Search NASA⌕ Search

SEARCH · Search NASA

Results for “Importance Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Understanding the Structure and Dynamics of Complex Biomembrane Interactions by Neutron Scattering Techniques

The membrane is one of the key structural materials of biology at the cellular level. Composed predominantly of a bilayer of lipids with embedded and bound proteins, it defines the boundaries of the cell and many organelles essential to life and therefore is involved in almost all biological processes. Membrane-specific interactions, such as drug binding to a membrane receptor or the interactions of an antimicrobial compound with the lipid matrix of a pathogen membrane, are of interest across the scientific disciplines. Herein we present a review, aimed at nonexperts, of the major neutron scattering techniques used in membrane studies: small-angle neutron scattering, neutron membrane diffraction, neutron reflectometry, quasielastic neutron scattering, and neutron spin echo. Neutron scattering techniques are well suited to studying biological membranes. The nondestructive nature of cold neutrons means that samples can be measured for long periods without fear of beam damage from ultraviolet, electron, or X-ray radiation, and neutron beams are highly penetrating, thus offering flexibility in samples and sample environments. Most important is the strong difference in neutron scattering lengths between the two most abundant forms of hydrogen, protium and deuterium. Changing the relative amounts of protium/deuterium in a sample allows the production of a series of neutron scattering data sets, enabling the observation of differing components within complex membrane architectures. This approach can be as simple as using the naturally occurring neutron contrast between different biomolecules to study components in a complex by changing the solution H 2 O/D 2 O ratio or as complex as selectively labeling individual components with hydrogen isotopes. This review presents an overview of each experimental technique with the neutron instrument configuration, related sample preparation and sample environment, and data analysis, highlighted by a special emphasis on using prominent neutron contrast to understand structure and dynamics. This review gives researchers a practical introduction to the often enigmatic suite of neutron beamlines, thereby lowering the barrier to taking advantage of these large-facility techniques to achieve new understandings of membranes and their interactions with other molecules.

59 BASIC BIOLOGICAL SCIENCES↗

MicroPheno: predicting environments and host phenotypes from 16S rRNA gene sequencing using a k-mer based representation of shallow sub-samples

Microbial communities play important roles in the function and maintenance of various biosystems, ranging from the human body to the environment. A major challenge in microbiome research is the classification of microbial communities of different environments or host phenotypes. The most common and cost-effective approach for such studies to date is 16S rRNA gene sequencing. Recent falls in sequencing costs have increased the demand for simple, efficient and accurate methods for rapid detection or diagnosis with proved applications in medicine, agriculture and forensic science. We describe a reference- and alignment-free approach for predicting environments and host phenotypes from 16S rRNA gene sequencing based on k-mer representations that benefits from a bootstrapping framework for investigating the sufficiency of shallow sub-samples. Deep learning methods as well as classical approaches were explored for predicting environments and host phenotypes. A k-mer distribution of shallow sub-samples outperformed Operational Taxonomic Unit (OTU) features in the tasks of body-site identification and Crohn’s disease prediction. Aside from being more accurate, using k-mer features in shallow sub-samples allows (i) skipping computationally costly sequence alignments required in OTU-picking and (ii) provided a proof of concept for the sufficiency of shallow and short-length 16S rRNA sequencing for phenotype prediction. In addition, k-mer features predicted representative 16S rRNA gene sequences of 18 ecological environments, and 5 organismal environments with high macro-F1 scores of 0.88 and 0.87. For large datasets, deep learning outperformed classical methods such as Random Forest and Support Vector Machine.

59 BASIC BIOLOGICAL SCIENCES↗

A requirement for diagnosis of the ionization state in opacity measurements

An accurate independent diagnosis of the temperature and the ionization state of the sample plasmas is important to get a set of well-characterized opacity data in experiment. An analysis of using x-ray scattering was presented for this purpose. Information of the ionization state of the sample plasmas could only be clearly detected when both the Compton and Rayleigh features of the scattering spectra are detectable in one laser shot. Only those plasmas with a few bounded electrons left can provide such kind of scattering spectra. The requirements for using the x-ray scattering as diagnosis are rigorous. Under a radiation field produced by laser-heated hohlraum, only limited number of sample elements can be heated to the ionization state required. Careful design is needed to achieve an x-ray scattering experiment. This work can be helpful to establish a diagnostic flattop for the opacity experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microscale depletion of high abundance proteins in human biofluids using IgY14 immunoaffinity resin: Analysis of human plasma and cerebrospinal fluid

Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 µL) due to low yields stemming from losses caused by nonspecific binding to the column matrix. Additionally, the cost of the depletion media can be prohibitive for larger scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large scale studies. We characterized the performance of a 346 µL column volume micro-scale depletion system, using four different flow rates to determine the most effective depletion conditions for ~6 μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10 mL depletion column served as the control. Results showed depletion efficiency of the micro-scale column increased as flow rate decreased, and that our micro-depletion was reproducible. We found, in an initial application, a 600 µL sample of human cerebral spinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.

59 BASIC BIOLOGICAL SCIENCES↗

Eulerian finite element simulations of the drop weight impact test with a dislocation Density-based continuum model

During a drop weight impact test, the kinetic energy of the falling weight is transferred into the sample resting on the anvil. The plastic deformation in the sample is an important mechanism for the dissipation of the input kinetic energy. We use Eulerian finite element analysis to simulate the deformation and temperature evolution in a 1,3,5-trinitro-1,3,5-triazine (RDX) sample consisting of multiple crystals. In Eulerian finite element simulations, the mesh moves relative to the material. After every change of position between the mesh and the material, the state variables are interpolated to the new mesh position, i.e., advection. In an effort to reduce the advection errors, we use a rate form of a dislocation density-based continuum model by Luscher et al. Here, the simulations predict localization of plastic deformation, and plastic dissipation as a significant source of heat generation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Creating Accurate Methane Emission Inventories through Data-Driven Airborne Survey Strategies

Because natural gas emits less carbon than other fossil fuels, it holds promise as a green energy transition fuel. However, the overall carbon footprint of natural gas is significantly elevated by methane emissions that occur during its production and transmission (Cusworth et al. 2022). Methane “super-emitters,” while comprising only about 1% of sites, are responsible for the majority of oil- and gas-sourced methane emissions, making their detection and mitigation critical in reducing the climate impact of natural gas and in meeting national and global sustainability goals (Sherwin et al. 2024). Yet, despite advancements in detection, significant uncertainties remain regarding the size, frequency, and duration distributions of methane emissions (e.g., Frankenberg et al. 2016, Cusworth et al. 2022, Chen, Sherwin et al. 2022, Conrad et al. 2023, Johnson et al. 2023, Sherwin et al. 2024) underscoring the need for comprehensive emissions inventories segmented by basin across the US. Airborne surveys are well-suited for collecting data to build these comprehensive, basin-level inventories because they allow for extensive spatial coverage, and have the spatial resolution, and the sensitivity to pinpoint individual methane sources. As remote sensing technologies enable rapid basin-scale surveys, it is imperative to establish scientifically and statistically robust standards to generate reliable and actionable emissions inventories. Recent work has shown that differences in airborne sampling strategies, detection technologies, and analysis can lead to large differences between survey conclusions if not correctly accounted for (Chen et al. 2024). This elevates the importance of incorporating proper sampling and analysis techniques when designing a methane emissions monitoring campaign to produce accurate results and facilitate cross-study comparisons. In this paper, we describe a survey strategy designed using the latest conclusions from the literature to align results from different aerial surveys. We identify several sampling and analysis principles, including large sample sizes, balanced sampling across oil and gas production, careful survey area definition, and a unified protocol for analysis, to be vital to producing an unbiased estimate of basin-scale emissions. We present results from a Department of Energy-funded project that deployed this survey strategy in two understudied oil and gas- producing regions in the United States: the Haynesville Basin in Texas and Louisiana, and the Woodford Shale in the Anadarko Basin in Oklahoma.

