Search NASA⌕ Search

SEARCH · Search NASA

Results for “ISOTOPIC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

A Unified Interpretation of Variability in Precipitation Isotope Ratios

Abstract Several mechanisms have been proposed to explain why the isotope ratios of precipitation vary in space and time and why they correlate with other climate variables like temperature and precipitation. Here, we argue that this behavior is best understood through the lens of radiative transfer, which treats the depletion of atmospheric vapor transport by precipitation as analogous to the attenuation of light by absorption or scattering. Building on earlier work by Siler et al., we introduce a simple model that uses the equations of radiative transfer to approximate the two-dimensional pattern of the oxygen isotope composition of precipitation ( δ p ) from monthly mean hydrologic variables. The model accurately simulates the spatial and seasonal variability in δ p within a state-of-the-art climate model and permits a simple decomposition of δ p variability into contributions from gradients in evaporation and the length scale of vapor transport. Outside the tropics, δ p is mostly controlled by gradients in evaporation, whose dependence on temperature explains the positive correlation between δ p and temperature (i.e., the temperature effect). At low latitudes, δ p is mostly controlled by gradients in the transport length scale, whose inverse relationship with precipitation explains the negative correlation between δ p and precipitation (i.e., the amount effect). This suggests that the temperature and amount effects are both mostly explained by the variability in upstream rainout, but they reflect distinct mechanisms governing rainout at different latitudes. Significance Statement The isotopic composition of precipitation has long been used to make inferences about past climates based on its observed relationship with precipitation in the tropics and with temperature at higher latitudes. These relationships—known as the “amount effect” and “temperature effect,” respectively—have been attributed to many different mechanisms, most of which are thought to operate at either high or low latitudes but not both. Here, we present a unified framework for interpreting the isotope variability that can explain the latitude dependence of the temperature and amount effects despite making no distinction between high and low latitudes. Although our results are generally consistent with certain interpretations of the amount effect, they suggest that the temperature effect is widely misunderstood.

54 ENVIRONMENTAL SCIENCES↗

Round Robin Analysis of Uranium Isotopics on Cotton Swipes Measured Using Microextraction-Based Sampling Versus Conventional Bulk Analysis

A comparison of microextraction sampling methods to directly analyze uranium isotopics on cotton swipes was performed concurrently with traditional bulk-processing methods. For the microextraction sampling approach, two different detection platforms were evaluated, a quadrupole-based inductively coupled plasma mass spectrometer (ICP-MS) and the liquid sampling-atmospheric pressure glow discharge (LS-APGD) coupled to an Orbitrap mass spectrometer. Results presented from this innovative sampling approach (i.e., microextraction) are compared with a more traditional approach employed for analysis of cotton-based environmental swipes, namely bulk ashing/digestion, separation, and subsequent analysis by high-precision multi-collector ICP-MS. Overall, the microextraction approach proved to be a reliable and accurate means to determine isotopic ratios of uranium collected on cotton swipes. The ICP-MS-based detection had relative standard deviations of <0.65% for the major isotopic determinations, whereas the LS-APGD-Orbitrap method had relative standard deviations of <3%. The percent relative difference for the 235 U/ 238 U ratios, in comparison to the expected values, was <1% for ICP-MS and <4% for the microplasma-Orbitrap method. Additionally, the microextraction ICP-MS accurately (<2%) and precisely (<5%) determined the minor isotopic compositions (i.e., 234 U/ 238 U and 236 U/ 238 U).

ICP-MS↗

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

Simulating metagenomic stable isotope probing datasets with MetaSIPSim

DNA-stable isotope probing (DNA-SIP) links microorganisms to their in-situ function in diverse environmental samples. Combining DNA-SIP and metagenomics (metagenomic-SIP) allows us to link genomes from complex communities to their specific functions and improves the assembly and binning of these targeted genomes. However, empirical development of metagenomic-SIP methods is hindered by the complexity and cost of these studies. We developed a toolkit, ‘MetaSIPSim,’ to simulate sequencing read libraries for metagenomic-SIP experiments. MetaSIPSim is intended to generate datasets for method development and testing. To this end, we used MetaSIPSim generated data to demonstrate the advantages of metagenomic-SIP over a conventional shotgun metagenomic sequencing experiment. Through simulation we show that metagenomic-SIP improves the assembly and binning of isotopically labeled genomes relative to a conventional metagenomic approach. Improvements were dependent on experimental parameters and on sequencing depth. Community level G + C content impacted the assembly of labeled genomes and subsequent binning, where high community G + C generally reduced the benefits of metagenomic-SIP. Furthermore, when a high proportion of the community is isotopically labeled, the benefits of metagenomic-SIP decline. Finally, the choice of gradient fractions to sequence greatly influences method performance. Metagenomic-SIP is a valuable method for recovering isotopically labeled genomes from complex communities. We show that metagenomic-SIP performance depends on optimization of experimental parameters. MetaSIPSim allows for simulation of metagenomic-SIP datasets which facilitates the optimization and development of metagenomic-SIP experiments and analytical approaches for dealing with these data.

