Search NASA⌕ Search

SEARCH · Search NASA

Results for “LC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

The influence of calcium and pH on growth in primary roots of Zea mays

We investigated the interaction of Ca2+ and pH on root elongation in Zea mays L. cv. B73 x Missouri 17 and cv. Merit. Seedlings were raised to contain high levels of Ca2+ (HC, imbibed and raised in 10 mM CaCl2) or low levels of Ca2+ (LC, imbibed and raised in distilled water). In HC roots, lowering the pH (5 mM MES/Tris) from 6.5 to 4.5 resulted in strong, long-lasting growth promotion. Surprisingly, increasing the pH from 6.5 to 8.5 also resulted in strong growth promotion. In LC roots acidification of the medium (pH 6.5 to 4.5) resulted in transient growth stimulation followed by a gradual decline in the growth rate toward zero. Exposure of LC roots to high pH (pH shift from 6.5 to 8.5) also promoted growth. Addition of EGTA resulted in strong growth promotion in both LC and HC roots. The ability of EGTA to stimulate growth appeared not to be related to H+ release from EGTA upon Ca2+ chelation since, 1) LC roots showed a strong and prolonged response to EGTA, but only a transient response to acid pH, and 2) promotion of growth by EGTA was observed in strongly buffered solutions. We also examined the pH dependence of the release of 45Ca2+ from roots of 3-day-old seedlings grown from grains imbibed in 45Ca2+. Release of 45Ca2+ from the root into agar blocks placed on the root surface was greater the more acidic the pH of the blocks. The results indicate that Ca2+ may be necessary for the acid growth response in roots.

Non-NASA Center↗

Complementary Paired G4FETs as Voltage-Controlled NDR Device

It is possible to synthesize a voltage-controlled negative-differential-resistance (NDR) device or circuit by use of a pair of complementary G4FETs (four-gate field-effect transistors). [For more information about G4FETs, please see the immediately preceding article]. As shown in Figure 1, the present voltage-controlled NDR device or circuit is an updated version of a prior NDR device or circuit, known as a lambda diode, that contains a pair of complementary junction field-effect transistors (JFETs). (The lambda diode is so named because its current-versus- voltage plot bears some resemblance to an upper-case lambda.) The present version can be derived from the prior version by substituting G4FETs for the JFETs and connecting both JFET gates of each G4FET together. The front gate terminals of the G4FETs constitute additional terminals (that is, terminals not available in the older JFET version) to which one can apply control voltages VN and VP. Circuits in which NDR devices have been used include (1) Schmitt triggers and (2) oscillators containing inductance/ capacitance (LC) resonant circuits. Figure 2 depicts such circuits containing G4FET NDR devices like that of Figure 1. In the Schmitt trigger shown here, the G4FET NDR is loaded with an ordinary inversion-mode, p-channel, metal oxide/semiconductor field-effect transistor (inversion-mode PMOSFET), the VN terminal of the G4FET NDR device is used as an input terminal, and the input terminals of the PMOSFET and the G4FET NDR device are connected. VP can be used as an extra control voltage (that is, a control voltage not available in a typical prior Schmitt trigger) for adjusting the pinch-off voltage of the p-channel G4FET and thereby adjusting the trigger-voltage window. In the oscillator, a G4FET NDR device is loaded with a conventional LC tank circuit. As in other LC NDR oscillators, oscillation occurs because the NDR counteracts the resistance in the tank circuit. The advantage of this G4FET-NDR LC oscillator over a conventional LC NDR oscillator is that one can apply a time-varying signal to one of the extra control input terminals (VN or VP) to modulate the conductance of the NDR device and thereby amplitude-modulate the output signal.

