Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Magnetic resonance in a Cu-Cr-S structure

A layered Cu-Cr-S structure composed of single-crystal CuCrS{sub 2} layers and thin CuCr{sub 2}S{sub 4} plates embedded in them has been investigated by the magnetic resonance and scanning electron microscopy methods. The Curie temperature and saturation magnetization of the spinel phase of the investigated samples have been determined. The thickness of the CuCr{sub 2}S{sub 4} layers has been estimated. The dependence of the growncrystal topology on synthesis conditions has been established. An interpretation of the anomalous behavior of the magnetostatic oscillation intensity is offered.

36 MATERIALS SCIENCE↗

Low-Field Nuclear Magnetic Resonance Characterization of Carbonate and Sandstone Reservoirs From Rock Spring Uplift of Wyoming

Laboratory measurements including gas (N 2 ) porosity and permeability, time-domain nuclear magnetic resonance, thin section, and scanning electron microscopy analysis were conducted to obtain petrographical and petrophysical descriptions of the Weber Sandstone and Madison Limestone at the Rock Spring Uplift, a potential carbon dioxide storage site in Southwestern Wyoming. The relationships between pore structures, such as pore geometry, pore-size distribution, pore network, and porosity/permeability are investigated. First, using thin sections combined with scanning electron microscopy for pore structures description, all samples are described in detail from the geological, petrographysical, and diagenetic viewpoint. Results show that within the Madison Limestone, pore types include intercrystalline, vuggy, moldic, or mixed (combination of all other pore types). Both moldic and vuggy pore types are associated with samples of high porosity and permeability. Nuclear magnetic resonance relaxation time distributions show either bimodal or multimodal distributions. Large relaxation time components are associated with samples with large pores, whereas small components are dominated by small pores. The T 2 geometric mean correlates well with gas permeability. Additionally, short-time diffusion coefficients (D) were measured by pulsed field gradient method using a series of gradient strengths. We found that diffusion coefficient distributions correlate with the corresponding T 2 distributions for macropores. By comparing the dominant peak position of T 2 distributions and their corresponding diffusion coefficient distributions, we predicted the surface relaxivity of different rock types. We found that surface relaxivities of Weber Sandstone samples can be well predicted, while for Madison Limestone samples, surface relaxivities are overestimated due to diffusive pore coupling effect.

58 GEOSCIENCES↗

The three-dimensional modeling of plasma edge transport and divertor fluxes during application of resonant magnetic perturbations on ITER

Results from three-dimensional modeling of plasma edge transport and plasma–wall interactions during application of resonant magnetic perturbation (RMP) fields for control of edge-localized modes in the ITER standard 15 MA Q = 10 H-mode are presented. The full 3D plasma fluid and kinetic neutral transport code EMC3-EIRENE is used for the modeling. Four characteristic perturbed magnetic topologies are considered and discussed with reference to the axisymmetric case without RMP fields. Two perturbation field amplitudes at full and half of the ITER ELM control coil current capability using the vacuum approximation are compared to a case including a strongly screening plasma response. In addition, a vacuum field case at high q95 = 4.2 featuring increased magnetic shear has been modeled. Formation of a three-dimensional plasma boundary is seen for all four perturbed magnetic topologies. The resonant field amplitudes and the effective radial magnetic field at the separatrix define the shape and extension of the 3D plasma boundary. Opening of the magnetic field lines from inside the separatrix establishes scrape-off layer-like channels of direct parallel particle and heat flux towards the divertor yielding a reduction of the main plasma thermal and particle confinement. This impact on confinement is most accentuated at full RMP current and is strongly reduced when screened RMP fields are considered, as well as for the reduced coil current cases. The divertor fluxes are redirected into a three-dimensional pattern of helical magnetic footprints on the divertor target tiles. At maximum perturbation strength, these fingers stretch out as far as 60 cm across the divertor targets, yielding heat flux spreading and the reduction of peak heat fluxes by 30%. However, at the same time substantial and highly localized heat fluxes reach divertor areas well outside of the axisymmetric heat flux decay profile. Reduced RMP amplitudes due to screening or reduced RMP coil current yield a reduction of the width of the divertor flux spreading to about 20–25 cm and cause increased peak heat fluxes back to values similar to those in the axisymmetric case. The dependencies of these features on the divertor recycling regime and the perpendicular transport assumptions, as well as toroidal averaged effects mimicking rotation of the RMP field, are discussed in the paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward Prostate Cancer Contouring Guidelines on Magnetic Resonance Imaging: Dominant Lesion Gross and Clinical Target Volume Coverage Via Accurate Histology Fusion

