Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOADING RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Implementation of Fiber Substructuring Into Strain Rate Dependent Micromechanics Analysis of Polymer Matrix Composites

A research program is in progress to develop strain rate dependent deformation and failure models for the analysis of polymer matrix composites subject to impact loads. Previously, strain rate dependent inelastic constitutive equations developed to model the polymer matrix were incorporated into a mechanics of materials based micromechanics method. In the current work, the micromechanics method is revised such that the composite unit cell is divided into a number of slices. Micromechanics equations are then developed for each slice, with laminate theory applied to determine the elastic properties, effective stresses and effective inelastic strains for the unit cell. Verification studies are conducted using two representative polymer matrix composites with a nonlinear, strain rate dependent deformation response. The computed results compare well to experimentally obtained values.

Goldberg, Robert K.↗

The influence of crack closure on fatigue crack growth thresholds in 2024-T3 aluminum alloy

Crack opening loads were determined in load-shedding fatigue crack growth threshold tests on 2024-T3 aluminum alloy at stress ratios R of -2, -1, 0, 0.33, 0.5, and 0.7. The effects of load-shedding procedure and rate were investigated. Values of threshold Delta-K were found to vary significantly with R, whereas values of threshold effective Delta-K did not. That is, the variation of threshold Delta-K with R was almost completely explained by accounting for the measured variation in crack opening load behavior with R. The load-shedding guidelines of ASTM Test Method for Measurement of Fatigue Crack Growth (E 647) produced a threshold Delta-K value for R = 0.7 that was in agreement with the value determined using a procedure that should minimize closure effects. At both R = 0 and R = 0.7, high load-shedding rates produced high values of threshold Delta-K caused by large closure effects.

Phillips, Edward P.↗

Frequency and load ratio effects on critical strain energy release rate Gc thresholds of graphite/epoxy composites

Graphite/epoxy composite laminates of T300/BP907 and AS6/HST-7 were axial-tension fatigue tested. Tests were conducted at 5 and 10 Hz, and at loading ratios of R = 0.1 and R = 0.5. Edge delamination was monitored as a function of number of fatigue cycles by monitoring stiffness reduction during fatigue testing. Delamination was confirmed and documented using dye-enhanced X-ray and optical photography. Critical strain energy release rates were then calculated. The composites delaminated readily, with loading ratio having a significant influence. Frequency effects were negligible.

Adams, Donald F.↗

A Method for Calculating Strain Energy Release Rates in Preliminary Design of Composite Skin/Stringer Debonding Under Multi-Axial Loading

Three simple procedures were developed to determine strain energy release rates, G, in composite skin/stringer specimens for various combinations of unaxial and biaxial (in-plane/out-of-plane) loading conditions. These procedures may be used for parametric design studies in such a way that only a few finite element computations will be necessary for a study of many load combinations. The results were compared with mixed mode strain energy release rates calculated directly from nonlinear two-dimensional plane-strain finite element analyses using the virtual crack closure technique. The first procedure involved solving three unknown parameters needed to determine the energy release rates. Good agreement was obtained when the external loads were used in the expression derived. This superposition technique was only applicable if the structure exhibits a linear load/deflection behavior. Consequently, a second technique was derived which was applicable in the case of nonlinear load/deformation behavior. The technique involved calculating six unknown parameters from a set of six simultaneous linear equations with data from six nonlinear analyses to determine the energy release rates. This procedure was not time efficient, and hence, less appealing. A third procedure was developed to calculate mixed mode energy release rates as a function of delamination lengths. This procedure required only one nonlinear finite element analysis of the specimen with a single delamination length to obtain a reference solution for the energy release rates and the scale factors. The delamination was extended in three separate linear models of the local area in the vicinity of the delamination subjected to unit loads to obtain the distribution of G with delamination lengths. This set of sub-problems was Although additional modeling effort is required to create the sub- models, this local technique is efficient for parametric studies.

Krueger, Ronald↗

Roll plus maneuver load alleviation control system designs for the active flexible wing wind-tunnel model

Three designs for controlling loads while rolling for the Active Flexible Wing (AFW) are discussed. The goal is to provide good roll control while simultaneously limiting the torsion and bending loads experienced by the wing. The first design uses Linear Quadratic Gaussian/Loop Transfer Recovery (LQG/LTR) modern control methods to control roll rate and torsional loads at four different wing locations. The second design uses a nonlinear surface command function to produce surface position commands as a function of current roll rate and commanded roll rate. The final design is a flutter suppression control system. This system stabilizes both symmetric and axisymmetric flutter modes of the AFW.

