Search NASA⌕ Search

SEARCH · Search NASA

Results for “MIRROR RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Fiber optic sensing system

A fiber optic interferometer utilizes a low coherence light emitting diode (LED) laser as a light source which is filtered and driven at two RF frequencies, high and low, that are specific to the initial length of the resonator chamber. A displacement of a reflecting mirror changes the length traveled by the nonreferencing signal. The low frequency light undergoes destructive interference which reduces the average intensity of the wave while the high frequency light undergoes constructive interference which increases the average intensity of the wave. The ratio of these two intensity measurements is proportional to the displacement incurred.

Adamovsky, Grigory↗

Elastic Electron Scattering From Mirror Nuclei 3He and 3H

The primary aim of my work is the extraction of the elastic cross-sections from data collected in Jefferson Lab Hall A experiment E12-11-112 which measured inclusive elastic scattering from the mirror nuclei 3He and 3H at low momentum transfer Q2 ? 0.1 GeV2. The obtained 3H cross-section is 0.630 ± 0.027 ?barn/sr with fractional uncertainty 4.35% and 3He cross- section is 1.274 ± 0.055 ?barn/sr with fractional uncertainty 4.29% . I determined the ratio of the 3He and 3H cross-sections since it cancels many of the systematic uncertainties that enter into the absolute cross-section extraction, and it reduced the fractional uncertainty to 1.85%.

Kurbany, Leiqaa↗

Stopped, Bunched Beams for the TwinSol Facility

Tests of the unitarity of the Cabbibo-Kobayashi-Masakawa (CKM) matrix offer an important avenue for constraining the Standard Model of the electroweak interaction. Several methods are currently used to determine V-ud, the largest element in the top-row normalization test. One such method is through the study of superallowed T =1/2 mixed mirror transitions, which offers a complementary method to the current most-precise value that is determined from superallowed pure Fermi 0(+) 0(+) transitions. The precision currently achievable by this method is currently limited by the very low number of transitions for which the Fermi-to-Gamow-Teller mixing ratio has been measured. St. Benedict, the Superallowed Transition Beta-Neutrino Decay-Ion-Coincidence Trap, is currently under development at the University of Notre Dame's Nuclear Science Laboratory, and intends to determine for a range of new isotopes through measurements of the -neutrino asymmetry parameter a using a linear Paul trap. In order to trap these ions, the fast, continuous secondary beam separated by the TwinSol twin solenoid separator must be thermalized and bunched. The system through which this will be done will feature a large-volume gas cell in which the ions will be thermalized, a double-RF-funnel-based ion guide system for the extraction of the ions, and a radiofrequency quadrupole (RFQ) to provide cooled ion bunches for capture in the Paul trap.

beam cooling↗

Anisotropy of effective electron masses in highly doped nonpolar GaN

The anisotropic effective electron masses in wurtzite GaN are determined by generalized infrared spectroscopic ellipsometry. Nonpolar (112{sup ¯}0) oriented thin films allow accessing both effective masses, m{sub ⊥}{sup *} and m{sub ∥}{sup *}, by determining the screened plasma frequencies. A n-type doping range up to 1.7 × 10{sup 20} cm{sup −3} is investigated. The effective mass ratio m{sub ⊥}{sup *}/m{sub ∥}{sup *} is obtained with highest accuracy and is found to be 1.11 independent on electron concentration up to 1.2 × 10{sup 20} cm{sup −3}. For higher electron concentrations, the conduction band non-parabolicity is mirrored in changes. Absolute values for effective electron masses depend on additional input of carrier concentrations determined by Hall effect measurements. We obtain m{sub ⊥}{sup *}=(0.239±0.004)m{sub 0} and m{sub ∥}{sup *}=(0.216±0.003)m{sub 0} for the parabolic range of the GaN conduction band. Our data are indication of a parabolic GaN conduction band up to an energy of approximately 400 meV above the conduction band minimum.