Purpose: Defining prostate cancer (PCa) lesion clinical target volumes (CTVs) for multiparametric magnetic resonance imaging (mpMRI) could support focal boosting or treatment to improve outcomes or lower morbidity, necessitating appropriate CTV margins for mpMRI-defined gross tumor volumes (GTVs). This study aimed to identify CTV margins yielding 95% coverage of PCa tumors for prospective cases with high likelihood. Methods and Materials: Twenty-five men with biopsy-confirmed clinical stage T1 or T2 PCa underwent pre-prostatectomy mpMRI, yielding T2-weighted, dynamic contrast-enhanced, and apparent diffusion coefficient images. Digitized whole-mount histology was contoured and registered to mpMRI scans (error ≤2 mm). Four observers contoured lesion GTVs on each mpMRI scan. CTVs were defined by isotropic and anisotropic expansion from these GTVs and from multiparametric (unioned) GTVs from 2 to 3 scans. Histologic coverage (proportions of tumor area on co-registered histology inside the CTV, measured for Gleason scores [GSs] ≥6 and ≥7) and prostate sparing (proportions of prostate volume outside the CTV) were measured. Nonparametric histologic-coverage prediction intervals defined minimal margins yielding 95% coverage for prospective cases with 78% to 92% likelihood. Results: On analysis of 72 true-positive tumor detections, 95% coverage margins were 9 to 11 mm (GS ≥ 6) and 8 to 10 mm (GS ≥ 7) for single-sequence GTVs and were 8 mm (GS ≥ 6) and 6 mm (GS ≥ 7) for 3-sequence GTVs, yielding CTVs that spared 47% to 81% of prostate tissue for the majority of tumors. Inclusion of T2-weighted contours increased sparing for multiparametric CTVs with 95% coverage margins for GS ≥6, and inclusion of dynamic contrast-enhanced contours increased sparing for GS ≥7. Anisotropic 95% coverage margins increased the sparing proportions to 71% to 86%. Conclusions: Multiparametric magnetic resonance imaging–defined GTVs expanded by appropriate margins may support focal boosting or treatment of PCa; however, these margins, accounting for interobserver and intertumoral variability, may preclude highly conformal CTVs. Multiparametric GTVs and anisotropic margins may reduce the required margins and improve prostate sparing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurements of nematic susceptibility with phase sensitive nuclear magnetic resonance in pulsed strain fields

Here, we present nuclear magnetic resonance data in BaFe 2 As 2 in the presence of pulsed strain fields that are interleaved in time with the radio frequency excitation pulses. In this approach, the preceding nuclear magnetization acquires a phase shift that is proportional to the strain and pulse time. The sensitivity of this approach is limited by the homogeneous decoherence time, T 2 , rather than the inhomogeneous linewidth. We measure the nematic susceptibility as a function of temperature and demonstrate a three orders of magnitude improvement in sensitivity. This approach will enable studies of the strain response in a broad range of materials that previously were inaccessible due to inhomogeneous broadening.

36 MATERIALS SCIENCE↗

Resonant mode effects on rotation braking induced by n = 1 resonant magnetic perturbations in the EAST tokamak

Abstract The spectrum effects on toroidal rotation braking, induced by n = 1 resonant magnetic perturbations (RMPs) in the discharges with q 95 = 4.1 and q 95 = 5.1 , are studied in the EAST tokamak. Here n is the toroidal mode number, RMP spectrum is varied by scanning δ ϕ U L , the phase difference between the upper and lower rows of RMP coils. The toroidal rotation changes periodically with the periodic δ ϕ U L scanning and such an effect is stronger in the discharge with lower q 95 = 4.1 . The spectrum dependence of the neoclassical toroidal viscosity (NTV) torque, modeled by NTVTOK based on the magnetic perturbation obtained from MARS-F calculation, agrees well with that of the experimentally observed braking torques in both discharges. The modeled NTV torque is stronger in the discharge with lower q 95 , which also agrees with the observations. The comparisons between the spectrum dependence of the NTV and magnetic perturbations show that the resonant mode of magnetic perturbations near the plasma edge mainly contribute the NTV torque. These agreements between modeling and experiments highlight the capability of NTV theory in explaining the experimental observation in the EAST tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noncyclic geometric quantum computation in a nuclear-magnetic-resonance system

