Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOCATION CLOSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Airfoil Computational Fluid Dynamics - 9k shapes, 2 AoA's

This dataset contains aerodynamic quantities - including flow field values (momentum, energy, and vorticity) and summary values (coefficients of lift, drag, and momentum) - for 8,996 airfoil shapes, computed using the HAM2D CFD (computational fluid dynamics) model. The airfoil shapes were designed using the separable shape tensor parameterization that encodes two-dimensional shapes as elements of the Grassmann manifold. This data-driven approach learns two independent spaces of parameter from a collection of sample airfoils. The first captures large-scale, linear perturbations, and the second defines small-scale, higher-order perturbations. For this data, we used the G2Aero database of over 19,000 airfoil shapes to learn a parameter space that captured a wide array of shape characteristics. We fixed the linear deformations to be the mean over the database and sampled new shapes over a four-dimensional parameter space of higher-order perturbation. This sampling approaches allows for isolated analysis of non-linear airfoil shape deformations while holding other aspects (e.g., airfoil thickness) approximately constant. The aerodynamic quantities for the generated airfoil were obtained using the HAM2D code, which is a finite-volume Reynolds-averaged Navier-Stokes (RANS) flow solver. We employ a fifth-order WENO scheme for spatial reconstruction with Roe's flux difference scheme for inviscid flux and second-order central differencing for viscous flux. A preconditioned GMRES method is applied for implicit integration. The Spalart-Allmaras 1-eq turbulence model is used for the turbulence closure, and the Medida-Baeder 2-eq transition model is applied to account for the effects of laminar turbulent transition. The airfoil grid is generated with a total of 400 points on the airfoil surface, the initial wall-normal spacing of y+ = 1, and an outer boundary located at 300 chord lengths away from the wall. The CFD simulations are performed at a freestream Mach number of 0.1, Reynolds number of 9M, and at two angles of attack, 4 deg. and 12 deg. The simulations were performed using the Bridges-2 system at the Pittsburgh Supercomputing Center in February 2023 as part of the INTEGRATE project funded by the Advanced Research Projects Agency - Energy in the U.S. Department of Energy. The data was collected, reformatted, and preprocessed for this OEDI submission in July 2023 under the Foundational AI for Wind Energy project funded by the U.S. Department of Energy Wind Energy Technologies Office. This dataset is intended to serve as a benchmark against which new artificial intelligence (AI) or machine learning (ML) tools may be tested. Baseline AI/ML methods for analyzing this dataset have been implemented, and a link to their repository containing those models has been provided. The .h5 data file structure can be found in the GitHub Repository resource under explore_airfoil_9k_data.ipynb.

9k↗

Hanford and Savannah River Site Programmatic and Technical Integration

Abstract only. The Hanford Site and the Savannah River Site (SRS) were the primary plutonium production facilities within the U.S. nuclear weapons complex. Radioactive wastes were generated as part of these missions and are stored in similar fashion. The majority of radioactivity maintained by the two sites is located in underground carbon steel tanks in the physical form of supernatant, saltcake, or sludge. Disposition of SRS tank waste is ongoing by converting it into glass (pathway for sludge and radionuclides separated from supernatant or dissolved saltcake) or cement (pathway for the decontaminated supernatant and dissolved saltcake). Tank closure activity has also begun at SRS and will continue for the duration of mission. The Hanford tank waste inventory is roughly 2/3rds larger than SRS's by volume- but nominally half the radioactivity. The baseline disposition path includes high-level and low-activity waste vitrification with separate disposition of contact-handled transuranic tank waste. Retrieval of tank waste from aging single­ shell tanks (SSTs) into double-shell tanks (DSTs) is currently ongoing. As vitrification commences later this decade, Hanford will be in a similar operations mode as SRS. Site integration is increasing as the missions align. The ongoing integration is centered on key issues that impact both sites- regardless of mission timeframe. Three recent workshop exchanges have been held to improve communication with the primary intent of improving operations and technical work organization. The topics of these workshops are as follows: DST space utilization, optimization, and closure; Waste Feed Qualification; and, Cementitious Waste Forms. Key goals for these and future exchanges include aligning research and technology, preparing for joint initiatives (to maximize budgetary value for the customer), and reviewing lessons learned. Each site has played a leading role in the development of technology and operational practices that can be used to meet current challenges and to minimize the impact of future challenges. This paper provides an overview of the exchanges held, but predominately focuses on the team development and actions leading from the workshops.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Safety assessment for the radon-type surface disposal facility at Saakadze, Georgia - 15406

