Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Interaction of low-energy implanted atomic H with slow and fast diffusing metallic impurities in Si

The interaction of hydrogen, injected into silicon using low-energy ion bombardment, with slow (Ti and V) and fast (Cr and Au) diffusing impurities was investigated. It was found that this H ion bombardment of the Si surface was effective in reducing the electrically active concentration of only the fast diffusing impurities. The results are explained by damage enhanced diffusivity and surface gettering of the fast diffusing impurities.

Singh, R.↗

1.54 micron Emission from Erbium implanted GaN for Photonic Applications

The development of efficient and compact light sources operating at 1.54 micron is of enormous importance for the advancement of new optical communication systems. Erbium (1%) doped fiber amplifiers (EDFA's) or semiconductor lasers are currently being employed as near infrared light sources. Both devices, however, have inherent limitations due to their mode of operation. EDFA's employ an elaborate optical pumping scheme, whereas diode lasers have a strongly temperature dependent lasing wavelength. Novel light emitters based on erbium doped III-V semiconductors could overcome these limitations. Er doped semiconductors combine the convenience of electrical excitation with the excellent luminescence properties of Er(3+) ions. Electrically pumped, compact, and temperature stable optoelectronic devices are envisioned from this new class of luminescent materials. In this paper we discuss the potential of Er doped GaN for optoelectronic applications based on temperature dependent photoluminescence excitation studies.

Thaik, Myo↗

Polymer Coats Leads on Implantable Medical Device

Langley Research Center s Soluble Imide (LaRC-SI) was discovered by accident. While researching resins and adhesives for advanced composites for high-speed aircraft, Robert Bryant, a Langley engineer, noticed that one of the polymers he was working with did not behave as predicted. After putting the compound through a two-stage controlled chemical reaction, expecting it to precipitate as a powder after the second stage, he was surprised to see that the compound remained soluble. This novel characteristic ended up making this polymer a very significant finding, eventually leading Bryant and his team to win several NASA technology awards, and an "R&D 100" award. The unique feature of this compound is the way that it lends itself to easy processing. Most polyimides (members of a group of remarkably strong and incredibly heat- and chemical-resistant polymers) require complex curing cycles before they are usable. LaRC-SI remains soluble in its final form, so no further chemical processing is required to produce final materials, like thin films and varnishes. Since producing LaRC-SI does not require complex manufacturing techniques, it has been processed into useful forms for a variety of applications, including mechanical parts, magnetic components, ceramics, adhesives, composites, flexible circuits, multilayer printed circuits, and coatings on fiber optics, wires, and metals. Bryant s team was, at the time, heavily involved with the aircraft polymer project and could not afford to further develop the polymer resin. Believing it was worth further exploration, though, he developed a plan for funding development and submitted it to Langley s chief scientist, who endorsed the experimentation. Bryant then left the high-speed civil transport project to develop LaRC-SI. The result is an extremely tough, lightweight thermoplastic that is not only solvent-resistant, but also has the ability to withstand temperature ranges from cryogenic levels to above 200 C. The thermoplastic s unique characteristics lend it to many commercial applications; uses that Bryant believed would ultimately benefit industry and the Nation. "LaRC-SI," he explains, "is a product created in a government laboratory, funded with money from the tax-paying public. What we discovered helps further the economic competitiveness of the United States, and it was our goal to initiate the technology transfer process to ensure that our work benefited the widest range of people." Several NASA centers, including Langley, have explored methods for using LaRC-SI in a number of applications from radiation shielding and as an adhesive to uses involving replacement of conventional rigid circuit boards. In the commercial realm, LaRC-SI can now be found in several commercial products, including the thin-layer composite unimorph ferroelectric driver and sensor (THUNDER) piezoelectric actuator, another "R&D 100" award winner (Spinoff 2005).

Source record↗

Decay of Reactivity Induced by Simulated Solar Wind Implantation of a Forsteritic Olivine

In returning humans to the Moon, the Lunar Airborne Dust Toxicity Advisory Group (LADTAG) must address many problems faced by the original Apollo astronauts. Major among these is control of the fine dust (<20 microns) that makes up approx.20 wt% portion of the lunar surface. This ubiquitous, clinging, sharp, abrasive, glassy dust caused a plethora of problems with seals, abrasion, and coatings, in addition to possible health problems, including lunar dust hayfever. The lifetime of reactive sites on the surfaces of irradiated lunar dust grains is of interest to those studying human health because of the free radicals and toxic compounds that may be formed and may not passivate quickly when exposed to habitat/spacecraft air.

