CompLaB v1.0: a scalable pore-scale model for flow, biogeochemistry, microbial metabolism, and biofilm dynamics

Abstract. Microbial activity and chemical reactions in porous media depend on the local conditions at the pore scale and can involve complex feedback with fluid flow and mass transport. We present a modeling framework that quantitatively accounts for the interactions between the bio(geo)chemical and physical processes and that can integrate genome-scale microbial metabolic information into a dynamically changing, spatially explicit representation of environmental conditions. The model couples a lattice Boltzmann implementation of Navier–Stokes (flow) and advection–diffusion-reaction (mass conservation) equations. Reaction formulations can include both kinetic rate expressions and flux balance analysis, thereby integrating reactive transport modeling and systems biology. We also show that the use of surrogate models such as neural network representations of in silico cell models can speed up computations significantly, facilitating applications to complex environmental systems. Parallelization enables simulations that resolve heterogeneity at multiple scales, and a cellular automaton module provides additional capabilities to simulate biofilm dynamics. The code thus constitutes a platform suitable for a range of environmental, engineering and – potentially – medical applications, in particular ones that involve the simulation of microbial dynamics.

58 GEOSCIENCES↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis – Simulated Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wind turbine. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen . While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the simulated wind energy profiles, NLR used OpenFAST to simulate a 3.4-MW International Energy Agency (IEA) reference wind turbine. The hour-long wind energy profiles varied over wind turbulence intensity (Class A or Class C) and average wind speed (5, 7, or 9 m/s). To match the power limits of the 1.25-MW electrolyzer and 3.4-MW IEA wind turbine most effectively and to maximize the efficiency of hydrogen production at a given average wind speed, the profiles were sometimes scaled by two times. This means that, in some cases, the experimental setup assumed two 1.25-MW electrolyzers were coupled with the wind turbine, representing a total maximum electrolysis load of 2.5 MW. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}-{average wind speed}-{turbulence class}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “windIEA3.4-5ms-C_2-400.zip” represents the hour-long experiment using the IEA 3.4-MW turbine, subjected to an average wind speed of 5 m/s and Class C wind turbulence, and connected to two 1.25-MW electrolyzers with the power supply set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wind turbine power. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

High Power Density, Carbon Neutral Electrical Power Generation for Air Vehicles

The synergistic integration of a Solid Oxide Fuel Cell-Combustor (SOFC-C) with a turbogenerator (TG) will provide a very high fuel-to-electricity conversion efficiency while maintaining high power-to-weight ratio during high-altitude flight. The proposed SOFC-C-TG power generation technology exceeds the REEACH technical performance targets (TPT). This unique concept addresses many of the challenges faced in all electric propulsion-based aviation. The system has high part-load efficiency (more than 65% lower heating value (LHV)) during long cruise times, load following capability, high-power capacity at high altitudes adapting to low temperatures and pressures, rapid startup time of less than 30 minutes (proven with current SOFC technology), high power density (more than 3.2 kW/kg), efficient thermal management, and a foundation for a compact, efficient electrical storage and power generation system (ESPG). The SOFC-C concept achieves the technology targets by reducing the complexity of traditional fuel cell-gas turbine hybrid systems (FC-GT). The SOFC-C does not require heat exchangers and dramatically reduces the balance of plant increasing power density and performance in efficiency. The reduction in mass through elimination of heat exchangers, external reformer, and other components dramatically decreases the overall thermal dampening of the system which enables rapid startup and load following capability. Direct control of the cathode inlet temperature of the SOFC-C enables rapid warm-up of the SOFC tubes with the ability to reach operating temperature and full power in less than 30 minutes.