59 BASIC BIOLOGICAL SCIENCES↗

Challenges in correlating oxygen stable isotope ratios of hydrates on uranium ore concentrates to process waters

Exchange of oxygen stable isotopes (δ 18 O values) between precipitation waters and uranium oxides is governed by thermodynamics or kinetics. It has been assumed that meteoric waters can be related to precipitation waters in uranium ore concentrates and their calcination and reduced uranium oxide products. With this assumption, the δ 18 O values of uranium materials could provide forensic signatures that identify the production history and geolocation of nuclear materials. To further exploit the potential of δ 18 O values in nuclear material analysis, this study examines the oxygen stable isotope exchange in two UOCs, magnesium diuranate (MDU) and sodium diuranate (SDU). MDU and SDU were synthesized from solutions of uranyl nitrate hexahydrate using precipitation waters with unique oxygen isotope compositions. The structures of the MDU and SDU were analyzed using powder X-ray diffraction (p-XRD) and thermal mass loss curves, while the δ 18 O values of waters generated during thermal decomposition were analyzed using a thermogravimetric analyzer coupled to an isotope ratio infrared spectrometer (TGA-IRIS). By p-XRD, the MDU was uniform and amorphous across all syntheses with residual crystalline material incorporated as a minor component. Combined with the TGA results, all of the MDU is likely amorphous MgU 2 O 7 ·3H 2 O with MgO impurities present throughout. In contrast, the SDU synthesis resulted in multiple phases with many samples exhibiting crystalline phases including a combination of Na(UO 2 ) 4 O 2 (OH) 5 ·5H 2 O and Na 2 (UO2) 6 O 4 (OH) 6 ·8H 2 O with a Na 2 U 2 O 7 minor phase. A small fraction of the SDU samples were amorphous with no crystalline XRD peaks observed. Mass loss curves of the SDU samples revealed that the amorphous samples contained inclusions of similar crystalline phases compared to the crystalline materials. The uniformity of the MDU samples enabled highly reproducible measurements of δ 18 O values of the water vapor yielded for two dehydration events at 170 °C and 500 °C. In contrast, the multiphase composition of the SDU samples resulted in poor reproducibility in δ 18 O values. In conclusion, neither system revealed any correlation between the δ 18 O values of precipitation water, and the waters released during dehydration of the UOCs.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Stable isotopes of carbon dioxide (CO2), dissolved inorganic carbon (DIC), water and concentrations of greenhouse gases in a mountainous watershed (Crested Butte, Colorado)

Temperature and precipitation variability in response to climate change affects water cycling of watersheds and can potentially impact water quality, water availability, elemental and molecular fluxes, and biogeochemical processes. Here we report the measurements of light stable isotopes and greenhouse gases analysis to a large multidisciplinary project addressing watershed function. Water hydrogen (H) and oxygen (O) stable isotopes of snow and water saturated soil were measured to constrain source contributions to groundwater and streamflow. In an effort to better constrain existing nitrogen and carbon cycling models in high-altitude ecosystems, carbon dioxide (CO2), nitrous oxide (N2O), methane (CH4) greenhouse gases concentrations and stable isotope signatures of CO2, dissolved inorganic carbon (DIC), and water were measured. This dataset includes one CSV file and one Excel file containing data including stable isotopes of carbon dioxide (CO2), dissolved inorganic carbon (DIC), water and concentrations of greenhouse gases. The CSV and Excel files contain the same information/data but have included both versions for accessibility.

