Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Tracking Accuracy of a Real-Time Fiducial Tracking System for Patient Positioning and Monitoring in Radiation Therapy

Purpose: In radiation therapy there is a need to accurately know the location of the target in real time. A novel radioactive tracking technology has been developed to answer this need. The technology consists of a radioactive implanted fiducial marker designed to minimize migration and a linac mounted tracking device. This study measured the static and dynamic accuracy of the new tracking technology in a clinical radiation therapy environment. Methods and Materials: The tracking device was installed on the linac gantry. The radioactive marker was located in a tissue equivalent phantom. Marker location was measured simultaneously by the radioactive tracking system and by a Microscribe G2 coordinate measuring machine (certified spatial accuracy of 0.38 mm). Localization consistency throughout a volume and absolute accuracy in the Fixed coordinate system were measured at multiple gantry angles over volumes of at least 10 cm in diameter centered at isocenter. Dynamic accuracy was measured with the marker located inside a breathing phantom. Results: The mean consistency for the static source was 0.58 mm throughout the tested region at all measured gantry angles. The mean absolute position error in the Fixed coordinate system for all gantry angles was 0.97 mm. The mean real-time tracking error for the dynamic source within the breathing phantom was less than 1 mm. Conclusions: This novel radioactive tracking technology has the potential to be useful in accurate target localization and real-time monitoring for radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-efficiency acceleration in the laser wakefield by a linearly increasing plasma density

The acceleration length and the peak energy of the electron beam are limited by the dephasing effect in the laser wakefield acceleration with uniform plasma density. Based on 2D-3V particle in cell simulations, the effects of a linearly increasing plasma density on the electron acceleration are investigated broadly. Comparing with the uniform plasma density, because of the prolongation of the acceleration length and the gradually increasing accelerating field due to the increasing plasma density, the electron beam energy is twice higher in moderate nonlinear wakefield regime. Because of the lower plasma density, the linearly increasing plasma density can also avoid the dark current caused by additional injection. At the optimal acceleration length, the electron energy can be increased from 350 MeV (uniform) to 760 MeV (linearly increasing) with the energy spread of 1.8%, the beam duration is 5 fs and the beam waist is 1.25 μm. This linearly increasing plasma density distribution can be achieved by a capillary with special gas-filled structure, and is much more suitable for experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

From 3rd- to 4th-generation light sources: Free-electron lasers in the X-ray range

Activities on free-electron laser (FEL) x-ray sources, based on linear accelerators, to produce spatially coherent, ultra-short ({approx}100 fs) pulses with very high peak brilliance (10{sup 28}-10{sup 32} photons/s/mm{sup 2}/mrad{sup 2}/0.1% BW) are summarized. The scientific case includes time-resolved studies of dynamics on sub-ps scales, structural studies by imaging of non-periodic systems, and investigation of high energy-density phenomena such as non-linear x-ray optics and the production of warm dense matter. Examples are presented, with emphasis on the operational facilities, FLASH at DESY, Hamburg and LCLS in Stanford, California, and on the European XFEL project in Hamburg.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Extended State Observer-Based Robust Model Predictive Velocity Control for Permanent Magnet Synchronous Motor

This article proposes an extended state observer based robust model predictive velocity control to decrease system prediction error under parameter uncertainties for permanent magnet synchronous motor (PMSM). We develop a new PMSM model that consists of velocity and acceleration to lump the system information and an external disturbance into a disturbance. The extended state observer (ESO) is designed to estimate the velocity, acceleration, and disturbance. By estimating the state variables and disturbance using the ESO, the model predictive control (MPC) finds the optimal control input by predicting future system behavior. Additionally, the direct current controller is designed so that the direct current converges to zero. Because the proposed method is not designed based on the cascade structure from the viewpoint of velocity control, the optimization control for the velocity and currents can be defined. Thus, the proposed method is robust against external disturbances and parameter uncertainties owing to feedback linearization, state feedback, and ESO-based MPC using the acceleration PMSM model. The proposed control algorithm was experimentally verified and it showed improved velocity tracking performance compared with ESO-based MPC using the conventional PMSM model.

