Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT ERROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Assessing the Impact of Observations in a Multi-Year Reanalysis

Operational and quasi-operational weather prediction centers have been routinely assessing the contribution from various observing systems to reducing errors in short-range forecasts for a number of years now. The original technique, Forecast Sensitivity Observation Impact (FSOI), involves definition of a forecast error measure and evaluation of sensitivities with respect to changes in the observing system that require adjoint operators of both the underlying tangent linear model and corresponding analysis technique. The present work applies FSOI to Reanalysis and aims at providing an expanded view of the contribution of various observing systems over nearly 40 years of assimilation. Specifically, this study uses MERRA-2 given that its supporting software includes all ingredients necessary to calculate FSOI. Part of this work shows how the quality of forecasts improves over the course of the reanalysis, and examines forecast sensitivities relevant to FSOI. The assessment here finds, for example, that: conventional observations are a major player in reducing forecast error throughout the 40 years of reanalysis, even when their volume reduces from 45% in the earlier periods to about 5% in the modern era; satellite radiances, especially microwave instruments are major contributors to error reduction from the early single platform TIROS-N days to the current multi-platform scenario; infrared instruments play a secondary role to microwave but are significant still, with the peculiar result of fractional impacts contribution from modern hyperspectral instruments being roughly similar to those from early infrared instruments. The dependence of results on the chosen error measure is emphasized throughout.

Fabio L R Diniz↗

Mariner Jupiter/Saturn infrared instrument study

The Mariner Jupiter/Saturn infrared instrumentation conceptual design study was conducted to determine the physical and operational characteristics of the instruments needed to satisfy the experiment science requirements. The design of the instruments is based on using as many proven concepts as possible. Many design features are taken from current developments such as the Mariner, Pioneer 10, Viking Orbiter radiometers, and Nimbus D spectrometer. Calibration techniques and error analysis for the instrument system are discussed.

Source record↗

A new skin friction balance and selected measurements

A new skin friction balance with moving belt has been developed for measurement of the surface shear stress component in the direction of belt motion. The device is described in this paper with typical measurement results. This instrument is symmetric in design with small moving mass negligible internal friction. It is 3.8 cm high, 3.8 cm long and 2.1 cm wide, with the sensing surface 0.7 cm wide and 1.5 cm long, and it can be made in various sizes. The unique design of this instrument has reduced some of the errors associated with conventional floating-element balances. The instrument can use various sensing systems and the output signal is a linear function of the wall shear stress. Measurements show good agreement with data obtained by the floating element balances and flat plate prediction techniques. Dynamic measurements have been made in a limited range. The overall uncertainty of measurement is estimated to be +/- 2 percent.

Vakili, A. D.↗

Development of a Fabry-Perot Interferometer for Ultra-Precise Measurements of Column CO2

A passive Fabry-Perot based instrument is described for detecting column CO2 through absorption measurements at 1.58 microns . In this design, solar flux reaches the instrument platform and is directed through two channels. In the first channel, transmittance fi5nges from a Fabry-Perot interferometer are aligned with CO2 absorption lines so that absorption due to CO2 is primarily detected. The second channel encompasses the same frequency region as the first, but is comparatively more sensitive to changes in the solar flux than absorption due to CO2. The ratio of these channels is sensitive to changes in the total CO2 column, but not to changes in solar flux. This inexpensive instrument will offer high precision measurements (error 4%) in a compact package. Design of this instrument and preliminary ground-based measurements of column CO2 are presented here as well as strategies for deployment on aircraft and satellite platforms.

Wilson, Emily L.↗

Wall shear stress measurements using a new transducer

A new instrument has been developed for direct measurement of wall shear stress. This instrument is simple and symmetric in design with small moving mass and no internal friction. Features employed in the design of this instrument eliminate most of the difficulties associated with the traditional floating element balances. Vibration problems associated with the floating element skin friction balances have been found to be minimized by the design features and optional damping provided. The unique design of this instrument eliminates or reduces the errors associated with conventional floating-element devices: such as errors due to gaps, pressure gradient, acceleration, heat transfer and temperature change. The instrument is equipped with various sensing systems and the output signal is a linear function of the wall shear stress. Measurement made in three different tunnels show good agreement with theory and data obtained by the floating element devices.

Vakili, A. D.↗

Correlative Stratospheric Ozone Measurements with the Airborne UV DIAL System during TOTE/VOTE

The airborne UV differential absorption lidar (DIAL) system participated in the Tropical Ozone Transport Experiment/Vortex Ozone Transport Experiment (TOTE/VOTE) in late 1995/early 1996. This mission afforded the opportunity to compare the DIAL system's stratospheric ozone measuring capability with other remote-sensing instruments through correlative measurements over a latitude range from the tropics to the Arctic. These instruments included ground-based DIAL and space-based stratospheric instruments: HALOE; MLS; and SAGE II. The ozone profiles generally agreed within random error estimates for the various instruments in the middle of the profiles in the tropics, but regions of significant systematic differences, especially near or below the tropopause or at the higher altitudes were also found. The comparisons strongly suggest that the airborne UV DIAL system can play a valuable role as a mobile lower-stratospheric ozone validation instrument.

