Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Gravity Estimation from a Simulated GRACE Mission: Short vs. Long Arcs

We present simulations of gravity estimation from a GRACE-like satellite mission: low-low intersatellite tracking with a precision of order 1 micron s(exp -1) yielding gravity fields of degree and order 120. We employ a unique parameterization of the intersatellite baseline vector which allows the gravity estimation to be performed (relatively) independently of the GPS (global positioning system) tracking data once sufficiently accurate orbits are obtained. This considerably simplifies data processing during the gravity estimation. During that process only certain components of the baseline parameterization need be adjusted; other components are uncorrelated with gravity and may be adopted unchanged from the initial GPS orbits. The technique is also amenable to very short arcs of data. We present comparisons of gravity estimation from 30 days of observations with arcs of length 15 minutes vs. arcs of one day. Our 'truth' field is the EGM96 (Earth Gravitational Model) model; our prior field is a degree-70 clone of EGM96, perturbed from it by amounts comparable to the standard errors of EGM96 (and identically zero for degrees 71-120). For a high inclination orbit, the short-arc analysis recovers low order gravity coefficients remarkably well, although higher order terms, especially sectorial terms, are understandably less accurate. The simulations suggest that either long or short arcs of GRACE data are likely to improve parts of the geopotential spectrum by several orders of magnitude. This is especially so for low order coefficients, which are markedly improved for all degrees through 120.

Rowlands, David D.↗

Photometric Observations of 6000 Stars in the Cygnus Field

A small photometer to detect transits by extrasolar planets has been assembled and is being tested at Lick Observatory on Mt. Hamilton, California. The Vulcan photometer is constructed from a 30 cm focal length, F/2.5 AeroEktar reconnaissance lens and Photometrics PXL16800 CCD camera. A spectral filter is used to confine the pass band from 480 to 763 mn. It simultaneously monitors 6000 stars brighter than 12th magnitude within a single star field in the galactic plane. When the data are folded and phased to discover low amplitude transits, the relative precision of one-hour samples is about 1 part per thousand (10 x l0(exp -3)) for many of the brighter stars. This precision is sufficient to find jovian-size planets orbiting solar-like stars, which have signal amplitudes from 5 to 30 x l0(exp -3) depending on the inflation of the planet and the size of the star. Based on the frequency of giant inner-planets discovered by Doppler-velocity method, one or two planets should be detectable in a rich star field. The goal of the observations is to obtain the sizes of giant extrasolar planets in short-period orbits and to combine these with masses determined from Doppler velocity measurements to determine the densities of these planets. A further goal is to compare the measured planetary diameters with those predicted from theoretical models. From August 10 through September 30 of 1998, a forty nine square degree field in the Cygnus constellation centered at RA and DEC of 19 hr 47 min, +36 deg 55 min was observed. Useful data were obtained on twenty-nine nights. Nearly fifty stars showed some evidence of transits with periods between 0.3 and 8 days. Most had amplitudes too large to be associated with planetary transits. However, several stars showed low amplitude transits. The data for several transits of each of these two stars have been folded and been folded into 30 minute periods. Only Cygl433 shows any evidence of a flattened bottom that is expected when a small object transits a much larger primary. However when high-resolution spectra were obtained for both stars, the stars were found to be double-lined binaries so similar in size as to have indistinguishable transit depths. The low amplitude of the transits is explained if the stellar orbital planes are tipped approximately 5 degrees from the line of sight causing both binaries to show grazing transits. The two absorption lines, due to the H(sub beta) feature in each star, are apparent and indicate the presence of a binary system with similar components.