54 ENVIRONMENTAL SCIENCES↗

Water isotope data for the TEMPEST study site, 2023-2026

This dataset contains water isotope (deuterium (dD) and oxygen (d18O)) data from porewater, experimental source water, and aquifer sources from the Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experimental field site in Edgewater, MD. Samples were taken from 2023-2026 and included in file "TEMPEST_Water_Isotope_LANL_2023-2026.csv". Porewater samples were taken from 15cm depth at multiple locations in each experimental plot (i.e., control, freshwater, and saltwater). Water samples were stored in 2 ml amber glass vials with septum caps under refrigeration until analysis. A L2140-i Picarro cavity ringdown spectrometer connected to an A0211 Picarro vaporization module was used to run water samples. Standards (United States Geological Survey (USGS) 47 and 48) were used to check instrument accuracy during each run of samples. Post-processing codes were run to calculate isotopic values from raw data. Reported isotope data is post-processed. Raw data CSV files from the Picarro were processed using a Python script and output as excel files containing data calibrated to Vienna Standard Mean Ocean Water (VSMOW). Standardization is based on USGS47 and USGS48 standards that are measured before and after every 5-10 unknowns. Every measurement is comprised of 10 injections. Processing involved discarding the first 4 injections due to a known memory effect. Raw means of the last 6 injections are taken for each measurement and then corrected from the linear calibration relationship of the USGS standards expected vs measured values to obtain corrected compositions relative to VSMOW. Reported isotope data are corrected mean results.

Aquifer↗

Fitting $\overline{\nu}$ for minor Pu isotopes

After successful fitting of prompt $\overline{\nu}$ for 235 U, 238 U, and 239 Pu(n,f) using CGMF, we will move on to the minor plutonium isotopes. Minor isotopes pose a greater challenge both because there is less data available and we do not, by default, have parametrizations in CGMF already. To mitigate these challenges— and provide consistency within CGMF—we will take a stepped approach to the optimization. Continuing from the 239 Pu work, we will then fit 241 Pu(n,f) $\overline{\nu}$, where there is also a number of experimental measurements, keeping consistency between the parameters that are included in the calculation for 239 Pu and 241 Pu. With these parametrizations settled, we can consistently optimize 240 Pu(n,f) $\overline{\nu}$. Following that step, we will move on to 242 Pu(n,f) (and increasing neutron number) and 238 Pu(n,f) (and decreasing neutron number). By including the fissioning systems in this manner, we should be able to minimize the unknown parameters in CGMF. We will possibly also be able to develop systematics for the CGMF input parameters along the Pu isotopic chain. This work can serve as a guide to broadening the reactions available in CGMF. In this short report, we first give an example of how we have updated CGMF to include 240 Pu(n,f) and 242 Pu(n,f), keeping consistency with the current 239 Pu and 241 Pu calculations, but without rigorous optimization (Sec. 2). Then, we will shown in Section 3 what experimental data exist for the various isotopes to provide some insight into why 241 Pu and 239 Pu are used as anchor points.

07 ISOTOPE AND RADIATION SOURCES↗

Oxidation of Dissolved Tetravalent Selenium by Birnessite: Se Isotope Fractionation and the Effects of pH and Birnessite Structure

Redox reactions control the mobility and bioavailability of selenium (Se) in biogeochemical systems, both modern and ancient. Se isotope ratio measurements (e.g., 82 Se/ 76 Se) have been developed to enhance understanding of biogeochemical transformations and transport of Se. Stable isotope ratios of many elements are known to be powerful indicators of redox reactions, and shifts in 82 Se/ 76 Se have been observed for Se reduction reactions. However, Se isotope shifts caused by naturally relevant oxidation reactions have not been published. Here, we report Se isotope fractionation factors for oxidation of Se(IV) by birnessite. Experiments were conducted at pH = 4.0 and 5.5, with two types of birnessite of contrasting composition at two concentrations of suspended birnessite. The results are consistent with a single 82 Se/ 76 Se fractionation factor, for all times during all experiments, of 0.99767 (±0.0035 2 s.d.). Expressed as ε, the fractionation is 2.33‰ (±0.08‰).

58 GEOSCIENCES↗

Deep Eutectic Solvents as Candidates for Lithium Isotope Enrichment

Nuclear fusion is a phenomenon that is well known within the nuclear physics community as a viable option for alternative energy as many natural gases and fossil fuels are phased out of commercial use. Deuterium and tritium fusion reactions are currently the leading candidates for nuclear fusion, with a major limiting factor being a means to produce tritium on an industrial scale. Lithium-6 is a well-known isotope that can produce tritium and helium following a fission reaction with a neutron. Unfortunately, the lithium-6 enrichment methods are limited to the COLEX process, which leaves behind an alarming amount of mercury waste as a potential environmental contaminant. Deep eutectic solvents are believed to be a potential alternative to lithium isotope separations due to the ease of generation, in addition to the minimum environmental waste generated when these solvents are employed. Previous studies have suggested that deep eutectic solvents are capable of separating lithium isotopes by utilizing a 2-thenoyltrifluoroacetone and trioctylphosphine oxide system that can biphasically react with a buffered solution containing lithium chloride. This system displays a separation factor of 1.068, which when compared to the 1.054 separation within the COLEX process, makes it a potential candidate for lithium-6/7 separation. Within this study, we investigate this system in comparison to two newly synthesized deep eutectic solvents and find that within these acetylacetone-based systems, little isotopic separation is observed. We investigate these systems both experimentally and computationally, showing the different lithium cation affinities, in addition to proposing how the electron-donating or -withdrawing nature can influence these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

