Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC SHIELDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Preliminary calculation of solar cosmic ray dose to the female breast in space mission

No regulatory dose limits are specifically assigned for the radiation exposure of female breasts during manned space flight. However, the relatively high radiosensitivity of the glandular tissue of the breasts and its potential exposure to solar flare protons on short- and long-term missions mandate a priori estimation of the associated risks. A model for estimating exposure within the breast is developed for use in future NASA missions. The female breast and torso geometry is represented by a simple interim model. A recently developed proton dose-buildup procedure is used for estimating doses. The model considers geomagnetic shielding, magnetic-storm conditions, spacecraft shielding, and body self-shielding. Inputs to the model include proton energy spectra, spacecraft orbital parameters, STS orbiter-shielding distribution at a given position, and a single parameter allowing for variation in breast size.

Shavers, Mark↗

MAARSS: Magnet Architectures and Active Radiation Shielding Study

Protecting humans from space radiation is a major hurdle for human exploration of the solar system and beyond. Like on Earth, large magnetic fields surrounding a spaceship would deflect charged particles away from the habitat region and reduce the radiation dose to acceptable limits. The objective of this study is to determine the feasibility of current state of the art (SOA) high temperature superconducting (HTS) magnets as a means to protect crew from space radiation exposure on long duration missions beyond Low Earth Orbit (LEO). The study will look at architecture concepts to deflect high energy Galactic Cosmic Radiation (GCR) and Solar Proton Events (SPEs). Mass, power, and shielding efficiency will be considered and compared with current passive shielding capabilities. This report will walk the reader through several designs considered over the one year study and discuss the multiple parameters that should be evaluated for magnetic shielding. The study team eventually down-selects to a scalable light weight solenoid architecture that is launchable and then deployable using magnetic pressure to expand large diameter coils. Benefitting from the low temperature and high vacuum environment of deep space, existing high-temperature superconductors make such radiation shields realistic, near-term technical developments.

Westover, Shayne C.↗

Magnet Architectures and Active Radiation Shielding Study - SR2S Workshop

Analyze new coil configurations with maturing superconductor technology -Develop vehicle-level concept solutions and identify engineering challenges and risks -Shielding performance analysis Recent advances in superconducting magnet technology and manufacturing have opened the door for re-evaluating active shielding solutions as an alternative to mass prohibitive passive shielding.Publications on static magnetic field environments and its bio-effects were reviewed. Short-term exposure information is available suggesting long term exposure may be okay. Further research likely needed. center dotMagnetic field safety requirements exist for controlled work environments. The following effects have been noted with little noted adverse effects -Magnetohydrodynamic (MHD) effects on ionized fluids (e.g. blood) creating an aortic voltage change -MHD interaction elevates blood pressure (BP) center dot5 Tesla equates to 5% BP elevation -Prosthetic devises and pacemakers are an issue (access limit of 5 gauss).

Westover, Shane↗

Passive Superconducting Shielding: Experimental Results and Computer Models

Passive superconducting shielding for magnetic refrigerators has advantages over active shielding and passive ferromagnetic shielding in that it is lightweight and easy to construct. However, it is not as easy to model and does not fail gracefully. Failure of a passive superconducting shield may lead to persistent flwc and persistent currents. Unfortunately, modeling software for superconducting materials is not as easily available as is software for simple coils or for ferromagnetic materials. This paper will discuss ways of using available software to model passive superconducting shielding.

Warner, Brent↗

Passive Superconducting Shielding: Experimental Results and Computer Models

Passive superconducting shielding for magnetic refrigerators has advantages over active shielding and passive ferromagnetic shielding in that it is lightweight and easy to construct. However, it is not as easy to model and does not fail gracefully. Failure of a passive superconducting shield may lead to persistent flux and persistent currents. Unfortunately, modeling software for superconducting materials is not as easily available as is software for simple coils or for ferromagnetic materials. This paper will discuss ways of using available software to model passive superconducting shielding.

