Search NASA⌕ Search

SEARCH · Search NASA

Results for “Loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

In situ study of microstructure evolution and α → ω phase transition in annealed and pre-deformed Zr under hydrostatic loading

The detailed study of the effect of the initial microstructure on its evolution under hydrostatic compression before, during, and after the irreversible α → ω phase transformation and during pressure release in Zr using in situ x-ray diffraction is presented. Two samples were studied: one is plastically pre-deformed Zr with saturated hardness and the other is annealed. Phase transformation α → ω initiates at lower pressure for a pre-deformed sample but for a volume fraction of ω Zr, c > 0.7, a larger volume fraction is observed for the annealed sample. This implies that the proportionality between the athermal resistance to the transformation and the yield strength in the continuum phase transformation theory is invalid; an advanced version of the theory is outlined. Phenomenological plasticity theory under hydrostatic loading is outlined in terms of microstructural parameters, and plastic strain is estimated. During transformation, the first rule is suggested, i.e., the average domain size, microstrain, and dislocation density in ω Zr for c < 0.8 are functions of the volume fraction, c of ω Zr only, which are independent of the plastic strain tensor prior to transformation and pressure. The microstructure is not inherited during phase transformation. Surprisingly, for the annealed sample, the final dislocation density and the average microstrain after pressure release in the ω phase are larger than for the severely pre-deformed sample. The results suggest that an extended experimental basis is required for the predictive models for the combined pressure-induced phase transformations and microstructure evolutions.

36 MATERIALS SCIENCE↗

A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches

Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.

Dark Matter detectors (WIMPs, axions, etc.)↗

Using Co-Simulation to Model Interconnect-Scale Power Systems from Loads to Generators

Co-simulation is a modeling technique that allows analysts to combine simulation tools and their corresponding models to exchange data during run-time, allowing the creation of larger and more complex models across heterogeneous domains. HELICS is a co-simulation platform developed over the past six years that has been shown to be effective for these multi-domain analysis. Recently, a HELICS-based analysis was completed where the ERCOT electrical interconnect in the United States was modeled in high detail from bulk power system generation to individual customer loads. This model was used to evaluate a flat-rate and transactive energy tariff with integrated wholesale and retail real-time and day-ahead energy markets. This modeling allows detailed analysis showing how the operations of the power system under these tariffs impact all actors in the power system, from individual customers to bulk power system operators.

co-simulation, HELICS, transactive energy system, ↗

A Transactive Approach for Service Restoration Utilizing Customer Load Flexibility and Grid-Edge Resources

This paper develops a transactive energy system model to restore electricity to customers in an isolated distribution system after an outage. The model is developed to engage a variety of customer types - prosumers, flexible loads, critical/noncritical customers, and distributed generators - as active participants in the restoration process. Unlike many existing transactive approaches, the proposed model is developed for service restoration and accounts for various customer types and their autonomy and privacy through an iterative approach to determine the optimal market price, while maintaining systemlevel power flow and voltage constraints. The advantages of the proposed approach are numerically validated on a modified IEEE 123-bus test system.

distributed energy resources↗

Fault-Tolerant Deep Learning Cache with Hash Ring for Load Balancing in HPC Systems

Large-scale DL on HPC systems like Frontier and Summit uses distributed node-local caching to address scalability and performance challenges. However, as these systems grow more complex, the risk of node failures increases, and current caching approaches lack fault tolerance, jeopardizing large-scale training jobs. We analyzed six months of SLURM job logs from Frontier and found that over 30% of jobs failed after an average of 75 minutes. To address this, we propose fault-tolerance strategies that recache data lost from failed nodes using a hash ring technique for balanced data recaching in the distributed node-local caching, reducing reliance on the PFS. Our extensive evaluations on Frontier showed that the hash ring-based recaching approach reduced training time by approximately 25% compared to the approach that redirects I/O to the PFS after node failures and demonstrated effective load balancing of training data across nodes.

