Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inlet diffusers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Solar collector performance evaluation with the NASA-Lewis solar simulator-results for an all-glass-evacuated-tubular selectively-coated collector with a diffuse reflector

A solar collector was tested in a solar simulator for inlet temperatures of temperatures of 70 to 200 F, flux levels of 230 and rate of 7 lb/(hr)(sq. ft), and incident angles of 0 deg, 33 deg, and 52 deg. Test results plotted in a form suggested by analysis indicate a very low heat loss coefficient. The collector shows excellent performance on an all-day performance basis, and also for conditions corresponding to temperatures required in solar Rankine systems and/or for low flux level radiation.

Simon, F.↗

Methane oxidation in Saanich Inlet during summer stratification

Saanich Inlet, British Columbia, an fjord on the southeast coast of Vancouver Island, typically stratifies in summer, leading to the formation of an oxic-anoxic interface in the water column and accumulation of methane in the deep water. The results of methane concentration measurements in the water column of the inlet at various times throughout the summer months in 1983 are presented. Methane gradients and calculated diffusive fluxes across the oxic-anoxic interface increased as the summer progressed. Methane distribution and consumption in Saanich Inlet were studied in more detail during August 1986. At this time, a typical summer stratification with an oxic-anoxic interface around 140 m was present. At the interface, steep gradients in nutrient concentrations, bacterial abundance and methane concentration were observed. Methane oxidation was detected in the aerobic surface waters and in the anaerobic deep layer, but highest rates occurred in a narrow layer at the oxic-anoxic interface. Estimated methane oxidation rates were suffcient to consume 100 percent of the methane provided by diffusive flux from the anoxic layer. Methane oxidation is thus a mechanism whereby atmospheric flux from anoxic waters is minimized.

Ward, B. B.↗

Supersonic Test of the 10-Inch Bifurcated Two-Stage Supersonic Inlet (BTSSI)

Experimental results from testing of a novel supersonic inlet model in NASA Glenn Research Center's 10- by 10-foot supersonic wind tunnel are presented. The patented inlet concept, called Two-Stage Supersonic Inlet (TSSI), incorporates a large cavity, or throat slot, in the supersonic diffuser intended to enhance the stability of the normal shock. The present embodiment of the concept is a bifurcated twin-duct) design. During the course of testing an unusual 'semi-started' mode of operation was encountered. The inlet was able to spill up to 30 percent of the captured airstream without fully expelling the normal shock. In this mode, the total pressure recovery dropped approximately 6 percent without increasing steady-state distortion. Dynamic instrumentation at the cowl lip station indicates the semi-start mode may be a series of unstart/restart cycles with frequency ranging from 0.2 to 20 Hz. Engine face total pressure measurements indicate a modest impact due to this event. However, since the current test article does not have a representative subsonic diffuser (and is in fact separated), it is unclear how this mode of operation would effect an engine. Further investigation of this phenomenon is required before it is fully understood. Prior testing of the TSSI concept allowed extension of fully started inlet operation to regions of significantly reduced supply flow without reducing recovery. The test article was a smaller scale than the present test and was a single duct design. In the present test, the expanded range of stable operation with high recovery was not realized.

Carlin, C. M.↗

Pressure Recovery, Drag, and Subcritical Stability Characteristics of Three Conical Supersonic Diffusers at Stream Mach Numbers from 1.7 to 2.0

A study of a 20 degree and a 25 degree half-angle high mass-flow ratio conical supersonic inlet was made on a 16-inch ram jet in the 8- by 6-foot supersonic tunnel. A greater range of stable subcritical operation was obtained with the low mass-flow ratio inlets; a greater range was obtained with the 25 degree than with the 20 degree half-angle low mass-flow ratio inlet. The high mass-flow ratio inlet had the least drag.

DIFFUSERS, SUPERSONIC↗

Experimental and analytical study of a conically diffused flow with a nearly separated boundary layer

Turbulence measurements were obtained in the nearly separated flow in a 13 deg total angle of divergence conical diffuser coupled to a constant area tailpipe. Air at 207 newtons per square centimeter and 308 K provided an inlet velocity of about 51 meters per second at an inlet unit Reynolds number of 63.7 million per meter. Very high longitudinal turbulence intensities accompanied the diffusion process with peak values approaching 40 percent when normalized by the local centerline velocity. Predictions of the pressure recovery coefficient using a mixing length concept were good in the early stages of diffusion. In the latter stages of diffusion satisfactory predictions of the pressure recovery were obtained with an empirical method.