Borucki, W.↗

A GNSS Receiver for Small-Sats Enabling Precision POD, Radio Occultations and Reflections

A low cost, low power, and low mass GNSS receiver (called Cion) has been developed and is currently flying on the CICERO cubesats. The receiver was designed in less than a year by JPL for Tyvak and GeoOptics for use in the GeoOptics CICERO constellation and leverages 25 years of JPL GNSS reciever design experience. Cion uses a commercial off-the-shelf (COTS) computer along with existing space qualified RF down-converters, software, and firmware to produce atmospheric Radio Occultation (RO) data. By combining a FPGA with dual core ARM processor and an embedded system controller, the Xilinx Zynq processor is an enabling technology that provides a customizable digital signal processing platform integrated into the computer (System on a chip) and enables off-the-shelf hardware to become the main engine behind this software defined radio. Using Linux for the on-board computer allows for fast development times and liberal use of existing open source software libraries. The parts of the receiver that require realtime implementation are performed in the Field Programmable Gate Array (FPGA), which can also be reprogrammed in flight. While the Zynq is not rad hard, the silicon on insulator (SOI) technology is rad tolerant ‘by accident’, allowing for its use in many space-based applications. Early results show that the Cion is working as designed, has demonstrated the first known GLONASS occultations, and obtains high quality atmospheric profiles with excellent lower troposphere penetration (near Earth’s surface).

Young, Larry↗

Reactions of atomic thorium and uranium cations with CF 4 studied by guided ion beam tandem mass spectrometry

The fundamental chemistry of the actinides continues to be an area of interest because of their use in nuclear fuel cycles. Here, the kinetic energy dependences of the reactions of thorium and uranium cations with CF 4 were studied using guided ion beam tandem mass spectrometry. The products observed include AnF x + (An = Th or U, x = 1-3) and CF y + (y = 1-3). Although most reactions are exothermic according to literature thermochemistry, all cross sections display strong endothermic features indicating a restriction in the reactivity at low energies. For both actinides, only the AnF + + CF 3 product channel is observed at low energies; however, its formation proceeds very inefficiently. Furthermore, these results indicate that the reactions of Th + and U + with CF 4 are not thermodynamically driven and suggest that the low-energy reactivity results from precise alignment of the reactants.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of methods for the NMR measurement of motionally averaged dipolar couplings

Motionally averaged dipolar couplings are an important tool for understanding the complex dynamics of catalysts, polymers, and biomolecules. While there is a plethora of solid-state NMR pulse sequences available for their measurement, in can be difficult to gauge the methods’ strengths and weaknesses. In particular, there has not been a comprehensive comparison of their performance in natural abundance samples, where 1H homonuclear dipolar couplings are important and the use of large MAS rotors may be required for sensitivity reasons. In this work, we directly compared some of the more common methods for measuring C–H dipolar couplings in natural abundance samples using L-alanine (L-Ala) and the N-formyl-L-methionyl-L-leucyl-L-phenylalanine (fMLF) tripeptide as model systems. Here, we evaluated their performance in terms of accuracy, resolution, sensitivity, and ease of implementation. We found that, despite the presence of 1H homonuclear dipolar interactions, all methods, with the exception of REDOR, were able to yield the reasonable dipolar coupling strengths for both mobile and static moieties. Of these methods, PDLF provides the most convenient workflow and precision at the expense of low sensitivity. In low-sensitivity cases, MAS-PISEMA and DIPSHIFT appear to be the better options.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined analysis of HPK 3.1 LGADs using a proton beam, beta source, and probe station towards establishing high volume quality control

The upgrades of the CMS and ATLAS experiments for the high luminosity phase of the Large Hadron Collider will employ precision timing detectors based on Low Gain Avalanche Detectors (LGADs). We present a suite of results combining measurements from the Fermilab Test Beam Facility, a beta source telescope, and a probe station, allowing full characterization of the HPK type 3.1 production of LGAD prototypes developed for these detectors. We demonstrate that the LGAD response to high energy test beam particles is accurately reproduced with a beta source. Finally, we further establish that probe station measurements of the gain implant accurately predict the particle response and operating parameters of each sensor, and conclude that the uniformity of the gain implant in this production is sufficient to produce full-sized sensors for the ATLAS and CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion-Assisted Nanoscale Material Engineering in Atomic Layers

