Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Locally Advanced Prostate Cancer: Three-Dimensional Magnetic Resonance Spectroscopy to Monitor Prostate Response to Therapy

Purpose: To correlate results of three-dimensional magnetic resonance spectroscopic imaging (MRSI) with prostate-specific antigen (PSA) levels and time since external beam irradiation (EBRT) in patients treated with long-term hormone therapy (HT) and EBRT for locally advanced disease to verify successful treatment by documenting the achievement of metabolic atrophy (MA). Methods and Materials: Between 2006 and 2008, 109 patients were consecutively enrolled. MA was assessed by choline and citrate peak area-to-noise-ratio <5:1. Cancerous metabolism (CM) was defined by choline-to-creatine ratio >1.5:1 or choline signal-to-noise-ratio >5:1. To test the strength of association between MRSI results and the time elapsed since EBRT (TEFRT), PSA levels, Gleason score (GS), and stage, logistic regression (LR) was performed. p value <0.05 was statistically significant. The patients' outcomes were verified in 2011. Results: MRSI documented MA in 84 of 109 and CM in 25 of 109 cases. LR showed that age, GS, stage, and initial and recent PSA had no significant impact on MRSI results which were significantly related to PSA values at the time of MRSI and to TEFRT. Patients were divided into three groups according to TEFRT: <1 year, 1-2 years, and >2 years. MA was detected in 54.1% of patients of group 1, 88.9% of group 2, and in 94.5% of group 3 (100% when PSA nadir was reached). CM was detected in 50% of patients with reached PSA nadir in group 1. Local relapse was found in 3 patients previously showing CM at long TEFRT. Conclusion: MA detection, indicative of successful treatment because growth of normal or abnormal cells cannot occur without metabolism, increases with decreasing PSA levels and increasing time on HT after EBRT. This supports long-term HT in advanced prostate cancer. Larger study series are needed to assess whether MRSI could predict local relapse by detecting CM at long TEFRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear magnetic resonance investigation of the heavy fermion system Ce 2 CoAl 7 Ge 4

We present here nuclear magnetic resonance (NMR) and nuclear quadrupole resonance (NQR) measurements performed on single crystalline ${\mathrm{Ce}}_{2}{\mathrm{CoAl}}_{7}{\mathrm{Ge}}_{4}$, a member of a recently discovered family of heavy fermion materials ${\mathrm{Ce}}_{2}M{\mathrm{Al}}_{7}{\mathrm{Ge}}_{4}$ ($M=\mathrm{Co}$, Ir, Ni, or Pd). Previous measurements indicated a strong Kondo interaction as well as magnetic order below ${T}_{M}=1.8\mathrm{K}$. Our NMR spectral measurements show that the Knight shift $K$ is proportional to the bulk magnetic susceptibility ${\chi}$ at high temperatures. A clear Knight shift anomaly ($K\neg{}{\propto}{\chi}$) is observed at coherence temperatures ${T}^{*}{\sim}17.5\mathrm{K}$ for ${H}_{0}{\parallel}\stackrel{\hat{}{}{}}{c}$ and 10 K for ${H}_{0}{\parallel}\stackrel{\hat{}{}{}}{a}$ at the $^{59}\mathrm{Co}$ site, and ${T}^{*}{\sim}12.5\mathrm{K}$ at the $^{27}\mathrm{Al}$(3) site for ${H}_{0}{\parallel}\stackrel{\hat{}{}{}}{a}$ characteristic of the heavy fermion nature of this compound. At high temperatures, the $^{59}\mathrm{Co}$ NMR spin-lattice relaxation rate ${T}_{1}^{{-}1}$ is dominated by spin fluctuations of the $4f$ local moments with a weak metallic background. The spin fluctuations probed by $^{59}\mathrm{Co}$ NMR are anisotropic and larger in the basal plane than in the $c$ direction. Furthermore, we find ${({T}_{1}TK)}^{{-}1}{\propto}{T}^{{-}1/2}$ at the $^{59}\mathrm{Co}$ site as expected for a Kondo system for $T>{T}^{*}$ and $T>{T}_{K}$. $^{59}\mathrm{Co}$ NQR ${T}_{1}^{{-}1}$ measurements at low temperatures indicate slowing down of spin fluctuations above the magnetic ordering temperature ${T}_{M}{\sim}1.8\mathrm{K}$. A weak ferromagnetic character of fluctuations around $\mathbf{q}=0$ is evidenced by an increase of ${\chi}T$ versus $T$ above the magnetic ordering temperature. We also find good agreement between the observed and calculated electric field gradients at all observed sites.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessment of Tumor Response to the Vascular Disrupting Agents 5,6-Dimethylxanthenone-4-Acetic Acid or Combretastatin-A4-Phosphate by Intrinsic Susceptibility Magnetic Resonance Imaging

