Design considerations and strategies for lunar-based observations

This paper addresses the design considerations and strategies for astrophysical observations as key elements of an international solar system exploration program. Emphasis is placed on the technical and programmatic challenges and opportunities associated with an evolving program of lunar-based astronomy. Both robotic and human tended facilities are discussed ranging from relatively small meter-class transit telescopes to large interferometer and filled-aperture systems.

Snoddy, William C.↗

NOSS/ALDCS analysis and system requirements definition

The results of system analyses and implementation studies of an advanced location and data collection system (ALDCS) , proposed for inclusion on the National Oceanic Satellite System (NOSS) spacecraft are reported. The system applies Doppler processing and radiofrequency interferometer position location technqiues both alone and in combination. Aspects analyzed include: the constraints imposed by random access to the system by platforms, the RF link parameters, geometric concepts of position and velocity estimation by the two techniques considered, and the effects of electrical measurement errors, spacecraft attitude errors, and geometric parameters on estimation accuracy. Hardware techniques and trade-offs for interferometric phase measurement, ambiguity resolution and calibration are considered. A combined Doppler-interferometer ALDCS intended to fulfill the NOSS data validation and oceanic research support mission is also described.

Reed, D. L.↗

The relationship of storm severity to directionally resolved radio emissions

The objective was to provide continuous observation of atmospheric electrical activity occurring in association with tropical storms in the Gulf of Mexico. The observations were to include the location of all detected intracloud and cloud-to-ground lightning activity occurring in the storm. To provide synoptic scale coverage, a phase linear interferometer high frequency direction finder (HFDF) system was constructed and developed at Marshall Space Flight Center (MSFC). This was used in concert with the existing HFDF interferometer at the southwest research institute to provide lightning location data through triangulation. Atmospheric electrical events were synchronized through the use of satellite receivers at each site. The intent of the data analysis was to correlate the location of electrical centers of activity with radar and satellite imagry to identify areas of intense convection within the tropical storm system. Analysis of the hurricane Alicia data indicate a center of atmospheric electrical activity associated with the vortex of the storm. The center appears to rotate from the Northern side of the vortex to the Southern side during the period of observation. An analysis of the atmospheric electrical burst rates associated with hurrican Alicia indicates that the electrical activity appears to maximize at the time of greatest storm intensity, i.e., maximum winds and lowest central pressure.

Johnson, R. L.↗

Intercontinental clock synchronization with the block 1 VLBI system

The Block 1 very long baseline interferometer (VLBI) operated by the Deep Space Network (DSN) to make weekly measurements of the relative epoch and rate offsets between the time standards in the global network of DSN stations is discussed. The precision of these measurements routinely achieves sub-microsecond levels for epoch offset and accuracies of better than one part in 10 to the 12th power for rate offset. The implementation of the phase calibrator system permits absolute measurement of epoch offset to better than 10 nanoseconds. With the near-real-time play-back and on-line storage of VLBI data, the Block 1 system typically produces clock parameters within 48 hours from the time of observation.

Roth, M. G.↗

SIM testbed 3 real-time control software

SIM System Testbed 3 (STB3) features three optical interferometers sharing a common baseline, as a dynamic representation of the SIM instrument. An artificial star feeding the interferometers is installed on a separate optics bench. All three interferometers use photons captured by avalanche photo diodes (APDs) to measure the position and quality of fringes, and additional pointing precision is achieved by fast steering mirrors (FSMs) that keep the star images centered on the beam combining optics using a CCD camera. Each interferometer uses internal metrology to measure changes in its optical pathlength. External metrology beams measure changes in the baseline vector. This system acquires and tracks white light fringes with one interferometer, while the other two acquire and track laser light fringes representing the bright guide stars that will be used by SIM. The white light source represents a dim star that cannot supply enough photons for the Science interferometer to lock onto fringes in closed-loop mode; instead it operates open-loop, using pathlength corrections fed to it from the two guide interferometers and the external metrology subsystem to reject disturbances and maintain the fringes. This tracking mode is known as Pathlength Feed Forward (PFF). The precise real-time behavior required to achieve this result is implemented by a complex set of interacting software control loops. This paper describes how these loops take advantage of the benefits of the RTC Core architecture, and how they work together to accomplish STB3's objectives.

interferometry↗

Three component velocity measurements using Fabry-Perot interferometer

A method for measuring the three components of mean flow velocity using a backscatter optical system based on a confocal Fabry-Perot interferometer is described. An analysis of the expected uncertainties in the velocity component measurements is presented along with experimental data taken in a free jet at two flow velocities (100 and 300 m/s).