Mojarradi, Mohammad↗

Operational Lessons Learned from the Ares I-X Flight Test

The Ares I-X flight test, launched in 2009, is the first test of the Ares I crew launch vehicle. This development flight test evaluated the flight dynamics, roll control, and separation events, but also provided early insights into logistical, stacking, launch, and recovery operations for Ares I. Operational lessons will be especially important for NASA as the agency makes the transition from the Space Shuttle to the Constellation Program, which is designed to be less labor-intensive. The mission team itself comprised only 700 individuals over the life of the project compared to the thousands involved in Shuttle and Apollo missions; while missions to and beyond low-Earth orbit obviously will require additional personnel, this lean approach will serve as a model for future Constellation missions. To prepare for Ares I-X, vehicle stacking and launch infrastructure had to be modified at Kennedy Space Center's Vehicle Assembly Building (VAB) as well as Launch Complex (LC) 39B. In the VAB, several platforms and other structures designed for the Shuttle s configuration had to be removed to accommodate the in-line, much taller Ares I-X. Vehicle preparation activities resulted in delays, but also in lessons learned for ground operations personnel, including hardware deliveries, cable routing, transferred work and custodial paperwork. Ares I-X also proved to be a resource challenge, as individuals and ground service equipment (GSE) supporting the mission also were required for Shuttle or Atlas V operations at LC 40/41 at Cape Canaveral Air Force Station. At LC 39B, several Shuttle-specific access arms were removed and others were added to accommodate the in-line Ares vehicle. Ground command, control, and communication (GC3) hardware was incorporated into the Mobile Launcher Platform (MLP). The lightning protection system at LC 39B was replaced by a trio of 600-foot-tall towers connected by a catenary wire to account for the much greater height of the vehicle. Like Shuttle, Ares I-X will be stacked on a MLP and rolled out to the pad on a Saturn-era crawler-transporter. While Ares I-X was only held in place by the four hold-down posts on its aft skirt during rollout, a new vehicle stabilization system (VSS) attached to the vertical service structure kept the vehicle from undue swaying prior to launch at the pad, LC 39B. Following the launch, the flight test vehicle first stage was recovered with the aid of new parachutes resized to accommodate the five-segment-long first stage, which had a much greater length and mass than the Shuttle s reusable solid rocket boosters. After splashdown, recovery divers exercised extra care when handling the first stage to ensure that the flight data recorders in the fifth segment simulator were not damaged by exposure to sea water. The data recovered from the Ares I-X flight test will be very valuable in verifying the predicted environments and models used to design the vehicle. Lessons learned from Ares I-X will be shared with the Ares Projects through written and verbal reports and through integration of mission team members into the Project workforce.

Davis, Stephan R.↗

4D Light Field Imaging System Using Programmable Aperture

Complete depth information can be extracted from analyzing all angles of light rays emanated from a source. However, this angular information is lost in a typical 2D imaging system. In order to record this information, a standard stereo imaging system uses two cameras to obtain information from two view angles. Sometimes, more cameras are used to obtain information from more angles. However, a 4D light field imaging technique can achieve this multiple-camera effect through a single-lens camera. Two methods are available for this: one using a microlens array, and the other using a moving aperture. The moving-aperture method can obtain more complete stereo information. The existing literature suggests a modified liquid crystal panel [LC (liquid crystal) panel, similar to ones commonly used in the display industry] to achieve a moving aperture. However, LC panels cannot withstand harsh environments and are not qualified for spaceflight. In this regard, different hardware is proposed for the moving aperture. A digital micromirror device (DMD) will replace the liquid crystal. This will be qualified for harsh environments for the 4D light field imaging. This will enable an imager to record near-complete stereo information. The approach to building a proof-ofconcept is using existing, or slightly modified, off-the-shelf components. An SLR (single-lens reflex) lens system, which typically has a large aperture for fast imaging, will be modified. The lens system will be arranged so that DMD can be integrated. The shape of aperture will be programmed for single-viewpoint imaging, multiple-viewpoint imaging, and coded aperture imaging. The novelty lies in using a DMD instead of a LC panel to move the apertures for 4D light field imaging. The DMD uses reflecting mirrors, so any light transmission lost (which would be expected from the LC panel) will be minimal. Also, the MEMS-based DMD can withstand higher temperature and pressure fluctuation than a LC panel can. Robotics need near complete stereo images for their autonomous navigation, manipulation, and depth approximation. The imaging system can provide visual feedback

Bae, Youngsam↗

Variable-pulse-shape pulsed-power accelerator

A variable-pulse-shape pulsed-power accelerator is driven by a large number of independent LC drive circuits. Each LC circuit drives one or more coaxial transmission lines that deliver the circuit's output power to several water-insulated radial transmission lines that are connected in parallel at small radius by a water-insulated post-hole convolute. The accelerator can be impedance matched throughout. The coaxial transmission lines are sufficiently long to transit-time isolate the LC drive circuits from the water-insulated transmission lines, which allows each LC drive circuit to be operated without being affected by the other circuits. This enables the creation of any power pulse that can be mathematically described as a time-shifted linear combination of the pulses of the individual LC drive circuits. Therefore, the output power of the convolute can provide a variable pulse shape to a load that can be used for magnetically driven, quasi-isentropic compression experiments and other applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

