Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mars Science (MSL) Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Comparison of Statistical Estimation Techniques for Mars Entry, Descent, and Landing Reconstruction from MEDLI-like Data Sources

Flight data from an entry, descent, and landing (EDL) sequence can be used to reconstruct the vehicle's trajectory, aerodynamic coefficients and the atmospheric profile experienced by the vehicle. Past Mars missions have contained instruments that do not provide direct measurement of the freestream atmospheric conditions. Thus, the uncertainties in the atmospheric reconstruction and the aerodynamic database knowledge could not be separated. The upcoming Mars Science Laboratory (MSL) will take measurements of the pressure distribution on the aeroshell forebody during entry and will allow freestream atmospheric conditions to be partially observable. This data provides a mean to separate atmospheric and aerodynamic uncertainties and is part of the MSL EDL Instrumentation (MEDLI) project. Methods to estimate the flight performance statistically using on-board measurements are demonstrated here through the use of simulated Mars data. Different statistical estimators are used to demonstrate which estimator best quantifies the uncertainties in the flight parameters. The techniques demonstrated herein are planned for application to the MSL flight dataset after the spacecraft lands on Mars in August 2012.

Dutta, Soumyo↗

The Ice-Covered Lakes Hypothesis in Gale Crater: Implications for the Early Hesperian Climate

Recent geological discoveries from the Mars Science Laboratory (MSL), including stream and lake sedimentary deposits, provide evidence that Gale crater may have intermittently hosted a fluviol-acustine environment during the Hesperian, with individual lakes lasting for a period of tens to hundreds of thousands of years. Estimates of the CO2 content of the atmosphere at the time the Gale sediments formed are far less than needed by any climate model to warm early Mars, given the low solar energy input available at Mars 3.5 Gya. We have therefore explored the possibility that the lakes in Gale during the Hesperian were perennially covered with ice using the Antarctic lakes as analogs.

CO2 content of the atmosphere↗

Testing Destruction of Clay Minerals By Silica-Poor Brines in Gale Crater, Mars Using Laboratory and Field Experiments

The Mars Science Laboratory (MSL) Curiosity rover landed in Gale crater to investigate the cause for mineralogical changes seen from orbit, including the clay-sulfate mineral transition observed on its central mound, Aeolis Mons. The lower strata show spectral signatures of clay minerals, hematite, and hydrated Mg sulfates, and the upper strata are dominated by hydrated Mg sulfate signatures. This significant transition has been observed in other locations on Mars, and therefore processes related to the clay mineral-sulfate transition are likely important broadly across Mars. The bulk mineralogy of ~3.7 Ga sedimentary rocks in Gale crater is a product of variations in sediment sources and depositional processes, with overprinting by episodes of early and late diagenetic alteration. Sedimentary analyses of the smectite clay minerals observed in the Glen Torridon (GT) region of Mount Sharp suggest formation in a lacustrine aqueous environment. Examination of the Vera Rubin ridge (VRR) strata indicate that it was formed at the same time as GT and later altered by extensive diagenesis. Recent work suggests that the observed mineral transition from smectites and talc-serpentinites in GT to iron oxides and oxyhydroxides and VRR may have resulted from extensive diagenetic alteration by density driven, silica-poor brines sourced from the overlying sulfur-bearing unit on Mount Sharp. This process of alteration by silica-poor brines is observed in limited locations on Earth. We are therefore working to demonstrate the impacts of silica poor brines on clay mineral alteration in laboratory column and terrestrial analog burial experiments. Column experiments allow the investigation of dissolution and precipitation under conditions that represent a closer analog to natural environments, while burial experiments allow examination of weathering reactions of a known starting material after a specific period of time in a natural field environment. Both methods are valuable for interpreting the water-rock interactions between clay minerals and brines. In preparation for these longer-term column and burial experiments, we are performing preliminary batch dissolution experiments on materials relevant to Glen Torridon: nontronite and serpentinite. We are using magnesium sulfate brine solutions relevant to those proposed on Mars. The results of this study can provide constraints on the characteristics of the diagenetic fluids that formed the altered minerals in Gale crater. They can also provide insights into the role of brine density-driven diagenesis in past aqueous environments on Mars, which have been proposed to be widespread.

