Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERLOCKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Multiscale System Modeling of Single-Event-Induced Faults in Advanced Node Processors

Integration-technology feature shrink increases computing-system susceptibility to single-event effects (SEE). While modeling SEE faults will be critical, an integrated processor’s scope makes physically correct modeling computationally intractable. Without useful models, presilicon evaluation of fault-tolerance approaches becomes impossible. To incorporate accurate transistor-level effects at a system scope, we present a multiscale simulation framework. Charge collection at the 1) device level determines 2) circuit-level transient duration and state-upset likelihood. Circuit effects, in turn, impact 3) register-transfer-level architecture-state corruption visible at 4) the system level. Furthermore, the physically accurate effects of SEEs in large-scale systems, executed on a high-performance computing (HPC) simulator, could be used to drive cross-layer radiation hardening by design. We demonstrate the capabilities of this model with two case studies. First, we determine a D flip-flop’s sensitivity at the transistor level on 14-nm FinFet technology, validating the model against published cross sections. Second, we track and estimate faults in a microprocessor without interlocked pipelined stages (MIPS) processor for Adams 90% worst case environment in an isotropic space environment.

42 ENGINEERING↗

The impact of interventions in the global land and agri-food sectors on Nature’s Contributions to People and the UN Sustainable Development Goals

Interlocked challenges of climate change, biodiversity loss and land degradation require transformative interventions in the land management and food production sectors to reduce carbon emissions, strengthen adaptive capacity, and maintain or increase food production to 2050. However, deciding which interventions to pursue and understanding their relative synergies with and trade-offs against different social and environmental goals has been difficult without direct comparisons across a range of possible actions. This study examined a series of 40 different options, implemented through land, value chain or risk management, for their relative impacts across 18 Nature’s Contributions to People (also known as ecosystem services) and the 17 Sustainable Development Goals. We find that a relatively small number of interventions show significant positive synergies with both SDGs and NCPs; these include improved cropland management, improved grazing land management, improved livestock management, agroforestry, agricultural diversification, increased soil organic carbon content, reduced soil erosion, salinization and compaction, fire management, reduced landslides and hazards, reduced pollution, management of invasive species, sustainable source, and reduced post-harvest losses. Several interventions show strong negative impacts on either SDGs, NCPs or in some cases, both; these include bioenergy and BECCS, afforestation, and some risk sharing measures, like commercial crop insurance. Our results demonstrate that a better understanding of benefits and trade-offs of comparative policy approaches can help decision-makers choose the most effective, or at the very minimum, benign interventions for implementation in specific contexts.

Mcelwee, Pam↗

Microstructural examination of interactions between chromia-based refractory and nuclear glass in a melter

This study shows the effects of nuclear waste glass production on Monofrax K-3 refractory corrosion. A continuously fed research-scale melter containing an Fe- and Ni-rich simulated nuclear waste feed with borosilicate glass-forming chemicals was cyclically melted at 1150°C and idled at 1050°C for a total of 11 weeks. Chemical maps using scanning electron microscopy show the interactions between the quenched melt and the refractory. Nanoscale X-ray-computed tomography was used for a three-dimensional visualization of certain parts of the interface. Unreacted K-3 consists of primarily corundum (Al,Cr) 2 O 3 and spinel (Fe 2+ ,Mg)(Al,Cr) 2 O 4 interlocking crystalline phases. Some of the Cr from the refractory interacts with the Ni and Fe from the melt to form a reaction layer comprising (Ni,Fe 2+ )(Cr,Fe 3+ ) 2 O 4 spinel crystals. Simultaneously, melt components (Na,Si) infiltrate into the refractory. This interaction proceeds at the expense of the integrity of the refractory structure. Intact refractory grains (e.g., (Al,Cr) 2 O 3 ) as well as the reaction layer itself can lose mechanical integrity and spall off into the melt, especially near the top of the melter. As the reaction layer can be a protective boundary for the refractory against further melt infiltration, a reduction in the reaction layer thickness allows an increase in refractory corrosion.