03 NATURAL GAS↗

An exploration of heterogeneity in supernova type Ia samples

We examine three SNe Type Ia datasets: Union2.1, JLA and Panstarrs to check their consistency using cosmology blind statistical analyses as well as cosmological parameter fitting. We find that the Panstarrs dataset is the most stable of the three to changes in the data, although it does not, at the moment, go to high enough redshifts to tightly constrain the equation of state of dark energy, w . The Union2.1, drawn from several different sources, appears to be somewhat susceptible to changes within the dataset. The JLA reconstructs well for a smaller number of cosmological parameters. At higher degrees of freedom, the dependence of its errors on redshift can lead to varying results between subsets. Panstarrs is inconsistent with the other two datasets at about 2σ confidence level, and JLA and Union2.1 are about 1σ away from each other. For the Ω{sub 0} {sub m} − w cosmological reconstruction, with no additional data, the 1σ range of values in w for selected subsets of each dataset is two times larger for JLA and Union2.1 as compared to Panstarrs. The range in Ω{sub 0} {sub m} for the same subsets remains approximately similar for all three datasets. We find that although there are differences in the fitting and correction techniques used in the different samples, the most important criterion is the selection of the SNe, a slightly different SNe selection can lead to noticeably different results both in the purely statistical analysis and in cosmological reconstruction. We note that a single, high quality low redshift sample could help decrease the uncertainties in the result. We also note that lack of homogeneity in the magnitude errors may bias the results and should either be modeled, or its effect neutralized by using other, complementary datasets. A supernova sample with high quality data at both high and low redshifts, constructed from a few surveys to avoid heterogeneity in the sample, and with homogeneous errors, would result in a more robust cosmological reconstruction.

79 ASTRONOMY AND ASTROPHYSICS↗

Tensile testing and fracture mechanism analysis of polyvinyl alcohol nanofibrous webs

Abstract A tensile properties testing study was conducted to understand the influence of thickness, cross‐head speed (speed of testing), gauge length (GL; specimen test length), and sample shape on important tensile properties of polyvinyl alcohol (PVA) nanofiber webs. The effects of each testing parameter on load at break, extension at break, Young's modulus, and tensile stress–strain curve of PVA nanofiber webs are analyzed. The Welch two sample t ‐tests show the significant difference among tested data. Using interaction plots, two‐way analysis of variance, and margin mean plots, the interaction effects among testing parameters have been analyzed. Of all the factors, cross‐head speed, the interaction among GL, and sample thickness (GL: Thickness) and the interaction among GL, testing speed and sample thickness (GL: Speed: Thickness) have significant influence on the tensile properties of PVA nanofiber webs. Moreover, the hypothesized model of mechanism of tensile strain–stress curve of PVA nanofiber webs has been proposed. Based on the model, the tensile strain–stress curve can be split into three stages: linear elastic, partial break up, and complete breakage. This study will provide a better understanding of tensile testing parameters' effects and their interaction effects on the tensile properties of nanowebs.

Lou, Lihua↗

JGI-Trichoderma v1.0

There is a series of Python and bash scripts to parse genomics datasets used to evaluate the coevolution of gene families and the feature importance of gene families using an SVM classifier. - Cover analysis: takes a list of single-copy genes in a set of genomes, aligns and builds the gene trees to determine if two gene families have a signature of covariation with one another. It parses the files to run phykit cover script described here: https://jlsteenwyk.com/PhyKIT/usage/index.html - SVM-classifier: This Python script is an SVM-based genomic classifier designed for biological data analysis. It combines machine learning with feature selection to identify important genomic markers and classify biological samples. Core Functionality: The script uses Support Vector Machines from scikit-learn to classify genomic data, incorporating SelectKBest for automated feature selection and leave-one-out cross-validation for performance assessment. It operates in multiple modes: feature ranking, optimal combination discovery, and sample prediction. Primary Applications: Genomic sample classification and biomarker discovery Feature importance analysis in high-dimensional biological datasets Prediction of sample categories based on genomic profiles Research applications requiring robust classification of biological data Key Advantages: High-dimensional handling: SVMs excel with genomic data's typical high feature-to-sample ratios Integrated feature selection: Reduces noise and computational overhead while identifying key markers Probability estimation: Provides confidence scores essential for biological interpretation Validation robustness: Leave-one-out cross-validation ensures reliable performance metrics Operational flexibility: Multiple analysis modes support different research phases from exploration to prediction

Stecca Steindorff, Andrei [Lawrence Berkeley Natio↗

Identifying Important Ions and Positions in Mass Spectrometry Imaging Data Using CUR Matrix Decompositions