Moore, Douglas B.↗

Evaluation of the Edge Crack Torsion (ECT) Test for Mode 3 Interlaminar Fracture Toughness of Laminated Composites

An analytical and experimental investigation was carried out on G40-800/R6376 graphite epoxy laminates to evaluate the Edge Crack Torsion (ECT) test as a candidate for a standard Mode 3 interlaminar fracture toughness test for laminated composites. The ECT test consists of a (90/(+/- 45)(sub 3)/(+/- 45)(sub 3)/90))(sub s) laminate with a delamination introduced by a non-adhesive film at the mid-plane along one edge and loaded in a special fixture to create torsion along the length of the laminate. Dye penetrate enhanced X-radiograph of failed specimens revealed that the delamination initiated at the middle of the specimen length and propagated in a self similar manner along the laminate mid-plane. A three-dimensional finite element analysis was performed that indicated that a pure Mode 3 delamination exists at the middle of specimen length away from both ends. At the ends near the loading point a small Mode 2 component exists. However, the magnitude of this Mode 2 strain energy release rate at the loading point is small compared to the magnitude of Mode 3 component in the mid-section of the specimen. Hence, the ECT test yielded the desired Mode 3 delamination. The Mode 3 fracture toughness was obtained from a compliance calibration method and was in good agreement with the finite element results. Mode 2 End-Notched Flexure (ENF) tests and Mode 1 Double Cantilever Beam (DCB) tests were also performed for the same composite material. The Mode 1 fracture toughness was much smaller than both the Mode 2 and Mode 3 fracture toughness. The Mode 2 fracture toughness was found to be 75% of the Mode 3 fracture toughness.

Li, Jian↗

A Simplified Approach for the Rapid Generation of Transient Heat-Shield Environments

A simplified approach has been developed whereby transient entry heating environments are reliably predicted based upon a limited set of benchmark radiative and convective solutions. Heating, pressure and shear-stress levels, non-dimensionalized by an appropriate parameter at each benchmark condition are applied throughout the entry profile. This approach was shown to be valid based on the observation that the fully catalytic, laminar distributions examined were relatively insensitive to altitude as well as velocity throughout the regime of significant heating. In order to establish a best prediction by which to judge the results that can be obtained using a very limited benchmark set, predictions based on a series of benchmark cases along a trajectory are used. Solutions which rely only on the limited benchmark set, ideally in the neighborhood of peak heating, are compared against the resultant transient heating rates and total heat loads from the best prediction. Predictions based on using two or fewer benchmark cases at or near the trajectory peak heating condition, yielded results to within 5-10 percent of the best predictions. Thus, the method provides transient heating environments over the heat-shield face with sufficient resolution and accuracy for thermal protection system design and also offers a significant capability to perform rapid trade studies such as the effect of different trajectories, atmospheres, or trim angle of attack, on convective and radiative heating rates and loads, pressure, and shear-stress levels.

Wurster, Kathryn E.↗

SRB attrition rate study of the aft skirt due to water impact cavity collapse loading

A methodology was presented so that realistic attrition prediction could aid in selecting an optimum design option for minimizing the effects of updated loads on the Space Shuttle Solid Rocket Booster (SRB) aft skirt. The updated loads resulted in water impact attrition rates greater than 10 percent for the aft skirt structure. Adding weight to reinforce the aft skirt was undesirable. The refined method treats the occurrences of the load distribution probabilistically, radially and longitudinally, with respect to the critical structural response.

Crockett, C. D.↗

Test-Free Fracture Toughness

Computational simulation results can give the prediction of damage growth and progression and fracture toughness of composite structures. The experimental data from literature provide environmental effects on the fracture behavior of metallic or fiber composite structures. However, the traditional experimental methods to analyze the influence of the imposed conditions are expensive and time consuming. This research used the CODSTRAN code to model the temperature effects, scaling effects and the loading effects of fiberbraided composite specimens with and without fiber-optic sensors on the damage initiation and energy release rates. The load-displacement relationship and fracture toughness assessment approach is compared with the test results from literature and it is verified that the computational simulation, with the use of established material modeling and finite element modules, adequately tracks the changes of fracture toughness and subsequent fracture propagation for any fiberbraided composite structure due to the change of fiber orientations, presence of large diameter optical fibers, and any loading conditions.