03 NATURAL GAS↗

Gas-Liquid Flow Modeling for Renewable Fuels Production

Aerobic/anaerobic and gas fermentation pathways have emerged as promising new technologies for the generation of renewable fuels/chemicals from biomass derived sugars, and mixtures of greenhouse/energy rich gas streams (CO2/CH4/H2/CO) via microbial action. Example pathways include sugars-to-ethanol conversion, biomethanation (CO2/H2 to CH4), biogas upgrading, CO fermentation and wet-waste conversion. Gas and liquid phase transport, mass-transfer, and mixing physics at large length scales can significantly affect microbial conversion rates, particularly when the microbial reaction requires a narrow set of conditions. These phenomena are difficult to study in small-scale bench-top reactors that are typically well-mixed. Predictive computational fluid dynamics (CFD) based simulations can therefore aid in the scale-up, design and optimization of these reactors. This work presents multiphase Euler-Euler CFD simulations of at-scale (~500 m3) bioreactors. Our mathematical model treats the gas and liquid as interpenetrating phases. This approach reduces the computational complexity of tracking individual gas bubbles that are several orders of magnitude smaller than reactor dimensions. We solve the Reynolds averaged Navier-Stokes (RANS) multiphase equations that account for phase and chemical species transport, interphase mass and momentum transfer and uses a phenomenological model for gas uptake by microbes. We use a customized solver derived from open-source CFD toolbox, OpenFOAM [1], to perform these simulations, which has been validated against small-scale reactors in our previous work [2]. There is currently a knowledge-gap regarding bubble-size distributions when using gas mixtures with vastly different properties, which can have a significant impact overall mass-transfer. For example, hydrogen bubbles are more buoyant compared to other relatively heavier gases (CO2/CH4/CO), resulting in a large distribution of residence times and bubble sizes. This work therefore develops a deeper understanding of bubble dynamics and interphase mass transfer in such heterogenous gas mixtures through well-resolved computational models. We use a population balance model (PBM) for bubble-size-distribution modeling that is validated against small-scale experiments in our solver with an uncertainty quantification study for bubble coalescence and break-up model parameters. Results pertaining to multiple simulations of gas-fermentation reactors are presented where gas mixtures with varying compositions of CO2/CH4/CO/H2 are imposed at the sparger boundaries. The spatio-temporal variations in bubble-size distribution and mass transfer coefficient are analyzed for varying superficial velocities and gas-compositions for varying sizes of bubble-column and airlift reactors. This work will also examine the performance of different reactor designs, viz. bubble column reactor, airlift reactor with an internal draft tube, and a stirred-tank reactor with Rushton impellers. Reactor mass-transfer coefficient, gas hold-up, and dissolved gas distribution are critically analyzed among reactors, and sensitivity studies pertaining to gas flow rates and reactor geometry will be presented. [1] Weller, H., Tabor, G., Jasak, H. and Fureby, C., A tensorial approach to computational continuum mechanics using object-oriented techniques, Computers in physics, 12, 6, 620--631, 1998. [2] Rahimi, M., Sitaraman, H., Humbird, D. and Stickel, J., Computational fluid dynamics study of full-scale aerobic bioreactors: Evaluation of gas-liquid mass transfer, oxygen uptake, and dynamic oxygen distribution, Chemical Engineering Research and Design, 139: 283-295.

BIOMASS FUELS↗

Development of aerosol activation in the double-moment Unified Model and evaluation with CLARIFY measurements

Representing the number and mass of cloud and aerosol particles independently in a climate, weather prediction or air quality model is important in order to simulate aerosol direct and indirect effects on radiation balance. Here we introduce the first configuration of the UK Met Office Unified Model in which both cloud and aerosol particles have “double-moment” representations with prognostic number and mass. The GLObal Model of Aerosol Processes (GLOMAP) aerosol microphysics scheme, already used in the Hadley Centre Global Environmental Model version 3 (HadGEM3) climate configuration, is coupled to the Cloud AeroSol Interacting Microphysics (CASIM) cloud microphysics scheme. We demonstrate the performance of the new configuration in high-resolution simulations of a case study defined from the CLARIFY aircraft campaign in 2017 near Ascension Island in the tropical southern Atlantic. We improve the physical basis of the activation scheme by representing the effect of existing cloud droplets on the activation of new aerosol, and we also discuss the effect of unresolved vertical velocities. We show that neglect of these two competing effects in previous studies led to compensating errors but realistic droplet concentrations. While these changes lead only to a modest improvement in model performance, they reinforce our confidence in the ability of the model microphysics code to simulate the aerosol–cloud microphysical interactions it was designed to represent. Capturing these interactions accurately is critical to simulating aerosol effects on climate.