Grant, William B.↗

Comparison of mesospheric ozone measurements using the LRIR and UVMCS satellite instruments

A comparison between mesospheric ozone profiles determined by two radically different satellite-borne instruments is presented for the period of July to November, 1975. The Limb Radiance Inversion Radiometer measured 9.6-micron O3 emission, while the Ultraviolet Multiple Channel Spectrometer measured the atmospheric attenuation of solar ultraviolet radiation during passage of the OSO-8 satellite across the terminator. Only nine near coincident measurements were found. The individual instruments have estimated precision errors of + or - 10 to 15 percent. Agreement between ozone values as measured by the two techniques for specific cases varies between 10 and 20 percent. The statistical correlation is positive and significant at all altitudes where both instruments had reasonable signal-to-noise ratio. A maximum correlation of 0.76 occurred at 0.3 mb (about 59 km).

Millier, F.↗

Error in Dasibi flight measurements of atmospheric ozone due to instrument wall-loss

Theory suggests that in laminar flow the percent loss of a trace constituent to the walls of a measuring instrument varies as P to the -2/3, where P is the total gas pressure. Preliminary laboratory ozone wall-loss measurements confirm this P to the -2/3 dependence. Accurate assessment of wall-loss is thus of particular importance for those balloon-borne instruments utilizing laminar flow at ambient pressure, since the ambient pressure decreases by a factor of 350 during ascent to 40 km. Measurements and extrapolations made for a Dasibi ozone monitor modified for balloon flight indicate that the wall-loss error at 40 km was between 6 and 30 percent and that the wall-loss error in the derived total ozone column-content for the region from the surface to 40 km altitude was between 2 and 10 percent. At 1000 mb, turbulence caused an order of magnitude increase in the Dasibi wall-loss.

Ainsworth, J. E.↗

Extracting ocean surface information from altimeter returns - The deconvolution method

An evaluation of the deconvolution method for estimating ocean surface parameters from ocean altimeter waveforms is presented. It is shown that this method presents a fast, accurate way of determining the ocean surface parameters from noisy altimeter data. Three parameters may be estimated by using this method, including the altimeter-height error, the ocean-surface standard deviation, and the ocean-surface skewness. By means of a Monte Carlo experiment, an 'optimum' deconvolution algorithm and the accuracies with which the above parameters may be estimated using this algorithm are determined. Then the influence of instrument effects, such as errors in calibration and pointing-angle estimation, on the estimated parameters is examined. Finally, the deconvolution algorithm is used to estimate height and ocean-surface parameters from Seasat data.

Rodriguez, Ernesto↗

Wavefront-Error Performance Characterization for the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) Science Instruments

The science instruments (SIs) comprising the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) were tested in three cryogenic-vacuum test campaigns in the NASA Goddard Space Flight Center (GSFC)'s Space Environment Simulator (SES). In this paper, we describe the results of optical wavefront-error performance characterization of the SIs. The wavefront error is determined using image-based wavefront sensing (also known as phase retrieval), and the primary data used by this process are focus sweeps, a series of images recorded by the instrument under test in its as-used configuration, in which the focal plane is systematically changed from one image to the next. High-precision determination of the wavefront error also requires several sources of secondary data, including 1) spectrum, apodization, and wavefront-error characterization of the optical ground-support equipment (OGSE) illumination module, called the OTE Simulator (OSIM), 2) plate scale measurements made using a Pseudo-Nonredundant Mask (PNRM), and 3) pupil geometry predictions as a function of SI and field point, which are complicated because of a tricontagon-shaped outer perimeter and small holes that appear in the exit pupil due to the way that different light sources are injected into the optical path by the OGSE. One set of wavefront-error tests, for the coronagraphic channel of the Near-Infrared Camera (NIRCam) Longwave instruments, was performed using data from transverse translation diversity sweeps instead of focus sweeps, in which a sub-aperture is translated andor rotated across the exit pupil of the system.Several optical-performance requirements that were verified during this ISIM-level testing are levied on the uncertainties of various wavefront-error-related quantities rather than on the wavefront errors themselves. This paper also describes the methodology, based on Monte Carlo simulations of the wavefront-sensing analysis of focus-sweep data, used to establish the uncertainties of the wavefront error maps.

wavefront error↗

Wavefront-Error Performance Characterization for the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) Science Instruments