Boldman, D. R.↗

Low-speed Investigation of a Semisubmerged Air Scoop with and Without Boundary-layer Suction

A preliminary low-speed investigation has been made of an air scoop submerged one-half the inlet height in a depression on the surface of a simulated fuselage. Boundary-layer suction was used on the steep approach ramp to improve the internal flow. A 6-degree-included-angle diffuser with an area ratio of 1.9:1 was located behind the inlet in the model. Most of the tests were conducted with an initial turbulent boundary layer believed to approximate that which would occur on the forward part of a fuselage. A few tests were made with a boundary layer about 2.5 times the thickness of the original boundary layer to determine the effect of moving the inlet further rearward on the fuselage. The effects of suction-slot location and slot width were determined and a few tests with area suction were made. The maximum quantity of suction flow was about 15 percent of the inlet flow at an inlet-velocity ratio of 0.6.

Pierpont, P Kenneth↗

Turbulence characteristics of compressor discharge flows

Turbulence measurements were conducted in a large gas turbine engine (JT9D) at the entrance to the diffuser duct, joining the compressor discharge to the combustor inlet. Hot film probe and hot wire probe measurements were obtained at temperatures from 450K (350F) (idle) to 608K (635F) (rich approach). At I.D. (25 percent span) and mid-span locations, the turbulence intensity increased slightly from 6 + or - percent at idle condition to 7 or - 1 percent at rich approach. At O.D. (75 percent span) the turbulent intensity increased more rapidly, from 7.5 + or - 0.5 percent at idle to 15 + or - 0.5 percent at rich approach. The spectra showed turbulent energy distributed uniformly over a 0.1 to 5 KHz bandwidth (down 3db) at all operating conditions, corresponding to random turbulence with velocity wave lengths of 2 cm to 1 meter travelling at the mean velocity of 100 m/sec. Tests results are given in tables and graphs.

Grant, H. P.↗

Theoretical analysis of various thrust-augmentation cycles for turbojet engines

The results of analytical studies of tail-pipe-burning, water-injection, and bleedoff methods of thrust augmentation are presented that provide an insight into the operating characteristics of these augmentation methods and summarizes the performance that may be obtained when applied to a typical turbojet engine. A brief description of the principles of operation of each augmentation method is given, together with curves that illustrate the effects of the principal design and operating variables of the augmentation system on the thrust and the liquid consumption of the engine. The necessity of designing tail-pipe burners with a low burner-inlet velocity, a low burner drag, and a high diffuser efficiency in order to obtain a high thrust augmentation and to minimize the loss in engine performance during nonburning operation is illustrated.

Lundin, Bruce T↗

Prediction of Turbulent Diffusing Flows Using FUN3D

The FUN3D code was used to perform Reynolds-averaged Navier-Stokes (RANS) simulations to compute subsonic flow in an S-duct diffuser and transonic flow in a two-dimensional diffuser using the Speziale-Sarkar-Gatski/Launder-Rodi-Reece (SSG/LRR) Reynolds stress model (RSM). For comparison purposes, additional simulations were run with the one-equation Spalart-Allmaras (SA) and the two-equation Menter Shear-Stress Transport (SST) turbulence models. Each model was run with and without the quadratic constitutive relation (QCR) for computing the turbulent stresses. It was shown that the simulations that utilized the RSM had better overall predictions of the diffusive flow fields compared to the simulations that utilized the one and two equation turbulence models.

Inlet Distortion↗

Performance of supersonic scoop inlets

A brief summary is made of the performance of a series of variable-geometry type scoop inlets investigated at the Lewis Laboratory on a model of the X-3 airplane fuselage. Data are presented for a range of inlet mass-flow ratios over a Mach number range from 0 to 2 and from 0 degrees to 12 degrees angle of attack. Rounded-lip inlets are found to give satisfactory performance to a Mach number of 1.5. Use of sharp rather than blunt lip configurations is shown to provide considerable gains in available thrust at Mach number 2.0 but penalize take-off performance to the extent that auxiliary air intakes may be required. No one inlet type was found to be superior over the entire range of operating variables. Thus, the choice of a specific inlet design will be influenced by structural and mechanical as well as aerodynamic considerations.