36 MATERIALS SCIENCE↗

Joining Dissimilar Materials Using Friction Stir Scribe Technique

Development of a robust and cost-effective method of joining dissimilar materials could provide a critical pathway to enable widespread use of multi-material designs and components in mainstream industrial applications. The use of multi-material components such as steel-aluminum and aluminum-polymer would allow design engineers to optimize material utilization based on service requirements and could often lead to weight and cost reductions. However, producing an effective joint between materials with vastly different thermal, microstructural, and deformation responses is highly problematic using conventional joining and/or fastening methods. This is especially challenging in cost sensitive, high volume markets that largely rely on low cost joining solutions. Friction stir scribe technology was developed to meet the demands of joining materials with drastically different properties and melting regimes. The process enables joining of light metals like magnesium and aluminum to high temperature materials like steel and titanium. Viable joints between polymer composites and metal can also be made using this method. This paper will present the state of the art, progress made, and challenges associated with this innovative derivative of friction stir welding in reference to joining dissimilar metals and polymer/metal combinations.

Upadhyay, Piyush↗

Experimental Evaluation of Geopolymer, Nano-Modified, and Neat Class H Cement by Using Diametrically Compressive Tests

Abstract Cement is the prime barrier material to maintain zonal isolation during wellbore life-cycle. Different types of the cement have different performances on sealability. The primary objective of this study is evaluation of three types of cement systems, neat Class H, nano-synthetic graphite, and rock-based geopolymer cements, on interfacial bond integrity. Diametrical compressive tests are used on casing–cement–formation systems. Cement performances are tested in a conventional configuration (Berea Sandstone). A universal testing system is utilized to analyze the relationship applied load–axial strain and the digital image correlation (DIC) technique is used to generate the strain field maps. Based on the relationship and DIC results, bond strengths in different cement systems are evaluated. Additionally, microscope images provide insight explanations of the bond from micro-view. Based on the experimental results, failures of all cases initiate and propagate from the casing–cement interface. Then, radial cracks develop through the formation. This is because the mechanical interlocking bonds are formed only at the cement–sandstone interface to enhance the bond strength. The comparison of geopolymer and nano-modified cements with the conventional cement (neat Class H) shows that the unconventional cements have a lower maximum load and higher axial strain before failure of the samples. It indicates that both the two kinds of cements are more ductile than conventional cement and can support more deformation before the initiation of cracks.

Energy & Fuels↗

Mechanical and Corrosion Assessment of Friction Self-Piercing Rivet Joint of Carbon Fiber-Reinforced Polymer and Magnesium Alloy AZ31B

In the present work, thermoset carbon fiber–reinforced polymer (CFRP) was spot joined to magnesium alloy AZ31B by a friction self-piercing riveting (F-SPR) process. Lap shear tensile and cross-tension testing were used to evaluate the mechanical joint performance. An average lap shear tensile load of 5.18 kN was achieved, while an average of 2.81 kN was found from cross-tension testing. All F-SPR samples showed a pullout of AZ31B after mechanical testing, indicating good mechanical interlocking between the steel rivet and AZ31B. Corrosion potential was measured for each material to establish the galvanic corrosion characteristics. As expected, AZ31B was found to be the most active, while thermoset CFRP was the most noble. The steel rivet fell between the AZ31B (active) and the thermoset CFRP (noble). Salt fog corrosion testing (ASTM B-117) was performed to evaluate the corrosion performance of the uncoated F-SPR joint. With up to 200 h of exposure, the post-corroded F-SPR joint integrity retained 81.2% of the pre-exposure F-SPR joint strength with AZ31B pullout failure mode. From cross-sectional analysis of the F-SPR joint, extensive corrosion of AZ31B was observed at the joint and other exposure areas. However, steel rivet was not significantly corroded due to sacrificial anode effect by which AZ31B corroded first in the galvanic couple.

36 MATERIALS SCIENCE↗

MECHANICAL AND CORROSION ASSESSMENT OF FRICTION SELF-PIERCING RIVET JOINT OF CARBON FIBER-REINFORCED POLYMER AND MAGNESIUM ALLOY AZ31B