J E Valdueza↗

The Nitrate/Perchlorate Ratio on Mars as an Indicator for Habitability

Discovery of indigenous martian nitrogen in Mars surface materials has important implications for habitability and the potential development of a nitrogen cycle at some point in martian history. The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) Curiosity Rover detected evolved nitric oxide (NO) gas during pyrolysis of scooped aeolian sediments and drilled mudstone acquired in Gale Crater. The detection of NO suggests an indigenous source of fixed N, and may indicate a mineralogical sink for atmospheric N2 in the form of nitrate. The ratio of nitrate to oxychlorine species (e.g. perchlorate) may provide insight into the extent of development of a nitrogen cycle on Mars.

Stern, J. C.↗

The Nitrate/Perchlorate Ratio on Mars as an Indicator for Habitability

Discovery of indigenous martian nitrogen in Mars surface materials has important implications for habitability and the potential development of a nitrogen cycle at some point in martian history. The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) Curiosity Rover detected evolved nitric oxide (NO) gas during pyrolysis of scooped aeolian sediments and drilled mudstone acquired in Gale Crater. The detection of NO suggests an indigenous source of fixed N, and may indicate a mineralogical sink for atmospheric N2 in the form of nitrate. The ratio of nitrate to oxychlorine species (e.g. perchlorate) may provide insight into the extent of development of a nitrogen cycle on Mars.

Mars↗

Electromagnetic Compatibility Test and Analysis Campaign of NASA's Mars 2020 Rover Final Submission

NASA's Mars 2020 Perseverance Rover—with a launch window opening July 2020, and landing expected February 2021—has mission objectives to look for evidence of habitability, seek biosignatures of past life, collect and cache samples for possible future return to Earth, and prepare for future human missions to Mars. The Rover platform is similar to the previous Mars Science Laboratory (MSL) “Curiosity” rover that landed in 2012 but contains a new suite of scientific instruments and upgrades to existing functionality: seven new and/or upgraded scientific payloads, an upgraded arm and sampling system, and a Helicopter demonstration. These changes—along with new efficiency goals to operate more Rover subsystems concurrently and thus collect more science—presented new electromagnetic compatibility (EMC) challenges. In this paper, we will describe the campaign to ensure Mars 2020 mission success from an electromagnetic environment perspective: 1) confirming existing MSL heritage subsystems and EMC requirements were compatible with the new Mars 2020 mission objectives, 2) engaging with engineers and scientists early in the project to identify and evaluate risks before hardware assembly and performing ambitious risk reduction tests, 3) undertaking a comprehensive subsystem qualification test program based on tailored MIL-STD-461F requirements, occasionally leading to redesign, 4) synthesizing the data collected to perform detailed analyses toward the goal of making risk-informed decisions at a system level. The spacecraft successfully completed all three planned system level tests, demonstrating self-compatibility with minimal impact to operations from electromagn

Gonzales, Edward C↗

MEDLI2: MISP Inferred Aerothermal Environment and Flow Transition Assessment

The Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite on the Mars2020 mission contained multiple sensors on the aeroshell to measure the aerothermal environment during entry into the Martian atmosphere. These sensors performed superbly and successfully returned forebody and aftbody heating measurements. Analysis of MEDLI2 data indicated flow transitioning from a laminar to turbulent state on the heatshield. No evidence of flow transition was observed on the backshell. Two methods were used to estimate flow transition times on the heatshield: (1) temperature gradient of near-surface thermocouple data and (2) heat flux gradient from an inverse reconstruction approach using thermocouple data and material response modeling. Both methods produced similar transition times with an estimated accuracy of ±1 s. To assess various transition criteria, transition parameters were evaluated at each sensor location using flow field solutions from computational fluid dynamics (CFD) simulations. The idea was to use conservative values inferred from MEDLI2 data as transition criteria for other Mars missions. To test this hypothesis, MEDLI data from the Mars Science Laboratory (MSL) mission was used to compare predicted vs. actual flow transition times. The comparisons suggest smooth wall transition criteria are not well-suited in modeling the rapid progression of a turbulent transition front. Transition criteria containing a roughness element parameter agreed better with the flight data. In summary, critical transition values derived from MEDLI2 data may be used as a starting point in constructing a flow transition model for future Mars missions.

Chun Y Tang↗

Oxychlorine Detection in Gale Crater, Mars and Implications for Past Environmental Conditions

The Sample Analysis at Mars (SAM) instrument on the Mars Science Laboratory (MSL) rover Curiosity has analyzed 3 scooped samples and 15 drilled samples since landing in 2012. Oxychlorine compounds (perchlorate/chlorate) were detected in the first 9 drilled samples but have not been detected in the last 6, starting with the Oudam sample in the Hartmann’s Valley member of the Murray formation (Table 1). Scooped samples have all contained detectable oxychlorine. These results suggest that oxychlorine formation and preservation spans the geologic record on Mars but has not been uniform spatially or temporally.