Purpose: To investigate the use of the transverse magnetic resonance imaging (MRI) relaxation rate R{sub 2}* (s{sup -1}) as a biomarker of tumor vascular response to monitor vascular disrupting agent (VDA) therapy. Methods and Materials: Multigradient echo MRI was used to quantify R{sub 2}* in rat GH3 prolactinomas. R{sub 2}* is a sensitive index of deoxyhemoglobin in the blood and can therefore be used to give an index of tissue oxygenation. Tumor R{sub 2}* was measured before and up to 35 min after treatment, and 24 h after treatment with either 350 mg/kg 5,6-dimethylxanthenone-4-acetic acid (DMXAA) or 100 mg/kg combretastatin-A4-phosphate (CA4P). After acquisition of the MRI data, functional tumor blood vessels remaining after VDA treatment were quantified using fluorescence microscopy of the perfusion marker Hoechst 33342. Results: DMXAA induced a transient, significant (p < 0.05) increase in tumor R{sub 2}* 7 min after treatment, whereas CA4P induced no significant changes in tumor R{sub 2}* over the first 35 min. Twenty-four hours after treatment, some DMXAA-treated tumors demonstrated a decrease in R{sub 2}*, but overall, reduction in R{sub 2}* was not significant for this cohort. Tumors treated with CA4P showed a significant (p < 0.05) reduction in R{sub 2}* 24 h after treatment. The degree of Hoechst 33342 uptake was associated with the degree of R{sub 2}* reduction at 24 h for both agents. Conclusions: The reduction in tumor R{sub 2}* or deoxyhemoglobin levels 24 h after VDA treatment was a result of reduced blood volume caused by prolonged vascular collapse. Our results suggest that DMXAA was less effective than CA4P in this rat tumor model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transient electrically detected magnetic resonance spectroscopy applied to organic solar cells

The influence of light-induced paramagnetic states on the photocurrent generated by polymer:fullerene solar cells is studied using spin-sensitive techniques in combination with laser-flash excitation. For this purpose, we developed a setup that allows for simultaneous detection of transient electron paramagnetic resonance as well as transient electrically detected magnetic resonance (trEDMR) signals from fully processed and encapsulated solar cells. Combining both techniques provides a direct link between photoinduced triplet excitons, charge transfer states, and free charge carriers as well as their influence on the photocurrent generated by organic photovoltaic devices. Our results obtained from solar cells based on poly(3-hexylthiophene) as electron donor and a fullerene-based electron acceptor show that the resonant signals observed in low-temperature (T = 80 K) trEDMR spectra can be attributed to positive polarons in the polymer as well as negative polarons in the fullerene phase, indicating that both centers are involved in spin-dependent processes that directly influence the photocurrent.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Further modeling of q 95 windows for the suppression of edge localized modes by resonant magnetic perturbations in the DIII-D tokamak

An improved resonant plasma response model that more accurately captures the physics of the interaction between a tokamak plasma and a resonant magnetic perturbation (RMP) is developed. The model interpolates between the linear and the nonlinear response regimes and takes into account the fact that the slip-frequency is non-zero in the nonlinear regime. The improved model is incorporated into the extended perturbed equilibrium code (EPEC) toroidal asymptotic matching code. The modified EPEC code is used to investigate RMP-induced edge-localized-mode (ELM) suppression in DIII-D H-mode discharge #145380. Somewhat surprisingly, allowing for a finite slip-frequency (i.e., relaxing the so-called no-slip constraint) is found to only slightly facilitate the locking of driven magnetic island chains to the RMP, and, hence, to only slightly facilitate RMP-induced ELM suppression. This is true despite the fact that the nature of non-locked island solutions is radically different when the no-slip constraint is imposed compared to when it is relaxed (in the first case, the widths of the island chains driven at the rational surfaces pulsate, and in the second case, they remain steady). The previously obtained conclusion that the response of a typical H-mode tokamak plasma to an RMP cannot be accurately modeled by linear theory is confirmed. Here, the previously obtained conclusion that the best agreement between theory and observations is achieved by assuming that the natural frequencies of tearing modes, in the absence of the RMP, are determined by the local equilibrium E × B velocity is also confirmed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-linear MHD modelling of edge localized modes suppression by resonant magnetic perturbations in ITER

