Search NASA⌕ Search

SEARCH · Search NASA

Results for “Leg”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Hybrid thermocouple development program

The design and development of a hybrid thermocouple, having a segmented SiGe-PbTe n-leg encapsulated within a hollow cylindrical p-SiGe leg, is described. Hybrid couple efficiency is calculated to be 10% to 15% better than that of a all-SiGe couple. A preliminary design of a planar RTG, employing hybrid couples and a water heat pipe radiator, is described as an example of a possible system application. Hybrid couples, fabricated initially, were characterized by higher than predicted resistance and, in some cases, bond separations. Couples made later in the program, using improved fabrication techniques, exhibited normal resistances, both as-fabricated and after 700 hours of testing. Two flat-plate sections of the reference design thermoelectric converter were fabricated and delivered to NASA Lewis for testing and evaluation.

Garvey, L. P.↗

Splanchnic vasoconstriction in hyperthermic man - Role of falling blood pressure.

Results of a study in which six supine resting subjects, wearing water-perfused suits, had body skin temperature controlled at 35 C for 30 min (control period), then rapidly increased to 40.5 C for 43 to 50 min (heating period) in a two-part experiment. In the first part of the experiment arterial mean pressure (MP) in three men was increased back to, or above control levels at the 30 to 35th min of heating by total occlusion of both legs for 8 to 10 min. Splanchnic blood flow (SBF), which had fallen from 1.4 to 0.9 L/min at occlusion, rose only 0.05 L/min during occlusion. Splanchnic vascular resistance (SVR) rose throughout heating and occlusion. In the second part of the experiment (three men) SBF fell despite a spontaneous rise in MP and aortic pulse pressure prior to leg occlusion. Cardiac output (CO) was measured just before, during and after occlusion. Occlusion raised MP 10 to 15 mm Hg and reduced CO only slightly. It is concluded that falling MP or aortic pulse pressure are not major causes of the splanchnic vasoconstriction in response to heating man.

Rowell, L. B.↗

Vehicle for use in planetary exploration

A self-propelled vehicle particularly suited for use in traversing hostile terrain is described. The vehicle is characterized by a plurality of mutually independently operable propulsion units, each including an extended leg coupled with the frame of the vehicle. The vehicle is propelled through a selectively operable power train functioning to drive the leg in rotation about its axis and/or activating the pedestal in a wheel-driven and/or track-laying mode of operation.

Hryniewiecki, E.↗

Spacecraft reorientation via slewing about nonorthogonal axes

A mathematical procedure was developed which determines the exact slews relative to any known axes. The axes may be completely arbitrary; their coordinates merely reside on a data base which can be changed at any time without affecting the software. Given the desired reorientation, the procedure then determines all of the two-legged or three-legged slews which will accomplish the reorientation. For example, there are 12 possible permutations of three axes, and if they are orthogonal each always has two solutions. The nonorthogonal case, on the other hand, gives some surprising results, including the nonexistence of a solution: Consider a large reorientation where the three axes are nearly collinear. In this connection, it can be shown that every three-axis reorientation can be accomplished by three successive slews, if and only if the middle axis is perpendicular to the other two.

Davenport, P. B.↗

The Hat Creek millimeter-wave interferometer.

A fixed-baseline millimeter-wave interferometer, operating initially at 13.5 mm, has been put into operation at the Hat Creek Observatory as the first step in the development of a two-element aperture synthesis telescope. The first system consists of a 3-m antenna and a 6-m antenna spaced 265 m apart. Large receiver bandwidths may be used at high frequencies, and this system employs an intermediate frequency bandwidth of about 400 MHz. The instrument has been used to derive accurate absolute positions of interstellar water vapor sources, to study Mercury, Venus, and Mars, and to make crude maps of a few complex continuum sources. The synthesis telescope, the next stage, has two 6-m antennas which can be located at various stations on a T-shaped track. The east-west leg is 300 m and the north-south leg is 200 m, permitting full synthesis for sources on the equator and at declinations as low as -30 deg as well as at high declinations.