COMBLE-ISLAS water isotopes in precipitation (COMBLEISLASISO)

During the measurement period, precipitation was sampled on daily to sub-daily basis with a sampling kit consiting of a clear plastic box (60x40x40 cm) mounted to a ground structure. Daily sampling lasted from 22 Feb to 24 Mar 2020. At a fixed time of day (10 UTC), samples were collected and the sampling box cleaned for the next sample. Additionally, during intense observations periods (IOPs) announced by ISLAS, ARMS scientists increased sampling frequency to sub-daily sampling. During the campaign period, 2 IOPs were conducted, with in total 12 samples taken. IOP1 lasted from 27 Feb 10 to 02 Mar 2020, and IOP2 lasted from 12 Mar to 14 Mar 2020. Solid precipitation in the box was then melted, transferred to an 8 ml glass vial, sealed and shipped to FARLAB (University of Bergen, Norway) for stable water isotope analysis. Measured stable isotope composition of precipitation samples will be related to conditions at other sampling locations, and at the evaporation site to inform about conservation of water isotope quantities. In the period from 22 Feb to 24 Mar, 23 daily samples were collected at 10 UTC for stable water isotope analysis. During the entire sampling period, a high variability of precipitation phase was encountered. Most samples were recovered in the form of graupel/snow (12 samples), as rain (7 samples), and the remaining samples fell as graupel, snow, rain or frozen rain. Precipitation amounts varied between <1 mm (26 Feb) and 140 mm (25 Feb) within the sampling box. Furthermore, higher-resolution sampling was conducted during 2 intense observation periods (IOPs). During IOP1, lasting from 27 Feb 10 UTC to 02 Mar 10 UTC, 7 samples were collected, all of them as solid phase precipitation. IOP2 lasted from 12 Mar 10 UTC to 14 Mar 09 UTC, and 5 samples (all as graupel/snow) were collected. Samples were processed according to FARLAB standard measurement procedures. In short, samples were transferred to 1.5 ml glass vials with rubber/PTFE septa (part #548-0907, VWR, USA). An autosampler (A0325, Picarro Inc) transferred ca. 2&micro;l per injection into a high-precision vapourizer (A0211, Picarro Inc, USA) heated to 110&deg;C. After blending with dry N2 (< 5 ppm H2O) the gas mixture was directed into the measurement cavity of a Cavity-Ring Down Spectrometer (L2140-i, Picarro Inc) for about 7 min with a typical water concentration of 20 000 ppm. Memory effects were reduced by two times measuring a vapour mixture at a mixing ratio of 50 000 ppm, obtained from 2 injections of 2 &micro;l for 5 min at the beginning of each new sample vial. Thereafter, another 6 injections of 2 &micro;l per sample were measured individually as described above, and averages of the last 5 injections were used for further processing. Three standards were measured at the beginning and end of each batch, including a drift standard DI2 (&delta;D: -50.72&plusmn;0.73 permil, &delta;18O: -7.63&plusmn;0.10 permil), and for calibration the laboratory standards GLW (&delta;D: -307.79&plusmn;0.75 permil, &delta;18O: -40.02&plusmn;0.07 permil) and EVAP2 (&delta;D: 9.52&plusmn;0.65 permil, &delta;18O: 1.81&plusmn;0.13 permil). A detailed calibration report is included with the final uploaded data set.

54 ENVIRONMENTAL SCIENCES↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

Isotope separation methods and systems

Methods and systems for the separation of isotopes from an aqueous stream are described as can be utilized in one embodiment to remove and recover tritium from contaminated water. Methods include counter-current flow of an aqueous stream on either side of a separation membrane. The separation membrane includes an isotope selective layer (e.g., graphene) and an ion conductive supporting layer (e.g., Nafion®). An electronic driving force encourages passage of isotopes selectively across the membrane to enrich the flow in the isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling Isotope Separation in Electrochemical Lithium Deposition

Naturally occurring Li consists of two stable isotopes, 6 Li with an abundance of about 7.5%, and 7 Li making up the remainder with 92.5%. The development of a 6 Li enrichment technique, in terms of technical reliability and environmental safety to reach 6 Li future requirements, represents a key step in the roadmap for nuclear fusion energy supply worldwide. This paper uses finite element analysis-based models to simulate electrochemical Li isotope separation, which is an attractive method in terms of simplicity, safety, and scalability. In the model, we quantitatively analyze how different electrochemical factors including thermodynamics, charge-transfer kinetics, and diffusivities affect the separation process (separation factor), together with cell parameters, such as cell length and current density. The maximum separation factor of 1.128 could be obtained with the cell under the optimal thermodynamic, kinetic, and diffusive conditions, which is among the highest separation factors ever reported. Furthermore, these results will assist in designing the actual isotope separation setup with large separation factor and appropriate timing for sample collection.