Seasholtz, R. G.↗

Three component velocity measurements using Fabry-Perot interferometer

A method for measuring the three components of mean flow velocity using a backscatter optical system based on a confocal Fabry-Perot interferometer is described. An analysis of the expected uncertainties in the velocity component measurements is presented along with experimental data taken in a free jet at two flow velocities (100 and 300 m/s).

Seasholtz, R. G.↗

Multiple Etalon Systems for the Advanced Technology Solar Telescope

Multiple etalons systems are discussed that meet the 4-meter NSO/Advance Technology Solar Telescope (http://www.nso.edu/ATST/index.html) instrument and science requirements for a narrow bandpass imaging system. A multiple etalon system can provide an imaging interferometer working in four distinct modes: as a spectro-polarimeter, a filter-vector magnetograph, and a wide-band and broad-band high-resolution imager. Specific dual and triple etalon configurations will be described that provides spectrographic passband of 2.0-3.5nm and reduces parasitic light levels to 1/10000 as required by precise polarization measurement, e.g., Zeeman measurements of magnetic sensitive lines. A TESOS-like triple etalon system provides for spectral purity of 100 thousandths. The triple designs have the advantage of reducing the finesse requirement on each etalon, allowing much more stable blocking filters, and can have very high spectral purity. A dual-etalon double-pass Cavallini-like configuration can provide a competing configuration. This design can provide high contrast with only a double etalon. The selection of the final focal plan instrument will depend on a trade-off of the ideal instrument versus reality, the number of etalons, the aperture of etalons, the number of blocking filters the electronic control system and computer interfaces, the temperature control and controllers for the etalons and the electronics. The use of existing experience should provide significant cost savings. The heritage of use of etalons and multiple etalon systems in solar physics come from a number of observatories, which includes MSFC Solar Observatory (NASA), Sac Peak Observatory (NSO), and Kiepenheuer Institute for Solar Physics (Germany), Mees Solar Observatory (University of Hawaii), and Arcetri Astrophysical Observatory (Italy). The design of the ATST multiple etalon system will reply on the existing experience from these observatories.

Gary, G. Allen↗

Multiple-etalon systems for the Advanced Technology Solar Telescope

Multiple etalon systems are discussed that meet the science requirements for a narrow-passband imaging system for the 4-meter National Solar Observatory (NSO)/Advance Technology Solar Telescope (ATST). A multiple etalon system can provide an imaging interferometer that works in four distinct modes: as a spectro-polarimeter, a filter-vector magnetograph, an intermediate-band imager, and broadband high-resolution imager. Specific dual and triple etalon configurations are described that provide a spectrographic passband of 2.0-3.5 micron and reduce parasitic light levels to 10(exp -4) as required for precise polarization measurement, e.g., Zeeman measurements of magnetic sensitive lines. A TESOS-like (Telecentric Etalon SOlar Spectrometer) triple etalon system provides a spectral purity of 10(exp -5). The triple designs have the advantage of reducing the finesse requirement on each etalon; allow the use of more stable blocking filters, and have very high spectral purity. A dual-etalon double-pass (Cavallini-like) system can provide a competing configuration. Such a dual-etalon design can provide high contrast. The selection of the final focal plane instrument will depend on a trade-off between an ideal instrument and practical reality. The trade study will include the number of etalons, their aperture sizes, complexities of the optical train, number of blocking filters, configuration of the electronic control system, computer interfaces, temperature controllers, etalon controllers, and their associated feedback electronics. The heritage of single and multiple etalon systems comes from their use in several observatories, including the Marshall Space Flight Center (MSFC) Solar Observatory, Sacramento Peak Observatory (NSO), and Kiepenheuer-Institut fur Sonnenphysik (KIS, Germany), Mees Solar Observatory (University of Hawaii), and Arcetri Astrophysical Observatory (Italy). The design of the ATST multiple etalon system will benefit from the experience gained at these observatories.