The Saakadze disposal facility is located about 40 km from Tbilisi and was planned and constructed during Soviet times as Radon-type surface facility to accommodate up to 600 m{sup 3} of low and intermediate level waste generated on the territory of Georgia. The disposal facility was operated from 1963 until its closure in 1995. The vast majority of waste in the Saakadze facility has been disposed of in two near surface concrete vaults with typical Radon-type dimensions, which cover layers already show significant structural damages. In order to assess the present safety of the site and provide the competent Georgian authorities with the necessary basis to take decisions in regard to the future of the repository, the European Commission launched and financially supported a project, which was assigned to a consortium of TUV-Nord ENSYS GmbH and DBE Technology GmbH. The safety assessment of Saakadze facility, which was an essential part of this project and which is the subject of this paper was carried out by DBE Technology GmbH. The Government of Georgia has been gradually increasing efforts to improve the regulatory processes and the legislation on nuclear and radiation safety, and, in particular, on safe management of radioactive waste and sealed radioactive sources. Currently, however, there are still areas where specific Georgian laws and regulations do not exist. Accordingly, in certain aspects IAEA recommendations and best practices were used as guidelines for the methodology of the safety assessment. In spite of the large uncertainties to be considered, especially in regard to the inventory, preliminary results of the safety assessment indicate that scenarios related to the groundwater pathway do not lead to radiological impacts that are above or near to limiting values. However, human intrusion scenarios might lead to dose rates for the critical group that are exceeding these values. This is mainly due to the fact that today there is no proper engineered cover on top of the concrete vaults. Based on the comparison of existing options and considering the results of the long-term safety assessment, it is recommended to backfill the remaining voids inside the concrete vaults and to construct an engineered cover to reduce the probability of human intrusion scenarios and to minimize their potential impact. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SECARB Regional Project Assessment

The SECARB Cranfield Early Test Project was designed to safely demonstrate large-scale, long-term CO 2 injection and storage in a CO 2 -enhanced oil recovery (EOR) operation and associated saline reservoir. Storage during EOR operations has the potential to offset commercial costs, holding a significant promise for future large-scale deployment in the southeastern United States. Denbury Onshore LLC began CO 2 -EOR operations in July 2008 at the Cranfield oilfield located east of Natchez, Mississippi (Figure 1). The location offered an ideal setting to investigate storage monitoring at a commercial CO 2 -EOR operation. The field team, led by the Gulf Coast Carbon Center of the Bureau of Economic Geology at the University of Texas at Austin, deployed the largest suite of monitoring, verification, accounting (MVA) technologies to collect data to assess long-term CO 2 utilization and storage. The CO 2 injection interval is within the 3,000-meter-deep fluvial lower Tuscaloosa Formation, a large and regionally extensive saline reservoir, at a broad four-way structural closure that defines the Cranfield oilfield. Tests were conducted in the oil-producing area as well as in the non-oil-producing brine aquifer. The CO 2 used during EOR operation was transported via pipeline from the Jackson Dome, a natural source of CO 2 . The study focused on four integrated research areas: (1) the High-Volume Injection Test area (HiVIT); (2) the Detailed Area of Study (DAS); (3) the Geomechanical area; and (4) the near-surface observatory, also called the “P-site.” CO 2 injection occurred at the HiVIT and the DAS (Figure 2 and Figure 3). The DAS was located down-dip of the oil-water interface of the Cranfield oilfield. The well layout included one injection well and two down-dip observation wells. The team was the first of the regional partnerships to monitor more than 1 million metric tons of CO 2 . At the end of the project, the team monitored more than 11 million metric tons of CO 2 injected and 5 million metric tons of CO 2 stored. The Cranfield Project was the fifth project worldwide, and the first such project in the United States, to reach this CO 2 injection volume while being monitored to demonstrate storage effectiveness.