42 ENGINEERING↗

Fast Approximate Methods for Modified Gravity Cosmological Simulations

The accelerated expansion of the Universe poses a major theoretical puzzle. Although the assumption of a non-zero cosmological constant provides a minimal extension of general relativity that is consistent with observational data, many theories of modified gravity have been suggested as possible alternatives. Predictions of structure formation for these models in the fully nonlinear regime are very expensive and it is difficult, if not impossible, to explore such a huge space of models and parameters using high-resolution N-body simulations. Even in the mildly nonlinear regime, perturbative methods can become extremely complex. We explore whether simplified dynamical approximations, applicable for a certain set of cosmological probes, can be used to investigate models of modified gravity with acceptable accuracy in the latter instance. For the case of chameleon gravity, we find that these methods can indeed be used to explore the region around the baryon acoustic oscillation scale, k ~ 0:1 hMpc-1 but not much further.

cosmology↗

Clustering effects for explaining an anomalous JLab result on the {sup 9}Be structure function

An anomalous nuclear modification was reported by JLab measurements on the beryllium-9 structure function F{sub 2}. It is unexpected in the sense that a nuclear modification slope is too large to be expected from its average nuclear density. We investigated whether it is explained by a nuclear clustering configuration in {sup 9}Be with two {alpha} nuclei and surrounding neutron clouds. Such clustering aspects are studied by using antisymmetrized molecular dynamics (AMD) and also by a simple shell model for comparison. We consider that nuclear structure functions F{sub 2}{sup A} consist of a mean conventional part and a remaining one depending on the maximum local density. The first mean part does not show a significant cluster effect on F{sub 2}. However, we propose that the remaining one could explain the anomalous JLab slope, and it is associated with high densities created by the cluster formation in {sup 9}Be. The JLab measurement is possibly the first signature of clustering effects in high-energy nuclear reactions. A responsible physics could be an internal nucleon modification, which is caused by the high densities due to the cluster configuration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beam-driven acceleration in ultra-dense plasma media

Accelerating parameters of beam-driven wakefield acceleration in an extremely dense plasma column has been analyzed with the dynamic framed particle-in-cell plasma simulator, and compared with analytic calculations. In the model, a witness beam undergoes a TeV/m scale alternating potential gradient excited by a micro-bunched drive beam in a 10{sup 25 }m{sup −3} and 1.6 × 10{sup 28 }m{sup −3} plasma column. The acceleration gradient, energy gain, and transformer ratio have been extensively studied in quasi-linear, linear-, and blowout-regimes. The simulation analysis indicated that in the beam-driven acceleration system a hollow plasma channel offers ∼20% higher acceleration gradient by enlarging the channel radius (r) from 0.2 λ{sub p} to 0.6 λ{sub p} in a blowout regime. This paper suggests a feasibility of TeV/m scale acceleration with a hollow crystalline structure (e.g., nanotubes) of high electron plasma density.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design Criteria for High-Gradient Radio-Frequency Linacs

This article will review methods used at the SLAC National Accelerator Laboratory and other world accelerator laboratories to design high-gradient normal conducting accelerating structures. A quest for compact radio-frequency linacs fueled decades of studies toward a higher accelerating gradient. A major phenomena limiting the increase of the gradient is vacuum radio-frequency breakdown; therefore, this paper will address the breakdown physics and discuss approaches that reduce the breakdown probability. This discussion will cover both the electrical design and fabrication technology of the accelerating structures to achieve practical operating accelerating gradients in excess of 100 MV/m. Most of the data described here were obtained during the development of 11 GHz linacs for electron–positron linear colliders, so extrapolation of the results to other frequencies should be performed cautiously.

Dolgashev, Valery A. (ORCID:0000000166715402)↗

Transonic aeroelastic computations on wings using Navier-Stokes equations

Aeroelastic computations are made on fighter type wings in the transonic regime. The flow is modeled using the Navier-Stokes equations and is coupled with structural equations of motion. The flow equations are solved by a time accurate finite difference scheme with moving grids. The coupled aeroelastic equations of motion are solved using the linear acceleration method. The configuration adaptive dynamic grids are time-accurately generated using the aeroelastically deformed shape of the wing. Computations are made for oscillating rigid wings with moving shock waves in the presence of leading edge vortices. The computed results compare well with the experiment. Unsteady computations are made to demonstrate the shock-vortex interaction phenomenon on wings in ramp motion. Effects of flexibility and pitch rate are demonstrated for flows with vortices.

Guruswamy, Guru P.↗

Jerk Minimization Method for Vibration Control in Buildings

In many vibration minimization control problems for high rise buildings subject to strong earthquake loads, the emphasis has been on a combination of minimizing the displacement, the velocity and the acceleration of the motion of the building. In most cases, the accelerations that are involved are not necessarily large but the change in them (jerk) are abrupt. These changes in magnitude or direction are responsible for most building damage and also create discomfort like motion sickness for inhabitants of these structures because of the element of surprise. We propose a method of minimizing also the jerk which is the sudden change in acceleration or the derivative of the acceleration using classical linear quadratic optimal controls. This was done through the introduction of a quadratic performance index involving the cost due to the jerk; a special change of variable; and using the jerk as a control variable. The values of the optimal control are obtained using the Riccati equation.