Gary, G. Allen↗

Observations of winds with an incoherent lidar detector

A Fabry-Perot interferometer and image-plane detector system to be used as a receiver for a Doppler lidar have been developed. This system incorporates the latest technology in multichannel detectors, and it is an important step toward the development of operational wind profiler systems for the atmosphere. The instrumentation includes a stable high-resolution optically contacted plane etalon and a multiring anode detector to scan the image plane of the Fabry-Perot interferometer spatially. The high wavelength resolution provided by the interferometer permits the aerosol and molecular components of the backscattered signal to be distinguished, and the Doppler shift of either component can then be used to determine the wind altitude profile. The receiver performance has been tested by measuring the wind profile in the boundary layer. The Fabry-Perot interferometer and image-plane detector characteristics are described and sample measurements are presented. The potential of the system as a wind profiler in the troposphere, the stratosphere, and the mesosphere is also considered.

Abreu, Vincent J.↗

Atomic References for Measuring Small Accelerations

Accelerometer systems that would combine the best features of both conventional (e.g., mechanical) accelerometers and atom interferometer accelerometers (AIAs) have been proposed. These systems are intended mainly for use in scientific research aboard spacecraft but may also be useful on Earth in special military, geological, and civil-engineering applications. Conventional accelerometers can be sensitive, can have high dynamic range, and can have high frequency response, but they lack accuracy and long-term stability. AIAs have low frequency response, but they offer high sensitivity, and high accuracy for measuring small accelerations. In a system according to the proposal, a conventional accelerometer would be used to perform short-term measurements of higher-frequency components of acceleration, while an AIA would be used to provide consistent calibration of, and correction of errors in, the measurements of the conventional accelerometer in the lower-frequency range over the long term. A brief description of an AIA is prerequisite to a meaningful description of a system according to the proposal. An AIA includes a retroreflector next to one end of a cell that contains a cold cloud of atoms in an ultrahigh vacuum. The atoms in the cloud are in free fall. The retroreflector is mounted on the object, the acceleration of which is to be measured. Raman laser beams are directed through the cell from the end opposite the retroreflector, then pass back through the cell after striking the retroreflector. The Raman laser beams together with the cold atoms measure the relative acceleration, through the readout of the AIA, between the cold atoms and the retroreflector.

Maleki, Lute↗

Analysis of Meteorological Satellite location and data collection system concepts

A satellite system that employs a spaceborne RF interferometer to determine the location and velocity of data collection platforms attached to meteorological balloons is proposed. This meteorological advanced location and data collection system (MALDCS) is intended to fly aboard a low polar orbiting satellite. The flight instrument configuration includes antennas supported on long deployable booms. The platform location and velocity estimation errors introduced by the dynamic and thermal behavior of the antenna booms and the effects of the presence of the booms on the performance of the spacecraft's attitude control system, and the control system design considerations critical to stable operations are examined. The physical parameters of the Astromast type of deployable boom were used in the dynamic and thermal boom analysis, and the TIROS N system was assumed for the attitude control analysis. Velocity estimation error versus boom length was determined. There was an optimum, minimum error, antenna separation distance. A description of the proposed MALDCS system and a discussion of ambiguity resolution are included.

Wallace, R. G.↗

Astrophysical Adaptation of Points, the Precision Optical Interferometer in Space

POINTS (Precision Optical INTerferometer in Space) would perform microarcsecond optical astrometric measurements from space, yielding submicroarcsecond astrometric results from the mission. It comprises a pair of independent Michelson stellar interferometers and a laser metrology system that measures both the critical starlight paths and the angle between the baselines. The instrument has two baselines of 2 m, each with two subapertures of 35 cm; by articulating the angle between the baselines, it observes targets separated by 87 to 93 deg. POINTS does global astrometry, i.e., it measures widely separated targets, which yields closure calibration, numerous bright reference stars, and absolute parallax. Simplicity, stability, and the mitigation of systematic error are the central design themes. The instrument has only three moving-part mechanisms, and only one of these must move with sub-milliradian precision; the other two can tolerate a precision of several tenths of a degree. Optical surfaces preceding the beamsplitter or its fold flat are interferometrically critical; on each side of the interferometer, there are only three such. Thus, light loss and wavefront distortion are minimized. POINTS represents a minimalistic design developed ab initio for space. Since it is intended for astrometry, and therefore does not require the u-v-plane coverage of an imaging, instrument, each interferometer need have only two subapertures. The design relies on articulation of the angle between the interferometers and body pointing to select targets; the observations are restricted to the 'instrument plane.' That plane, which is fixed in the pointed instrument, is defined by the sensitive direction for the two interferometers. Thus, there is no need for siderostats and moving delay lines, which would have added many precision mechanisms with rolling and sliding parts that would be required to function throughout the mission. Further, there is no need for a third interferometer, as is required when out-of-plane observations are made. An instrument for astrometry, unlike those for imaging, can be compact and yet scientifically productive. The POINTS instrument is compact and therefore requires no deployment of precision structures, has no low-frequency (i.e., under 100 Hz) vibration modes, and is relatively easy to control thermally. Because of its small size and mass, it is easily and quickly repointed between observations. Further, because of the low mass, it can be economically launched into high Earth orbit which, in conjunction with a solar shield, yields nearly unrestricted sky coverage and a stable thermal environment.