01 COAL, LIGNITE, AND PEAT↗

Corrective Action Plan for Corrective Action Unit 568: Area 3 Plutonium Dispersion Sites Nevada National Security Site, Nevada, Revision 0 with ROTC 1

The purpose of this CAP is to provide the plan for implementation of the recommended corrective action alternatives (CAAs) for CAU 568. Site characterization activities were performed in 2014, and the results are presented in Appendix A of the CAU 568 CADD. The CAAs were recommended in the CADD. The scope of work required to implement the recommended CAAs of closure in place and clean closure at 11 of the 14 CASs includes the following: The installation of physical barriers over the nine safety experiment ground zeroes to cover contamination at CASs 03-23-20 (Otero), 03-23-23 (San Juan and Pascal-C), 03-23-31 (Pascal-B, Luna, Colfax), 03-23-32 (Pascal-A), 03-23-33 (Valencia), and 03-23-34 (Chipmunk); the characterization and removal of three soil and debris piles at CAS 03-08-04, and one HCA soil pile at CAS 03-23-30; the removal of three steel well head covers (PSM) from CASs 03-23-20 (Otero), 03-23-31 (Luna), and 03-23-33 (Valencia); the removal of soil and lead PSM from two locations at CAS 03-26-04; Implementation of FFACO use restrictions at nine safety experiment ground zeroes at CASs 03-23-20, 03-23-23, 03-23-31, 03-23-32, 03-23-33, and 03-23-34; the steel well head cover at CAS 03-23-23; the areas meeting HCA conditions at CASs 03-23-19 and 03-23-31; and the Boomer crater area at CAS 03-45-01. The FFACO use restriction boundaries will be presented in the CAU 568 closure report.

54 ENVIRONMENTAL SCIENCES↗

COMPENSATION OF FAST KICKER ROLLS WITH SKEW QUADRUPOLES

The development of the third generation light sources lead to the implementation of the top-up operation, when injection occurs while users collect data. The beam excursions due to the non-closure of the injection bump can spoil the data and need to be suppressed. In the horizontal plane compensation can be achieved by adjusting timing and kick amplitudes. The rolls of the kicker magnets create non-closure in the vertical plane and usually there is no means for correction. In the paper we describe proposed compensation scheme utilizing two skew quadrupoles placed inside the injection bump. The third generation light sources implement top-up operation firstly introduced at Advanced Photon Source. In this mode the circulating beam current is supported near constant by frequent injection of small charge, while photon beam is delivered for users. The beam perturbations caused by the mismatched injection bump can provide undesired noise in the user data. Usually the injection trigger is distributed to the users end stations so that those affected would be able to blank data acquisition. Nevertheless, as good operational practice such transients should be suppressed as much as possible. In the horizontal plane (which is commonly used for injection) one can adjust individual kicker strength as well as trigger delay while observing motion of the stored beam centroid. In the vertical plane such means are unavailable in the most cases. The possible solutions include dedicated weak vertical kickers and motorized adjustment of the roll angle of the injection kickers. Both abovementioned approaches are expensive and can significantly deteriorate reliability. We suggest two employ two skew quadrupoles (to correct both angle and position) placed inside the injection bump. In this case the beam position itself serves as measure of the kicker strength (assuming that kickers are well matched) and vertical kicks from the skew quadrupoles will be self synchronized with injection bump. In this paper we will consider the case when injection hardware (kickers and septa) are located in the same straight. Such an approach simplifies consideration but it can be generalized.

43 PARTICLE ACCELERATORS↗

The Amazon Water Cycle: Perspectives from Water Budget Closure and Ocean Salinity

Global and regional water cycle includes precipitation, water vapor divergence, and change of column water vapor in the atmosphere, and land surface evapotranspiration, terrestrial water storage change, and river discharge, which is linked to ocean salinity near the river mouth. The water cycle is a crucial component of the Earth system, and numerous studies have addressed its individual components (e.g., precipitation). Here we assess, for the first time, if remote sensing and reanalysis datasets can accurately and self-consistently portray the Amazon water cycle. This is further assisted with satellite ocean salinity measurements near the mouth of the Amazon River. The widely used practice of taking the mean of an ensemble of datasets to represent water cycle components (e.g., precipitation) can produce large biases in water cycle closure. Additionally, closure is achieved with only a small subset of data combinations (e.g., ERA5 precipitation and evapotranspiration plus GRACE satellite terrestrial water storage), which rules out the lower precipitation and higher evapotranspiration estimates, providing valuable constraints on assessments of precipitation, evapotranspiration, and their ratio. The common approach of using the Óbidos stream gauge (located hundreds of kilometers from the river mouth) multiplied by a constant (1.25) to represent the entire Amazon discharge is found to misrepresent the seasonal cycle, and this can affect the apparent influence of Amazon discharge on tropical Atlantic salinity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Syracuse University Industrial Assessment Center (Final Report)