54 ENVIRONMENTAL SCIENCES↗

Comparing Liquid Vortex Capture & the Rapid Droplet Sampling Interface for Single Cell Mass Spectrometry

High-throughput single-cell mass spectrometry is a rapidly evolving field that requires innovative sampling and ionization techniques to balance speed, sensitivity, and reliability for metabolomic and lipidomic analyses. This study provides a comparative analysis of two cutting-edge ionization platforms for single-cell analysis: Liquid Vortex Capture (LVC) and Rapid Droplet Sampling Interface (RDSI). The performance was benchmarked by testing pharmaceuticals, EquiSPLASH, and single-cell experiments. RDSI demonstrated up to 100-fold improvements in sensitivity for drugs and lipids such as propranolol, amiodarone, atorvastatin, and phosphocholines in water and phosphate-buffered solutions. This was attributed to its low-flow rate operation (3 μL/min) and reduced dilution. Conversely, LVC excelled in handling higher liquid volumes with greater reproducibility due to its higher solvent flow rate (200 μL/min), enabling increased dilution, solubility, and cleaning. Single-cell uptake of atorvastatin incubated for 10 min, or amiodarone incubated for 24 h in HepG2 cells, similarly revealed up to 85-fold enhancement in sensitivity by RDSI for drugs and lipids. These findings highlight the potential of RDSI for enhancing sensitivity in single-cell drug monitoring and lipidomics.

Cahill, John [ORNL] (ORCID:0000000298664010)↗

Search for jet quenching with dijets from high-multiplicity pPb collisions at $\sqrt{s_{NN}}$ = 8.16 TeV

The first measurement of the dijet transverse momentum balance xj in proton-lead (pPb) collisions at a nucleon-nucleon center-of-mass energy of $\sqrt{s_{NN}}$ = 8.16 TeV is presented. The xj observable, defined as the ratio of the subleading over leading jet transverse momentum in a dijet pair, is used to search for jet quenching effects. The data, corresponding to an integrated luminosity of 174.6 nb −1 , were collected with the CMS detector in 2016. The x j distributions and their average values are studied as functions of the charged-particle multiplicity of the events and for various dijet rapidity selections. The latter enables probing hard scattering of partons carrying distinct nucleon momentum fractions x in the proton- and lead-going directions. The former, aided by the high-multiplicity triggers, allows probing for potential jet quenching effects in high-multiplicity events (with up to 400 charged particles), for which collective phenomena consistent with quark-gluon plasma (QGP) droplet formation were previously observed. The ratios of x j distributions for high- to low-multiplicity events are used to quantify the possible medium effects. These ratios are consistent with simulations of the hard-scattering process that do not include QGP production. These measurements set an upper limit on medium-induced energy loss of the subleading jet of 1.26% of its transverse momentum at the 90% confidence level in high multiplicity pPb events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of Variable Gas Mixtures on Bubble Size Distribution and Mass Transfer in Gas Fermentation Reactors

Gas fermentation has emerged as a promising new technology for the generation of fuels and chemicals from mixtures of greenhouse and energy rich gas streams (CO2/CH4/H2/CO) via microbial bioreaction. Example pathways include biomethanation (CO2/H2 to CH4), biogas upgrading, CO fermentation and wet-waste conversion. Effective Gas-liquid mass-transfer is an important physical phenomenon that determines the design and scale-up of these systems. There is currently a knowledge-gap regarding bubble-size distributions when using a mixture of gases with vastly different properties, which can have a significant impact on overall mass-transfer. For example, hydrogen bubbles are more buoyant compared to other relatively heavier gases (CO2/CH4/CO), resulting in a large distribution of residence times and bubble sizes. This work therefore develops a deeper understanding of bubble dynamics and interphase mass transfer in such heterogenous gas mixtures through well-resolved computational models. We use a detailed multiphase computational-fluid-dynamics (CFD) model to study the impact of gas-mixtures on overall mass-transfer in bubble column and air-lift reactors. The CFD tool previously developed by the authors (1) for simulating aerobic fermentation reactors at scale is used in this study. The Reynolds-averaged mass, momentum, energy, and species transport equations are solved for interpenetrating gas and liquid phase in this model. We use a population balance-based bubble-size-distribution model that is validated against small-scale experiments in our solver. Results pertaining to multiple simulations of gas-fermentation reactors are presented where gas mixtures with varying compositions of CO2/CH4/CO/H2 are imposed at the sparger boundaries. The spatio-temporal variations in bubble-size distribution and mass transfer coefficient is analyzed for varying superficial velocities and gas-compositions for varying sizes of bubble-column and airlift reactors.