DIFFUSERS, SUPERSONIC↗

Enhanced Performance of Streamline-Traced External-Compression Supersonic Inlets

A computational design study was conducted to enhance the aerodynamic performance of streamline-traced, external-compression inlets for Mach 1.6. Compared to traditional external-compression, two-dimensional and axisymmetric inlets, streamline-traced inlets promise reduced cowl wave drag and sonic boom, but at the expense of reduced total pressure recovery and increased total pressure distortion. The current study explored a new parent flowfield for the streamline tracing and several variations of inlet design factors, including the axial displacement and angle of the subsonic cowl lip, the vertical placement of the engine axis, and the use of porous bleed in the subsonic diffuser. The performance was enhanced over that of an earlier streamline-traced inlet such as to increase the total pressure recovery and reduce total pressure distortion.

performance↗

Enhanced Performance of Streamline-Traced External-Compression Supersonic Inlets

A computational design study was conducted to enhance the aerodynamic performance of streamline-traced, external-compression inlets for Mach 1.6. The current study explored a new parent flowfield for the streamline tracing and several variations of inlet design factors, including the axial displacement and angle of the subsonic cowl lip, the vertical placement of the engine axis, and the use of porous bleed in the subsonic diffuser. The performance was enhanced over that of an earlier streamline-traced inlet such as to increase the total pressure recovery and reduce total pressure distortion

performance↗

An improved design method and experimental performance of two dimensional curved wall diffusers

A computer design program was developed to incorporate the suction slots in solving the potential flow equations with prescribed boundary conditions. Using the contour generated from this program two Griffith diffusers were tested having area ratios AR = 3 and 4. The inlet Reynolds number ranged from 600,000 to 7 million. It was found that the slot suction required for metastable operation depends on the sidewall suction applied. Values of slot suction of 8% of the inlet flow rate was required for AR = 4 with metastable condition, provided that enough sidewall suction was applied. For AR = 3, the values of slot suction was about 25% lower than those required for AR = 4. For nearly all unseparated test runs, the effectiveness was 100% and the exit flow was uniform. In addition to the Griffith diffusers, dump and cusp diffusers of comparable area ratios were built and tested. The results obtained from these diffusers were compared with those of the Griffith diffusers. Flow separation occurred in all test runs with the dump and cusp diffusers.

Yang, T.↗

Performance of an All-internal Conical Compression Inlet with Annular Throat Bleed at Mach Number 5.0

An all-internal conical compression inlet with annular bleed at the throat was investigated at Mach 5.0 and zero angle of attack. The minimum contraction ratio of the supersonic diffuser, coincident with a mass-flow ratio of 1.0, was determined to be 0.084 as compared with the isentropic contraction ratio of 0.04 at Mach 5.0. The over-all inlet performance was very sensitive to the amount of annular bleed at the throat because of the extensive boundary layer. For example, the critical recovery varied from 41 percent with 6-percent bleed to 59 percent with 25-percent bleed. Decreasing the spacing between the supersonic and subsonic diffusers increased the critical mass-flow ratio but reduced the range of subcritical mass-flow regulation. A constant-area section was required ahead of the subsonic diffuser in order to obtain reasonable performance. An inlet-engine net-thrust analysis indicated that the optimum performance occurred with from 20- to 25-percent bleed, depending on how the bypassed air was handled.

Stitt, Leonard E.↗

Analytical correlation of centrifugal compressor design geometry for maximum efficiency with specific speed

Centrifugal compressor performance was examined analytically to determine optimum geometry for various applications as characterized by specific speed. Seven specific losses were calculated for various combinations of inlet tip-exit diameter ratio, inlet hub-tip diameter ratio, blade exit backsweep, and inlet-tip absolute tangential velocity for solid body prewhirl. The losses considered were inlet guide vane loss, blade loading loss, skin friction loss, recirculation loss, disk friction loss, vaneless diffuser loss, and vaned diffuser loss. Maximum total efficiencies ranged from 0.497 to 0.868 for a specific speed range of 0.257 to 1.346. Curves of rotor exit absolute flow angle, inlet tip-exit diameter ratio, inlet hub-tip diameter ratio, head coefficient and blade exit backsweep are presented over a range of specific speeds for various inducer tip speeds to permit rapid selection of optimum compressor size and shape for a variety of applications.