Mass spectrometry imaging enables label-free, high-resolution spatial mapping of the chemical composition of complex, biological samples. Typical experiments require selecting ions and/or positions from the images: ions for fragmentation studies to identify keystone compounds and positions for follow up validation measurements using microdissection or other orthogonal techniques. Unfortunately, with modern imaging machines, these must be selected from an overwhelming amount of raw data. Existing techniques to reduce the volume of data, the most popular of which are principle component analysis and non-negative matrix factorization, have the disadvantage that they return difficult-to-interpret linear combinations of actual data elements. In this work, we show that CX and CUR matrix decompositions can be used directly to address this selection need. CX and CUR matrix decompositions use empirical statistical leverage scores of the input data to provide provably good low-rank approximations of the measured data that are expressed in terms of actual ions and actual positions, as opposed to difficult-to-interpret eigenions and eigenpositions. We show that this leads to effective prioritization of information for both ions and positions. In particular, important ions can be found either by using the leverage scores as a ranking function and using a deterministic greedy selection algorithm or by using the leverage scores as an importance sampling distribution and using a random sampling algorithm; however, selection of important positions from the original matrix performed significantly better when they were chosen with the random sampling algorithm. Also, we show that 20 ions or 40 locations can be used to reconstruct the original matrix to a tolerance of 17% error for a widely studied image of brain lipids; and we provide a scalable implementation of this method that is applicable for analysis of the raw data where there are often more than a million rows and/or columns, which is larger than SVD-based low-rank approximation methods can handle. Lastly, these results introduce the concept of CX/CUR matrix factorizations to mass spectrometry imaging, describing their utility and illustrating principled algorithmic approaches to deal with the overwhelming amount of data generated by modern mass spectrometry imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the importance of the viscosity contrast between the sample solvent plug and the mobile phase and its potential consequences in two-dimensional high-performance liquid chromatography

The effect of solvent viscosity mismatch on elution performance in reversed-phase HPLC was studied using moment analysis. Two conditions were tested: (1) the mobile phase viscosity was less than the injection plug viscosity, and (2) the mobile phase viscosity was greater than the injection plug viscosity. Under the first condition, retention time and elution performance decreased as the viscosity contrast between the mobile phase and injection plug increased. The effect on performance was more marked as the injection volume increased. A decrease in performance of 12% for compounds with retention factors up to 2.8 was apparent even when the viscosity contrast was only 0.165 cP. In the second set of conditions, elution performance was actually observed to increase, by as much as 25% for a 40 {micro}L injection, as the viscosity contrast between the mobile phase and the solute plug increased. No change in the retention factor was observed. This behaviour was attributed to the shape of an injection plug as it enters into the column, whereby a low viscosity plug permeates away from the wall when the column contains a higher viscosity mobile phase, and vice a versa for a high viscosity plug entering a low viscosity mobile phase. At no stage was either a band splitting or shoulders observed with viscosity contrasts up to 1.283 cP, as could have been expected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microscale Isotopic Variation in Uranium Fuel Pellets with Implications for Nuclear Forensics

Until recently, the analysis and identification of nuclear fuel pellets in the context of a nuclear forensics investigation have been mainly focused on macroscopic characteristics, such as fuel pellet dimensions, uranium enrichment, and other reactor-specific features. Here, we report microscale isotopic heterogeneity observed in different fuel pellet fragments that were characterized in situ by nanoscale secondary ion mass spectrometry (NanoSIMS). The materials analyzed include fuel fragments obtained as part of the Collaborative Materials Exercise (CMX-4) organized by the Nuclear Forensics International Technical Working Group (ITWG), as well as a fuel pellet fragment from a commercial power reactor. Although the commercial fuel pellet showed a homogeneous 235 U/ 238 U ratio across the sample (within analytical error), NanoSIMS imaging of the CMX-4 fuel pellet fragments showed distinct microscale variations in the uranium isotopic composition. The average 235 U enrichments were 2.2 and 2.9% for the two samples; however, the measured 235 U/ 238 U ratios varied between 0.0081 and 0.035 (0.79–3.3 atom % 235 U) and between 0.0090 and 0.045 (0.89–4.3 atom % 235 U). The measurement of 236 U in one of the CMX-4 samples suggested the use of at least three uranium oxide powders of different isotopic compositions (“source terms”) in the production of the pellets. These variations were not detected using the conventional bulk, macroscopic techniques applied to these materials. Furthermore, our study highlights the importance of characterizing samples on the microscale for heterogeneities that would otherwise be overlooked and demonstrates the potential use of NanoSIMS in guiding further nuclear forensic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The combined force field-sampling problem in simulations of disordered amyloid-β peptides