The science instruments (SIs) comprising the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) were tested in three cryogenic-vacuum test campaigns in the NASA Goddard Space Flight Center (GSFC)'s Space Environment Simulator (SES) test chamber. In this paper, we describe the results of optical wavefront-error performance characterization of the SIs. The wavefront error is determined using image-based wavefront sensing, and the primary data used by this process are focus sweeps, a series of images recorded by the instrument under test in its as-used configuration, in which the focal plane is systematically changed from one image to the next. High-precision determination of the wavefront error also requires several sources of secondary data, including 1) spectrum, apodization, and wavefront-error characterization of the optical ground-support equipment (OGSE) illumination module, called the OTE Simulator (OSIM), 2) F-number and pupil-distortion measurements made using a pseudo-nonredundant mask (PNRM), and 3) pupil geometry predictions as a function of SI and field point, which are complicated because of a tricontagon-shaped outer perimeter and small holes that appear in the exit pupil due to the way that different light sources are injected into the optical path by the OGSE. One set of wavefront-error tests, for the coronagraphic channel of the Near-Infrared Camera (NIRCam) Longwave instruments, was performed using data from transverse translation diversity sweeps instead of focus sweeps, in which a sub-aperture is translated and/or rotated across the exit pupil of the system. Several optical-performance requirements that were verified during this ISIM-level testing are levied on the uncertainties of various wavefront-error-related quantities rather than on the wavefront errors themselves. This paper also describes the methodology, based on Monte Carlo simulations of the wavefront-sensing analysis of focus-sweep data, used to establish the uncertainties of the wavefront-error maps.

image analysis↗

Assessing the Impact of Observations in a Multi-Year Reanalysis (MERRA-2)

Operational and quasi-operational weather prediction centers have been routinely assessing the contribution from various observing systems to reducing errors in short-range forecasts for a number of years now. The original technique, Forecast Sensitivity-based Observation Impact (FSOI), involves definition of a forecast error measure and evaluation of sensitivities with respect to changes in the observations that require adjoint operators of both the underlying tangent linear model and corresponding analysis technique. The present work applies FSOI to reanalysis and aims at providing an expanded view of the contribution of various observing systems over nearly 40 years of assimilation. Specifically, this study uses MERRA-2 given that its supporting software includes all ingredients necessary to calculate FSOI. Part of this work shows how the quality of forecasts improves over the course of the reanalysis, and examines forecast sensitivities relevant to FSOI. The assessment here finds, for example, that: conventional observations are a major player in reducing forecast error throughout the 40 years of reanalysis, even when their volume reduces from 45\% in the earlier periods to about 5% in the modern era; satellite radiances, especially microwave instruments are major contributors to error reduction from the early single platform TIROS-N days to the current multi-platform scenario, though their fractional contribution reduces slightly from the early 2000's onward after the increased availability of wind observation from aircraft and atmospheric motion vectors, and the introduction of GPSRO; infrared instruments play a secondary role to microwave but are significant still, with the peculiar result of fractional impacts contribution from modern hyperspectral instruments being roughly similar to those from early infrared instruments. The dependence of results on the chosen error measure is emphasized throughout.

Todling, Ricardo↗

Far-infrared room-temperature focal plane modules for polar radiant energy in the Far InfraRed experiment

This work presents focal plane modules for Polar Radiant Energy in the Far InfraRed Experiment, a passive remote-sensing instrument aimed to determine errors in the estimated outgoing longwave radiation in the Earth’s polar regions to reduce uncertainties in surface emissivity, mass balance, and ice flux. The focal plane arrays are micromachined at JPL and integrated into sub-assembly modules to be mounted on the optical telescope of the instrument.

White, Mary↗

TPSAS-NF1676L-17894-DND

Are domain-aggregated, long-term climate trends in retrieved reflected solar cloud properties detectable despite instrument related and algorithm-related aliasing errors? Science Question: By how much do changes in instrument calibration distort reflected solar cloud property decadal trends? Objective: Quantify how changes in calibration error feed into cloud property changes. Science Question: By how much do reflected solar cloud property retrieval assumptions distort trends in retrieved cloud properties? Objective: Quantify how the plane-parallel assumption in reflected solar satellite cloud retrievals distorts cloud optical thickness decadal trends by determining how and if the large-scale 3D optical thickness bias changes over time. - The three panel procedure below will be performed for each time (month), (zonal) region, set of solar and viewing geometries.