Archer, P. D., Jr.↗

Mars Reconnaissance Orbiter Navigation Strategy for Mars Science Laboratory Entry, Descent and Landing Telecommunication Relay Support

The Mars Reconnaissance Orbiter (MRO) is an orbiting asset that performs remote sensing observations in order to characterize the surface, subsurface and atmosphere of Mars. To support upcoming NASA Mars Exploration Program Office objectives, MRO will be used as a relay communication link for the Mars Science Laboratory (MSL) mission during the MSL Entry, Descent and Landing sequence. To do so, MRO Navigation must synchronize the MRO Primary Science Orbit (PSO) with a set of target conditions requested by the MSL Navigation Team; this may be accomplished via propulsive maneuvers. This paper describes the MRO Navigation strategy for and operational performance of MSL EDL relay telecommunication support.

Mars Reconnaissance Orbiter (MRO)↗

Bulk Hydrogen Content OF High-Silica Rocks in Gale Crater With the Active Dynamic Albedo of Neutrons Experiment

The Mars Science Laboratory (MSL) Curiosity rover recently traversed over plateaus of mafic aeolian sandstones (the 'Stimson' formation) that overlie mudstones (the 'Murray' formation). Within the Stimson formation we observed many lighter-toned, halo-forming features, that are potentially indicative of fluid alteration (see Fig. 1). These halo features extend for tens of meters laterally and are approx.1 meter wide. The halo features were characterized by Curiosity's geochemical instruments: Alpha Proton X-Ray Spectrometer (APXS), Chemin, Chemcam and Sample Analysis at Mars (SAM). With respect to the host (unaltered) Stimson rocks, fracture halos were significantly enriched in silicon and low in iron [1]. Changes in hydrogen abundance (due to its large neutron scattering cross section) greatly influence the magnitude of the thermal neutron response from the Dynamic Albedo of Neutrons (DAN) instrument [2]. There are also some elemental species, e.g. chlorine, iron, and nickel, that have significant microscopic neutron absorption cross sections. These elements can be abundant and variable results provide a useful estimate of the lower bound for bulk hydrogen content (assuming a homogeneous distribution).

Gabriel, T. S. J.↗

Progress Towards Modeling the Mars Science Laboratory PICA-NuSil Heatshield

The data collected by the Mars Science Laboratory (MSL) Entry, Descent and Landing Instrumentation, MEDLI, have become an established reference to assess the performance of engineering models of the Phenolic Impregnated Carbon Ablator (PICA) and to validate hypersonic computational fluid dynamics (CFD) tools for entry systems. MEDLI measurements are also extensively used as validation reference for current developments of high-fidelity material response models for PICA. So large has been the scientific output and impact of MEDLI that a follow-up instrumentation suite MEDLI2 is underway for the upcoming Mars 2020 mission.A feature neglected thus far in the modeling of the MSL heatshield, is the presence of a silicone-based room temperature vulcanizing coating designated NuSil CV-1144-0. NuSil was used to coat the entire MSL heatshield, including the MEDLI plugs, to mitigate the spread of phenolic dust from PICA, and limit contamination during clean room operations. NuSil CV-1144-0 is a space grade siloxane copolymer, designed as an oxygen protection barrier for extreme low temperature environment.Assessments conducted during MSL development demonstrated that the presence of NuSil had no adverse effect on the performance of PICA. However, evidence from ground testing of PICA-NuSil (PICA-N) models in the HyMETS arc-jet test facility suggests that the silicone changes the high temperature response of PICA. It is therefore critical to assess the importance of modeling the coating in ongoing code validation efforts.