Abatan, Ayo O.↗

Development of an ion beam analyzing system for the KBSI heavy-ion accelerator

The Korea Basic Science Institute (KBSI) has been developing a heavy ion accelerator system to accelerate high current, multi-charge state ions produced by a 28 GHz superconducting electron cyclotron ion source. A beam analyzing system as a part of the low energy beam transport apparatus was developed to select charged particles with desirable charge states from the ion beams. The desired species of ion, which is generated and extracted from the ECR ion source including various ion particles, can be selected by 90° dipole electromagnet. Due to the non-symmetrical structure in the coil as well as the non-linear permeability of the yoke material coil, a three dimensional analysis was carried out to confirm the design parameters. In this paper, we present the experimental results obtained as result of an analysis of KBSI accelerator. The effectiveness of beam selection was confirmed during the test of the analyzing system by injecting an ion beam from an ECR ion source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic production of hyperon resonances

The study of hyperon resonances has entered a new era of precision with advent of high-statistics photoproduction data from the CLAS detector at Jefferson Lab. These data have multi-particle final states, allowing clean identification of exclusive reactions associated with strange mesons and baryons. Examples of physics results are: evidence for isospin interference in the decay of the {Lambda}(1405) resonance; a strong suggestion of meson cloud effects in the structure of the {Sigma}(1385) resonance; data from K* photoproduction that will test the existence of the purported K{sub 0}(800) meson. Properties of other hyperon resonances will also be studied in the near future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An online x-ray based position validation system for prostate hypofractionated radiotherapy

Purpose: Accurate positioning of the target volume during treatment is paramount for stereotactic body radiation therapy (SBRT). In this work, the authors present the development of an in-house software tool to verify target position with an Elekta-Synergy linear accelerator using kV planar images acquired during treatment delivery. Methods: In-house software, SeedTracker, was developed in MATLAB to perform the following three functions: 1. predict intended seed positions in a planar view perpendicular to any gantry angle, simulating a portal imaging device, from the 3D seed co-ordinates derived from the treatment planning system; 2. autosegment seed positions in kV planar images; and 3. report the position shift based on the seed positions in the projection images. The performance of SeedTracker was verified using a CIRS humanoid phantom (CIRS, VA, USA) implanted with three Civco gold seed markers (Civco, IA, USA) in the prostate. The true positive rate of autosegmentation (TPR{sub seg}) and the accuracy of the software in alerting the user when the isocenter position was outside the tolerance (TPR{sub trig}) were studied. Two-dimensional and 3D static position offsets introduced to the humanoid phantom and 3D dynamic offsets introduced to a gel phantom containing gold seeds were used for evaluation of the system. Results: SeedTracker showed a TPR{sub seg} of 100% in the humanoid phantom for projection images acquired at all angles except in the ranges of 80°–100° and 260°–280° where seeds are obscured by anatomy. This resulted in a TPR{sub trig} of 88% over the entire treatment range for considered 3D static offsets introduced to the phantom. For 2D static offsets where the position offsets were only introduced in the anterior–posterior and lateral directions, the TPR{sub trig} of SeedTracker was limited by both seed detectability and positional offset. SeedTracker showed a false positive trigger in the projection angle range between 130°–170° and 310°–350° (a maximum of 24% of treatment time) due to limited information that can be derived from monoscopic images. The system accurately determined the dynamic trajectory of the isocenter position in the superior and inferior direction for the studied dynamic offset scenarios based on the seed position in monoscopic images. Conclusions: The developed software has been shown to accurately autosegment the seed positions in kV planar images except for two 20° arcs where seeds are obscured by anatomical structures. The isocenter trajectories determined by the system, based on the monoscopic images, provide useful information for monitoring the prostate position. The developed system has potential application for monitoring prostate position during treatment delivery in linear accelerator based SBRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design and demonstration of an economical SRF structure for Continuous Wave (CW), high-energy, Megawatt-class beams

Due to its very high RF-to-beam efficiency, superconducting radiofrequency (SRF) cavities have become the technology of choice for the construction of large linear accelerators (linacs) for basic science applications (examples, ESS and PIP-II). The technology is also attractive for high volume industrial applications such as electron irradiation processing of wastewater and flue gas. However, SRF’s current reliance on liquid helium for cryogenic cooling introduces infrastructural and safety challenges for use in industrial settings. Cryocooler conduction-cooling is a recently developed novel technique for operating SRF cavities without requiring liquid helium. This project aims for technical design and economic assessment of a medium energy, high average power e-beam linac based on the conduction-cooled SRF technique for high volume irradiation treatment of wastewater. The goals of this project are (1) to design a medium energy (10 MeV), high average power (1 MW) electron beam accelerator around the cryocooler conduction-cooled SRF cavity technology, (2) demonstrate the required accelerating voltage on a prototype cavity, and (3) build a cost-model to evaluate capital and operating expense of the accelerator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nucleon spin structure at low momentum transfers