Molecular dynamics simulations of intrinsically disordered proteins (IDPs) can provide high resolution structural ensembles if the force field is accurate enough and if the simulation sufficiently samples the conformational space of the IDP with the correct weighting of sub-populations. Here, we investigate the combined force field–sampling problem by testing a standard force field as well as newer fixed charge force fields, the latter specifically motivated for better description of unfolded states and IDPs, and comparing them with a standard temperature replica exchange (TREx) protocol and a non-equilibrium Temperature Cool Walking (TCW) sampling algorithm. The force field and sampling combinations are used to characterize the structural ensembles of the amyloid-beta peptides Aβ42 and Aβ43, which both should be random coils as shown recently by experimental nuclear magnetic resonance (NMR) and 2D Förster resonance energy transfer (FRET) experiments. The results illustrate the key importance of the sampling algorithm: while the standard force field using TREx is in poor agreement with the NMR J-coupling and nuclear Overhauser effect and 2D FRET data, when using the TCW method, the standard and optimized protein-water force field combinations are in very good agreement with the same experimental data since the TCW sampling method produces qualitatively different ensembles than TREx. Lastly, we also discuss the relative merit of the 2D FRET data when validating structural ensembles using the different force fields and sampling protocols investigated in this work for small IDPs such as the Aβ42 and Aβ43 peptides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new method for quantifying 64 Cu in nuclear debris samples

Quantifying 64 Cu in post-detonation nuclear debris samples can provide important diagnostic information regarding the structural materials used within a nuclear device. However, this task is challenging due to the weak gamma emissions associated with the decay of 64 Cu, its short half-life (12.701 h), and the presence of interfering fission product radioisotopes. Large quantities of debris sample are generally needed to accurately quantify 64 Cu, which can be problematic in sample-limited scenarios where other radiometric analyses are required. Herein, we present a new method for the separation of 64 Cu from solutions of mixed fission products and demonstrate the quantification of its activity through use of gas-flow proportional beta counting. Here, the new method was validated through a series of rigorous tests and was shown to improve the detection limit of 64 Cu by over two orders of magnitude, from 2.5 × 10 6 to 1.3 × 10 4 atoms/sample for 100 min measurements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Large-Scale Multiplexed Quantitative Discovery Proteomics Enabled by the Use of an O-18-Labeled “Universal” Reference Sample

Quantitative comparison of protein abundances across a relatively large number of patient samples is an important challenge for clinical proteomic applications. Herein we describe a dual-quantitation strategy that allows the simultaneous integration of complementary label-free and stable isotope labeling based approaches without increasing the number of LC-MS analyses. The approach utilizes a stable isotope 18O-labeled “universal” reference sample as a comprehensive set of internal standards spiked into each individually processed unlabeled patient sample. The quantitative data are based on both the direct 16O-MS intensities for label-free quantitation and the 16O/18O isotopic peptide pair ratios that compare each patient sample to the identical labeled reference. The effectiveness of this dual-quantitation approach for large scale quantitative proteomics is demonstrated by the application to a set of 38 clinical plasma samples from surviving and non-surviving severe burn patients. With the coupling of immunoaffinity depletion, cysteinyl-peptide enrichment based fractionation, high resolution LC-MS measurements, and the dual-quantitation approach, a total of 318 proteins were confidently quantified with at least two peptides and 263 proteins were quantified by both approaches. The strategy also enabled a direct comparison between the two approaches with the labeling approach showing significantly better precision in quantitation while the label-free approach resulted in more protein identifications. The relative abundance differences determined by the two approaches also show strong correlation. Finally, the dual-quantitation strategy allowed us to identify more candidate protein biomarkers, illustrating the complementary nature of the two quantitative methods.