Hills, R. E.↗

Final analysis and design of a thermal protection system for 8-foot HTST combustor

The cylindrical shell combustor with T-bar supports in the 8-foot HTST at the NASA-Langley Research Center encountered vibratory fatigue cracking over a period of 50-250 tunnel tests within a limited range of the required operating envelope. A preliminary design study provided several suitable thermal protection system designs for the combustor, one of which was a two-pass regenerative type air-cooled omega-shaped segment liner. A final design layout of the omega segment liner was prepared and analyzed for steady-state and transient conditions. The design of a support system for the fuel spray bar assembly was also included. Detail drawings suitable for fabrication purposes were also prepared. Liner design problems defined during the preliminary study included (1) the ingress of gas into the attachment bulb section of the omega segment, (2) the large thermal gradient along the leg of the omega bulb attachment section and, (3) the local peak metal temperature at the radius between the liner ID and the leg of the bulb attachment. These were resolved during the final design task. Analyses of the final design of the omega segment liner indicated that all design goals were met and the design provided the capability of operating over the required test envelope with a life expectancy substantially above the goal of 1500 cycles.

Moskowitz, S.↗

Round trip Mars missions using looping trajectories in the 1980-2000 time period

Round trip Mars missions combining a standard trajectory leg and a looping trajectory leg are suggested as an alternative to the more conventional trajectories. Looping trajectories are shown to make it possible to trade a slight increase in total mission time for a significant reduction in Mars stay time, with the possible added benefit of a decrease in energy requirements.

Kibler, J. F.↗

Observations at Mercury encounter by the plasma science experiment on Mariner 10

A fully developed bow shock and magnetosheath were observed near Mercury, providing unambiguous evidence for a strong interaction between Mercury and the solar wind. Inside the sheath there is a distinct region analogous to the magnetosphere or magnetotail of earth, populated by electrons with lower density and higher temperature than the electrons observed in the solar wind or magnetosheath. At the time of encounter, conditions were such that a perpendicular shock was observed on the inbound leg and a parallel shock was observed on the outbound leg of the trajectory, and energetic plasma electron events were detected upstream from the outbound shock crossing. The interaction is most likely not atmospheric, but the data clearly indicate that the obstacle to solar wind flow is magnetic, either intrinsic or induced.

Ogilvie, K. W.↗

Study of bone mineral metabolism

The use of Sr-85 as an indicator of the skeletal location and relative amount of bone demineralization which occurs during immobilization of the body or body parts, bed-rest or space flight was studied. The bone mineral replacement which occurs after immobilization was measured rather than the bone loss which occurs during immobilization. In a study with two adult beagle dogs, the Sr-85 uptake in a leg which had been immobilized for two months was 400 percent higher than the uptake in the legs in regular use. This increased uptake probably resulted from only a few percent loss in bone mineral and indicates that losses less than one percent can be easily detected and located. The sensitivity, simplicity, and low radiation dose associated with the use of this method indicates that it should receive consideration for use on humans in bed-rest and space flight studies. Methods for measuring changes in total body nitrogen and in assisting the Johnson Space Center in calibrating a whole body counter for total body potassium measurements were also investigated.

Palmer, H. E.↗

Outer planet mission guidance and navigation for spinning spacecraft

The orbit determination accuracies, maneuver results, and navigation system specification for spinning Pioneer planetary probe missions are analyzed to aid in determining the feasibility of deploying probes into the atmospheres of the outer planets. Radio-only navigation suffices for a direct Saturn mission and the Jupiter flyby of a Jupiter/Uranus mission. Saturn ephemeris errors (1000 km) plus rigid entry constraints at Uranus result in very high velocity requirements (140 m/sec) on the final legs of the Saturn/Uranus and Jupiter/Uranus missions if only Earth-based tracking is employed. The capabilities of a conceptual V-slit sensor are assessed to supplement radio tracking by star/satellite observations. By processing the optical measurements with a batch filter, entry conditions at Uranus can be controlled to acceptable mission-defined levels (+ or - 3 deg) and the Saturn-Uranus leg velocity requirements can be reduced by a factor of 6 (from 139 to 23 m/sec) if nominal specified accuracies of the sensor can be realized.

Paul, C. K.↗

Apollo flight crew cardiovascular evaluations

The results of the lower body negative pressure (LBNP) and passive stand tests are presented, and the efficacy of the experimental antihypotensive garments is evaluated. Results of the tests are presented in tabular form. Postflight orthostatic evaluations during the Apollo program indicate that reduction in orthostatic tolerance is a consequence of space flight exposure. Heart rate, the most reliable index, was increased, while systolic and pulse pressures were decreased during immediate postflight evaluations using lower body negative pressure and passive standing as the orthostatic stress. Elevation in resting heart rate was a less frequent finding. There was considerable variability in the magnitude of these changes between individual crewmembers and in the persistence of the changes over subsequent postflight evaluations. Postflight changes in leg volume during LBNP were equal to or less than those seen during preflight baseline evaluations. Body weight, resting calf girth, supine leg volume, and cardiothoracic ratios were all diminished immediately postflight, and return to preflight values was not complete within the postflight testing time frame.