Edge localized modes (ELMs) suppression by resonant magnetic perturbations (RMPs) was studied with the non-linear magneto-hydro-dynamic (MHD) code JOREK for the ITER H-mode scenarios at 15 MA, 12.5 MA, 10 MA/5.3 T. In this study, the main aim was to demonstrate that ELMs can be suppressed by RMPs while the divertor 3D footprints of heat and particle fluxes remain within divertor material limits. The unstable peeling–ballooning modes responsible for ELMs without RMPs were modelled first for each scenario using numerically accessible parameters for ITER. Then the stabilization of ELMs by RMPs was modelled with the same parameters. RMP spectra, optimized by the linear MHD MARS-F code, with main toroidal harmonics N = 2, N = 3, N = 4 have been used as boundary conditions of the computational domain of JOREK, including realistic RMP coils, main plasma, scrape off layer (SOL) divertor and realistic first wall. The model includes all relevant plasma flows: toroidal rotation, two fluid diamagnetic effects and neoclassical poloidal friction. With RMPs, the main toroidal harmonic and the non-linearly coupled harmonics remain dominant at the plasma edge, producing saturated modes and a continuous MHD turbulent transport thereby avoiding ELM crashes in all scenarios considered here. The threshold for ELM suppression was found at a maximum RMP coils current of 45 kAt–60 kAt compared to the coils maximum capability of 90 kAt. In the high beta poloidal steady-state 10 MA/5.3 T scenario, a rotating QH-mode without ELMs was observed even without RMPs. In this scenario with RMPs N = 3, N = 4 at 20 kAt maximum current in RMP coils, similar QH-mode behaviour was observed however with dominant edge harmonic corresponding to the main toroidal number of RMPs. The present MHD modelling was limited in time by few tens of ms after RMPs were switched on until the magnetic energy of the modes saturates. As a consequence the thermal energy was still evolving on this time scale, far from the ITER confinement time scale and hence only the form of 3D footprints on the divertor targets can be indicated within this set-up. Also note, that the divertor physics was missing in this model, so realistic values of fluxes are out of reach in this modelling. However the stationary 3D divertor and particle fluxes could be simply extrapolated from these results to the stationary situation considering that a large power fraction should be radiated in the core and SOL and only about 50 MW power is going to the divertor, which is an arbitrary, but reasonable number used here. The 3D footprints with RMPs show the characteristic splitting with the main RMP toroidal symmetry. The maximum radial extension of the footprints typically was ~20 cm in inner divertor and ~40 cm in outer divertor with stationary heat fluxes decreasing further out from the initial strike point from ~5 MW m ₋2 to ~1 MW m ₋2 assuming a total power in the divertor and walls is 50 MW. The heat fluxes remain within the divertor target and baffle areas, however with rather small margin in the outer divertor which could be an issue for the first wall especially in transient regimes when part of the plasma thermal energy is released due to switching on the RMP coils. This fact should be considered when RMPs are applied with a more favorable application before or soon after the L–H transition, although optimization is required to avoid increasing the L–H power threshold with RMPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Resonance Imaging-Defined Treatment Margins in Iodine-125 Prostate Brachytherapy

Purpose: Low-dose-rate prostate brachytherapy achieves a very high and effective intraprostatic dose. Implant quality parameters concentrate on the dose received by the prostate (D90, V100) but not that received by the periprostatic tissue. We calculated implant quality parameters, D90 and V100, for the magnetic resonance imaging (MRI)-defined prostate plus 2, 3, and 5 mm. Methods and Materials: A total of 131 men with early-stage prostate cancer treated with iodine-125 brachytherapy represent all those treated with brachytherapy monotherapy in our institution in 2005. Postplan assessment was performed at 1 month using magnetic resonance (MR)-computed tomography (CT) fusion. The prostate V100 and D90 were calculated with 2-, 3-, and 5-mm margins. Results were compared with those in 8 patients with biopsy-proven local failure occurring in an experience of more than 1,100 implants. Results: Mean prostate V100 (SD) and D90 (SD) were 95.6% (4.1) and 117.2% (12.7). For prostate plus a 2-mm margin the D90 was 107.9% (14.3) and for a 3-mm margin 96.0 % (14.0). For prostate plus a 5-mm margin, the D90 was only 78.4% (11.0). The 8 patients experiencing local failure, despite adequate implants, had a lower mean V100 of 91.2% (SD, 2.8; p = 0.0008) and D90 of 103.7% (SD, 8.3; p = 0.002) and significantly inferior margin coverage. Conclusions: Satisfactory coverage of a 2-mm and 3-mm periprostatic margin is obtained with the described planning approach. Coverage falls off significantly by 5 mm. The 8 patients who experienced local failure had significantly lower doses than the margin cohort. Although the V100 and D90 would be considered acceptable, the fall-off in margin coverage was observed by 3 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assurance Issues for Computed Tomography-, Ultrasound-, and Magnetic Resonance Imaging-Guided Brachytherapy

