataset provides insights to assess wind load, pedestrian comfort, urban air mobility, and natural ventilation and may be used as a benchmark for numerical model and wind tunnel studies attempting to represent realistically complex urban conditions.

54 ENVIRONMENTAL SCIENCES↗

Energy impact of heating electrification in mid-rise multifamily buildings in mixed-humid climates

Decarbonizing the electric grid in conjunction with electrifying residential heating is a critical step to combat climate change. Heating in multifamily buildings with the existing natural gas-fired central boiler is a complex process that not only leads to overheating in some apartment units but also results in energy waste and high gas bills. In this study, we consider a multifamily building in New York City, USA, to evaluate the performance of five different heating systems, which represent a step-by-step transition from the conventional to a fully electrified heating system, and determine their impact on the site energy consumption and source CO 2 emissions. Results indicate that overheating in a multifamily building can raise the indoor temperature by as much as 8°C above comfortable limits. Transitioning from conventional steam radiators to cold climate heat pumps can reduce annual site heating energy by up to 70% and source CO 2 emissions by up to 21%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