A scheme is proposed to include both cyclic and noncyclic geometric quantum computations in nuclear-magnetic-resonance system by the invariant theory. By controlling magnetic field and arbitrary parameters in the invariant operator, the phases accumulated in the entangling quantum gates for single- and two-qubit systems are pure geometric phases. Thus, fault tolerance may occur in some critical magnetic field parameters for either cyclic or noncyclic evolution by differently choosing for gate time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Metabolic biomarkers for non-alcoholic fatty liver disease induced by high-fat diet: In vivo magnetic resonance spectroscopy of hyperpolarized [1-{sup 13}C] pyruvate

Hyperpolarized {sup 13}C magnetic resonance spectroscopy (MRS) to assess hepatic metabolism in non-alcoholic fatty liver disease (NAFLD) has not been reported. This study searched for cellular metabolism-based biomarkers for NAFLD induced by a high-fat diet (HFD) in rats. Also, correlations of the biomarkers with enzyme levels and histopathology were identified during a 6-week follow-up. Six rats were fed a control diet (CD) and seven rats were fed the HFD for 6 weeks. Hyperpolarized {sup 13}C dynamic MRS was performed on rat liver following an injection of hyperpolarized [1-{sup 13}C] pyruvate. Compared with CD-fed rats, HFD-fed rats showed significant increases in the levels of serum alanine aminotransferase and low-density lipoprotein cholesterol at weeks 4 and 6 of follow-up. After the 6-week HFD, the ratios of [1-{sup 13}C] alanine/pyruvate and [1-{sup 13}C] lactate/pyruvate were significantly increased, as were the levels of alanine aminotransferase and lactate dehydrogenase, which are potentially associated with hepatosteatosis. The results implicate [1-{sup 13}C] alanine and [1-{sup 13}C] lactate as potentially useful noninvasive biomarkers of hepatosteatosis occurring in NAFLD. - Highlights: • Hyperpolarized {sup 13}C-alanine and lactate are noninvasive biomarkers on hepatosteatosis. • During the course of HFD feeding, {sup 13}C-alanine and lactate were increased in HFD-rats. • Hyperpolarized {sup 13}C dynamic MRS will be helpful to monitor the progression of NAFLD.

60 APPLIED LIFE SCIENCES↗

Evaluation of muscle injury using magnetic resonance imaging

The objective of this study was to investigate spin echo T2 relaxation time changes in thigh muscles after intense eccentric exercise in healthy men. Spin echo and calculated T2 relaxation time images of the thighs were obtained on several occasions after exercise of one limb; the contralateral limb served as control. Muscle damage was verified by elevated levels of serum creatine kinase (CK). Thirty percent of the time no exercise effect was discernible on the magnetic resonance (MR) images. In all positive MR images (70%) the semitendinosus muscle was positive, while the biceps femoris, short head, and gracilis muscles were also positive in 50% and 25% of the total cases, respectively. The peak T2 relaxation time and serum CK were correlated (r = 0.94, p<0.01); temporal changes in muscle T2 relaxation time and serum CK were similar, although T2 relaxation time remained positive after serum CK returned to background levels. We conclude that magnetic resonance imaging can serve as a useful tool in the evaluation of eccentric exercise muscle damage by providing a quantitative indicator of damage and its resolution as well as the specific areas and muscles.

NASA Discipline Number 26-10↗

Superconducting quantum interference device microsusceptometer balanced over a wide bandwidth for nuclear magnetic resonance applications

Superconducting Quantum Interference Device (SQUID) microsusceptometers have been widely used to study magnetic properties of materials at microscale. As intrinsically balanced devices, they could also be exploited for direct SQUID-detection of nuclear magnetic resonance (NMR) from micron sized samples, or for SQUID readout of mechanically detected NMR from submicron sized samples. Here, we demonstrate a double balancing technique that enables achievement of very low residual imbalance of a SQUID microsusceptometer over a wide bandwidth. In particular, we can generate ac magnetic fields within the SQUID loop as large as 1 mT, for frequencies ranging from dc up to a few MHz. As an application, we demonstrate direct detection of NMR from {sup 1}H spins in a glycerol droplet placed directly on top of the 20 μm SQUID loops.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alkali-vapor magnetic resonance driven by fictitious radiofrequency fields