Achieving deterministic control over the properties of low-dimensional materials with nanoscale precision is a long-sought goal. Mastering this capability has a transformative effect on the design of multifunctional electrical and optical devices. Here, we present an ion-assisted synthetic technique that enables precise control over the material composition and energy landscape of two-dimensional (2D) atomic crystals. Our method transforms binary transition-metal dichalcogenides, like MoSe2, into ternary MoS2αSe2(1-α) alloys with systematically adjustable compositions, α. By piecewise assembly of the lateral, compositionally modulated MoS2αSe2(1-α) segments within 2D atomic layers, we present a synthetic pathway toward the realization of multicompositional designer materials. Our technique enables the fabrication of advanced 2D structures with arbitrary boundaries, dimensions as small as 30 nm, and fully customizable energy landscapes. Our optical characterizations further showcase the potential for implementing tailored optoelectronics in these engineered 2D crystals.

2D materials↗

Ab initio polaritonic potential-energy surfaces for excited-state nanophotonics and polaritonic chemistry

Advances in nanophotonics, quantum optics, and low-dimensional materials have enabled precise control of light–matter interactions down to the nanoscale. Combining concepts from each of these fields, there is now an opportunity to create and manipulate photonic matter via strong coupling of molecules to the electromagnetic field. Toward this goal, here we demonstrate a first principles framework to calculate polaritonic excited-state potential-energy surfaces, transition dipole moments, and transition densities for strongly coupled light–matter systems. In particular, we demonstrate the applicability of our methodology by calculating the polaritonic excited-state manifold of a formaldehyde molecule strongly coupled to an optical cavity. This proof-of-concept calculation shows how strong coupling can be exploited to alter photochemical reaction pathways by influencing avoided crossings with tuning of the cavity frequency and coupling strength. Therefore, by introducing an ab initio method to calculate excited-state potential-energy surfaces, our work opens a new avenue for the field of polaritonic chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Instantaneous difference frequency locking observed during toroidicity-induced Alfvén eigenmode coupling in the DIII-D tokamak

In magnetic confinement fusion, toroidicity-induced Alfvén eigenmodes (TAEs) are well-studied, weakly stable solutions of the linearized ideal magnetohydrodynamic equations. Driven unstable by suprathermal populations of energetic particles, TAE pose a key vulnerability to the confinement of high-energy alpha particles generated by fusion reactions. Hence, it is paramount to understand TAE dynamics if a working reactor is to be realized. In this work, we detect and characterize signatures of nonstationary nonlinear coupling between TAE using a novel, time-resolved bispectral analysis; results are supported by analytic signal of band-passed data. Crucially, a stationary phase relationship between two TAE and a nascent low frequency fluctuation is observed precisely when the triple product of magnetic fluctuation amplitudes is enhanced. Local mode number and frequency spectrum, gleaned from beam-emission spectroscopy, corroborates simultaneous satisfaction of nonlinear matching conditions, and provides a tool to identify theorized pathways of energy transfer, e.g. TAE parametric instability.

bispectral analysis↗

Measurements of time and spatial resolution of AC-LGADs with different designs

AC-LGAD sensors are prime candidates for fast and precise measurement of charged particles in a variety of applications. In a fine-pitched pixel or strip AC-LGAD sensor, the signal generated by the passage of a particle is not localized in a limited volume in the sensor, but is shared among multiple electrodes. This signal sharing characteristic allows us to improve the spatial resolution of AC-LGAD sensors beyond the capabilities of common silicon trackers. Since the magnitude of the shared signal depends on the distance between the pixels or strips and the point of passage of the particle, signal sharing is strongly influenced by the geometry of the sensor. The electrode pitch and gap size as well as the shape can be fine tuned to maximize the space resolution, while keeping the detector granularity and the number of channels to be read out under control. Prototypes of AC-LGAD sensors produced at the Brookhaven National Laboratory covering a variety of possible geometries have been studied via Transient Current Technique using an infrared laser, and the signal sharing, spatial resolution, and time resolution of the different topologies have been measured. These results have been compared with measurements performed in test-beams with 120 GeV protons at the Fermilab Test Beam Facility. A time resolution of ~30 ps can be achieved using AC-LGAD sensors with a thickness of 50 μm, compatible to that of standard DC-coupled LGADs, while presenting a far superior spatial resolution. Finally, this combination of high precision, fast timing capabilities, and low material budget makes AC-LGADs an ideal choice for a truly 4D detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Dark Energy Survey Year 3 and eBOSS: constraining galaxy intrinsic alignments across luminosity and colour space