Bessire, Brody K.↗

Progress Towards Modeling the Ablation Response of NuSil-Coated PICA

The Mars Science Laboratory (MSL) Entry, Descent and Landing Instrumentation (MEDLI) collected in-flight data largely used by the ablation community to verify and validate physics-based models for the response of the Phenolic Impregnated Carbon Ablator (PICA) material [1-4]. MEDLI data were recently used to guide the development of NASA’s high-fidelity material response models for PICA, implemented in the Porous material Analysis Toolbox based on OpenFOAM (PATO) software [5-6]. A follow-up instrumentation suite, MEDLI2, is planned for the upcoming Mars 2020 mission [7] after the large scientific impact of MEDLI. Recent analyses performed as part of MEDLI2 development draw the attention to significant effects of a protective coating to the aerothermal response of PICA. NuSil, a silicone-based overcoat sprayed onto the MSL heatshield as contamination control, is currently neglected in PICA ablation models. To mitigate the spread of phenolic dust from PICA, NuSil was applied to the entire MSL heatshield, including the MEDLI plugs. NuSil is a space grade designation of the siloxane copolymer, primarily used to protect against atomic oxygen erosion in the Low Earth Orbit environment. Ground testing of PICA-NuSil (PICA-N) models all exhibited surface temperature jumps of the order of 200 K due to oxide scale formation and subsequent NuSil burn-off. It is therefore critical to include a model for the aerothermal response of the coating in ongoing code development and validation efforts.

Meurisse, Jeremie B.↗

Relay Telecommunications for the Coming Decade of Mars Exploration

Over the past decade, an evolving network of relay-equipped orbiters has advanced our capabilities for Mars exploration. NASA's Mars Global Surveyor, 2001 Mars Odyssey, and Mars Reconnaissance Orbiter (MRO), as well as ESA's Mars Express Orbiter, have provided telecommunications relay services to the 2003 Mars Exploration Rovers, Spirit and Opportunity, and to the 2007 Phoenix Lander. Based on these successes, a roadmap for continued Mars relay services is in place for the coming decade. MRO and Odyssey will provide key relay support to the 2011 Mars Science Laboratory (MSL) mission, including capture of critical event telemetry during entry, descent, and landing, as well as support for command and telemetry during surface operations, utilizing new capabilities of the Electra relay payload on MRO and the Electra-Lite payload on MSL to allow significant increase in data return relative to earlier missions. Over the remainder of the decade a number of additional orbiter and lander missions are planned, representing new orbital relay service providers and new landed relay users. In this paper we will outline this Mars relay roadmap, quantifying relay performance over time, illustrating planned support scenarios, and identifying key challenges and technology infusion opportunities.

Edwards, C.↗

Instrumentation for Measuring Entry Radiative Heating - Past, Present, and Future

Radiative heating can be a significant contributor to the total heat load during atmospheric entry, especially for large vehicles with high entry velocties. For example, the stagnation region heat load derived from thermocouples embedded in the thermal protection system (TPS)of the Mars Science Laboratory (MSL) heatshield did not match the unmargined pre-flight predictions. This was at least partially attributed to the fact that radiative heating was not accounted for in the unmargined pre-flight predictions [2].Since MSL, significant work has been done to update radiative heating models and test how the models perform compared to ground-based test facilities such as shock tubes. The models and ground-based tests have shown that radiative heating can be significant for entry into the atmospheres of Venus, Earth, Mars, and Titan, among other planetary bodies. However, there are still discrepancies between the models and the test data, which is where the desire for flight data comes in to play. Missions that have had or are currently planned to have instrumentation to measure radiative heating during atmospheric entry are listed in Table 1.

R A Miller↗

Reconciling the Differences between the Measurements of CO2 Isotopes by the Phoenix and MSL Landers

Precise stable isotope measurements of the CO2 in the martian atmosphere have the potential to provide important constraints for our understanding of the history of volatiles, the carbon cycle, current atmospheric processes, and the degree of water/rock interaction on Mars. There have been several different measurements by landers and Earth based systems performed in recent years that have not been in agreement. In particular, measurements of the isotopic composition of martian atmospheric CO2 by the Thermal and Evolved Gas Analyzer (TEGA) instrument on the Mars Phoenix Lander and the Sample Analysis at Mars (SAM) instrument on the Mars Science Laboratory (MSL) are in stark disagreement. This work attempts to use measurements of mass 45 and mass 46 of martian atmospheric CO2 by the SAM and TEGA instruments to search for agreement as a first step towards reaching a consensus measurement that might be supported by data from both instruments.