07 ISOTOPE AND RADIATION SOURCES↗

The oxygen stable isotope composition of CRM 125-A UO 2 standard reference material

While there is a clear need for standardized reference materials for analytical calibrations and for inter-laboratory comparisons, there are not currently any for the oxygen stable isotopic composition of uranium oxides. In this paper we summarize the results from four laboratories by seven different methods of oxygen stable isotope analyses using fluorination techniques of CRM 125-A UO 2 Standard Reference Material. We synthesize these data and methods to arrive at a consensus oxygen stable isotope composition for CRM 125-A $δ$ 18 O = -9.63‰ (±0.29‰) VSMOW. We discuss methodological differences between analytical approaches, including furnace vs laser heating, fluorination using BrF 5 or ClF 3 , as well as calibration strategies. We highlight the potential effects of calibration scale compression from single-point calibrations using reference material with $δ$ 18 O values having a large relative difference from the sample being analyzed. We demonstrate how calibration scale compression can yield differences in calibrated $δ$ 18 O values up to ~2‰ for samples with ~20‰ difference from a single reference material, if the calibration slope of different analytical systems differs by 0.1. In conclusion, we suggest the use of liquid water calibration standards sealed in silver capillary tubes for multi-point calibrations of fluorination analysis systems.

07 ISOTOPE AND RADIATION SOURCES↗

Endogenous Production and Vibrational Analysis of Heavy-Isotope-Labeled Peptides from Cyanobacteria

Stable isotope labeling is an extremely useful tool for characterizing the structure, tracing the metabolism, and imaging the distribution of natural products in living organisms using mass-sensitive measurement techniques. In this study, a cyanobacterium was cultured in 15 N/ 13 C-enriched media to endogenously produce labeled, bioactive oligopeptides. The extent of heavy isotope incorporation in these peptides was determined with LC–MS, while the overall extent of heavy isotope incorporation in whole cells was studied with nanoSIMS and AFM-IR. Up to 98 % heavy isotope incorporation was observed in labeled cells. Three of the most abundant peptides, microcystin-LR (MCLR), cyanopeptolin-A (CYPA), and aerucyclamide-A (ACAA), were isolated and further studied with Raman and FTIR spectroscopies and DFT calculations. This revealed several IR and Raman active vibrations associated with functional groups not common in ribosomal peptides, like diene, ester, thiazole, thiazoline, and oxazoline groups, which could be suitable for future vibrational imaging studies. More broadly, this study outlines a simple and relatively inexpensive method for producing heavy-labeled natural products. Finally, manipulating the bacterial culture conditions by the addition of specific types and amounts of heavy-labeled nutrients provides an efficient means of producing heavy-labeled natural products for mass-sensitive imaging studies.

60 APPLIED LIFE SCIENCES↗

Implications of Underground Nuclear Explosion Cavity Evolution for Radioxenon Isotopic Composition

Abstract Isotopic ratios of radioxenons sampled in the atmosphere or subsurface can be used to verify the occurrence of an underground nuclear explosion (UNE). Differences in the half-lives of radioactive xenon precursors and their decay-chain networks produce different time-dependent concentration profiles of xenon isotopes allowing isotopic ratios to be used for tracking UNE histories including estimating the time of detonation. In this study, we explore the potential effects of post-detonation cavity processes: precipitation of iodine precursors, gas seepage, and prompt venting on radioxenon isotopic evolution which influences UNE histories. Simplified analytical models and closed-form solutions yielding a potentially idealized radioactive decay/ingrowth chain in a closed and well-mixed system typically have limited application by not including the partitioning of the radionuclide inventory between a gas phase and rock melt created by the detonation and by ignoring gas transport from the cavity to host rock or ground surface. In reality, either subsurface transport or prompt release that is principally responsible for gas signatures violates the closed-system (or batch-mode) assumption. A closed-form solution representing time-dependent source-term activities is extended by considering the cavity partitioning process, slow seepage, and/or prompt release of gases from the cavity and applied to realistic systems.

Sun, Yunwei (ORCID:0000000194801439)↗