The requirements of quality assurance (QA) for both brachytherapy and imaging devices are well-defined, but image-guided brachytherapy has raised new issues. Image guidance in brachytherapy involves the transition from reference point dosimetry using films to volumetric imaging such as computed tomography, ultrasonography, and magnetic resonance imaging for treatment planning and guidance of applicator, needle, or seed placement. The QA of these devices might not reflect the conditions of use in brachytherapy or the requirements of brachytherapy treatment planning. Image interpretation becomes much more important with image-guided brachytherapy. The success of a procedure could depend on the interpretation of a single image in a calibration phase done under the time pressures of the operative setting. This change has implications at the level of treatment, the process, and the field of brachytherapy as a whole. The QA concerns arising from brachytherapy procedures using ultrasound, computed tomography, and magnetic resonance imaging guidance are discussed, as are the problems associated with using imaging in an interventional setting. This report was intended to indicate the QA concerns arising from the convergence of brachytherapy and imaging-highlighting areas in which technical improvements are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overview of the Magnetic Resonance Capabilities at INL

The aim of this presentation is to give a broad overview of the magnetic resonance capabilities at Idaho National Laboratory and how the technique is implemented within the different directorates at the lab. Historically, the high-field NMR instrumentation has been used by our Energy & Environment Science and Technology (EES&T) directorate primarily as a characterization tool for synthetic chemistry work, but we have been actively trying to expand the use of the instrumentation into our Nuclear Science and Technology (NS&T) and National and Homeland Security (NHS) directorates. The expanded scope of work has ranged from solid-state characterization of biomass, analysis of electrolyte materials from lithium ion batteries, quantification of extracted critical materials, and measurement of metal-ligand complexes using ligands proposed for use in the nuclear fuel cycle.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Magnetic resonance imaging of the placenta and gravid uterus: a pictorial essay

The placenta is commonly overlooked on magnetic resonance imaging of the pregnant patient, which is frequently performed for alternative reasons such as to characterize fetal or uterine anomalies or to investigate the etiology of acute pelvic pain in pregnancy. Placental disorders have potential for significant maternal and fetal morbidity and peripartum complications if not recognized and treated in a timely manner. The radiologist must be familiar with normal placental variants and the spectrum of benign to life-threatening conditions affecting the placenta so that the Obstetrician can be promptly notified and patient management altered, if necessary. In this pictorial essay, we will describe our MR protocol for placental imaging, provide an image-rich review of the normal placenta, placental variants, and a variety of pathological conditions affecting the placenta and gravid uterus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reynolds stress tensor measurements using magnetic resonance velocimetry: expansion of the dynamic measurement range and analysis of systematic measurement errors

This study presents magnetic resonance velocimetry (MRV) Reynolds Stress measurements in a periodic hill channel with a hill Reynolds number of Re = 29,500. The velocity encoding scheme is based on the ICOSA6 method with six icosahedral encoding directions and multiple encoding values are measured to increase the dynamic range. The full Reynolds stress tensor is obtained from a voxel-wise three-dimensional Gaussian fit using the magnitude data of all acquisitions. The MRV results are compared to a wall-resolved large eddy simulation and laser Doppler velocimetry measurements conducted in the same channel. It is shown that the MRV Reynolds stress data have excellent precision and agree qualitatively with the reference data. However, there are apparent systematic deviations. One of the most prominent error contributions is the signal attenuation caused by higher orders of motion, which leads to an overestimation of the turbulence level. Another fundamental error is identified in the assumption that the turbulence is Gaussian distributed. With the presented reconstruction technique, the MRV data are fitted to a statistical model, and depending on the examined flow setup, the Gaussian model can lead to considerable errors. Possible ways of how to reduce all identified errors are presented. In summary, this technique enables Reynolds stress tensor measurements in complex internal flows with high dynamic range and excellent precision. However, several issues need to be resolved to make the turbulence quantification more accurate.