36 MATERIALS SCIENCE↗

USING THE X-RAY MORPHOLOGY OF YOUNG SUPERNOVA REMNANTS TO CONSTRAIN EXPLOSION TYPE, EJECTA DISTRIBUTION, AND CHEMICAL MIXING

Supernova remnants (SNRs) are a complex class of sources, and their heterogeneous nature has hindered the characterization of their general observational properties. To overcome this challenge, in this paper, we use statistical tools to analyze the Chandra X-ray images of Galactic and Large Magellanic Cloud SNRs. We apply two techniques, a power-ratio method (a multipole expansion) and wavelet-transform analysis, to measure the global and local morphological properties of the X-ray line and thermal emission in 24 SNRs. We find that Type Ia SNRs have statistically more spherical and mirror-symmetric thermal X-ray emission than core-collapse (CC) SNRs. The ability to type SNRs based on thermal emission morphology alone enables, for the first time, the typing of SNRs with weak X-ray lines and those with low-resolution spectra. Based on our analyses, we identify one source (SNR G344.7-0.1) as originating from a CC explosion that was of unknown origin previously; we also confirm the tentative Type Ia classifications of G337.2-0.7 and G272.2-3.2. Although the global morphology is indicative of the explosion type, the relative morphology of the X-ray line emission within SNRs is not: all sources in our sample have well-mixed ejecta, irrespective of stellar origin. In particular, we find that 90% of the bright metal-line-emitting substructures are spatially coincident and have similar scales, even if the metals arise from different burning processes. Moreover, the overall X-ray line morphologies within each SNR are the same, with <6% differences. These findings reinforce observationally that hydrodynamical instabilities can efficiently mix ejecta in Type Ia and CC SNRs. The only exception is W49B, which can be attributed to its jet-driven/bipolar explosive origin. Based on comparative analyses across our sample, we describe several observational constraints that can be used to test hydrodynamical models of SNR evolution; notably, the filling factor of X-ray emission decreases with SNR age.

79 ASTRONOMY AND ASTROPHYSICS↗

β -decay study of the T z = - 2 proton-rich nucleus Mg 20

We report the β decay of the drip-line nucleus 20 Mg gives important information on key astrophysical resonances in 20 Na, which are relevant to the onset of the rapid proton capture process. A detailed β-decay spectroscopic study of 20 Mg was performed by a continuous-implantation method. A detection system was specially developed for charged-particle decay studies, giving improved spectroscopic information including the delayed proton energies, the half-life of 20 Mg, the excitation energies, the branching ratios, and the log ft values for the states in 20 Na populated in the β decay of 20 Mg. A new proton branch was observed and the corresponding excited state in 20 Na was proposed. The large isospin asymmetry for the mirror decays of 20 Mg and 20 O was also well reproduced. Lastly, to resolve the long-standing problem about the astrophysically interesting 2645 keV resonance in 20 Na convincingly, a higher-statistics measurement may still be needed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The parathyroid hormone circadian rhythm is truly endogenous--a general clinical research center study

While circulating levels of PTH follow a diurnal pattern, it has been unclear whether these changes are truly endogenous or are dictated by external factors that themselves follow a diurnal pattern, such as sleep-wake cycles, light-dark cycles, meals, or posture. We evaluated the diurnal rhythm of PTH in 11 normal healthy male volunteers in our Intensive Physiologic Monitoring Unit. The first 36 h spent under baseline conditions were followed by 28-40 h of constant routine conditions (CR; enforced wakefulness in the strict semirecumbent position, with the consumption of hourly snacks). During baseline conditions, PTH levels followed a bimodal diurnal rhythm with an average amplitude of 4.2 pg/mL. A primary peak (t1max) occurred at 0314 h, and the secondary peak (t2max) occurred at 1726 h, whereas the primary and secondary nadirs (t1min and t2min) took place, on the average, at 1041 and 2103 h, respectively. This rhythm was preserved under CR conditions, albeit with different characteristics, thus confirming its endogenous nature. The serum ionized calcium (Cai) demonstrated a rhythm in 3 of the 5 subjects studied that varied widely between individuals and did not have any apparent relation to PTH. Urinary calcium/creatinine (UCa/Cr), phosphate/Cr (UPO4/Cr), and sodium/Cr (UNa/Cr) ratios all followed a diurnal rhythm during the baseline day. These rhythms persisted during the CR, although with different characteristics for the first two parameters, whereas that of UNa/Cr was unchanged. In general, the temporal pattern for the UCa/Cr curve was a mirror image of the PTH curve, whereas the UPO4/Cr pattern moved in parallel with the PTH curve. In conclusion, PTH levels exhibit a diurnal rhythm that persists during a CR, thereby confirming that a large component of this rhythm is an endogenous circadian rhythm. The clinical relevance of this rhythm is reflected in the associated rhythms of biological markers of PTH effect at the kidney, namely UCa/Cr and UPO4/Cr.