Kuhlman, K.R.↗

Hand-Held Units for Short-Range Wireless Biotelemetry

Special-purpose hand-held radiotransceiver units have been proposed as means of short-range radio powering and interrogation of surgically implanted microelectromechanical sensors and actuators. These units are based partly on the same principles as those of the units described in "Printed Multi- Turn Loop Antennas for RF Biotelemetry" (LEW-17879-1), NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 48. Like the previously reported units, these units would make it unnecessary to have wire connections between the implanted devices and the external equipment used to activate and interrogate them. Like a unit of the previously reported type, a unit of the type now proposed would include a printed-circuit antenna on a dielectric substrate. The antenna circuitry would include integrated surface-mount inductors for impedance tuning. Circuits for processing the signals transmitted and received by the antenna would be included on the substrate. During operation, the unit would be positioned near (but not in electrical contact with) a human subject, in proximity to a microelectromechanical sensor or actuator that has been surgically implanted in the subject. It has been demonstrated that significant electromagnetic coupling with an implanted device could be established at a distance of as much as 4 in. (.10 cm). During operation in the interrogation mode, the antenna of the unit would receive a radio telemetry signal transmitted by the surgically implanted device. The antenna substrate would have dimensions of approximately 3.25 by 3.75 inches (approximately 8.3 by 9.5 cm). The substrate would have a thickness of the order of 30 mils (of the order of a somewhat less than a millimeter). The substrate would be made of low-radiofrequency- loss dielectric material that could be, for example, fused quartz, alumina, or any of a number of commercially available radio-frequency dielectric composite materials. The antenna conductors would typically be made of copper or a combination of chromium and gold. The choice of metal and the thickness of the metal layer(s) would depend on the choice of substrate material. For example, on a quartz or alumina substrate, one would typically use a layer of chromium 150 A thick and a layer of gold 2 m thick. The proposed units and the implanted devices that they would interrogate or activate would be inherently safe to use. They would operate at low radiated-power levels for short interrogation times (typically, milliseconds). Hence, there would be little local heating of tissues surrounding the implanted devices and little absorption of radio energy by such sensitive body parts as the eyes and the brain. Because the implanted devices would not depend on battery power and would be activated only during short interrogation intervals and would otherwise be in the goff h state most of the time, the useful lifetimes of the implanted devices would be greater than those of comparable battery-powered implanted devices. The compactness of the hand-held transceiver units would facilitate transport and storage and would facilitate self-diagnosis by patients able to handle the units while away from medical facilities.

Miranda, Felix A.↗

Unified Approach to the Biomechanics of Dental Implantology

The human need for safe and effective dental implants is well-recognized. Although many implant designs have been tested and are in use today, a large number have resulted in clinical failure. These failures appear to be due to biomechanical effects, as well as biocompatibility and surgical factors. A unified approach is proposed using multidisciplinary systems technology, for the study of the biomechanical interactions between dental implants and host tissues. The approach progresses from biomechanical modeling and analysis, supported by experimental investigations, through implant design development, clinical verification, and education of the dental practitioner. The result of the biomechanical modeling, analysis, and experimental phases would be the development of scientific design criteria for implants. Implant designs meeting these criteria would be generated, fabricated, and tested in animals. After design acceptance, these implants would be tested in humans, using efficient and safe surgical and restorative procedures. Finally, educational media and instructional courses would be developed for training dental practitioners in the use of the resulting implants.

Grenoble, D. E.↗

Development of pulsed processes for the manufacture of solar cells

Low-energy ion implantation processes for the automated production of silicon solar cells were investigated. Phosphorus ions at an energy of 10 keV and dose of 2 x 10 to the 15th power/sq cm were implanted in silicon solar cells to produce junctions, while boron ions at 25 keV and 5 x 10 to the 15th power were implanted in the cells to produce effective back surface fields. An ion implantation facility with a beam current up to 4 mA and a production throughput of 300 wafers per hour was designed and installed. A design was prepared for a 100 mA, automated implanter with a production capacity of 100 MW sub e/sq cm per year. Two process sequences were developed which employ ion implantation and furnace or pulse annealing. A computer program was used to determine costs for junction formation by ion implantation and various furnace annealing cycles to demonstrate cost effectiveness of these methods.

Minnucci, J. A.↗