L-carnitine protects against nickel-induced neurotoxicity by maintaining mitochondrial function in Neuro-2a cells

Mitochondrial dysfunction is thought to be a part of the mechanism underlying nickel-induced neurotoxicity. L-carnitine (LC), a quaternary ammonium compound biosynthesized from the amino acids lysine and methionine in all mammalian species, manifests its neuroprotective effects by improving mitochondrial energetics and function. The purpose of this study was to investigate whether LC could efficiently protect against nickel-induced neurotoxicity. Here, we exposed a mouse neuroblastoma cell line (Neuro-2a) to different concentrations of nickel chloride (NiCl{sub 2}) (0.25, 0.5, 1, and 2 mM) for 24 h, or to 0.5 mM and 1 mM NiCl{sub 2} for various periods (0, 3, 6, 12, or 24 h). We found that nickel significantly increased the cell viability loss and lactate dehydrogenase (LDH) release in Neuro-2a cells. In addition, nickel exposure significantly elevated reactive oxygen species (ROS) and malondialdehyde (MDA) levels, disrupted the mitochondrial membrane potential ({Delta}{Psi}{sub m}), reduced adenosine-5'-triphosphate (ATP) concentrations and decreased mitochondrial DNA (mtDNA) copy numbers and mtRNA transcript levels. However, all of the cytotoxicities and mitochondrial dysfunctions that were triggered by nickel were efficiently attenuated by pretreatment with LC. These protective effects of LC may be attributable to its role in maintaining mitochondrial function in nickel-treated cells. Our results suggest that LC may have great pharmacological potential in protecting against the adverse effects of nickel in the nervous system.

60 APPLIED LIFE SCIENCES↗

Near-Field Passive Wireless Sensor for High-Temperature Metal Corrosion Monitoring

This work focuses on the fabrication and evaluation of a passive wireless sensor for the monitoring of the temperature and corrosion of a metal material at high temperatures. An inductor–capacitor (LC) resonator sensor was fabricated through the screen printing of Ag-based inks on dense polycrystalline Al 2 O 3 substrates. The LC design was modeled using the ANSYS HFSS modeling package, with the LC passive wireless sensors operating at frequencies from 70 to 100 MHz. The wireless response of the LC was interrogated and received by a radio frequency signal generator and spectrum analyzer at temperatures from 50 to 800 °C in real time. The corrosion kinetics of the Cu 110 was characterized through thermogravimetric (TGA) analysis and microscopy images, and the oxide thickness growth was then correlated to the wireless sensor signal under isothermal conditions at 800 °C. The results showed that the wireless signal was consistent with the corrosion kinetics and temperature, indicating that these two characteristics can be further deconvoluted in the future. In addition, the sensor also showed a magnitude- and frequency-dependent response to crack/spallation events in the oxide corrosion layer, permitting the in situ wireless identification of these catastrophic events on the metal surface at high temperatures.

36 MATERIALS SCIENCE↗

Computational Chemistry-Guided Design of Selective Chemoresponsive Liquid Crystals Using Pyridine and Pyrimidine Functional Groups

Computational chemistry-guided designs of chemoresponsive liquid crystals (LCs) with pyridine or pyrimidine groups that bind to metal-cation-functionalized surfaces to provide improved selective responses to targeted vapor species (dimethylmethylphosphonate (DMMP)) over nontargeted species (water) are reported. The LC designs against experiments are tested by synthesizing 4-(4-pentyl-phenyl)-pyridine and 5-(4-pentyl-phenyl)-pyrimidine and quantifying LC responses to DMMP and water. Consistent with the computations, pyridine-containing LCs bind to metal-cation-functionalized surfaces too strongly to permit a response to either DMMP or water whereas pyrimidine-containing LCs undergo a surface-driven orientational transition in response to DMMP without interference from water. The computation predictions are not strongly dependent on assumptions regarding the degree of coordination of the metal ions but are limited in their ability to predict LC responses when using cations with mostly empty d orbitals. Overall, this work identifies a promising new class of chemoresponsive LCs based on pyrimidine that exhibits enhanced tolerance to water, a result that is important because water is a ubiquitous and particularly challenging chemical interferent in chemical sensing strategies based on LCs. The work also provides further evidence of the transformative utility of computational chemistry methods to design LC materials that exhibit selective orientational responses in specific chemical environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid Crystal‐Based Detection of Antigens with ELISA Sensitivity