G.W. Hoffler↗

Device for installing rocket engines

A device for installing rocket engines is reported that is supported at a cant relative to vertical by an axially extensible, tiltable pedestal. A lifting platform supports the rocket engine at its thrust chamber exit, including a mount having a concentric base characterized by a concave bearing surface, a plurality of uniformly spaced legs extended radially from the base, and an annular receiver coaxially aligned with the base and affixed to the distal ends of said legs for receiving the thrust chamber exit. The lifting platform rests on a seat concentrically related to the pedestal and affixed to an extended end portion thereof having a convex bearing surface mated in sliding engagement with the concave bearing surface of the annular base for accommodating a rocking motion of the platform.

George, T. R., Jr.↗

Catheter tip force transducer for cardiovascular research

A force transducer for measuring dynamic force activity within the heart of a subject essentially consists of a U-shaped beam of low elastic compliance material. Two lines extend from the beams's legs and a long coil spring is attached to the beam. A strain gauge is coupled to one of the beam's legs to sense deflections thereof. The beam with the tines and most of the spring are surrounded by a flexible tube, defining a catheter, which is insertable into a subject's heart through an appropriate artery. The tines are extractable from the catheter for implantation into the myocardium by pushing on the end of the spring which extends beyond the external end of the catheter.

Feldstein, C.↗

Measurement of auroral Birkeland currents

Results are presented for measurements of the auroral current made with a rocket-borne experiment over Fort Churchill, Canada, during the February-May period in 1968. On the upward leg of the rocket flight there were detected a westward auroral current of 10,000 A near 96 km altitude and two oppositely directed Birkeland currents of about 0.00005 A per sq m at about 160 km altitude. On the downward leg there were revealed a westward filament of current of about 0.0008 A per sq m at about 220 km altitude, two oppositely directed Birkeland sheet currents of about 0.00014 A per sq m at about 230 km altitude, and two oppositely directed Birkeland currents of about 0.00007 A per sq m which fed a westward auroral electrojet of about 0.0010 A per sq m at about 100 km altitude and were associated with a bright rayed arc. A reversal in the Birkeland current system near midnight was also observed. These observations are probably manifestations of the complex nature of small-scale currents associated with complicated auroral forms.

Ifedili, S. O.↗

Regional measurement of body nitrogen

Studies of methods for determining changes in the muscle mass of arms and legs are described. N-13 measurements were made in phantom and cadaver parts after neutron irradiation. The reproducibility in these measurements was found to be excellent and the radiation dose required to provide sufficient activation was determined. Potassium-40 measurements were made on persons who lost muscle mass due to leg injuries. It appears that K-40 measurements may provide the most accurate and convenient method for determining muscle mass changes.

Palmer, H. E.↗

Automatic blood pressure measuring system (M091)

The Leg Volume Measuring System is used to measure leg calf girth changes that occur during exposure to lower body negative pressure as a result of pooling of blood and other fluids in the lower extremities.

Source record↗

Investigate methods for measuring muscle and bone mass changes in astronauts and animals which occur during space flight

Sodium-22 is being used as a tracer for bone mineral metabolism studies. Dogs are being grown from puppies to adulthood on a diet containing a constant level of sodium-22 in order to uniformly tag the entire skeleton with a long lived radionuclide. This study is still in progress and the dogs are still growing. Potassium-40 measurements were made on people, who are replacing muscle mass lost due to leg injuries, in a second study. It appears that potassium-40 measurements provide an accurate and convenient method for determining relative changes in the muscle content of the leg.

Palmer, H. E.↗

Influence of central venous pressure upon sinus node responses to arterial baroreflex stimulation in man

Measurements were made of sinus node responses to arterial baroreceptor stimulation with phenylephrine injection or neck suction, before and during changes of central venous pressure provoked by lower body negative pressure or leg and lower truck elevation. Variations of central venous pressure between 1.1 and 9.0 mm Hg did not influence arterial baroreflex mediated bradycardia. Baroreflex sinus node responses were augmented by intravenous propranolol, but the level of responses after propranolol was comparable during the control state, lower body negative pressure, and leg and trunk elevation. Sinus node responses to very brief baroreceptor stimuli applied during the transitions of central venous pressure also were comparable in the three states. The authors conclude that physiological variations of central venous pressure do not influence sinus node responses to arterial baroreceptor stimulation in man.

Mark, A. L.↗