BIOMASS FUELS,MATHEMATICS AND COMPUTING↗

Impacts of Soil Microbiome Variations on Root Colonization by Fungi and Bacteria and on the Metabolome of Populus tremula × alba

Trees depend on beneficial interactions between roots and soil microbes for their nutrition and protection against stresses. The soil microbiome provides the main reservoir of microbes for root colonization and is subject to natural variations that can affect its composition. It is not clear whether the tree’s root system is able to buffer the natural variations occurring in the soil microbiome to capture a stable and effective microbiome or whether these variations affect its microbiome to impact its physiology. To address this question, we planted cuttings of Gray Poplar (Populus tremula × alba clone 717-1B4) in natural soil taken from a poplar stand under the same tree over two consecutive years and grew them in a greenhouse. We analyzed the soil and root microbiomes by high throughput Illumina MiSeq sequencing of fungal rDNA internal transcribed spacer and bacterial 16S rRNA amplicons and we characterized the root metabolome by gas chromatography-mass spectrometry. Soil and root microbial communities significantly shifted over the 2 years. A modification of the balance between endophytes, saprophytes, and mycorrhizal fungi occurred in the roots as well as a replacement of some dominant operational taxonomic units by others. These modifications were correlated with a significant alteration of the levels of about 10% of primary and secondary metabolites, suggesting that natural fluctuations in soil microbial communities can have a profound impact on tree root metabolism and physiology. Tree roots functioning may thus be indirectly strongly affected by the effects of future extreme climatic variations on the soil microbiome.

59 BASIC BIOLOGICAL SCIENCES↗

Assessing the sensitivity of aerosol mass budget and effective radiative forcing to horizontal grid spacing in E3SMv1 using a regional refinement approach

Abstract. Atmospheric aerosols have important impacts on air quality and the Earth–atmospheric energy balance. However, as computing power is limited, Earth system models generally use coarse spatial grids and parameterize finer-scale atmospheric processes. These parameterizations and the simulation of atmospheric aerosols are often sensitive to model horizontal resolutions. Understanding the sensitivities is necessary for the development of Earth system models at higher resolutions with the deployment of more powerful supercomputers. Using the Energy Exascale Earth System Model (E3SM) version 1, this study investigates the impact of horizontal grid spacing on the simulated aerosol mass budget, aerosol–cloud interactions, and the effective radiative forcing of anthropogenic aerosols (ERFaer) over the contiguous United States. We examine the resolution sensitivity by comparing the nudged simulation results for 2016 from the low-resolution model (LR) and the regional refinement model (RRM). As expected, the simulated emissions of natural dust, sea salt, and marine organic matter are substantially higher in the RRM than in the LR. In addition, RRM simulates stronger aqueous-phase production of sulfate through the enhanced oxidation of sulfur dioxide by hydrogen peroxide due to increased cloud liquid water content. In contrast, the gas-phase chemical production of sulfate is slightly suppressed. The RRM resolves more large-scale precipitation and produces less convective precipitation than the LR, leading to increased (decreased) aerosol wet scavenging by large-scale (convective) precipitation. Regarding aerosol effects on clouds, RRM produces larger temporal variabilities in the large-scale liquid cloud fractions than LR, resulting in increased microphysical cloud processing of aerosols (more interstitial aerosols are converted to cloud-borne aerosols via aerosol activation) in RRM. Water vapor condensation is also enhanced in RRM compared to LR. Consequently, the RRM simulation produces more cloud droplets, a larger cloud droplet radius, a higher liquid water path, and a larger cloud optical depth than the LR simulation. A comparison of the present-day and pre-industrial simulations indicates that, for this contiguous United States domain, the higher-resolution increases ERFaer at the top of the model by about 12 %, which is mainly attributed to the strengthened indirect effect associated with aerosol–cloud interactions.

54 ENVIRONMENTAL SCIENCES↗

Fuel cells for single-aisle regional aircraft: System configuration, performance and cost

A hydrogen fuel cell propelled electric aircraft can compete with incumbent turbofan technologies for single-aisle regional aircraft by coupling design of stack, air handling, thermal management, propulsion, and airframe to optimize performance. The stack operates at 95°C to facilitate heat rejection during take-off and below 75°C during cruise to extend lifetime and is oversized to satisfy power requirements at end of life. A multi-stage turbocompressor with a compression ratio >10 is selected to reach high stack power density at 11,300-m cruise altitude. The propulsion system is configured to accommodate air handling within the core duct, an inclined heat exchanger in the outer duct to limit the nacelle size, and variable area nozzles to independently control mass flows through the core and bypass ducts. The airframe is modified for maximum lift coefficient and longer balanced field length for dramatically reduced thrust during take-off, and the fuselage is stretched by 20% to store liquid hydrogen (LH 2 ). Modularization of power systems promotes safety in one engine inoperative scenarios and allows reaching specific power metrics for stack, balance-of-plant and fuel cell system (FCS), necessary for acceptable take-off weight. In conclusion, cost parity requires increase in FCS lifetime, LH 2 cost reduction, and improved FCS specific power.