Warner, B. A.↗

Current-Produced Magnetic Field Effects on Current Collection

Current collection by an infinitely long, conducting cylinder in a magnetized plasma, taking into account the magnetic field of the collected current, is discussed. A region of closed magnetic surfaces disconnects the cylinder from infinity. Due to this, the collected current depends on the ratio between this region and the plasma sheath region and, under some conditions, current reduction arises. The current collection along a realistic "bare wire" space tether is considered. A number of factors are taken into account, including the resistance of the wire and shielding resulting from the current-induced magnetic field produced by current flow in the tether. The plasma density, tether length and radius, the geomagnetic field strength and angle to the orbital velocity vector were all used as parameters in the study. It is shown that magnetic shielding for certain tether system configurations, when combined with particular values of the governing parameters, significantly reduces the collected current. Specifically, it is shown that an electrodynamic tether in the "thruster" mode suffers greater reduction from magnetic shielding than a tether with the same characteristics deployed in the "generator" mode. We find that, for both modes, current-induced magnetic shielding becomes more significant as plasma density and wire radius increase. The same is true for the dependence on the angle of the geomagnetic field to the orbital velocity vector and the motion-induced electric field for the generator mode For the thruster mode, the effect is larger for smaller angles. In both operating modes, the shielding is more important for smaller angles between the tether and magnetic field. In addition to the above dependencies, the effect for the thruster mode essentially depends on the tether length. In general, any parametric change that increases tether current, relative to the strength of the electric field between the tether and the ambient plasma, will increase the shielding effect (thereby reducing overall tether current compared to the case without considering these effects). The effect of the induced magnetic shielding can be significant in some cases.

Khazanov, George V.↗

Proceedings of the Magnetics Workshop

Conference on measurement and reduction of spacecraft magnetic fields - materials and design criteria - magnetic decontamination of components - testing facilities and human tests

CONFERENCE↗

Neutronics analysis of spin-polarized fuel in spherical tokamaks

The effect of spin-polarized deuterium–tritium fuel on the blanket, magnets, and surrounding structures is analyzed for a spherical tokamak fusion power plant. The focus of this paper is the neutron flux distribution in the fusion device and the corresponding engineering considerations, such as tritium breeding ratio (TBR) and magnet fluence. Significant benefits were found for anti-aligned polarization: a 2.7% increase in the total TBR (which could increase significantly with further optimization) and an approximately 68% increase in the magnet lifetime. If the inboard breeding blanket can be replaced with extra shielding and magnets, then it could significantly increase fusion power with no loss of magnet lifetime. This would be accomplished by increasing the toroidal field strength.

fusion↗

Study - Radiation Shielding Effectiveness of the Prototyped High Temperature Superconductivity (HTS) 'Artificial' Magnetosphere for Deep Space Missions

The high temperature superconductor (HTS) is being used to develop the magnets for the Variable Specific Impulse Magneto-plasma Rocket (VASIMR ) propulsion system and may provide lightweight magnetic radiation shielding to protect spacecraft crews from radiation caused by GCR and SPEs on missions to Mars. A study is being planned to assess the radiation shielding effectiveness of the artificial magnetosphere produced by the HTS magnet. VASIMR is an advanced technology propulsion engine which is being touted as enabling one way transit to Mars in 90 days or less. This is extremely important to NASA. This technology would enable a significant reduction in the number of days in transit to and from Mars and significantly reduce the astronauts exposure to a major threat - high energy particles from solar storms and GCR during long term deep space missions. This paper summarizes the plans for the study and the subsequent testing of the VASIMR technology onboard the ISS slated for 2013.

Denkins, Pamela↗

Molecular NMR shieldings, J -couplings, and magnetizabilities from numeric atom-centered orbital based density-functional calculations

This paper reports and benchmarks a new implementation of nuclear magnetic resonance shieldings, magnetizabilities, and J-couplings for molecules within semilocal density functional theory, based on numeric atom-centered orbital (NAO) basis sets. NAO basis sets are attractive for the calculation of these nuclear magnetic resonance (NMR) parameters because NAOs provide accurate atomic orbital representations especially near the nucleus, enabling high-quality results at modest computational cost. Moreover, NAOs are readily adaptable for linear scaling methods, enabling efficient calculations of large systems. Here, the paper has five main parts: (1) It reviews the formalism of density functional calculations of NMR parameters in one comprehensive text to make the mathematical background available in a self-contained way. (2) The paper quantifies the attainable precision of NAO basis sets for shieldings in comparison to specialized Gaussian basis sets, showing similar performance for similar basis set size. (3) The paper quantifies the precision of calculated magnetizabilities, where the NAO basis sets appear to outperform several established Gaussian basis sets of similar size. (4) The paper quantifies the precision of computed J-couplings, for which a group of customized NAO basis sets achieves precision of ~Hz for smaller basis set sizes than some established Gaussian basis sets. (5) The paper demonstrates that the implementation is applicable to systems beyond 1000 atoms in size.