Reasenberg, Robert D.↗

Gas Sensors Based on Single-Arm Waveguide Interferometers

Various optical technologies can be implemented in chemical sensing. Sensitive, rugged, and compact systems will be more likely built using interferometric waveguide sensors. Currently existing sensors comprise dual-arm systems with external reference arm, dual-arm devices with internal reference arm such as integrated Mach-Zehnder interferometer, and single-arm systems which employ the interference between different waveguide modes. These latter ones are the most compact and rugged but still sensitive enough to monitor volatile pollutants such as NH3 coming out of industrial refrigerators and fertilizer plants and stocks, NO, NO2, SO2, emitted by industrial burning processes. Single-arm devices in planar waveguide configuration most frequently use two orthogonally polarized modes TE (sub i) and TM (sub i) of the same order i. Sensing effect is based on the difference in propagation conditions for the modes caused by the environment. However, dual-mode single-order interferometers still have relatively low sensitivity with respect to the environment related changes in the waveguide core because of small difference between propagation constants of TE (sub i) and TM (sub i) modes of the same order. Substantial sensitivity improvement without significant complication can be achieved for planar waveguide interferometers using modes of different orders with much greater difference between propagation constants.

Sarkisov, Sergey↗

Preliminary design of the cryogenic cooled limb scanning interferometer radiometer (CLIR), phase 2

A cryogenic system to be utilized with a mounted pointing system is designed. The analysis indicates that the resulting design is significantly heavier than previous design due to the increased diameter of the system, resulting in greater tank and vacuum enclosure weights. Additional weight is also required in the area where the payload is attached to the pointing system in order to provide additional stiffness to the payload. The vacuum shell required to enclose the instrument is shorter and therefore an attendant reduction in instrument package weight would be expected. The primary resonance of the cooler instrument package occurs at 21 Hz, a mode in which the flexibility of the vacuum shell allows motion of the cryogen tank and instrument, and which can be increased by additional stiffening in the region of the pointing system vacuum shell connection at the cost of additional weight. The second resonance at 59 Hz is due to vibration of the helium tank on the fiberglass support tubes. The parasitic heat load can be reduced to 0.28 W by the utilization of a sandwich support tube structure in place of the monocoque structure assumed in the design.

Source record↗

Metrology system for Space Interferometry Mission system testbed 3

In a 3-baseline interferometer fourteen metrology gauges are used to monitor changes in the two baselines and calculate the length of the third. Simulation for estimating the third baseline indicates measurement capability of better than 1 nm error.

interferometry↗

Stabilization of interferometer fringe patterns

Fringe pattern motion is compensated by closed-loop servo system that adjusts a mirror mounted on piezoelectric crystal, so that path difference in interferometer is maintained at constant values at one point in the field. System is applicable to holography with continuous wave laser sources.

Brown, R. M.↗

Compact magnetograph

A compact magnetograph system based on solid Fabry-Perot interferometers as the spectral isolation elements was studied. The theory of operation of several Fabry-Perot systems, the suitability of various magnetic lines, signal levels expected for different modes of operation, and the optimal detector systems were investigated. The requirements that the lack of a polarization modulator placed upon the electronic signal chain was emphasized. The PLZT modulator was chosen as a satisfactory component with both high reliability and elatively low voltage requirements. Thermal control, line centering and velocity offset problems were solved by a Fabry-Perot configuration.

Title, A. M.↗