Yolanda Roberts↗

Characterization and Uncertainty Analysis of a Reference Pressure Measurement System for Wind Tunnels

This paper presents the calibration results and uncertainty analysis of a high-precision reference pressure measurement system currently used in wind tunnels at the NASA Langley Research Center (LaRC). Sensors, calibration standards, and measurement instruments are subject to errors due to aging, drift with time, environment effects, transportation, the mathematical model, the calibration experimental design, and other factors. Errors occur at every link in the chain of measurements and data reduction from the sensor to the final computed results. At each link of the chain, bias and precision uncertainties must be separately estimated for facility use, and are combined to produce overall calibration and prediction confidence intervals for the instrument, typically at a 95% confidence level. The uncertainty analysis and calibration experimental designs used herein, based on techniques developed at LaRC, employ replicated experimental designs for efficiency, separate estimation of bias and precision uncertainties, and detection of significant parameter drift with time. Final results, including calibration confidence intervals and prediction intervals given as functions of the applied inputs, not as a fixed percentage of the full-scale value are presented. System uncertainties are propagated beginning with the initial reference pressure standard, to the calibrated instrument as a working standard in the facility. Among the several parameters that can affect the overall results are operating temperature, atmospheric pressure, humidity, and facility vibration. Effects of factors such as initial zeroing and temperature are investigated. The effects of the identified parameters on system performance and accuracy are discussed.

Amer, Tahani↗

Ka-band Phase Measurement System for SWOT Mission

The KaRIn (Ka-band radar interferometer) instrument for SWOT (surface water ocean topography) mission faces unique challenges in terms of phase stability and group delay stability requirements to achieve centimeter level accuracy for height measurements. Conventional altimetry assumes nadir point return and measures a single range. SWOT will require additional angle of arrival information to provide swath coverage. Errors in differential phase and common group delay can both act as primary sources of systematic errors in determining the height using interferometric data. The ground support equipment (GSE) necessary for the performance requirements verification gets a fraction of the error allocation from the instrument. A phase measurement system capable of measuring millidegrees and working with pulsed excitation is developed and the preliminary results are described in this paper.

Esteban-Fernandez, Daniel↗

CLARREO Approach for Reference Intercalibration of Reflected Solar Sensors: On-Orbit Data Matching and Sampling

The implementation of the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission was recommended by the National Research Council in 2007 to provide an on-orbit intercalibration standard with accuracy of 0.3% (k = 2) for relevant Earth observing sensors. The goal of reference intercalibration, as established in the Decadal Survey, is to enable rigorous high-accuracy observations of critical climate change parameters, including reflected broadband radiation [Clouds and Earth's Radiant Energy System (CERES)], cloud properties [Visible Infrared Imaging Radiometer Suite (VIIRS)], and changes in surface albedo, including snow and ice albedo feedback. In this paper, we describe the CLARREO approach for performing intercalibration on orbit in the reflected solar (RS) wavelength domain. It is based on providing highly accurate spectral reflectance and reflected radiance measurements from the CLARREO Reflected Solar Spectrometer (RSS) to establish an on-orbit reference for existing sensors, namely, CERES and VIIRS on Joint Polar Satellite System satellites, Advanced Very High Resolution Radiometer and follow-on imagers on MetOp, Landsat imagers, and imagers on geostationary platforms. One of two fundamental CLARREO mission goals is to provide sufficient sampling of high-accuracy observations that are matched in time, space, and viewing angles with measurements made by existing instruments, to a degree that overcomes the random error sources from imperfect data matching and instrument noise. The data matching is achieved through CLARREO RSS pointing operations on orbit that align its line of sight with the intercalibrated sensor. These operations must be planned in advance; therefore, intercalibration events must be predicted by orbital modeling. If two competing opportunities are identified, one target sensor must be given priority over the other. The intercalibration method is to monitor changes in targeted sensor response function parameters: effective offset, gain, nonlinearity, optics spectral response, and sensitivity to polarization. In this paper, we use existing satellite data and orbital simulationmethods to determinemission requirements for CLARREO, its instrument pointing ability, methodology, and needed intercalibration sampling and data matching for accurate intercalibration of RS radiation sensors on orbit.

radiometry↗

CLARREO: Reference Inter-Calibration on Orbit With Reflected Solar Spectrometer

The CLARREO approach for reference intercalibration is based on obtaining coincident highly accurate spectral reflectance and reflected radiance measurements, and establish an on-orbit reference for existing Earth viewing reflected solar radiation sensors: CERES and VIIRS on JPSS satellites, AVHRR and follow-on imagers on MetOp, and imagers on GEO platforms. The mission goal is to be able to provide CLARREO RS reference observations that are matched in space, time, and viewing angles with measurements from the aforementioned instruments, with sampling sufficient to overcome the random error sources from imperfect data matching and instrument noise. The intercalibration method is to monitor over time changes in targeted sensor response function parameters: effective offset, gain, nonlinearity, spectral degradation, and sensitivity to polarization of optics.

Lukashin, C.↗