Lee, Seoyeong↗

An Optimization-Based HVAC Load and PV Disaggregation Methodology With Contextual Supervision

Here, this letter presents an optimization-based Heating, Ventilation, and Air Conditioning (HVAC) and PV disaggregation approach. This letter builds on the previous works of authors, which discuss HVAC disaggregation strategy for aggregated levels without requiring sub-metered information. This letter expands on previous works to discuss optimization-based HVAC disaggregation by varying PV penetration scenarios with joint disaggregation of HVAC load and PV.

Analytics↗

Unified Modeling Architecture for Load Management in Extreme Heat: The New York City Case

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on this key subject by assessing the feasibility of using coastal-urban renewable energy resources, namely, offshore wind and rooftop photovoltaic systems, to meet electricity demand of New York City during the intense recent heat wave period of June 2025. A unified modeling framework, based on the urbanized weather research and forecasting model, is used to simulate climate, renewable resources, and energy demand variables. Findings show significant energy load mismatch of approximately 1150 GWh over the month, between the demand and the combined renewable generation outcome. Three storage integration scenarios are analyzed to mitigate the deficits, reducing said deficits by a minimum of approximately 9% over the duration of the month. This study provides a transferable modeling framework tool for evaluating renewable integration in dense urban environments that can be used by grid operators to support grid resilience during extreme heat events.

54 ENVIRONMENTAL SCIENCES↗

Computational study on the impact of gasoline-ethanol blending on autoignition and soot/NO x emissions under low-load gasoline compression ignition conditions

Here, in the present work, computational fluid dynamics (CFD) simulations of a single-cylinder gasoline compression ignition (GCI) engine are performed to investigate the impact of gasoline-ethanol blending on autoignition, nitrogen oxide (NO x ), and soot emissions under low-load conditions. In order to represent the test gasoline (RD5-87), a four-component toluene primary reference fuel (TPRF)+ethanol (ETPRF) surrogate (with 10% ethanol by volume; E10) is employed. A three-dimensional (3D) engine CFD model employing finite-rate chemistry with a skeletal kinetic mechanism (including NO x sub-mechanism), adaptive mesh refinement (AMR), and hybrid method of moments (HMOM) is adopted to capture the in-cylinder combustion phenomena and soot/NO x emissions. The engine CFD model is validated against experimental data for three gasoline-ethanol blends: E10, E30 and E100, with varying ethanol content by volume. Model validation is carried out for a broad range of start-of-injection (SOI) timings (−21, −27, −36, and −45 crank angle degrees (°CA) after top-dead-center (aTDC)) with respect to in-cylinder pressure, heat release rate, combustion phasing, NO x and soot emissions. For relatively later injection timings (−21 and −27 °CA aTDC), E30 yields higher amount of soot than E10; while the trend reverses for early injection cases (−36 and −45 °CA aTDC ). On the other hand, E100 yields the lowest amount of soot among all fuels irrespective of SOI timing. Further, E10 shows a non-monotonic trend in soot emissions with SOI timing: SOI-36>SOI-45>SOI-21>SOI-27, while soot emissions from E30 exhibit monotonic decrease with advancing SOI timing. NO x emissions from various fuels follow a trend of E10>E30>E100. On the other hand, NO x emissions increase as SOI timing is advanced for all fuels, with an anomaly for E10 and E100 where NO x decreases when SOI is advanced beyond −36 °CA aTDC. Detailed analysis of the numerical results is performed to investigate the soot/NO x emission trends and elucidate the impact of chemical composition and physical properties on autoignition and emissions characteristics.