NASA Discipline Musculoskeletal↗

Quantum vacuum processes in the extremely intense light of relativistic plasma mirror sources

Abstract The advent of petawatt-class laser systems allows generating electromagnetic fields of unprecedented strength in a controlled environment, driving increasingly more efforts to probe yet unobserved processes through their interaction with the quantum vacuum. Still, the lowest intensity scale governing these effects lies orders of magnitude beyond foreseen capabilities, so that such endeavor is expected to remain extremely challenging. In recent years, however, plasma mirrors have emerged as a promising bridge across this gap, by enabling the conversion of intense infrared laser pulses into coherently focused Doppler harmonic beams lying in the X-UV range. In this work, we present predictions on the quantum vacuum signatures produced when such beams are focused to intensities between 10 24 and 10 28 W cm −2 , specifically photon–photon scattering and electron–positron pair creation. These signatures are computed via the stimulated vacuum formalism, combined with a model of perfectly focused beam built from PIC-generated harmonics spectra, and implemented on state-of-the-art massively parallel numerical tools. In view of identifying experimentally favorable configurations, we also consider the coupling of the focused harmonic beam with an auxiliary optical beam, and provide comparison with other established schemes. Our results show that a single coherently focused harmonic beam can produce as much scattered photons as two infrared pulses in head-on collision, and confirm that the coupling of the harmonic beam to an auxiliary beam gives rise to significant levels of inelastic scattering, and hence holds the potential to strongly improve the attainable signal to noise ratios in experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrade of the Resonance Ionization Mass Spectrometer for Precise Identification of Failed Fuel in a Fast Reactor

Isotopic analysis of krypton (Kr) and xenon (Xe) by resonance ionization mass spectrometry (RIMS) is an effective tool for identification of failed fuel in fast reactors to achieve their safety operation and high plant availability. Reliability of the failed fuel detection and location (FFDL) system depends on the precise determination of {sup 78}Kr/{sup 80}Kr, {sup 82}Kr/{sup 80}Kr and {sup 126}Xe/{sup 129}Xe isotopic ratios, which is mainly hampered by statistical errors for detection of the corresponding isotopes except {sup 82}Kr generated in large amounts during operation of fast reactors. In this paper, we report on improvements of the laser optical system of our spectrometer to increase the resonance ionization efficiency of Kr and Xe atoms, focusing on (i) utilization of the uniform YAG laser beam to improve the wavelength conversion efficiency of sum frequency generation and (ii) reflection of the ultraviolet light by a concave mirror to increase the photon density. The results indicate that our upgraded resonance ionization mass spectrometer has enough performance for isotopic analysis of Kr and Xe required in the Monju FFDL system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A DISTANT MIRROR: SOLAR OSCILLATIONS OBSERVED ON NEPTUNE BY THE KEPLER K 2 MISSION

Starting in 2014 December, Kepler K 2 observed Neptune continuously for 49 days at a 1 minute cadence. The goals consisted of studying its atmospheric dynamics, detecting its global acoustic oscillations, and those of the Sun, which we report on here. We present the first indirect detection of solar oscillations in intensity measurements. Beyond the remarkable technical performance, it indicates how Kepler would see a star like the Sun. The result from the global asteroseismic approach, which consists of measuring the oscillation frequency at maximum amplitude ν {sub max} and the mean frequency separation between mode overtones Δ ν , is surprising as the ν {sub max} measured from Neptune photometry is larger than the accepted value. Compared to the usual reference ν {sub max,⊙} = 3100 μ Hz, the asteroseismic scaling relations therefore make the solar mass and radius appear larger by 13.8 ± 5.8% and 4.3 ± 1.9%, respectively. The higher ν {sub max} is caused by a combination of the value of ν {sub max,⊙}, being larger at the time of observations than the usual reference from SOHO /VIRGO/SPM data (3160 ± 10 μ Hz), and the noise level of the K 2 time series, being 10 times larger than VIRGO’s. The peak-bagging method provides more consistent results: despite a low signal-to-noise ratio (S/N), we model 10 overtones for degrees ℓ = 0, 1, 2. We compare the K 2 data with simultaneous SOHO /VIRGO/SPM photometry and BiSON velocity measurements. The individual frequencies, widths, and amplitudes mostly match those from VIRGO and BiSON within 1 σ, except for the few peaks with the lowest S/N.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of a new DIII-D Doppler backscattering system for higher wavenumber measurement and signal enhancement