Minnetyan, Levon↗

Test-Free Fracture Toughness

Computational simulation results can give the prediction of damage growth and progression and fracture toughness of composite structures. The experimental data from literature provide environmental effects on the fracture behavior of metallic or fiber composite structures. However, the traditional experimental methods to analyze the influence of the imposed conditions are expensive and time consuming. This research used the CODSTRAN code to model the temperature effects, scaling effects and the loading effects of fiber/braided composite specimens with and without fiber-optic sensors on the damage initiation and energy release rates. The load-displacement relationship and fracture toughness assessment approach is compared with the test results from literature and it is verified that the computational simulation, with the use of established material modeling and finite element modules, adequately tracks the changes of fracture toughness and subsequent fracture propagation for any fiber/braided composite structure due to the change of fiber orientations, presence of large diameter optical fibers, and any loading conditions.

Minnetyan, Levon↗

Performance of computer-optimized tapered-roller bearings to 2.4 million DN

The performance of 120.65 mm bore high speed design tapered roller bearings was investigated at shaft speeds to 20,000 rpm under combined thrust and radial load. The test bearing design was computer optimized for high speed operation. Temperature distribution and bearing heat generation were determined as a function of shaft speed, radial and thrust loads, lubricant flow rates, and lubricant inlet temperature. The roller bearing operated successfully at shaft speeds up to 20,000 rpm under heavy thrust and radial loads. Cup cooling was effective in decreasing the high cup temperatures to levels equal to the cone temperature.

Parker, R. J.↗

Load biaxiality and fracture - Synthesis and summary

The question of load biaxiality strongly affecting almost all of the characteristics of brittle fracture behavior of a cracked body is investigated. Results of research published piecemeal over the years by the authors have shown that the stress and displacement fields, the elastic strain energy density, and the maximum shear stress near the crack tip are all altered by loads applied parallel to the crack, as are the angle of initial crack extension, the strain energy of the entire body, the fracture load, and the rate of fatigue crack growth. A synthesis and summary of this research is presented showing the shortcomings inherent in both Griffith's global energy rate theory for crack instability and Irwin's local crack-tip stress intensity theory for fracture toughness. In both theories only the tensile load perpendicular to the crack influences fracture behavior of the body.

Eftis, J.↗

Mechanotransduction and the functional response of bone to mechanical strain

Mechanotransduction plays a crucial role in the physiology of many tissues including bone. Mechanical loading can inhibit bone resorption and increase bone formation in vivo. In bone, the process of mechanotransduction can be divided into four distinct steps: (1) mechanocoupling, (2) biochemical coupling, (3) transmission of signal, and (4) effector cell response. In mechanocoupling, mechanical loads in vivo cause deformations in bone that stretch bone cells within and lining the bone matrix and create fluid movement within the canaliculae of bone. Dynamic loading, which is associated with extracellular fluid flow and the creation of streaming potentials within bone, is most effective for stimulating new bone formation in vivo. Bone cells in vitro are stimulated to produce second messengers when exposed to fluid flow or mechanical stretch. In biochemical coupling, the possible mechanisms for the coupling of cell-level mechanical signals into intracellular biochemical signals include force transduction through the integrin-cytoskeleton-nuclear matrix structure, stretch-activated cation channels within the cell membrane, G protein-dependent pathways, and linkage between the cytoskeleton and the phospholipase C or phospholipase A pathways. The tight interaction of each of these pathways would suggest that the entire cell is a mechanosensor and there are many different pathways available for the transduction of a mechanical signal. In the transmission of signal, osteoblasts, osteocytes, and bone lining cells may act as sensors of mechanical signals and may communicate the signal through cell processes connected by gap junctions. These cells also produce paracrine factors that may signal osteoprogenitors to differentiate into osteoblasts and attach to the bone surface. Insulin-like growth factors and prostaglandins are possible candidates for intermediaries in signal transduction. In the effector cell response, the effects of mechanical loading are dependent upon the magnitude, duration, and rate of the applied load. Longer duration, lower amplitude loading has the same effect on bone formation as loads with short duration and high amplitude. Loading must be cyclic to stimulate new bone formation. Aging greatly reduces the osteogenic effects of mechanical loading in vivo. Also, some hormones may interact with local mechanical signals to change the sensitivity of the sensor or effector cells to mechanical load.