59 BASIC BIOLOGICAL SCIENCES↗

ASX O-ring Life Testing Using a LAW High Bound Melter Feed Simulant (Final Report)

The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is planning to utilize an Isolok sampler to sample the contents of the Low Activity Waste (LAW) and High Level Waste (HLW) Melter Feed Preparation Vessels (MFPV) as well as the contents of the LAW Concentrate Receipt Vessel (CRV). Over the course of testing, it has been recognized that the long term reliability of the o-ring seals in the Isolok sampler are an important component in sampling. The Isolok sampler will be collecting samples of melter feed that contain a high percentage of highly abrasive particles which can impact the life of the o-rings. Although o-ring life in normal service is typically several hundred thousand cycles (such as in the air cylinders and other non-abrasive environments), no data are available for the life of the o-ring seals in this abrasive environment. To address this concern, a Test Exception was issued to perform testing to determine whether the o-rings in an Isolok sampler will continue to function through one year of projected HLW MFPV sampler operation, or approximately 7,000 sampler piston cycles. This final report provides results of the o-ring testing that was performed with the ASX sampler.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of Bulk Chemical Composition on Relative Sensitivity Factors for 55Mn/52Cr by SIMS: Implications for the 53Mn-53Cr Chronometer

The {sup 53}Mn-{sup 53}Cr systematics of meteorite samples provide an important high resolution chronometer for early solar system events. Accurate determination of the initial abundance of {sup 53}Mn ({tau}{sub 1/2} = 3.7 Ma) by secondary ion mass spectrometry (SIMS) is dependent on properly correcting for differing ion yields between Mn and Cr by use of a relative sensitivity factor (RSF). Ideal standards for SIMS analysis should be compositionally and structurally similar to the sample of interest. However, previously published Mn-Cr studies rely on few standards (e.g., San Carlos olivine, NIST 610 glass) despite significant variations in chemical composition. We investigate a potential correlation between RSF and bulk chemical composition by determining RSFs for {sup 55}Mn/{sup 52}Cr in 11 silicate glass and mineral standards (San Carlos olivine, Mainz glasses KL2-G, ML3B-G, StHs6/80-G, GOR128-G, BM90/21-G, and T1-G, NIST 610 glass, and three LLNL pyroxene-composition glasses). All standards were measured on the Cameca ims-3f ion microprobe at LLNL, and a subset were also measured on the Cameca ims-1270 ion microprobe at the Geological Survey of Japan. The standards cover a range of bulk chemical compositions with SiO{sub 2} contents of 40-71 wt.%, FeO contents of 0.05-20 wt.% and Mn/Cr ratios between 0.4 and 58. We obtained RSF values ranging from 0.83 to 1.15. The data obtained on the ims-1270 ion microprobe are within {approx}10% of the RSF values obtained on the ims-3f ion microprobe, and the RSF determined for San Carlos olivine (0.86) is in good agreement with previously published data. The typical approach to calculating an RSF from multiple standard measurements involves making a linear fit to measured {sup 55}Mn/{sup 52}Cr versus true {sup 55}Mn/{sup 52}Cr. This approach may be satisfactory for materials of similar composition, but fails when compositions vary significantly. This is best illustrated by the {approx}30% change in RSF we see between glasses with similar Mn/Cr ratios but variable Fe and Na content. We are developing an approach that uses multivariate analysis to evaluate the importance of different chemical components in controlling the RSF and predict the RSF of unknowns when standards of appropriate composition are not available. Our analysis suggests that Fe, Si, and Na are key compositional factors in these silicate standards. The RSF is positively correlated with Fe and Si and negatively correlated with Na. Work is currently underway to extend this analysis to a wider range of chemical compositions and to evaluate the variability of RSF on measurements obtained by NanoSIMS.

58 GEOSCIENCES↗

THE SMALL ISOLATED GAS-RICH IRREGULAR DWARF (SIGRID) GALAXY SAMPLE: DESCRIPTION AND FIRST RESULTS

Using an optically unbiased selection process based on the HIPASS neutral hydrogen survey, we have selected a sample of 83 spatially isolated, gas-rich dwarf galaxies in the southern hemisphere with cz between 350 and 1650 km s{sup -1}, and with R-band luminosities and H I masses less than that of the Small Magellanic Cloud. The sample is an important population of dwarf galaxies in the local universe, all with ongoing star formation, and most of which have no existing spectroscopic data. We are measuring the chemical abundances of these galaxies, using the integral-field spectrograph on the Australian National University 2.3 m telescope, the Wide-Field Spectrograph. This paper describes our survey criteria and procedures, lists the survey sample, and reports on initial observations.

79 ASTRONOMY AND ASTROPHYSICS↗