The high density fluctuation poloidal wavenumber, k θ (k θ > 8 cm –1 , k θ ρ s > 5, ρs is the ion gyro radius using the ion sound velocity), measurement capability of a new Doppler backscattering (DBS) system at the DIII-D tokamak has been experimentally evaluated. In DBS, wavenumber (k) matching becomes more important at higher wavenumbers, owing to the exponential dependence of the measured signal loss factor on wave vector mismatch. Wave vector matching allows for the Bragg scattering condition to be satisfied, which minimizes the signal loss at higher k’s. In the previous DBS system, without toroidal wave vector matching, the measured DBS signal-to-noise ratio at higher k θ (>8 cm –1 ) is substantially reduced, making it difficult to measure higher k θ turbulence. The new DBS system has been optimized to access higher wavenumber, k θ ≤ 20 cm –1 , density turbulence measurement. The optimization hardware addresses fluctuation wave vector matching using toroidal steering of the launch mirror to produce a backscattered signal with improved intensity. The probe’s sensitivity to high-k density fluctuations has been increased by approximately an order of magnitude compared to the old system that has been in use at DIII-D. Note that typical measurement locations are above or below the tokamak midplane on the low field side with normalized radial ranges of 0.5–1.0. As a result, the new DBS probe system with the toroidal matching of fluctuation wave vectors is thought to be critical to understanding high-k turbulent transport in fusion-relevant research at DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Food web dynamics drive variation in Smallmouth Bass Micropterus dolomieu mercury contamination in protected Southern Appalachian streams

Mercury is a global pollutant that threatens otherwise protected aquatic ecosystems. Mercury food web dynamics are not well understood in streams with no point sources of contamination but have the potential to concentrate this dangerous pollutant in upper trophic level consumers. A 2016 study revealed that mercury concentrations of Smallmouth Bass Micropterus dolomieu varied between three streams in Great Smoky Mountains National Park (GSMNP), Tennessee, USA. We tested the hypothesis that food web interactions drive spatial variation in mercury concentrations of the apex predator of protected stream ecosystems. We measured carbon and nitrogen stable isotope ratios, and mercury concentrations of eight food web components of GSMNP streams including basal resources, intermediate consumers, and Smallmouth Bass, the apex predator. Mean THg concentrations of basal resources did not differ between streams, but the spatial pattern of concentrations of intermediate consumers mirrored Smallmouth Bass. Relationships between organismal contaminant concentrations and trophic level were positive in all three streams, indicating biomagnification is occurring in the protected streams of GSMNP. Furthermore, our findings indicate that mercury dynamics in intermediate trophic levels, rather than differences in basal resource concentrations, may drive differences in mercury contamination of apex predators of the protected stream ecosystems of GSMNP.

Bioaccumulation↗

Experimental demonstration of a displacement noise free interferometry scheme for gravitational wave detectors showing displacement noise reduction at low frequencies

This paper reports an experimental demonstration of partial displacement noise free laser interferometry in the gravitational wave detection band. The used detuned Fabry-Perot cavity allows the isolation of the mimicked gravitational wave signal from the displacement noise on the cavities input mirror. By properly combining the reflected and transmitted signals from the cavity a reduction of the displacement noise was achieved. Our results represent the first experimental demonstration of this recently proposed displacement noise free laser interferometry scheme. Overall, we show that the rejection ratio of the displacement noise to the gravitational wave signal was improved in the frequency range of 10 Hz to 10 kHz with a typical factor of {approx}60.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Stability of a 4 Meter Primary Reflector for the Scanning Microwave Limb Sounder

We describe the fabrication and thermal-stability analysis and test of a composite demonstration model of the Scanning Microwave Limb Sounder (SMLS) primary reflector, having full 4m height and 1/3 the width planned for flight. SMLS is a space-borne heterodyne radiometer which will measure pressure, temperature and atmospheric constituents from thermal emission between 180 and 660 GHz. Current MLS instruments in low Earth orbit scan pencil-beam antennas (sized to resolve about one scale height) vertically over the atmospheric limb. SMLS, planned for the Global Atmospheric Composition Mission of the NRC Decadal Survey, adds azimuthal scanning for better horizontal and temporal resolution and coverage than typical orbit spacing provides. SMLS combines the wide scan range of the parabolic torus with unblocked offset Cassegrain optics. The resulting system is diffraction-limited in the vertical plane but highly astigmatic in the horizontal, having a beam aspect ratio [tilde operator]1:20. Symmetry about the nadir axis ensures that beam shape is nearly invariant over +/-65(white bullet) azimuth. The a feeds a low-noise SIS receiver whose FOV is swept over the reflector system by a small scanning mirror. Using finiteelement models of antenna reflectors and structure, we evaluate thermal deformations and the resulting optical performance for 4 orbital environments and isothermal soak. We compare deformations with photogrammetric measurements made during wide-range (ambient+[-97,+75](white bullet) C) thermal soak tests of the primary in a chamber. This range exceeds predicted orbital soak ranges by large factors, implying in-orbit thermal stability of 0.21(mu)m rms/(white bullet)C, which meets SMLS requirements.