In the present work, thermoset carbon fiber–reinforced polymer (CFRP) was spot joined to magnesium alloy AZ31B by a friction self-piercing riveting (F-SPR) process. Lap shear tensile and cross-tension testing were used to evaluate the mechanical joint performance. An average lap shear tensile load of 5.18 kN was achieved, while an average of 2.81 kN was found from cross-tension testing. All F-SPR samples showed pull-out of AZ31B after mechanical testing, indicating good mechanical interlocking between the steel rivet and AZ31B. Corrosion potential was measured for each material to establish the galvanic corrosion characteristics. As expected, AZ31B was found to be the most active, while thermoset CFRP was the most noble. The steel rivet fell between the AZ31B (active) and the thermoset CFRP (noble). Salt fog corrosion testing (ASTM B-117) was performed to evaluate the corrosion performance of the uncoated F-SPR joint. With up to 200 h of exposure, the post-corroded F-SPR joint integrity retained 81.2% of the pre-exposure F-SPR joint strength with AZ31B pull-out failure mode. From cross-sectional analysis of the F-SPR joint, extensive corrosion of AZ31B was observed at the joint and other exposure areas. However, steel rivet was not significantly corroded potentially due to sacrificial anode effect by which AZ31B corroded first in the galvanic couple.

Lim, Yong Chae↗

Commissioning of the discrete spot scanning proton beam delivery system at University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston

Purpose: To describe a summary of the clinical commissioning of the discrete spot scanning proton beam at the Proton Therapy Center, Houston (PTC-H). Methods: Discrete spot scanning system is composed of a delivery system (Hitachi ProBeat), an electronic medical record (Mosaiq V 1.5), and a treatment planning system (TPS) (Eclipse V 8.1). Discrete proton pencil beams (spots) are used to deposit dose spot by spot and layer by layer for the proton distal ranges spanning from 4.0 to 30.6 g/cm{sup 2} and over a maximum scan area at the isocenter of 30x30 cm{sup 2}. An arbitrarily chosen reference calibration condition has been selected to define the monitor units (MUs). Using radiochromic film and ion chambers, the authors have measured spot positions, the spot sizes in air, depth dose curves, and profiles for proton beams with various energies in water, and studied the linearity of the dose monitors. In addition to dosimetric measurements and TPS modeling, significant efforts were spent in testing information flow and recovery of the delivery system from treatment interruptions. Results: The main dose monitors have been adjusted such that a specific amount of charge is collected in the monitor chamber corresponding to a single MU, following the IAEA TRS 398 protocol under a specific reference condition. The dose monitor calibration method is based on the absolute dose per MU, which is equivalent to the absolute dose per particle, the approach used by other scanning beam institutions. The full width at half maximum for the spot size in air varies from approximately 1.2 cm for 221.8 MeV to 3.4 cm for 72.5 MeV. The measured versus requested 90% depth dose in water agrees to within 1 mm over ranges of 4.0-30.6 cm. The beam delivery interlocks perform as expected, guarantying the safe and accurate delivery of the planned dose. Conclusions: The dosimetric parameters of the discrete spot scanning proton beam have been measured as part of the clinical commissioning program, and the machine is found to function in a safe manner, making it suitable for patient treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric characterization of a multileaf collimator for a new four-dimensional image-guided radiotherapy system with a gimbaled x-ray head, MHI-TM2000

Purpose: To present the dosimetric characterization of a multileaf collimator (MLC) for a new four-dimensional image-guided radiotherapy system with a gimbaled x-ray head, MHI-TM2000. Methods: MHI-TM2000 has an x-ray head composed of an ultrasmall linear accelerator guide and a system-specific MLC. The x-ray head can rotate along the two orthogonal gimbals (pan and tilt rotations) up to {+-}2.5 deg., which swings the beam up to {+-}41.9 mm in each direction from the isocenter on the isocenter plane perpendicular to the beam. The MLC design is a single-focus type, has 30 pairs of 5 mm thick leaves at the isocenter, and produces a maximum field size of 150x150 mm{sup 2}. Leaf height and length are 110 and 260 mm, respectively. Each leaf end is circular, with a radius of curvature of 370 mm. The distance that each leaf passes over the isocenter is 77.5 mm. Radiation leakage between adjacent leaves is minimized by an interlocking tongue-and-groove (T and G) arrangement with the height of the groove part 55 mm. The dosimetric characterizations including field characteristics, leaf position accuracy, leakage, and T and G effect were evaluated using a well-commissioned 6 MV photon beam, EDR2 films (Kodak, Rochester, NY), and water-equivalent phantoms. Furthermore, the field characteristics and leaf position accuracy were evaluated under conditions of pan or tilt rotation. Results: The differences between nominal and measured field sizes were within {+-}0.5 mm. Although the penumbra widths were greater with wider field size, the maximum width was <5.5 mm even for the fully opened field. Compared to the results of field characteristics without pan or tilt rotation, the variation in field size, penumbra width, flatness, and symmetry was within {+-}1 mm/1% at the maximum pan or tilt rotational angle. The leaf position accuracy was 0.0{+-}0.1 mm, ranging from -0.3 to 0.2 mm at four gantry angles of 0 deg., 90 deg., 180 deg., and 270 deg. with and without pan or tilt rotation. The interleaf leakage was up to 0.21%, whereas the intraleaf leakage was <0.12%. T and G decreased the doses by 10.7%, on average. Conclusions: This study demonstrated that MHI-TM2000 has the capability for high leaf position accuracy and low leakage, leading to highly accurate intensity-modulated radiotherapy delivery. Furthermore, substantial changes in the dosimetric data on field characteristics and leaf position accuracy were not observed even at the maximum pan or tilt rotation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design and dosimetric characteristics of a new endocavitary contact radiotherapy system using an electronic brachytherapy source