42 ENGINEERING↗

Online Magnetic Resonance Image Guided Adaptive Radiation Therapy: First Clinical Applications

Purpose: To demonstrate the feasibility of online adaptive magnetic resonance (MR) image guided radiation therapy (MR-IGRT) through reporting of our initial clinical experience and workflow considerations. Methods and Materials: The first clinically deployed online adaptive MR-IGRT system consisted of a split 0.35T MR scanner straddling a ring gantry with 3 multileaf collimator-equipped {sup 60}Co heads. The unit is supported by a Monte Carlo–based treatment planning system that allows real-time adaptive planning with the patient on the table. All patients undergo computed tomography and MR imaging (MRI) simulation for initial treatment planning. A volumetric MRI scan is acquired for each patient at the daily treatment setup. Deformable registration is performed using the planning computed tomography data set, which allows for the transfer of the initial contours and the electron density map to the daily MRI scan. The deformed electron density map is then used to recalculate the original plan on the daily MRI scan for physician evaluation. Recontouring and plan reoptimization are performed when required, and patient-specific quality assurance (QA) is performed using an independent in-house software system. Results: The first online adaptive MR-IGRT treatments consisted of 5 patients with abdominopelvic malignancies. The clinical setting included neoadjuvant colorectal (n=3), unresectable gastric (n=1), and unresectable pheochromocytoma (n=1). Recontouring and reoptimization were deemed necessary for 3 of 5 patients, and the initial plan was deemed sufficient for 2 of the 5 patients. The reasons for plan adaptation included tumor progression or regression and a change in small bowel anatomy. In a subsequently expanded cohort of 170 fractions (20 patients), 52 fractions (30.6%) were reoptimized online, and 92 fractions (54.1%) were treated with an online-adapted or previously adapted plan. The median time for recontouring, reoptimization, and QA was 26 minutes. Conclusion: Online adaptive MR-IGRT has been successfully implemented with planning and QA workflow suitable for routine clinical application. Clinical trials are in development to formally evaluate adaptive treatments for a variety of disease sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Plasma currents induced by resonant magnetic field perturbations in tokamaks

The plasma response on externally applied resonant magnetic field perturbations is studied by means of numerical simulations. It is shown that dependent on collisionality and perturbation strength, plasma currents build up which can compensate the external field. These plasma currents are accompanied by out-of-phase currents and poloidal flows at the resonant surfaces. With an increasing perturbation field the screening of the externally applied field decreases and at a certain level, the vacuum field approximation holds for the total magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial Precision in Magnetic Resonance Imaging–Guided Radiation Therapy: The Role of Geometric Distortion

Because magnetic resonance imaging–guided radiation therapy (MRIgRT) offers exquisite soft tissue contrast and the ability to image tissues in arbitrary planes, the interest in this technology has increased dramatically in recent years. However, intrinsic geometric distortion stemming from both the system hardware and the magnetic properties of the patient affects MR images and compromises the spatial integrity of MRI-based radiation treatment planning, given that for real-time MRIgRT, precision within 2 mm is desired. In this article, we discuss the causes of geometric distortion, describe some well-known distortion correction algorithms, and review geometric distortion measurements from 12 studies, while taking into account relevant imaging parameters. Eleven of the studies reported phantom measurements quantifying system-dependent geometric distortion, while 2 studies reported simulation data quantifying magnetic susceptibility–induced geometric distortion. Of the 11 studies investigating system-dependent geometric distortion, 5 reported maximum measurements less than 2 mm. The simulation studies demonstrated that magnetic susceptibility–induced distortion is typically smaller than system-dependent distortion but still nonnegligible, with maximum distortion ranging from 2.1 to 2.6 mm at a field strength of 1.5 T. As expected, anatomic landmarks containing interfaces between air and soft tissue had the largest distortions. The evidence indicates that geometric distortion reduces the spatial integrity of MRI-based radiation treatment planning and likely diminishes the efficacy of MRIgRT. Better phantom measurement techniques and more effective distortion correction algorithms are needed to achieve the desired spatial precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enabling Real-Time Volume Rendering of Functional Magnetic Resonance Imaging on an iOS Device