Syracuse University Industrial Assessment Center (SU-IAC) project is focused on the two primary objectives: (i) educate undergraduate and graduate students in engineering and associated disciplines on the concepts of energy sustainability and to provide hands-on training by performing energy assessment at industrial facilities to become future energy efficiency experts, and (ii) offer energy assessments to small and mid-sized manufacturing companies in SU-IAC 2 the greater New York State region, perform analytical engineering work in support of assessment recommendations, and to report the results of those analyses to the client companies, to DOE, and to Field office personnel Through this project period, SU-IAC successfully trained 77 engineering students who were undergraduate or graduate students at Syracuse University College of Engineering, or at SU- IAC’s satellite center at Clarkson University. Each of these students received comprehensive ‘in-class’ technical training, safety training, and hands-on field training. The students performed various tasks related to energy assessment at the manufacturing facilities, including billing analysis, energy use reduction recommendations, and report preparation. Through this project period, a total of 34 students have completed all requirements of the SU-IAC program and have received the US DoE Certificate on Energy Efficiency, with the remaining students continuing at various stages of field work or training. During this project period, due to Covid-related measures in New York State, Syracuse University campus and most of the manufacturing facilities were completely closed or were under severe restrictions for access, for an extended period from March 2020 through April 2021. The closures affected our project execution, with the project Sponsor offering structured relief to carry-out a modified project during the affected budget periods. During this project period, SU-IAC student teams, led by its Director, completed a total of 77 energy assessments at small- and medium-scale manufacturing facilities located in New York State. For these facilities, SU-IAC prepared and presented details for 569 assessment recommendations (ARs). The facilities implemented a total of 258 of these ARs, realizing annual average energy savings in the range of $\$ $3,300 to $\$ $55,000 per facility. Cumulatively, these facilities have reduced their “first year after implementation” energy use by a total of 4.37 million kwh, and fuel use by a total of 27.7 billion BTU. SU-IAC project has successfully met the two primary objectives (and the associated sub objectives) and helped the manufacturing facilities in New York State achieve quantitative energy use reductions as a result of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Anticipated Electrical Environment Within Permanently Shadowed Lunar Craters

Shadowed locations ncar the lunar poles arc almost certainly electrically complex regions. At these locations near the terminator, the local solar wind flows nearly tangential to the surface and interacts with large-scale topographic features such as mountains and deep large craters, In this work, we study the solar wind orographic effects from topographic obstructions along a rough lunar surface, On the leeward side of large obstructions, plasma voids are formed in the solar wind because of the absorption of plasma on the upstream surface of these obstacles, Solar wind plasma expands into such voids) producing an ambipolar potential that diverts ion flow into the void region. A surface potential is established on these leeward surfaces in order to balance the currents from the expansion-limited electron and ion populations, Wc find that there arc regions ncar the leeward wall of the craters and leeward mountain faces where solar wind ions cannot access the surface, leaving an electron-rich plasma previously identified as an "electron cloud." In this case, some new current is required to complete the closure for current balance at the surface, and we propose herein that lofted negatively charged dust is one possible (nonunique) compensating current source. Given models for both ambipolar and surface plasma processes, we consider the electrical environment around the large topographic features of the south pole (including Shoemaker crater and the highly varied terrain near Nobile crater), as derived from Goldstone radar data, We also apply our model to moving and stationary objects of differing compositions located on the surface and consider the impact of the deflected ion flow on possible hydrogen resources within the craters

Farrell, W. M.↗

Development of an Integrated Leachate Treatment Solution for the Port Granby Waste Management Facility - 12429

The Port Granby Project (the Project) is located near the north shore of Lake Ontario in the Municipality of Clarington, Ontario, Canada. The Project consists of relocating approximately 450,000 m{sup 3} of historic Low-Level Radioactive Waste (LLRW) and contaminated soil from the existing Port Granby Waste Management Facility (WMF) to a proposed Long-Term Waste Management Facility (LTWMF) located adjacent to the WMF. The LTWMF will include an engineered waste containment facility, a Wastewater Treatment Plant (WTP), and other ancillary facilities. A series of bench- and pilot-scale test programs have been conducted to identify preferred treatment processes to be incorporated into the WTP to treat wastewater generated during the construction, closure and post-closure periods at the WMF/LTWMF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ANDRA's Underground Research Laboratory in Bure: Major Role in the Cigeo Development - 20005