We demonstrate an all-optical {sup 133}Cs scalar magnetometer, operating in nonzero magnetic field, in which the magnetic resonance is driven by an effective oscillating magnetic field provided by the AC Stark shift of an intensity-modulated laser beam. We achieve a projected shot-noise-limited sensitivity of 1.7fT/√(Hz) and measure a technical noise floor of 40fT/√(Hz). These results are essentially identical to a coil-driven scalar magnetometer using the same setup. This all-optical scheme offers advantages over traditional coil-driven magnetometers for use in arrays and in magnetically sensitive fundamental physics experiments, e.g., searches for a permanent electric dipole moment of the neutron.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In vivo nuclear magnetic resonance imaging

During the past year the Woodlands Baylor Magnetic Resonance Imaging (MRI) facility became fully operational. A detailed description of this facility is given. One significant instrument addition this year was the 100 MHz, 40cm bore superconducting imaging spectrometer. This instrument gives researchers the capability to acquire high energy phosphate spectra. This will be used to investigate ATP, phosphocreatinine and inorganic phosphate changes in normal and atrophied muscle before, during and after exercise. An exercise device for use within the bore of the imaging magnet is under design/construction. The results of a study of T sub 1 and T sub 2 changes in atrophied muscle in animals and human subjects are given. The imaging and analysis of the lower leg of 15 research subjects before and after 5 weeks of complete bedrest was completed. A compilation of these results are attached.

Leblanc, A.↗

The safety of magnetic resonance imaging contrast agents

Gadolinium-based contrast agents are increasingly used in clinical practice. While these pharmaceuticals are verified causal agents in nephrogenic systemic fibrosis, there is a growing body of literature supporting their role as causal agents in symptoms associated with gadolinium exposure after intravenous use and encephalopathy following intrathecal administration. Gadolinium-based contrast agents are multidentate organic ligands that strongly bind the metal ion to reduce the toxicity of the metal. The notion that cationic gadolinium dissociates from these chelates and causes the disease is prevalent among patients and providers. We hypothesize that non-ligand-bound (soluble) gadolinium will be exceedingly low in patients. Soluble, ionic gadolinium is not likely to be the initial step in mediating any disease. The Kidney Institute of New Mexico was the first to identify gadolinium-rich nanoparticles in skin and kidney tissues from magnetic resonance imaging contrast agents in rodents. In 2023, they found similar nanoparticles in the kidney cells of humans with normal renal function, likely from contrast agents. We suspect these nanoparticles are the mediators of chronic toxicity from magnetic resonance imaging contrast agents. This article explores associations between gadolinium contrast and adverse health outcomes supported by clinical reports and rodent models.

59 BASIC BIOLOGICAL SCIENCES↗

Antiferromagnetic spin correlations and pseudogaplike behavior in Ca(Fe 1-x Co x ) 2 As 2 studied by 75 As nuclear magnetic resonance and anisotropic resistivity

We report 75 As nuclear magnetic resonance (NMR) measurements of single-crystalline Ca(Fe 1–x Co x ) 2 As 2 (x=0.023, 0.028, 0.033, and 0.059) annealed at 350°C for 7 days. From the observation of a characteristic shape of 75 As NMR spectra in the stripe-type antiferromagnetic (AFM) state, as in the case of x=0 (T N =170 K), clear evidence for the commensurate AFM phase transition with the concomitant structural phase transition is observed in x=0.023 (T N =106 K) and x=0.028 (T N =53 K). Through the temperature dependence of the Knight shifts and the nuclear spin lattice relaxation rates (1/T 1 ), although stripe-type AFM spin fluctuations are realized in the paramagnetic state as in the case of other iron pnictide superconductors, we found a gradual decrease of the AFM spin fluctuations below a crossover temperature T* that was nearly independent of Co-substitution concentration, and it is attributed to a pseudogaplike behavior in the spin excitation spectra of these systems. The T* feature finds correlation with features in the temperature-dependent interplane resistivity, ρ c (T), but not with the in-plane resistivity ρ a (T). The temperature evolution of anisotropic stripe-type AFM spin fluctuations is tracked in the paramagnetic and pseudogap phases by the 1/T 1 data measured under magnetic fields parallel and perpendicular to the c axis. As a result, based on our NMR data, we have added a pseudogaplike phase to the magnetic and electronic phase diagram of Ca(Fe 1–x Co x ) 2 As 2 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of elastic interactions in GaAs/Si composites by optically pumped nuclear magnetic resonance