Powerful non-invasive imaging technologies like computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI) are used daily by medical professionals to diagnose and treat patients. While 2D slice viewers have long been the standard, many tools allowing 3D representations of digital medical data are now available. The newest imaging advancement, functional MRI (fMRI) technology, has changed medical imaging from viewing static to dynamic physiology (4D) over time, particularly to study brain activity. Add this to the rapid adoption of mobile devices for everyday work and the need to visualize fMRI data on tablets or smartphones arises. However, there are few mobile tools available to visualize 3D MRI data, let alone 4D fMRI data. Building volume rendering tools on mobile devices to visualize 3D and 4D medical data is challenging given the limited computational power of the devices. This paper describes research that explored the feasibility of performing real-time 3D and 4D volume raycasting on a tablet device. The prototype application was tested on a 9.7” iPad Pro using two different fMRI datasets of brain activity. The results show that mobile raycasting is able to achieve between 20 and 40 frames per second for traditional 3D datasets, depending on the sampling interval, and up to 9 frames per second for 4D data. While the prototype application did not always achieve true real-time interaction, these results clearly demonstrated that visualizing 3D and 4D digital medical data is feasible with a properly constructed software framework.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mid-Range Coil Array for Magnetic Resonance Imaging of Small Animals

The vast majority of articles on MRI RF coils over the past two decades have focused on large coils, where sample losses dominate, or on micro-coils, where sample and capacitor losses are negligible. Few have addressed the mid-range coils, seen in the majority of small-animal applications, where all the sources of loss are important, for example, mouse brain and body coils from 125 to 750 MHz. We developed a four-saddle coil array for magnetic resonance imaging of small animals. The saddle coil elements in the array were evenly distributed to cover the rat's head. The coil array was tuned to the resonant frequency of 170 MHz. Due to the close proximity of the coil elements, it was necessary to decouple the coil array using nonmagnetic trimmers and, it was operated in the transceiver mode and quadrature-driven. To test the coil array performance at high field, phantom images were acquired with our saddle coil array and standard pulse sequences on a research-dedicated 4 Tesla scanner. Ex vivo brain images of a rat were also acquired, and proved the feasibility of the scaled version of a saddle coil array and, its compatibility with standard pulse sequences when used in a high field magnetic resonance imager.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toxicometabolomics approach to urinary biomarkers for mercuric chloride (HgCl{sub 2})-induced nephrotoxicity using proton nuclear magnetic resonance ({sup 1}H NMR) in rats

The primary objective of this study was to determine and characterize surrogate biomarkers that can predict nephrotoxicity induced by mercuric chloride (HgCl{sub 2}) using urinary proton nuclear magnetic resonance ({sup 1}H NMR) spectral data. A procedure for {sup 1}H NMR urinalysis using pattern recognition was proposed to evaluate nephrotoxicity induced by HgCl{sub 2} in Sprague-Dawley rats. HgCl{sub 2} at 0.1 or 0.75 mg/kg was administered intraperitoneally (i.p.), and urine was collected every 24 h for 6 days. Animals (n = 6 per group) were sacrificed 3 or 6 days post-dosing in order to perform clinical blood chemistry tests and histopathologic examinations. Urinary {sup 1}H NMR spectroscopy revealed apparent differential clustering between the control and HgCl{sub 2} treatment groups as evidenced by principal component analysis (PCA) and partial least square (PLS)-discriminant analysis (DA). Time- and dose-dependent separation of HgCl{sub 2}-treated animals from controls was observed by PCA of {sup 1}H NMR spectral data. In HgCl{sub 2}-treated rats, the concentrations of endogenous urinary metabolites of glucose, acetate, alanine, lactate, succinate, and ethanol were significantly increased, whereas the concentrations of 2-oxoglutarate, allantoin, citrate, formate, taurine, and hippurate were significantly decreased. These endogenous metabolites were selected as putative biomarkers for HgCl{sub 2}-induced nephrotoxicity. A dose response was observed in concentrations of lactate, acetate, succinate, and ethanol, where severe disruption of the concentrations of 2-oxoglutarate, citrate, formate, glucose, and taurine was observed at the higher dose (0.75 mg/kg) of HgCl{sub 2}. Correlation of urinary {sup 1}H NMR PLS-DA data with renal histopathologic changes suggests that {sup 1}H NMR urinalysis can be used to predict or screen for HgCl{sub 2}-induced nephrotoxicity{sub .}

60 APPLIED LIFE SCIENCES↗