The Industrial Center for Geological Disposal, also called Cigeo, is the deep geological disposal facility project developed by Andra since 1991. It is intended for the final disposal of High-Level Waste (HLW) and Intermediate Level Waste-Long Lived (ILW-LL) generated in France by the nuclear industry. Cigeo is located in the east of France (Meuse/Haute-Marne site). The disposal will be implemented in a 140 to 160 m thick clay layer at about 500 m depth. The license application file will be submitted in 2020. If the license is granted, the construction of the pilot phase of Cigeo (ramp, shafts, drifts, initial disposal vaults) could start in 2025 at the earliest. Since 2000, the development of the safety case of Cigeo for post closure has been supported by a three-stage construction, design, and scientific and technological experiment program performed in the French Underground Research Laboratory (URL) in Bure. These stages of the URL activities supported the iterative interactions between the knowledge acquired by scientific and technological R and D program, the design process and the safety assessment. The stages focused on assessing the suitability of the disposal concept, providing the basis for safety options and construction design, and preparing for licensing using large scale demonstrations. Recently, Andra launched the fourth development stage of the URL to implement a new set of technological experiments aiming at consolidating the design options of disposal cells and galleries for the pilot phase of Cigeo and at assessing monitoring technologies. Recently, Andra launched the fourth development stage of the URL to implement a new set of technological experiments aiming at consolidating the design of the pilot phase of Cigeo and at assessing design options and monitoring technologies. Removal of a segment ring, construction of an X drift crossing, improved construction techniques for HLW vaults, and construction of an ILW-LL prototype disposal vault are example activities during the fourth phase. In the future, the URL in Bure will remain a unique location to carry out research on promising technical solutions, to reduce Cigeo's construction and operation risks and strengthen the long-term safety assessment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Post-Closure Inspection, Sampling, and Maintenance Report for the Salmon, Mississippi, Site Calendar Year 2010

This report summarizes the annual inspection, sampling, measurement, and maintenance activities performed at the Salmon, Mississippi, Site in calendar year 2010. The draft Long-Term Surveillance and Maintenance Plan for the Salmon Site, Lamar County Mississippi (DOE 2007) specifies the submittal of an annual report of site activities with the results of sample analyses. The Salmon, MS, Site is a federally owned site located in Lamar County, MS, approximately 12 miles west of Purvis, MS, and about 21 miles southwest of Hattiesburg, MS (Figure 1). The U.S. Department of Energy (DOE), a successor agency to the U.S. Atomic Energy Commission (AEC), is responsible for the long-term surveillance and maintenance of the 1,470-acre site. DOE's Office of Legacy Management (LM) is the operating agent for the surface and subsurface real estate.

54 ENVIRONMENTAL SCIENCES↗

Special Analysis for the Disposal of the Consolidated Edison Uranium Solidification Project Waste Stream at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nye County, Nevada