Niles, P. B.↗

Electromagnetic Compatibility Test and Analysis Campaign of NASA's Mars 2020 Rover

NASA's Mars 2020 Rover—with a launch window opening July 2020, and landing expected February 2021—has mission objectives to look for evidence of habitability, seek biosignatures of past life, collect and cache samples for possible future return to Earth, and prepare for future human missions. The Rover platform is similar to the previous Mars Science Laboratory (MSL) “Curiosity” rover that landed in 2012 but contains a new suite of scientific instruments and upgrades to existing functionality. The scientific payload includes a trio of chemical analysis tools (PIXL, SHERLOC, SuperCam), a ground penetrating radar (RIMFAX), an upgraded weather station (MEDA), upgraded high resolution camera (MastCam-Z), and an oxygen-producing experiment (MOXIE). These changes—along with new efficiency goals to operate more Rover subsystems concurrently and thus collect more science—presented new electromagnetic compatibility (EMC) challenges. In this paper, we will describe the campaign to ensure Mars 2020 mission success from an electromagnetic environment perspective: 1) confirming existing MSL heritage subsystems and EMC requirements were compatible with the new Mars 2020 mission objectives, 2) engaging with engineers and scientists early in the project to identify and evaluate risks before hardware assembly and performing ambitious risk reduction tests, 3) undertaking a comprehensive subsystem qualification test program based on tailored MIL-STD-461F requirements, occasionally leading to redesign, 4) synthesizing the data collected to perform detailed analyses toward the goal of making risk-informed decisions at a system level. The spacecraft has successfully completed all three planned system level tests, demonstrating self-compatibility with minimal impact to operations from electromagnetic interference in all mission phases.

Gonzales, Edward C↗

Automated Targeting for the MER Rovers

The Autonomous Exploration for Gathering Increased Science System (AEGIS) will soon provide automated targeting for remote sensing instruments on the Mars Exploration Rover (MER) mission, which currently which currently has two rovers exploring the surface of Mars. Currently, targets for rover remote-sensing instruments, especially narrow field-of-view instruments (such as the MER Mini- TES spectrometer or the 2011 Mars Science Laboratory (MSL) Mission ChemCam Spectrometer), must be selected manually based on imagery already on the ground with the operations team. AEGIS enables the rover flight software to analyze imagery onboard in order to autonomously select and sequence targeted remote-sensing observations in an opportunistic fashion. In this paper, we first provide some background information on the larger autonomous science framework in which AEGIS was developed. We then describe how AEGIS was specifically developed and tested on the JPL FIDO rover. Finally we discuss how AEGIS will be uploaded and used on the Mars Exploration Rover (MER) mission in early 2009.

rover autonomy↗

Data from the Mars Science Laboratory CheMin XRD/XRF Instrument

The CheMin instrument on the Mars Science Laboratory (MSL) rover Curiosity uses a Co tube source and a CCD detector to acquire mineralogy from diffracted primary X-rays and chemical information from fluoresced X-rays. CheMin has been operating at the MSL Gale Crater field site since August 5, 2012 and has provided the first X-ray diffraction (XRD) analyses in situ on a body beyond Earth. Data from the first sample collected, the Rocknest eolian soil, identify a basaltic mineral suite, predominantly plagioclase (approx.An50), forsteritic olivine (approx.Fo58), augite and pigeonite, consistent with expectation that detrital grains on Mars would reflect widespread basaltic sources. Minor phases (each <2 wt% of the crystalline component) include sanidine, magnetite, quartz, anhydrite, hematite and ilmenite. Significantly, about a third of the sample is amorphous or poorly ordered in XRD. This amorphous component is attested to by a broad rise in background centered at approx.27deg 2(theta) (Co K(alpha)) and may include volcanic glass, impact glass, and poorly crystalline phases including iron oxyhydroxides; a rise at lower 2(theta) may indicate allophane or hisingerite. Constraints from phase chemistry of the crystalline components, compared with a Rocknest bulk composition from the APXS instrument on Curiosity, indicate that in sum the amorphous or poorly crystalline components are relatively Si, Al, Mg-poor and enriched in Ti, Cr, Fe, K, P, S, and Cl. All of the identified crystalline phases are volatile-free; H2O, SO2 and CO2 volatile releases from a split of this sample analyzed by the SAM instrument on Curiosity are associated with the amorphous or poorly ordered materials. The Rocknest eolian soil may be a mixture of local detritus, mostly crystalline, with a regional or global set of dominantly amorphous or poorly ordered components. The Rocknest sample was targeted by MSL for "first time analysis" to demonstrate that a loose deposit could be scooped, sieved to <150 microns, and delivered to instruments in the body of the rover. A drilled sample of sediment in outcrop is anticipated. At the time of writing this abstract, promising outcrops are in range and this talk will provide an update on data collected with the CheMin instrument.

Vaniman, David↗