Catalyst durability↗

PPI DataHub Project Data Package: S. elongatus PCC 7942 Circadian Control Bioproduction Metabolomics (PB-DP5)

The purpose of this experiment was to evaluate how circadian clock regulation impacts carbon partitioning between storage, growth, and product synthesis in Synechococcus elongatus PCC 7942 in providing insights to strategies for enhanced bioproduction. Culture samples were collected at 0, 0.5, 1, 2, 4, 6, and 8 hours for extracellular sucrose analysis. Circadian metabolomics data was acquired using a Agilent single quadrupole gas chromatography-mass spectrometer and processed using Agilent Mass Hunter for targeted sucrose quantification. Metabolomic analysis of PCC 7942 light-dark cycle cultures transitioned to constant light revealed distinct temporal patterns in sucrose production. Processed metabolomic datasets are openly accessible from the PNNL DataHub project dataset download page and contain secondary processed GC-MS results files and supporting metadata materials linked to relevant source code information supporting data transparency and reuse.

59 BASIC BIOLOGICAL SCIENCES↗

Extreme Heating of Minor Ions in Imbalanced Solar-wind Turbulence

Minor ions in the solar corona are heated to extreme temperatures, far in excess of those of the electrons and protons that comprise the bulk of the plasma. These highly nonthermal distributions make minor ions sensitive probes of the collisionless processes that heat the corona and power the solar wind. The recent discovery of the "helicity barrier" offers a mechanism in which imbalanced Alfvénic turbulence in low-β plasmas preferentially heats protons over electrons, generating high-frequency, proton-cyclotron-resonant fluctuations. We use the hybrid-kinetic particle-in-cell code Pegasus++ to drive imbalanced Alfvénic turbulence in a 3D low-β plasma with additional passive ion species, He 2+ and O 5+ . A helicity barrier naturally develops, followed by clear phase-space signatures of oblique proton-cyclotron-wave heating and Landau-resonant heating from the imbalanced Alfvénic fluctuations. The former results in characteristically arced ion velocity distribution functions, whose non-bi-Maxwellian features are shown by linear ALPS calculations to be critical to the heating process. Additional features include a steep transition-range electromagnetic spectrum, proton-cyclotron waves propagating in the direction of the imbalance, significantly enhanced proton-to-electron heating ratios, ion temperatures that are considerably more perpendicular with respect to magnetic field, and extreme heating of heavier species in a manner consistent with mass scalings inferred from spacecraft measurements. None of these features are realized in an otherwise equivalent simulation of balanced turbulence. If seen simultaneously in the fast solar wind, these signatures of the helicity barrier would testify to the necessity of incorporating turbulence imbalance in a complete theory for the evolution of the solar wind.

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of a Tapered Impact Damper for Traffic Signal Structure Vibrations Using the Method of Harmonic Balance

Significant vibration amplitudes and cycles can be produced when traffic signal structures with low inherent damping are excited near one of their natural frequencies. For the mitigation of wind-induced vibrations, dynamic vibration absorbers coupled to the structure are often used. Here, this research investigates the performance of a tapered impact damper, consisting of a hanging spring-mass oscillator inside a housing capable of reducing vibration amplitude over a broader frequency range than the conventional tuned mass damper. A nonlinear, two degree-of-freedom model is developed with coordinates representing the traffic structure and the tapered impact damper. This research focuses on the application of the harmonic balance method to approximate the periodic solutions of the nonlinear equations to compute the nonlinear dynamics of the damped traffic signal structure. After designing and manufacturing a tapered impact damper, the traffic signal structure is tested with and without the damper using free vibration snapback tests. The experimental frequency and damping backbone curves are used to validate the analytical model, and the effectiveness of the damper is discussed.