Thermal stability tests↗

Differential flow correlations in relativistic heavy-ion collisions

A systematic analysis of correlations between different orders of p T -differential flow is presented here, including mode coupling effects in flow vectors, correlations between flow angles (a.k.a. event-plane correlations), and correlations between ow magnitudes, all of which were previously studied with integrated flows. Furthermore, we find that the mode coupling effects among differential flows largely mirror those among the corresponding integrated flows, except at small transverse momenta where mode coupling contributions are small. For the fourth- and fifth-order flow vectors V 4 and V 5 we argue that the event plane correlations can be understood as the ratio between the mode coupling contributions to these flows and the flow magnitudes. We also find that for V 4 and V 5 the linear response contribution scales linearly with the corresponding cumulant-defined eccentricities but not with the standard eccentricities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A microprocessor-based position control system for a telescope secondary mirror

The pointing requirements for the Shuttle IR Telescope Facility (SIRTF), which consists of an 0.85-m cryogenically cooled IR telescope, call for an image stability of 0.25 arcsec. Attention is presently given to a microprocessor-based position control system developed for the control of the SIRTF secondary mirror, employing a special control law (to minimize energy dissipation), a precision capacitive position sensor, and a specially designed power amplifier/actuator combination. The microprocessor generates the command angular position and rate waveforms in order to maintain a 90 percent dwell time/10 percent transition time ratio independently of chop frequency or amplitude. Performance and test results of a prototype system designed for use with a demonstration model of the SIRTF focal plane fine guidance sensor are presented.

Lorell, K. R.↗

Compressional ULF waves in the outer magnetosphere. 2: A case study of Pc 5 type wave activity

In previously published work (Zhu and Kivelson, 1991) the spatial distribution of compressional magnetic pulsations of period 2 - 20 min in the outer magnetosphere was described. In this companion paper, we study some specific compressional events within our data set, seeking to determine the structure of the waves and identifying the wave generation mechanism. We use both the magnetic field and three-dimensional plasma data observed by the International Sun-Earth Explorer (ISEE) 1 and/or 2 spacecraft to characterize eight compressional ultra low frequency (ULF) wave events with frequencies below 8 mHz in the outer magnetosphere. High time resolution plasma data for the event of July 24, 1978, made possible a detailed analysis of the waves. Wave properties specific to the event of July 24, 1978, can be summarized as follows: (1) Partial plasma pressures in the different energy ranges responded to the magnetic field pressure differently. In the low-energy range they oscillated in phase with the magnetic pressure, while oscillations in higher-energy ranges were out-of-phase; (2) Perpendicular wavelengths for the event were determined to be 60,000 and 30,000 km in the radial and azimuthal directions, respectively. Wave properties common to all events can be summarized as follows: (1) Compressional Pc 5 wave activity is correlated with Beta, the ratio of the plasma pressure to the magnetic pressure; the absolute magnitude of the plasma pressure plays a minor role for the wave activity; (2) The magnetic equator is a node of the compressional perturbation of the magnetic field; (3) The criterion for the mirror mode instability is often satisfied near the equator in the outer magnetosphere when the compressional waves are present. We believe these waves are generated by internal magnetohydrodynamic (MHD) instabilities.

Zhu, Xiaoming↗

Re-measuring the nucleon's F2(n) / F2(p) and d/u

The reliability of the existing extraction of the nucleon structure function and quark distribution ratios F 2 n /F 2 p and d/u from measurements of deep inelastic electron scattering off the proton and deuteron is discussed. Jefferson Lab measurements using semi-inclusive electron-deuteron scattering and deep inelastic electron scattering off the 3He and 3H mirror nuclei, expected to provide data free of theoretical uncertainties, are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