Purpose: To present design aspects and acceptance tests performed for clinical implementation of electronic brachytherapy treatment of early stage rectal adenocarcinoma. A dosimetric comparison is made between the historically used Philips RT-50 unit and the newly developed Axxent{sup Registered-Sign} Model S700 electronic brachytherapy source manufactured by Xoft (iCad, Inc.). Methods: Two proctoscope cones were manufactured by ElectroSurgical Instruments (ESI). Two custom surface applicators were manufactured by Xoft and were designed to fit and interlock with the proctoscope cones from ESI. Dose rates, half value layers (HVL), and percentage depth dose (PDD) measurements were made with the Xoft system and compared to historical RT-50 data. A description of the patient treatment approach and exposure rates during the procedure is also provided. Results: The electronic brachytherapy system has a lower surface dose rate than the RT-50. The dose rate to water on the surface from the Xoft system is approximately 2.1 Gy/min while the RT-50 is 10-12 Gy/min. However, treatment times with Xoft are still reasonable. The HVLs and PDDs between the two systems were comparable resulting in similar doses to the target and to regions beyond the target. The exposure rate levels around a patient treatment were acceptable. The standard uncertainty in the dose rate to water on the surface is approximately {+-}5.2%. Conclusions: The Philips RT-50 unit is an out-of-date radiotherapy machine that is no longer manufactured with limited replacement parts. The use of a custom-designed proctoscope and Xoft surface applicators allows delivery of a well-established treatment with the ease of a modern radiotherapy device. While the dose rate is lower with the use of Xoft, the treatment times are still reasonable. Additionally, personnel may stand farther away from the Xoft radiation source, thus potentially reducing radiation exposure to the operator and other personnel.

60 APPLIED LIFE SCIENCES↗

SU-E-J-44: Design a Platform and Phantom Model for Photoacoustic Imaging in Combination with CT

Purpose: Our (long-term) objective is to develop a US manipulator that will provide in situ radiation response and image-guided therapy for bladder cancer based on photoacoustic molecular imaging. Methods: A platform was devised to provide a reproducible positional frame of reference for targeting anatomic structure between MDCT and US scans, in lieu of CBCT, and to fuse photoacoustic molecular imaging. US and photoacoustic scans are taken of a patient while in the CT scanner and IRMT. Through co-registration, based on anatomical positions, we identified a common coordinate system to be used in Eclipse. A bladder phantom was constructed to validate anatomical tracking via US and photoacoustic imaging. We tested the platform using phantom model to demonstrate validity once moved from the CT couch to the linear accelerator couch. Results: This platform interlocks with Varian exact couch index points for reproducibility of positioning. Construction from low Z material and sized appropriately to fit in CT/IMRT gantry. Error in conversion from cylindrical coordinates of the manipulator to X, Y, Z coordinates of the treatment couch was less than 1mm. We measured the bladder size in 3 different directions in both Eclipse from the CT and Acuson from US. The error was less than 2mm in all directions. CT and US images were co-registered in MATLAB. Co-registration of photoacoustic images is still being developed. Conclusion: For Linear Accelerators without on board imaging, MV portal images are not a viable option for the localization of soft tissue anatomy. We believe our manipulator provides an alternative using US imaging, which will be examined in an upcoming clinical trial. We plan to examine the value of hypoxia guided treatment through photoacoustic imaging during this trial.