ABSTRACT We present direct constraints on galaxy intrinsic alignments (IAs) using the Dark Energy Survey Year 3 (DES Y3), the Extended Baryon Oscillation Spectroscopic Survey (eBOSS), and its precursor, the Baryon Oscillation Spectroscopic Survey (BOSS). Our measurements incorporate photometric red sequence (redMaGiC) galaxies from DES with median redshift z ∼ 0.2–1.0, luminous red galaxies from eBOSS at z ∼ 0.8, and also an SDSS-III BOSS CMASS sample at z ∼ 0.5. We measure two-point IA correlations, which we fit using a model that includes lensing, magnification, and photometric redshift error. Fitting on scales 6 Mpc h−1 < rp < 70 Mpc h−1, we make a detection of IAs in each sample, at 5σ–22σ (assuming a simple one-parameter model for IAs). Using these red samples, we measure the IA–luminosity relation. Our results are statistically consistent with previous results, but offer a significant improvement in constraining power, particularly at low luminosity. With this improved precision, we see detectable dependence on colour between broadly defined red samples. It is likely that a more sophisticated approach than a binary red/blue split, which jointly considers colour and luminosity dependence in the IA signal, will be needed in future. We also compare the various signal components at the best-fitting point in parameter space for each sample, and find that magnification and lensing contribute $\sim 2\!-\!18~{{\ \rm per\ cent}}$ of the total signal. As precision continues to improve, it will certainly be necessary to account for these effects in future direct IA measurements. Finally, we make equivalent measurements on a sample of emission-line galaxies from eBOSS at z ∼ 0.8. We constrain the non-linear alignment amplitude to be $A_1=0.07^{+0.32}_{-0.42}$ (|A1| < 0.78 at 95 per cent CL).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Learning Sequential Distribution System Restoration via Graph-Reinforcement Learning

We report a distribution service restoration algorithm as a fundamental resilient paradigm for system operators provides an optimally coordinated, resilient solution to enhance the restoration performance. The restoration problem is formulated to coordinate distribution generators and controllable switches optimally. A model-based control scheme is usually designed to solve this problem, relying on a precise model and resulting in low scalability. To tackle these limitations, this work proposes a graph-reinforcement learning framework for the restoration problem. We link the power system topology with a graph convolutional network, which captures the complex mechanism of network restoration in power networks and understands the mutual interactions among controllable devices. Latent features over graphical power networks produced by graph convolutional layers are exploited to learn the control policy for network restoration using deep reinforcement learning. The solution scalability is guaranteed by modeling distributed generators as agents in a multi-agent environment and a proper pre-training paradigm. Comparative studies on IEEE 123-node and 8500-node test systems demonstrate the performance of the proposed solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SOFIA: Spectrometer Optimized for Facility Integrated Applications

Los Alamos National Laboratory researchers developed the Spectrometer Optimized for Facility Integrated Applications (SOFIA) for new capabilities in non-destructive nuclear material analysis, nuclear data measurements, and actinide science. SOFIA is the first ultra-high resolution gamma spectrometer technology based on low-temperature microcalorimeter designs. By precisely measuring the gamma rays passively emitted from radioactive and nuclear materials, SOFIA provides rapid, completely nondestructive analysis to improve the economics and timeliness of nuclear material analysis by reducing reliance on costly sampling and destructive analysis. By developing the first compact instrument based on ultrahigh resolution microcalorimeter gamma spectroscopy, the researchers intended to bring this technology into practical use in nuclear facilities and analytical laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatio-temporally shaped deep UV laser source for ultrabright photocathodes using novel upconversion techniques (Final Report)