Abstract A highly sensitive label‐free liquid crystal (LC)‐based technique is presented for detecting Immunoglobulin G (IgG) antigens used to uncover viral infections. The effectiveness, sensitivity, and selectivity of this detection method is demonstrated with goat IgG antigen at concentrations as low as 100 pg ml −1 , which is comparable to the sensitivity of the current enzyme‐linked immunosorbent assay (ELISA). The sensor is fabricated by decorating a transmission electron microscopy grid immobilized glass surfaces with antibodies; the target antigen is detected by a liquid crystal suspended onto the grid. This is different from previous methods where the antigen is detected either at the LC‐aqueous interface or in an LC sandwich cell with an antibody/antigen‐decorated substrate. This new approach has advantages such as easy sample preparation, higher sensitivity, and better storage capabilities. Binding the target antigen to the antibody results in a reorientation of the LC director that is detected optically. In addition to demonstrating the sensitivity, the physical principle of the detection is also discussed. This technique may apply to detect virtually any antigen of interest.

36 MATERIALS SCIENCE↗

Control of the Folding Dynamics of Self-Reconfiguring Magnetic Microbots Using Liquid Crystallinity

Reconfigurable microdevices are being explored in a range of contexts where their life-like abilities to move and change shape are important. While much work has been done to control the motion of these microdevices by engineering their geometry and composition, little is known about their dynamics in complex fluid environments with non-Newtonian rheology. Here in this paper, it is shown how the actuation dynamics of reconfigurable microdevices made by assembly of patchy magnetic microcubes, which are referred to as “microbots,” can be modulated by their interactions with the anisotropic viscoelastic environment of a liquid crystal (LC). The free energy arising from the elastic strain of LC and formation of topological defects around the microbots influences their folding dynamics, which can be tuned by tailoring both the far-field orientation of the LC and the local ordering of the LC at the microbot surfaces. These findings represent a first step toward establishing a general set of design rules to control the dynamics of microbots using complex anisotropic fluids.

36 MATERIALS SCIENCE↗

Evaluation of Density-Functional Tight-Binding Methods for Simulation of Protic Molecular Ion Pairs

In this work, we benchmark the accuracy of the density-functional tight-binding (DFTB) method, namely the long-range corrected second-order (LC-DFTB2) and third-order (DFTB3) models, for predicting energetics of imidazolium-based ionic liquid (IL) ion pairs. We compare the DFTB models against popular density functionals such as LC-ωPBE and B3LYP, using ab initio domain-based local pair-natural orbital coupled cluster (DLPNO-CC) energies as reference. Calculations were carried out in the gas phase, as well as in aqueous solution using implicit solvent methods. We find that the LC-DFTB2 model shows excellent performance in the gas phase and agrees well with reference energies in implicit solvent, often outperforming DFTB3 predictions for complexation energetics. Our study identifies a range of opportunities for use of the LC-DFTB method and quantifies its sensitivity to protonation states and the types of chemical interactions between ion pairs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strongly Chiral Liquid Crystals in Nanoemulsions

We report Liquid crystal (LC) emulsions represent a class of confined soft matter that exhibit exotic internal organizations and size-dependent properties, including responses to chemical and physical stimuli. Past studies have explored micrometer-scale LC emulsion droplets but little is known about LC ordering within submicrometer-sized droplets. This paper reports experiments and simulations that unmask the consequences of confinement in nanoemulsions on strongly chiral LCs that form bulk cholesteric and blue phases (BPs). A method based on light scattering is developed to characterize phase transitions of LCs within the nanodroplets. For droplets with a radius to the pitch ratio (R v /p 0 ) as small as 2/3, the BP-to-cholesteric transition is substantially suppressed, leading to a threefold increase of the BP temperature interval relative to bulk behavior. Complementary simulations align with experimental findings and reveal the dominant role of chiral elastic energy. For R v /p 0 ≈ to 1/3, a single LC phase forms below the clearing point, with simulations revealing the new configuration to contain a τ -1/2 disclination that extends across the nanodroplet. These findings are discussed in the context of mechanisms by which polymer networks stabilize BPs and, more broadly, for the design of nanoconfined soft matter.