74 ATOMIC AND MOLECULAR PHYSICS↗

Relation of MAGSAT and Gravity Anomalies to the Main Tectonic Provinces of South America

Magnetic anomalies of the South American continent are generally more positive and variable than the oceanic anomalies. There is better correlation between the magnetic anomalies and the major tectonic elements of the continents than between the anomalies and the main tectonic elements of the adjacent oceanic areas. Oceanic areas generally show no direct correlation to the magnetic anomalies. Precambrian continental shields are mainly more magnetic than continental basins and orogenic belts. Shields differ markedly from major aulacogens which are generally characterized by negative magnetic anomalies and positive gravity anomalies. The Andean orogenic belt shows rather poor correlation with the magnetic anomalies. The magnetic data exhibit instead prominent east-west trends, which although consistent with some tectonic features, may be related to processing noise derived from data reduction procedures to correct for external magnetic field effects. The pattern over the Andes is sufficiently distinct from the generally north trending magnetic anomalies occurring in the adjacent Pacific Ocean to separate effectively the leading edge of the South American Plate from the Nazea Plate. Eastern South America is characterized by magnetic anomalies which commonly extend across the continental margin into the Atlantic Ocean.

Yuan, D. W.↗

Characteristics of Ferromagnetic Flux Focusing Lens in the Development of Surface/Subsurface Flaw Detector

Electromagnetic NDE techniques have in the past steered away from the use of ferromagnetic materials. Although their high permeabilities lead to increased field levels, the properties of ferrous elements in the presence of alternating magnetic fields are difficult to determine. In addition, their use leads to losses which can be minimized through the use of low conductivity ferrites. In fact, the eddy current probes which do incorporate ferromagnetic materials have focused on these losses and the shielding which can be obtained by surrounding a probe with a high permeability, conducting material. Eddy current probes enclosed in conducting and magnetic shields have been used to prevent the generated fields from interacting with materials in the vicinity of the probe, such as when testing near material boundaries. A recent invention has used ferromagnetic shielding to magnetically separate individual concentric eddy current probes in order to eliminate cross-talk between the probes so that simultaneous detection of different types of flaws at different depths can be achieved. In contrast to the previous uses of ferromagnetic materials purely as magnetic shields, an electromagnetic flaw detector recently developed at NASA Langley Research Center takes advantage of the flux focusing properties of a ferromagnetic mild steel in order to produce a simple, effective device for the non-destructive evaluation of conducting materials. The Flux Focusing Eddy Current Probe has been shown to accurately measure material thickness and fatigue damage. The straight forward flaw response of the probe makes the device ideal for rapid inspection of large structures, and has lead to its incorporation in a computer controlled search routine to locate fatigue crack tips and monitor experimental fatigue crack growth experiments.

Wincheski, Buzz↗

A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dV cm /dt ~ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the B p coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

QSHS: an axion dark matter resonant search apparatus

We describe a resonant cavity search apparatus for axion dark matter constructed by the quantum sensors for the hidden sector collaboration. The apparatus is configured to search for QCD axion dark matter, though also has the capability to detect axion-like particles, dark photons, and some other forms of wave-like dark matter. Initially, a tuneable cylindrical oxygen-free copper cavity is read out using a low noise microwave amplifier feeding a heterodyne receiver. The cavity is housed in a dilution refrigerator (DF) and threaded by a solenoidal magnetic field, nominally 8 T. The apparatus also houses a magnetic field shield for housing superconducting electronics, and several other fixed-frequency resonators for use in testing and commissioning various prototype quantum electronic devices sensitive at a range of axion masses in the range 2.0–40 μ eV c -2 . The apparatus as currently configured is intended as a test stand for electronics over the relatively wide frequency band attainable with TM 010 the cavity mode used for axion searches. We present performance data for the resonator, DF, and magnet, and plans for the first science run.

Physics - Physics of elementary particles and fiel↗

Single Pixel Characterization of X-Ray TES Microcalorimeter Under AC Bias at MHz Frequencies

In this paper we present the progress made at SRON in the read-out of GSFC x-ray transition-edge sensor (TES) micro-calorimeters in the frequency domain. The experiments reported so far, whose aim was to demonstrate an energy resolution of 2eV at 6 keV with a TES acting as a modulator, were carried out at frequencies below 700 kHz using a standard flux locked loop (FLL) SQUID read-out scheme. The TES read-out suffered from the use of sub-optimal circuit components, large parasitic inductances, low quality factor resonators and poor magnetic field shielding. We have developed a novel experimental set-up, which allows us to test several read-out schemes in a single cryogenic run. In this set-up, the TES pixels are coupled via superconducting transformers to 18 high-Q lithographic LC filters with resonant frequencies ranging between 2 and 5 MHz. The signal is amplified by a two-stage SQUID current sensor and baseband feedback is used to overcome the limited SQUID dynamic range. We study the single pixel performance as a function of TES bias frequency, voltage and perpendicular magnetic field.

Gottardi, L.↗