The generalized Gerasimov-Drell-Hearn sum rule is known to be very sensitive to QCD radiative and power corrections. We improve the previously developed QCD-inspired model for the Q{sup 2} dependence of the Gerasimov-Drell-Hearn sum rule. We take into account higher order radiative and higher-twist power corrections extracted from precise Jefferson Lab data on the lowest moment of the spin-dependent proton structure function {Gamma}{sub 1}{sup p}(Q{sup 2}) and on the Bjorken sum rule {Gamma}{sub 1}{sup p-n}(Q{sup 2}). By using the singularity-free analytic perturbation theory we demonstrate that the matching point between chiral-like positive-Q{sup 2} expansion and QCD operator product 1/Q{sup 2} expansion for the nucleon spin sum rules can be shifted down to rather low Q{approx_equal}{Lambda}{sub QCD} leading to a good description of recent proton, neutron, deuteron, and Bjorken sum rule data at all accessible Q{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-240: EPID-Based Quality Assurance for Dosimetric Credentialing

Purpose: We propose a novel dosimetric audit method for clinical trials using EPID measurements at each center and a standardized EPID to dose conversion algorithm. The aim of this work is to investigate the applicability of the EPID method to different linear accelerator, EPID and treatment planning system (TPS) combinations. Methods: Combination of delivery and planning systems were three Varian linacs including one Pinnacle and two Eclipse TPS and, two ELEKTA linacs including one Pinnacle and one Monaco TPS. All Varian linacs had the same EPID structure and similarly for the ELEKTA linacs. Initially, dose response of the EPIDs was investigated by acquiring integrated pixel value (IPV) of the central area of 10 cm2 images versus MUs, 5-400 MU. Then, the EPID to dose conversion was investigated for different system combinations. Square field size images, 2, 3, 4, 6, 10, 15, 20, 25 cm2 acquired by all systems were converted to dose at isocenter of a virtual flat phantom then the dose was compared to the corresponding TPS dose. Results: All EPIDs showed a relatively linear behavior versus MU except at low MUs which showed irregularities probably due to initial inaccuracies of irradiation. Furthermore, for all the EPID models, the model predicted TPS dose with a mean dose difference percentage of 1.3. However the model showed a few inaccuracies for ELEKTA EPID images at field sizes larger than 20 cm2. Conclusion: The EPIDs demonstrated similar behavior versus MU and the model was relatively accurate for all the systems. Therefore, the model could be employed as a global dosimetric method to audit clinical trials. Funding has been provided from Department of Radiation Oncology, TROG Cancer Research and the University of Newcastle. Narges Miri is a recipient of a University of Newcastle postgraduate scholarship.

43 PARTICLE ACCELERATORS↗

Measurement of Drell-Yan Process with Polarized Proton Beams at J-PARC

We have proposed the construction of a spectrometer at J-PARC designed for the detection of high-mass dimuons produced in the interactions of 50 GeV primary proton beams. We have also proposed the acceleration of polarized proton beams at the J-PARC facility. Through the detections of the Drell-Yan events, a broad physics program addressing various issues in QCD is pursued. In the Drell-Yan transverse single-spin asymmetry measurement, we can explore the Sivers effect which is closely related to the orbital angular motion of partons inside the proton. Many other rich programs of spin-dependent structure function physics are carried out through the measurements of unpolarized, singly polarized, and doubly polarized Drell-Yan processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-throughput injection-acceleration of electron bunches from a linear accelerator to a laser wakefield accelerator

Plasma-based accelerators (PBAs) driven by either intense lasers (laser wakefield accelerators, LWFAs) or particle beams (plasma wakefield accelerators, PWFAs), can accelerate charged particles at extremely high gradients compared to conventional radio-frequency (RF) accelerators. In the past two decades, great strides have been made in this field, making PBA a candidate for next-generation light sources and colliders. However, these challenging applications necessarily require beams with good stability, high quality, controllable polarization and excellent reproducibility. To date, such beams are generated only by conventional RF accelerators. As such, it is important to demonstrate the injection and acceleration of beams first produced using a conventional RF accelerator, by a PBA. In some recent studies on LWFA staging and external injection-acceleration in PWFA only a very small fraction (from below 0.1% to few percent) of the injected charge (the coupling efficiency) was accelerated. For future colliders where beam energy will need to be boosted using multiple stages, the coupling efficiency per stage must approach 100%. Here we report the first demonstration of external injection from a photocathode-RF-gun-based conventional linear accelerator (LINAC) into a LWFA and subsequent acceleration without any significant loss of charge or degradation of quality, which is achieved by properly shaping and matching the beam into the plasma structure. Furthermore, this is an important step towards realizing a high-throughput, multi-stage, high-energy, hybrid conventional-plasma accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