Elastic interactions in GaAs/Si bilayer composite structures were studied by optically pumped nuclear magnetic resonance (OPNMR). The composites were fabricated by epoxy bonding of a single crystal of GaAs to a single crystal of Si at 373 K followed by selective chemical etching of the GaAs at room temperature to obtain a series of samples with GaAs thickness varying from 37 μm to 635 μm, while the Si support thickness remained fixed at 650 μm. Upon cooling to below 10 K, a biaxial tensile stress developed in the GaAs film due to differential thermal contraction. The strain perpendicular to the plane of the bilayer and localized near the surface of the GaAs was deduced from the quadrupolar splitting of the Gallium-71 OPNMR resonance. Strain relaxation by bowing of the composite was observed to an extent that depended on the relative thickness of the GaAs and Si layers. The variation of the strain with GaAs layer thickness was found to be in good agreement with a general analytical model for the elastic relationships in composite media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of Magnetic Resonances in Electron Clouds in a Positron Storage Ring

The first experimental observation of magnetic resonances in electron clouds is reported. The resonance was observed as a modulation in cloud intensity for uncoated as well as TiN-coated aluminum surfaces in the positron storage ring of the PEP-II collider at SLAC. Electron clouds frequently arise in accelerators of positively charged particles, and severely impact the machines performance. The TiN coating was found to be an effective remedy, reducing the cloud intensity by three orders of magnitude.

43 PARTICLE ACCELERATORS↗

A Comparison of Rapid-Scanning X-Ray Fluorescence Mapping And Magnetic Resonance Imaging to Localize Brain Iron Distribution

The clinical diagnosis of many neurodegenerative disorders relies primarily or exclusively on observed behaviors rather than measurable physical tests. One of the hallmarks of Alzheimer disease (AD) is the presence of amyloid-containing plaques associated with deposits of iron, copper and/or zinc. Work in other laboratories has shown that iron-rich plaques can be seen in the mouse brain in vivo with magnetic resonance imaging (MRI) using a high-field strength magnet but this iron cannot be visualized in humans using clinical magnets. To improve the interpretation of MRI, we correlated iron accumulation visualized by X-ray fluorescence spectroscopy, an element-specific technique with T1, T2, and susceptibility weighted MR (SWI) in a mouse model of AD. We show that SWI best shows areas of increased iron accumulation when compared to standard sequences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

[Measurement of left atrial and ventricular volumes in real-time 3D echocardiography. Validation by nuclear magnetic resonance]

The measurement of the left ventricular ejection fraction is important for the evaluation of cardiomyopathy and depends on the measurement of left ventricular volumes. There are no existing conventional echocardiographic means of measuring the true left atrial and ventricular volumes without mathematical approximations. The aim of this study was to test anew real time 3-dimensional echocardiographic system of calculating left atrial and ventricular volumes in 40 patients after in vitro validation. The volumes of the left atrium and ventricle acquired from real time 3-D echocardiography in the apical view, were calculated in 7 sections parallel to the surface of the probe and compared with atrial (10 patients) and ventricular (30 patients) volumes calculated by nuclear magnetic resonance with the simpson method and with volumes of water in balloons placed in a cistern. Linear regression analysis showed an excellent correlation between the real volume of water in the balloons and volumes given in real time 3-dimensional echocardiography (y = 0.94x + 5.5, r = 0.99, p < 0.001, D = -10 +/- 4.5 ml). A good correlation was observed between real time 3-dimensional echocardiography and nuclear magnetic resonance for the measurement of left atrial and ventricular volumes (y = 0.95x - 10, r = 0.91, p < 0.001, D = -14.8 +/- 19.5 ml and y = 0.87x + 10, r = 0.98, P < 0.001, D = -8.3 +/- 18.7 ml, respectively. The authors conclude that real time three-dimensional echocardiography allows accurate measurement of left heart volumes underlying the clinical potential of this new 3-D method.

Non-NASA Center↗