Computational fluid dynamics↗

Mechanical response of HFIR-irradiated M5FRAMATOME cladding under simple and complex loading conditions

This study investigates the mechanical behavior of High Flux Isotope Reactor (HFIR) irradiated M5FRAMATOME cladding under simple and complex loading conditions through axial tensile and reversible cyclic bending. Axial tension specimens were pre-machined prior to HFIR irradiation while cyclic bend specimens were inserted as intact tubes. Tests articles were neutron-irradiated to 4 and 16 dpa, and specimens were tested at ORNL's hotcell facilities. The axial tension tests were conducted under constant displacement control, and the reversible cyclic bend tests were performed using ORNL's Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) apparatus. Results showed that mechanical response of Cr-coated and uncoated M5FRAMATOME cladding were similar and independent of irradiation dose for axial tension tests, while Cr-coated specimens’ reversible cyclic bend behavior differed from uncoated counterparts. For all tests, irradiation temperature showed a significant impact on the mechanical behavior. Below 280°C, all axial tensile specimens whether coated or not behaved similarly. Above 280°C, YS and UTS showed decrease with increasing irradiation temperature. A similar behavior was also observed in cyclic bend tests as well. The mechanical damage during cyclic bend tests was linked to damage accumulation in unirradiated Cr-coated zircaloy-4 specimens, and the effect of irradiation temperature was related to changing characteristics of defect mobility during high temperature irradiation.

Cinbiz, Nedim [ORNL] (ORCID:0000000346268515)↗

Characterizing electrical demand and load diversity of low-power water and space heating appliances in US homes

Home renovation and remodeling projects can involve costly and time consuming electrical infrastructure upgrades at the household level. From the grid perspective they also lead to costly replacement of local infrastructure, such as transformers, and can add stress to the grid at peak times. The emergence of innovative, power-efficient household appliances offers a way to minimize these problems. These appliances are designed for lower power consumption, simplifying installation through standard plug-in connections, reducing the need for new electric circuits/panels/service, and minimizing the peak power demand for the home. Key examples include low-power heat pump water heaters (HPWHs) and cold climate window heat pumps that operate on standard 120V outlets. To assess the real-world impact of these solutions, we compiled and analyzed power metering data from several US field studies. This data provides insights into the effects on peak power demand of selecting lower-power appliances. Our analysis focuses on several key metrics, including the maximum power demand of individual appliances, their operational runtime, continuous operation and load diversity. While individual low-power 120V space and water heating appliances offer significant peak demand reductions compared to 240V heat pump or resistance alternatives, their longer runtimes might increase the likelihood of operation during whole-dwelling peak events, albeit at lower power levels.

Less, Brennan↗

Upcycling Linear Low-Density Polyethylene Waste into Graphene for High Mass Loading Supercapacitors

Polyethylene is notoriously difficult to upcycle because it decomposes into light gases at approximately 350-400 °C which prevents processing it at higher temperatures to convert it into electrode materials. We address this challenge by using an air-based, thermos-oxidative process, which heats linear low-density polyethylene (LLDPE) just below the decomposition point to initiate oxidation and cross-linking of LLDPE alkyl chains. These molecular transformations allow LLDPE to be graphenized at 950 °C without decomposing. The LLDPE-derived graphene (LLDPE-G) has a BET specific surface area up to 1,800 m2/g and Raman ID/IG ratio of 0.85. When used as electrode material for a symmetric supercapacitor with the 1 M H2SO4 electrolyte, LLDPE-G possesses an specific capacitance up to 175 F/g at mass loading of 20 mg/cm2, yielding an areal capacitance of 3.5 F/cm2. The cycling stability with capacitance demonstrates a retention of 95.8% after 100,000 cycles at high current density of 4.0 A/g.

Gao, Yuan↗

Upcycling Low Linear Density Polyethylene Waste into Turbostratic Graphene for High Mass Loading Supercapacitors