The purpose of this Special Analysis (SA) is to determine if the Oak Ridge (OR) Consolidated Edison Uranium Solidification Project (CEUSP) uranium-233( 233 U) waste stream (DRTK000000050, Revision 0) is acceptable for shallow land burial (SLB) at the Area 5 Radioactive Waste Management Site (RWMS) on the Nevada National Security Site (NNSS). The CEUSP 233 U waste stream requires a special analysis because the concentrations of thorium- 229 ( 229 Th), 230 Th, 232 U, 233 U, and 234 U exceeded their NNSS Waste Acceptance Criteria action levels. The acceptability of the waste stream is evaluated by determining if performance assessment (PA) modeling provides a reasonable expectation that SLB disposal is protective of human health and the environment. The CEUSP 233 U waste stream is a long-lived waste with unique radiological hazards. The SA evaluates the long-term acceptability of the CEUSP 233 U waste stream for near-surface disposal as a two tier process. The first tier, which is the usual SA process, uses the approved probabilistic PA model to determine if there is a reasonable expectation that disposal of the CEUSP 233 U waste stream can meet the performance objectives of U.S. Department of Energy Manual DOE M 435.1-1, “Radioactive Waste Management,” for a period of 1,000 years (y) after closure. The second tier addresses the acceptability of the OR CEUSP 233 U waste stream for near-surface disposal by evaluating long-term site stability and security, by performing extended (i.e., 10,000 and 60,000 y) modeling analyses, and by evaluating the effect of containers and the depth of burial on performance. Tier I results indicate that there is a reasonable expectation of compliance with all performance objectives if the OR CEUSP 233 U waste stream is disposed in the Area 5 RWMS SLB disposal units. The maximum mean and 95 th percentile PA results are all less than the performance objective for 1,000 y. Monte Carlo uncertainty analysis indicates that there is a high likelihood of compliance with all performance objectives. Tier II results indicate that the long-term performance of the OR CEUSP 233 U waste stream is protective of human health and the environment. The Area 5 RWMS is located in one of the least populated and most arid regions of the U.S. Site characterization data indicate that infiltration of precipitation below the plant root zone at 2.5 meters (8.2 feet) ceased 10,000 to 15,000 y ago. The site is not expected to have a groundwater pathway as long as the current arid climate persists. The national security mission of the NNSS and the location of the Area 5 RWMS within the Frenchman Flat Corrective Action Unit require that access controls and land use restrictions be maintained indefinitely. PA modeling results for 10,000 to 60,000 y also indicate that the OR CEUSP 233 U waste stream is acceptable for near-surface disposal. The mean resident air pathway annual total effective dose (TED), the resident all-pathways annual TED, and the acute drilling TED are less than their performance objectives for 10,000 y after closure. The mean radon-222 (222Rn) flux density exceeds the performance objective at 4,200 y, but this is due to waste already disposed at the Area 5 RWMS and is only slightly affected by disposal of the CEUSP 233 U. The peak resident all-pathways annual TED from CEUSP key radionuclides occurs at 48,000 y and is less than the 0.25 millisievert performance objective. Disposal of the OR CEUSP 233 U waste stream in a typical SLB trench slightly increases PA results. Increasing the depth was found to eliminate any impacts of the OR CEUSP 233 U waste stream. Containers could not be shown to have any significant impact on performance due to the long half-life of the waste stream and a lack of data for pitting corrosion rates of stainless steel in soil. The results of the SA indicate that all performance objectives can be met with disposal of the OR CEUSP 233 U waste stream in the SLB units at the Area 5 RWMS. The long-term performance of the OR CEUSP 233 U waste stream disposed in the near surface is protective of human health and the environment. The waste stream is recommended for disposal without conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A re-evaluation of finite-element models and stress-intensity factors for surface cracks emanating from stress concentrations

A re-evaluation of the 3-D finite-element models and methods used to analyze surface crack at stress concentrations is presented. Previous finite-element models used by Raju and Newman for surface and corner cracks at holes were shown to have ill-shaped elements at the intersection of the hole and crack boundaries. These ill-shaped elements tended to make the model too stiff and, hence, gave lower stress-intensity factors near the hole-crack intersection than models without these elements. Improved models, without these ill-shaped elements, were developed for a surface crack at a circular hole and at a semi-circular edge notch. Stress-intensity factors were calculated by both the nodal-force and virtual-crack-closure methods. Both methods and different models gave essentially the same results. Comparisons made between the previously developed stress-intensity factor equations and the results from the improved models agreed well except for configurations with large notch-radii-to-plate-thickness ratios. Stress-intensity factors for a semi-elliptical surface crack located at the center of a semi-circular edge notch in a plate subjected to remote tensile loadings were calculated using the improved models. The ratio of crack depth to crack length ranged form 0.4 to 2; the ratio of crack depth to plate thickness ranged from 0.2 to 0.8; and the ratio of notch radius to the plate thickness ranged from 1 to 3. The models had about 15,000 degrees-of-freedom. Stress-intensity factors were calculated by using the nodal-force method.

Tan, P. W.↗

Analysis of Composite Panel-Stiffener Debonding Using a Shell/3D Modeling Technique