42 ENGINEERING↗

Lightcone effective Hamiltonians and RG flows

We introduce a prescription for an effective lightcone (LC) Hamiltonian that includes the effects of zero modes, focusing on the case of Conformal Field Theories (CFTs) deformed by relevant operators. We display how the prescription resolves a number of issues with LC quantization, including i) the apparent non-renormalization of the vacuum, ii) discrepancies in critical values of bare parameters in equal-time vs LC quantization, and iii) an inconsistency at large N in CFTs with simple AdS duals. We describe how LC quantization can drastically simplify Hamiltonian truncation methods applied to some large N CFTs, and discuss how the prescription identifies theories where these simplifications occur. We demonstrate and check our prescription in a number of examples.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High precision beam steering using a liquid crystal spatial light modulator

Liquid crystal spatial light modulators (LCSLMs) are novel phase modulation devices. Due to the dielectric properties of the orientation layer, the orientation layer has a voltage division effect on the driving voltage. A more effective analysis of the relationship between the driving voltage and phase modulation properties of LCSLMs is needed, as well as improved beam steering accuracy. In this paper, we establish an electrical model of an LCSLM, and propose a method for quantitatively calculating the liquid crystal (LC) layer voltage. This differential iterative method based on nonlinear least squares is used to analyze the LC molecular directors. Considering the thickness of the orientation layer, we calculate the LC director distribution and the voltage division effect of the LC layer, obtaining a more accurate electro-optic characteristic curve of the LCSLM, and verify the calculations by experiment. Experimentally, the average beam pointing error of the LCSLM was 0.0098° at 532 nm, representing a significant improvement of the beam steering accuracy.

42 ENGINEERING↗

Column properties and flow profiles of a flat, wide column for high-pressure liquid chromatography

The design and the construction of a pressurized, flat, wide column for high-performance liquid chromatography (HPLC) are described. This apparatus, which is derived from instruments that implement over-pressured thin layer chromatography, can carry out only uni-dimensional chromatographic separations. However, it is intended to be the first step in the development of more powerful instruments that will be able to carry out two-dimensional chromatographic separations, in which case, the first separation would be a space-based separation, LC{sup x}, taking place along one side of the bed and the second separation would be a time-based separation, LC{sup t}, as in classical HPLC but proceeding along the flat column, not along a tube. The apparatus described consists of a pressurization chamber made of a Plexiglas block and a column chamber made of stainless steel. These two chambers are separated by a thin Mylar membrane. The column chamber is a cavity which is filled with a thick layer (ca. 1 mm) of the stationary phase. Suitable solvent inlet and outlet ports are located on two opposite sides of the sorbent layer. The design allows the preparation of a homogenous sorbent layer suitable to be used as a chromatographic column, the achievement of effective seals of the stationary phase layer against the chamber edges, and the homogenous flow of the mobile phase along the chamber. The entire width of the sorbent layer area can be used to develop separations or elute samples. The reproducible performance of the apparatus is demonstrated by the chromatographic separations of different dyes. This instrument is essentially designed for testing detector arrays to be used in a two-dimensional LC{sup x} x LC{sup t} instrument. The further development of two-dimension separation chromatographs based on the apparatus described is sketched.

36 MATERIALS SCIENCE↗

Silver-mediated separations: A comprehensive review on advancements of argentation chromatography, facilitated transport membranes, and solid-phase extraction techniques and their applications

The use of silver(I) ions in chemical separations, also known as argentation separations, is a powerful approach for the selective separation and analysis of many natural and synthetic organic compounds. In this review, a comprehensive discussion of the most common argentation separation techniques, including argentation-liquid chromatography (Ag-LC), argentation-gas chromatography (Ag-GC), argentation-facilitated transport membranes (Ag-FTMs), and argentation-solid phase extraction (Ag-SPE) is provided. For each of these techniques, notable advancements, optimized separations, and innovative applications are discussed. The review begins with an explanation of the fundamental chemistry underlying argentation separations, mainly the reversible π-complexation between silver(I) ions and carbon-carbon double bonds. Within Ag-LC, the use of silver(I) ions in thin-layer chromatography, high-performance liquid chromatography, as well as preparative LC are explored. This discussion focuses on how silver(I) ions are employed in the stationary and mobile phase to separate unsaturated compounds. For Ag-GC and Ag-FTMs, different silver compounds and supporting media are discussed, often with relation to olefin-paraffin separations. Ag-SPE has been widely employed for the selective extraction of unsaturated compounds from complex matrices in sample preparation. This comprehensive review of Ag-LC, Ag-GC, Ag-FTMs, and Ag-SPE techniques emphasizes the immense potential of argentation separations in separations science and serves as a valuable resource for researchers seeking to learn, optimize, and utilize argentation separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemoradiation Therapy for Potentially Resectable Gastric Cancer: Clinical Outcomes Among Patients Who Do Not Undergo Planned Surgery