Non-NASA Center↗

Fracture Behavior in Nylon 6 Fibers

Electron paramagnetic resonance (EPR) techniques are used to determine the number of free radicals produced during deformation leading to fracture of nylon 6 fibers. A reaction rate molecular model is proposed to explain some of the deformation and bond rupture behavior leading to fracture. High-strength polymer fibers are assumed to consist of a sandwich structure of disordered and ordered regions along the fiber axis. In the disordered or critical flaw regions, tie chains connecting the ordered or crystalline block regions are assumed to have a statistical distribution in length. These chains are, therefore, subjected to different stresses. The effective length distribution was determined by EPR. The probability of bond rupture was assumed to be controlled by reaction-rate theory with a stress-aided activation energy and behavior of various loadings determined by numerical techniques. The model is successfully correlated with experimental stress, strain, and bond rupture results for creep, constant rate loadings, cyclic stress, stress relaxation and step strain tests at room temperature.

Lloyd, B. A.↗

Controlled-strain rate tests at very low strain rates of 2618 aluminum at 200 C

Constant strain rate tests and constant load creep tests were performed on 2618 aluminum at 200 C. The strain rates used in the constant strain rate tests were 10 to the minus 6, 10 to the minus 7, 10 to the minum 8, and 10 to the minus 9/sec. Due to the fact that the strain rates in both tests were comparable to each other, the similarities between them can therefore be studied. It was concluded that metals are essentially rate sensitive at elevated temperatures. The traditional definition of creep and plasticity used in the classical creep analysis is actually a reflection of the material behavior under different loading conditions. A constitutive equation based on the test data under one loading condition should work well for other loading conditions as long as the strain rates are in the same range as those under which the material constants are determined.

Ding, J. L.↗

Lubrication of optimized-design tapered-roller bearings to 2.4 million DN

The performance of 120.65 mm (4.75 in.) bore high speed design, tapered roller bearings was investigated at shaft speeds to 20,000 rpm (2.4 million DN) under combined thrust and radial load. The test bearing design was computer optimized for high speed operation. Temperature distribution bearing heat generation were determined as a function of shaft speed, radial and thrust loads, lubricant flow rates, and lubricant inlet temperature. The high speed design, tapered roller bearing operated successfully at shaft speeds up to 20,000 rpm under heavy thrust and radial loads. Bearing temperatures and heat generation with the high speed design bearing were significantly less than those of a modified standard bearing tested previously. Cup cooling was effective in decreasing the high cup temperatures to levels equal to the cone temperature.

Parker, R. J.↗

Magnetohydrodynamics (MHD) Aerocapture System for Enabling Faster-Larger Planetary Science & Human Exploration Missions