In this work, LLDPE was upcycled into a high quality turbostratic graphene using a pre-treatment step to oxidatively crosslink the polymer with the assistance of solid additives (KCl and K2CO3) that improve crosslinking by increasing the effective surface area of the polymer melt during processing. After this pretreatment step, the crosslinked polymer could then be carbonized and catalytically graphenized between 400-950 °C without complete decomposition of the material. The LLDPE derived graphene (LLDPE-G) obtained from this process has a Brunauer–Emmett–Teller (BET) specific surface area, up to 1800 m2g-1 and average Raman ID/IG and I2D/IG ratios of 0.85 and 0.57, respectively, indicating high quality graphene. When used as an electrode material in symmetric supercapacitors, LLDPE-G possesses an outstanding specific capacitance up to 175 Fg-1 at a mass loading of 20 mgcm-2, which is two times the commercial requirement, yielding an excellent areal capacitance of 3.5 Fcm-2. Moreover, LLDPE-G exhibits exceptional cycling stability with a capacitance retention of 95.8% after 100,000 cycles at a current density of 4.0 Ag-1. Additionally, the KCl and K2CO3 were recycled and reused over 3 complete cycles to make new LLDPE-G with the material quality and electrocapacitive performance retained and verified after each cycle. Our approach creates new opportunities for upcycling not only waste LLDPE but also other varieties of PE to high value graphene materials.

Gao, Yuan [NETL Site Support Contractor, National ↗

Design Load Basis Guidance for Distributed Wind Turbines

Aeroelastic modeling (AM) is the primary methodology for structural and performance assessment of any wind turbine. Nonetheless, the use of AM in the distributed wind (DW) industry sector is limited due to several challenges (Damiani, Davis, & Summerville, 2022). One of these challenges lies in the perceived complexity of generating a proper set of numerical simulations to extract and process the key outputs for component design and verification, and, ultimately, achieve certification. This makes it difficult to reliably predict the structural and performance response of small wind turbines. From the investigation carried out in (Damiani & Davis, 2022), it is apparent that many stakeholders in this sector believe that a comprehensive guide for developing a design load basis (DLB) for distributed wind turbines (DWTs) is necessary.

17 WIND ENERGY↗

Quartz Ampoule Loading, Sealing, and Inspection

This procedure applies to the loading of materials into quartz ampoules and flame sealing these ampoules. Flame sealed quartz ampoules are commonly used as a sealed containment for neutron irradiation. Due to the importance of maintaining containment for this application, this procedure involves a double encapsulation design wherein a sealed inner ampoule is sealed is in turn sealed within a larger diameter outer ampoule. General guidance for inspection of ampoules by destructive, non-destructive, qualitative (e.g., visual) and other methods are given. Materials to be placed inside the ampoules may consist of stable element materials or radioactive materials in either solid or liquid form. Liquids shall be dried prior to sealing the ampoule.

36 MATERIALS SCIENCE↗

Integration of thermally anisotropic building envelopes with TES and advanced controls to tailor HVAC loads

Heating, ventilation, and air conditioning (HVAC) systems are the primary energy consumers in buildings to meet heating or cooling energy demands. The building envelope can play an active role in reducing this demand and associated costs by collecting thermal energy naturally available, such as diurnal temperature swings, solar irradiance, and night sky radiation cooling, to offset heating and cooling loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Power, Load-Balancing Whole Home Electrification Solution: Cooperative Research and Development (Final Report)

Testing was conducted at the Systems Performance Laboratory in NREL’s Energy Systems Integration Facility to test the performance of 120V wall-mounted heat pumps, 120V heat pump water heaters (HPWH), Electric Vehicle Supply Equipment (EVSE), and other plug-in loads, using NeoCharge Smart Splitters and whole home energy software as appropriate. Four different simulated occupancy scenarios were used to evaluate the package of technology and controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

T&D LIBRA: Simulation Framework for Transmission and Distribution Load and IBR Assessment

This paper introduces T&D LIBRA, a HELICS-based dynamic co-simulation framework designed for transmission and distribution (T&D) load and inverter-based resource assessment. This framework is designed to model interactions between single-phase induction motors (i.e., Motor-D), distributed energy resources (DERs) and the transmission network, emphasizing system stability during fault conditions. The primary objective of this research is to study the fault-induced delayed voltage recovery (FIDVR) behavior of the T&D networks using the co-simulation framework and to compare the results with conventional PSS/E only simulations. Simulations are validated using T&D co-simulations with a single distribution node and the IEEE 123-bus distribution test case. The co-simulation results demonstrate the value of using T&D co-simulations to capture motor stalling, DER tripping and other sources of voltage diversity on distribution networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