Purpose: We retrospectively analyzed treatment outcomes among resectable gastric cancer patients treated preoperatively with chemoradiation therapy (CRT) but rendered ineligible for planned surgery because of clinical deterioration or development of overt metastatic disease. Methods and Materials: Between 1996 and 2004, 39 patients with potentially resectable gastric cancer received preoperative CRT but failed to undergo surgery. At baseline clinical staging, 33 (85%) patients had T3-T4 disease, and 27 (69%) patients had nodal involvement. Most patients received 45 Gy of radiotherapy with concurrent 5-fluorouracil-based chemotherapy. Twenty-one patients underwent induction chemotherapy before CRT. Actuarial times to local control (LC), distant control (DC), and overall survival (OS) were calculated by the Kaplan-Meier method. Results: The cause for surgical ineligibility was development of metastatic disease (28 patients, 72%; predominantly peritoneal, 18 patients), poor performance status (5 patients, 13%), patient/physician preference (4 patients, 10%), and treatment-related death (2 patients, 5%). With a median follow-up of 8 months (range, 1-95 months), actuarial 1-year LC, DC, and OS were 46%, 12%, and 36%, respectively. Median LC and OS were 11.0 and 10.1 months, respectively. Conclusions: Patients with potentially resectable gastric cancer treated with preoperative CRT are found to be ineligible for surgery principally because of peritoneal progression. Patients who are unable to undergo planned surgery have outcomes comparable to that of patients with advanced gastric cancer treated with chemotherapy alone. CRT provides durable LC for the majority of the remaining life of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Impact of Tumor Expression of Erythropoietin Receptors and Erythropoietin on Clinical Outcome of Esophageal Cancer Patients Treated With Chemoradiation

Background: To investigate the impact of tumor erythropoietin receptors (Epo-R) and erythropoietin (Epo) expression in 64 patients with Stage III esophageal cancer receiving or not receiving erythropoietin during chemoradiation. Materials and Methods: The impact of tumor Epo-R expression, Epo expression, and 10 additional factors (age, Karnofsky-Performance-Score [KPS], tumor length, T and N stage, histology and grading, hemoglobin during radiotherapy, erythropoietin administration, surgery) on overall survival (OS) and locoregional control (LC) was evaluated. Results: Improved OS was associated with low ({<=}20%) Epo expression (p = 0.049), KPS >80 (p 0.008), T3 stage (p = 0.010), hemoglobin {>=}12 g/dL (p < 0.001), and surgery (p = 0.010). Erythropoietin receptor expression showed a trend (p = 0.09). Locoregional control was associated with T stage (p = 0.005) and hemoglobin (p < 0.001), almost with erythropoietin administration (p = 0.06). On multivariate analyses, OS was associated with KPS (p = 0.045) and hemoglobin (p = 0.032), LC with hemoglobin (p < 0.001). Patients having low expression of both Epo-R and Epo had better OS (p = 0.003) and LC (p = 0.043) than others. Two-year OS was nonsignificantly better (p = 0.25) in patients with low Epo-R expression receiving erythropoietin (50%) than in those with higher Epo-R expression receiving erythropoietin (21%), low Epo-R expression/no erythropoietin administration (29%), or higher Epo-R expression/no erythropoietin administration (18%). Two-year LC rates were, respectively, 65%, 31%, 26%, and 29% (p = 0.20). Results for Epo expression were similar. Conclusions: Higher Epo-R expression or Epo expression seemed to be associated with poorer outcomes. Patients with low expression levels receiving erythropoietin seemed to do better than patients with higher expression levels or not receiving erythropoietin. The data need to be confirmed in a larger series of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