60 APPLIED LIFE SCIENCES↗

SU-E-T-642: Safety Procedures for Error Elimination in Cyberknife Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT)

Purpose: Cyberknife system is used for providing stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) hypofractionation scheme. The whole treatment delivery is based on live imaging of the patient. The minor error made at any stage may bring severe radiation injury to the patient or damage to the system itself. Several safety measures were taken to make the system safer. Methods: The radiation treatment provided thru a 6MV linac attached to Kuka robot (Cyberknife G4, Accuray Inc. Sunnyvale, CA, USA). Several possible errors were identified related to patient alignment, treatment planning, dose delivery and physics quality assurance. During dose delivery, manual and visual checks were introduced to confirm pre and intra-treatment imaging to reduce possible errors. One additional step was introduced to confirm that software tracking-tools had worked correctly with highest possible confidence level. Robotic head move in different orientations over and around the patient body, the rigidity of linac-head cover and other accessories was checked periodically. The vender was alerted when a tiny or bigger piece of equipment needed additional interlocked support. Results: As of our experience treating 525 patients on Cyberknife during the last four years, we saw on and off technical issues. During image acquisition, it was made essential to follow the site-specific imaging protocols. Adequate anatomy was contoured to document the respective doses. Followed by auto-segmentation, manual tweaking was performed on every structure. The calculation box was enclosing the whole image during the final calculation. Every plan was evaluated on slice-by slice basis. To review the whole process, a check list was maintained during the physics 2nd-check. Conclusion: The implementation of manual and visual additional checks introduced along with automated checks for confirmation was found promising in terms of reduction in systematic errors and making the system safer than before.

60 APPLIED LIFE SCIENCES↗

SU-E-T-410: Evaluation of Treatment Modalities for Stereotactic Lung Radiation Therapy: A Phantom Study

Purpose: To evaluate and verify the accuracy of alternative treatment modalities for stereotactic lung therapy with end-to-end testing. We compared three dimensional conformal therapy (3DCRT), dynamic conformal arc therapy (DCAT), intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) treatment using 6 MV, 6 MV flattening filter free (FFF) and 10 MV FFF photons. Methods: A QUASAR respiratory motion phantom was utilized with custom ion chamber and gafchromatic EBT2 film inserts. The phantom contained a low density lung medium with a cylindrical polystyrene tumor (35 cc). Pseudo representative structures for various organs at risk (OAR) were created. All treatment plans were created using Eclipse ver. 11 using the same image and structure sets, and delivered via Varian TrueBeam STx linear accelerator equipped with high definition MLC. Evaluation of plan quality followed ROTG 0813 criterion for conformity index (CI100%), high dose spillage, D2cm, and R50%. Results: All treatment plans met the OAR dose constraints per protocol and could be delivered without any beam hold offs or other interlocks and hence were deemed clinically safe. For equivalent beam energies, target conformity was improved for all modalities when switching to FFF mode. Treatment efficiency increased for VMAT FFF by a factor of 3–4 over IMRT, and up to factor of 7 when compared to 3DCRT. Pass rates were > 97% for all treatment using gamma criteria of 3%, 3mm. Absolute dose at iso-center was verified with ion chamber, and found to be within 2% of the treatment planning system. Conclusion: The higher dose rate associated with FFF not only reduces delivery times, but in most cases enhances plan quality. The one modality with succeeding best results for all RTOG criterions was VMAT 6 MV FFF. This end-to-end testing provides necessary confidence in the entire dose delivery chain for lung SBRT patients.

43 PARTICLE ACCELERATORS↗

Automating linear accelerator quality assurance

Purpose: The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. Methods: The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. Results: For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. Conclusions: The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.