The goal of this project was to take a VUV laser system designed by Kapteyn-Murnane Labs (KMLabs)—the Hyperion VUV, and increase its functionality, efficiency, and applicability by further probing the fundamental physics taking place in the system and optimizing the system performance. More specifically, DOE accelerator applications—particularly for XFELs that require low-emittance electron beams, require precisely controlled ultrashort pulses in the deep-UV at 250-260 nm to drive the photocathode electron source. This is conventionally done using an ultrafast infrared laser, with subsequent stages of nonlinear upconversion in solid-state nonlinear-optical crystal media (principally BBO, which is commonly used for UV upconversion). However, maintaining high spatial mode beam quality, as well as precisely controlled temporal profile, has proven a persistent challenge. As a possible alternative to this approach, KMLabs has demonstrated a system that generates vacuum ultraviolet light (VUV) by upconverting pulses from an infrared ultrafast laser in a gas-filled hollow waveguide, driving a process of highly cascaded harmonic generation (HCHG). Because HCHG upconversion is done in a gas, rather than a solid, at high intensity in a guided-wave geometry, it retains an excellent beam spatial profile as well as a large spectral bandwidth that allows for control over the temperal structure of the pulse. A challenge, however, is in energy scaling of this HCHG technique to the ~1-20 μJ pulses required for photocathode applications. To-date, the pulse energies used in published HCHG work are sub-10-nJ. This project proposed to explore ways to generate higher-energy pulses using HCHG, as well as to investigate spectral and temporal shaping of the deep UV pulses by pulse shaping the infrared laser used to seed the process. Although we showed that our approach works for generating light at 259 nm, the total pulse energy achieved seems limited to approximately the same value as past work. However, the techniques we investigated may well have benefits for extending this source to much shorter wavelength output.

43 PARTICLE ACCELERATORS↗

Water-cooled Helmholtz coil for Ultra-low Magnetic Field Testing

Ultra-low magnetic field testing requires precise and finely calibrated instrumentation interacting with very marginal magnetic fields in highly controlled environments. We designed a large Helmholtz coil system for implementation around a 17.825-inch outer diameter Helium-3 Cryogenic fridge, to serve as both a field-zeroing device and to enable higher resolution on magnetic field sweeps during experiments. We present finite volume modeling and finite element analysis results which indicate the device could safely run at 20 [A] in perpetuity, producing a magnetic field of 65 [mT], without the surface facing the Cryogenic fridge exceeding 50°C. The overall system parts expense is $\$$4,882.76.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Shutoff and throttling valve

Leaktight shutoff, precise flow control, and very low pressure drop are incorporated in all-metal valve designed for operation under extreme temperatures. Valve constructed with refractory metal is intended for control of high-temperature liquid cesium, but has applications related to control of high- and low-temperature liquids and gases.

Hays, L. G.↗

Applications Technology Satellite program

The Applications Technology Satellite (ATS) program has involved geosynchronous spacecraft technology made possible by the increased capability of the Atlas-Agena launch vehicle. The ATS-1-5 program developed spin stabilized and gravity gradient stabilized spacecraft for geosynchronous orbit, earth-oriented antennae for increased antenna gain, earth-scanning meteorological experiments for continuous weather monitoring, and made possible satellite communications to mobile terminals. The ATS-6 program developed a space-deployed, high-gain antenna for color television broadcast to low-cost ground terminals and precise spacecraft attitude control for pointing, slewing, and tracking applications. All of the ATS program objectives were successfully met, except for the gravity gradient experiments. ATS-1, -3, -5, and -6 are in orbit and operational.

Mcceney, P. J.↗