Galvas, M. R.↗

Modeling the Deterioration of Engine and Low Pressure Compressor Performance During a Roll Back Event Due to Ice Accretion

The main focus of this study is to apply a computational tool for the flow analysis of the engine that has been tested with ice crystal ingestion in the Propulsion Systems Laboratory (PSL) of NASA Glenn Research Center. A data point was selected for analysis during which the engine experienced a full roll back event due to the ice accretion on the blades and flow path of the low pressure compressor. The computational tool consists of the Numerical Propulsion System Simulation (NPSS) engine system thermodynamic cycle code, and an Euler-based compressor flow analysis code, that has an ice particle melt estimation code with the capability of determining the rate of sublimation, melting, and evaporation through the compressor blade rows. Decreasing the performance characteristics of the low pressure compressor (LPC) within the NPSS cycle analysis resulted in matching the overall engine performance parameters measured during testing at data points in short time intervals through the progression of the roll back event. Detailed analysis of the fan-core and LPC with the compressor flow analysis code simulated the effects of ice accretion by increasing the aerodynamic blockage and pressure losses through the low pressure compressor until achieving a match with the NPSS cycle analysis results, at each scan. With the additional blockages and losses in the LPC, the compressor flow analysis code results were able to numerically reproduce the performance that was determined by the NPSS cycle analysis, which was in agreement with the PSL engine test data. The compressor flow analysis indicated that the blockage due to ice accretion in the LPC exit guide vane stators caused the exit guide vane (EGV) to be nearly choked, significantly reducing the air flow rate into the core. This caused the LPC to eventually be in stall due to increasing levels of diffusion in the rotors and high incidence angles in the inlet guide vane (IGV) and EGV stators. The flow analysis indicating compressor stall is substantiated by the video images of the IGV taken during the PSL test, which showed water on the surface of the IGV flowing upstream out of the engine, indicating flow reversal, which is characteristic of a stalled compressor.

Veres, Joseph P.↗

Modeling the Deterioration of Engine and Low Pressure Compressor Performance During a Roll Back Event Due to Ice Accretion

The main focus of this study is to apply a computational tool for the flow analysis of the engine that has been tested with ice crystal ingestion in the Propulsion Systems Laboratory (PSL) of NASA Glenn Research Center. A data point was selected for analysis during which the engine experienced a full roll back event due to the ice accretion on the blades and flow path of the low pressure compressor. The computational tool consists of the Numerical Propulsion System Simulation (NPSS) engine system thermodynamic cycle code, and an Euler-based compressor flow analysis code, that has an ice particle melt estimation code with the capability of determining the rate of sublimation, melting, and evaporation through the compressor blade rows. Decreasing the performance characteristics of the low pressure compressor (LPC) within the NPSS cycle analysis resulted in matching the overall engine performance parameters measured during testing at data points in short time intervals through the progression of the roll back event. Detailed analysis of the fan-core and LPC with the compressor flow analysis code simulated the effects of ice accretion by increasing the aerodynamic blockage and pressure losses through the low pressure compressor until achieving a match with the NPSS cycle analysis results, at each scan. With the additional blockages and losses in the LPC, the compressor flow analysis code results were able to numerically reproduce the performance that was determined by the NPSS cycle analysis, which was in agreement with the PSL engine test data. The compressor flow analysis indicated that the blockage due to ice accretion in the LPC exit guide vane stators caused the exit guide vane (EGV) to be nearly choked, significantly reducing the air flow rate into the core. This caused the LPC to eventually be in stall due to increasing levels of diffusion in the rotors and high incidence angles in the inlet guide vane (IGV) and EGV stators. The flow analysis indicating compressor stall is substantiated by the video images of the IGV taken during the PSL test, which showed water on the surface of the IGV flowing upstream out of the engine, indicating flow reversal, which is characteristic of a stalled compressor.

Jorgenson, Philip C. E.↗

Performance characteristics of two annular dump diffusers using suction-stabilized vortex flow control

Test results are described for two abrupt area change annular diffusers with provisions for maintaining suction stabilized toroidal vortices at the area discontinuity. Both diffusers had an overall area ratio of 4.0 with the prediffuser area ratio being 1.18 for diffuser A and 1.4 for diffuser B. Performance was evaluated at near atmospheric pressure and temperature for a range of inlet Mach numbers from 0.18 to 0.41 and suction rates from 0 to 18%. Static pressure recovery improved significantly as the suction rate was increased to approximately 11%. Results obtained with diffuser A were superior to that obtained with diffuser B. Flat radial profiles of exit velocity were not obtained since the flow showed preferential hub or tip attachment at moderate suction rates. At high suction rates the diffuser exit flow became circumferentially nonuniform and unstable.

Juhasz, A. J.↗