60 APPLIED LIFE SCIENCES↗

SU-F-T-160: Commissioning of a Single-Room Double-Scattering Proton Therapy System

Purpose: To report the detailed commissioning experience for a compact double-scattering Mevion S250 proton therapy system at a University Cancer Center site. Methods: The commissioning of the proton therapy system mainly consisted of ensuring integrity of mechanical and imaging system, beam data collection, and commissioning of a treatment planning system (TPS). First, mechanical alignment and imaging were tested including safety, interlocks, positional accuracy of couch and gantry, image quality, mechanical and imaging isocenter and so on. Second, extensive beam data (outputs, PDDs, and profiles) were collected and analyzed through effective sampling of range (R) and modulation width (M) from 24 beam options. Three different output (cGy/MU) prediction models were also commissioned as primary and secondary MU calculation tool. Third, the Varian Eclipse TPS was commissioned through five sets of data collections (in-water Bragg peak scans, in-air longitudinal fluence scans, in-air lateral profiles, in-air half-beam profiles, and an HU-to-stopping-power conversion curve) and accuracy of TPS calculation was tested using in-water scans and dose measurements with a 2D array detector with block and range compensator. Finally, an anthropomorphic phantom was scanned and heterogeneity effects were tested by inserting radiochromic films in the phantom and PET activation scans for range verification in conjunction with end-to-end test. Results: Beam characteristics agreed well with the vendor specifications; however, minor mismatches in R and M were found in some measurements during the beam data collection. These were reflected into the TPS commissioning such that the TPS could accurately predict the R and M within tolerance levels. The output models had a good agreement with measured outputs (<3% error). The end-to-end test using the film and PET showed reasonably the TPS predicted dose, R and M in heterogeneous medium. Conclusion: The proton therapy system was successfully commissioned and was released for clinical use.

60 APPLIED LIFE SCIENCES↗

Crystal Structure of a CRISPR RNA-guided Surveillance Complex Bound to a ssDNA Target

In prokaryotes, RNA derived from type I and type III CRISPR loci direct large ribonucleoprotein complexes to destroy invading bacteriophage and plasmids. In Escherichia coli, this 405-kilodalton complex is called Cascade. We report the crystal structure of Cascade bound to a single-stranded DNA (ssDNA) target at a resolution of 3.03 angstroms. The structure reveals that the CRISPR RNA and target strands do not form a double helix but instead adopt an underwound ribbon-like structure. This noncanonical structure is facilitated by rotation of every sixth nucleotide out of the RNA-DNA hybrid and is stabilized by the highly interlocked organization of protein subunits. These studies provide insight into both the assembly and the activity of this complex and suggest a mechanism to enforce fidelity of target binding.

59 BASIC BIOLOGICAL SCIENCES↗

3D polycatenated architected materials

Architected materials derive their properties from the geometric arrangement of their internal structural elements. Their designs rely on continuous networks of members to control the global mechanical behavior of the bulk. Here, in this study, we introduce a class of materials that consist of discrete concatenated rings or cage particles interlocked in three-dimensional networks, forming polycatenated architected materials (PAMs). We propose a general design framework that translates arbitrary crystalline networks into particle concatenations and geometries. In response to small external loads, PAMs behave like non-Newtonian fluids, showing both shear-thinning and shear-thickening responses, which can be controlled by their catenation topologies. At larger strains, PAMs behave like lattices and foams, with a nonlinear stress-strain relation. At microscale, we demonstrate that PAMs can change their shapes in response to applied electrostatic charges. The distinctive properties of PAMs pave the path for developing stimuli-responsive materials, energy-absorbing systems, and morphing architectures.

36 MATERIALS SCIENCE↗

Novel Approach to Strengthening Ceramic Cathode Contact and Validation in a Generic Stack Test Fixture

The ceramic contact material at the cathode side has been identified as the weakest mechanical link in solid oxide fuel cells, due to poor sintering at low stack fabrication temperatures. In this work, a novel approach of mechanical interlocking with an engineered surface was proposed to strengthen LSM-type contacts. The engineered cathode surface was made by depositing large LSM20 granules onto a wet cathode print, followed by sintering. Granules of three sizes were tested (mesh #35, #60, and #100). Small coupons of anode-supported YSZ electrolyte with LSM cathode were joined at 850 and 950oC for 2h with LSM contact using either the engineered surface or plain surfaces. The results of contact strength measurements showed about 14 times increase with engineered surface compared to plain surfaces. Validation with a 2”x2” LSM-based cell in a generic stack fixture showed good thermal cycle stability with minimal change in ohmic impedance over ten cycles.

Chou, Yeong-Shyung↗