Since our completing the NIAC Phase I NIAC on this Advanced Aerocapture System, NASA Langley Research Center has funded or supported a number of studies and code enhancements through its Center Innovation Fund (CIF) and NASA’s NSTGRO and Internship Programs to mature the analysis capabilities and quantify the merits of the MHD Aerocapture System technology. These efforts have resulted in a plug and play analysis capability for assessing MHD aerocapture system performance for arrival at many planetary bodies of interest. Our efforts have especially focused on the potential mass savings for improving the capacity for science observations at Neptune and Triton. A re-cent Forbes article published “‘Orbital mechanics is probably going to decide for us whether we go to Uranus or Neptune because we need to flyby Jupiter,’ said Kunio Sayanagi at Hampton University, Virginia, who also worked on the Neptune Odyssey proposal…. Exactly when a mission can be sent to Uranus, or Neptune, depends on the relative position of Jupiter, which can help give a spacecraft a gravitational slingshot. That drastically shortens the cruise phase.” [1] Since shortening the cruise phase is important for these science missions, any mass savings enabled by the MHD Aerocapture System could be reallocated to increasing Thermal Protection System mass to allow faster arrival speeds and/or for onboarding additional payloads such as science instruments, batteries, or propellant for conducting more science for longer durations in the desired orbits. The analysis steps and codes for conducting trades and sizing vehicles for aerocapture are as follows: Step 1 is to conduct aeroheating analysis using LAURA of the selected entry vehicle shape to identify locations on the forebody where ionization and flow velocity are sufficient for producing Lo-rentz forces. LAURA is a multiblock structured grid finite-volume CFD solver developed at the NASA Langley Research Center. [2] LAURA has been used for aerothermal analysis support of the entry, de-scent and landing (EDL) phase of interplanetary missions over the last three decades [3-7]. Step 2 is to port the LAURA results into CFDWARP to calcu-late electrical and thermal conductivities of ionized flow for sizing MHD patch system and calculating Lorentz forces needed for controls analysis. CFDWARP is a CFD code that uses advanced nu-merical methods that enable the simulation of the full coupling between the aerodynamics, the magne-tohydrodynamics, and the non-neutral plasma sheaths. CFDWARP has the unique capability to simulate efficiently the non-neutral sheaths (near the electrodes) in coupled form with the quasi-neutral bulk MHD flow [8-11]. Step 3 is to link re-sults from LAURA and CFDWARP into POST2 for calculating entry trajectories and comparing MHD control results with other aerodynamic control strategies. The Program to Optimize Simulated Tra-jectories II (POST2) is a generalized point mass, discrete parameter targeting and optimization pro-gram. POST2 provides the capability to target and optimize point mass trajectories for multiple pow-ered or un-powered vehicles near an arbitrary rotat-ing, oblate planet [12]. Step 4: TPS sizing was per-formed using the Fully Implicit Ablation and Ther-mal-response code (FIAT) tool which computes the transient one-dimensional thermal response and surface thermochemistry of a multilayer stackup of thermal protection, bonding, and structural materi-als subject to aeroheating on one surface [13]. The sizing and margining methodology used was based on the approach documented by Mahzari and Milos [14] for the dual-layered heatshield for extreme entry environment technology (DL-HEEET) TPS concept. TPS analysis utilizes trajectory information from POST2. Using this step-wise plug and play MHD Aerocapture performance assessment process, our analysis targets a Neptune aerocapture trajectory that will place the spacecraft in an observation orbit for Triton. [15]. Magnetohydrodynamic (MHD) control of a 4.5-meter diameter MSL-style capsule resulted in TPS mass savings of nearly 2000 kg when using an MHD system mass of under 200 kg. The flight path for a vehicle using the MHD control strategy has a much lower heat rate and heat load compared to the conventional aerodynamic aerocapture strategies known as bank angle con-trolled (BAC) and direct force controlled (DFC). Both BAC and DFC have heat rates significantly greater than 1500 W/cm2 typically used as an upper limit for PICA. Thus, DL-HEEET TPS concept was required for the BAC and DFC control strategies. However, considering the more benign environ-ments for the MHD case, additional TPS concepts with improved mass efficiency were also assessed. PICA was considered for the MHD controlled strat-egy since the maximum heat rate was well within the limits (<1500 W/cm2) of PICA. TPS sizing re-sulted in a significant mass reduction. The PICA layer for this sizing case was about 7.8 cm. As a point of reference, the Mars 2020 mission, which used this same PICA concept, had a PICA thickness of 3.18 cm [16]. The trajectories used for the TPS sizing originat-ed from the POST2 simulations. The current, I, to an electromagnet configuration can be manipulated to allow for active control of the vehicle. Manipula-tion of the current, I, changes the magnetic field, B, which affects the Lorentz force and therefore the MHD drag force on the vehicle. Our analysis in-cluded both open-loop and close-loop control. Closed-loop control will enable improved overall performance when taking into account mission level uncertainties, such as interplanetary delivery errors and atmospheric modeling uncertainties. The open-loop and closed-loop MHD control cases do not dip as deep into the atmosphere as the aerodynamic cases. Three types of aerodynamic-only approach-es are investigated: bank angle modulation (BAM), director force control (DFC), and Drag Modulated. BAM and DFC make use of vehicle aerodynamic angles to steer the vehicle. Thus, changing the aer-odynamic forces acting on the vehicle for control, aerodynamic drag modulated case requires a vary-ing drag area to modulate the drag force. The MHD drag modulated case modulates MHD generated drag force that adds to the aerodynamic drag. This higher atmospheric activation of drag forces by the MHD patch results in significantly less heat flux on the vehicle. The MHD technology will enable shorter cruise times and deceleration of larger payloads for increasing the capacity for science at the Ice Giants or for returning astronauts to Earth from cislunar space or from Mars. The purpose of this presentation is to provide more details about this work and to highlight plans for further research and development including a flight demonstration.

R. W. Moses↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