Interlaminar fracture mechanics has proven useful for characterizing the onset of delaminations in composites and has been used successfully primarily to investigate onset in fracture toughness specimens and laboratory size coupon type specimens. Future acceptance of the methodology by industry and certification authorities, however, requires the successful demonstration of the methodology on the structural level. For this purpose, a panel was selected that is reinforced with stiffeners. Shear loading causes the panel to buckle, and the resulting out-of-plane deformations initiate skin/stiffener separation at the location of an embedded defect. A small section of the stiffener foot, web and noodle as well as the panel skin in the vicinity of the delamination front were modeled with a local 3D solid model. Across the width of the stiffener foot, the mixedmode strain energy release rates were calculated using the virtual crack closure technique. A failure index was calculated by correlating the results with a mixed-mode failure criterion of the graphite/epoxy material. Computed failure indices were compared to corresponding results where the entire web was modeled with shell elements and only a small section of the stiffener foot and panel were modeled locally with solid elements. Including the stiffener web in the local 3D solid model increased the computed failure index. Further including the noodle and transition radius in the local 3D solid model changed the local distribution across the width. The magnitude of the failure index decreased with increasing transition radius and noodle area. For the transition radii modeled, the material properties used for the noodle area had a negligible effect on the results. The results of this study are intended to be used as a guide for conducting finite element and fracture mechanics analyses of delamination and debonding in complex structures such as integrally stiffened panels.

Krueger, Ronald↗

Development of three-dimensional models for WIPP performance assessment using PFLOTRAN - 15073

The Waste Isolation Pilot Plant (WIPP), located in southeastern New Mexico, has been developed by the U.S. Department of Energy (DOE) for the deep geologic disposal of transuranic (TRU) waste. WIPP performance assessment (PA) calculations estimate the probability and consequence of potential radionuclide releases from the repository to the accessible environment for a regulatory period of 10,000 years after facility closure. To date, WIPP PA calculations have employed multiple 2D numerical models requiring simplification of the mesh and processes. Introducing 3D numerical models within WIPP PA enables increasingly realistic representations of the WIPP subsurface domain and improved flexibility for incorporating relevant features. Furthermore, the increased computing capacity afforded by modern hardware architectures enables this 3D modeling. Modeling in 3D will be more flexible because less homogenization is required and better accuracy of the results can be obtained by making fewer assumptions and/or simplifications. The use of PFLOTRAN, a state-of-art massively parallel subsurface flow and reactive transport code, will enable this 3D modeling, and eliminate the need for multiple related, but decoupled 2D models. However, there are capabilities that PFLOTRAN must be demonstrated in order to fulfill requirements for WIPP PA. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Post-Closure Inspection, Sampling, and Maintenance Report for the Salmon, Mississippi, Site Calendar Year 2011

This report summarizes the 2011 annual inspection, sampling, measurement, and maintenance activities performed at the Salmon, Mississippi, Site (Salmon site1). The draft Long-Term Surveillance and Maintenance Plan for the Salmon Site, Lamar County, Mississippi (DOE 2007) specifies the submittal of an annual report of site activities with the results of sample analyses. The Salmon site consists of 1,470 acres. The site is located in Lamar County, Mississippi, approximately 10 miles west of Purvis, Mississippi, and about 21 miles southwest of Hattiesburg, Mississippi.

54 ENVIRONMENTAL SCIENCES↗

Co-optimized machine-learned manifold models for large eddy simulation of turbulent combustion

Many modeling approaches in large eddy simulation (LES) of turbulent combustion employ a projection of the thermochemical state onto a low-dimensional manifold within state space to reduce the number of transported variables and hence computational cost. Flamelet-generated manifolds (FGM) is an example of a well-established, physics-based approach, but increasingly, principal component analysis (PCA) is being used as a data-driven method for generating manifold models. For both approaches, the nonlinear relationship between the location on the predefined manifold and the outputs of interest, such as reaction rates, can be tabulated or encoded in a neural network. This work proposes a new approach for manifold modeling that extends these existing approaches. A modified neural network structure simultaneously encodes the definition of the manifold variables, the nonlinear mapping, and the subfilter closure for LES. This allows all three of these aspects of the model to be co-optimized, generating a model from any source of combustion thermochemical state data. The manifold parameterizing variables are constrained to be linear combinations of species, as in FGM and PCA-based models, to aid in interpretability and implementation. For LES, subfilter variances of the manifold variables are also included as inputs. Two types of a priori analysis are performed to evaluate the new approach. In the first, the model is trained on data from one-dimensional premixed flames. In this case, the approach recovers the behavior of flamelet-based manifold approaches, and in fact slightly improves performance by identifying an optimized progress variable. The approach is also applied to data from direct numerical simulations of spherical ignition kernels in isotropic turbulence. For any specified manifold dimensionality, the new approach provides substantially lower prediction errors than a PCA-based model developed from the same data set. Additionally, the LES formulation of the new approach can provide accurate predictions for filtered reaction rates across a variety of filter widths.

97 MATHEMATICS AND COMPUTING↗