Search NASA⌕ Search

SEARCH · Search NASA

Results for “Materials Test Module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Dendritic web-type solar cell mini-modules

Twenty-five minimodules composed of dendritic web solar cells with nominal glass size of 12 by 40 cm were provided for study. The modules were identical with respect to design, materials, and manufacturing and assembly processes to full scale modules. The modules were also electrically functional. These minimodules were fabricated to provide test vehicle for environmental testing and to assess reliability of process and design procedures. The module design and performance are outlined.

Campbell, R. B.↗

Advancements in oxygen generation and humidity control by water vapor electrolysis

Regenerative processes for the revitalization of manned spacecraft atmospheres or other manned habitats are essential for realization of long-term space missions. These processes include oxygen generation through water electrolysis. One promising technique of water electrolysis is the direct conversion of the water vapor contained in the cabin air to oxygen. This technique is the subject of the present program on water vapor electrolysis development. The objectives were to incorporate technology improvements developed under other similar electrochemical programs and add new ones; design and fabricate a mutli-cell electrochemical module and a testing facility; and demonstrate through testing the improvements. Each aspect of the water vapor electrolysis cell was reviewed. The materials of construction and sizing of each element were investigated analytically and sometime experimentally. In addition, operational considerations such as temperature control in response to inlet conditions were investigated. Three specific quantitative goals were established.

Heppner, D. B.↗

HYTEST Phase I Facility Commissioning and Modeling

The purpose of this document is to report the first year accomplishments of two coordinated Laboratory Directed Research and Development (LDRD) projects that utilize a hybrid energy testing laboratory that couples various reactors to investigate system reactance behavior. This work is the first phase of a series of hybrid energy research and testing stations - referred to hereafter as HYTEST facilities – that are planned for construction and operation at the Idaho National Laboratory (INL). A HYTEST Phase I facility was set up and commissioned in Bay 9 of the Bonneville County Technology Center (BCTC). The purpose of this facility is to utilize the hydrogen and oxygen that is produced by the High Temperature Steam Electrolysis test reactors operating in Bay 9 to support the investigation of kinetic phenomena and transient response of integrated reactor components. This facility provides a convenient scale for conducting scoping tests of new reaction concepts, materials performance, new instruments, and real-time data collection and manipulation for advance process controls. An enclosed reactor module was assembled and connected to a new ventilation system equipped with a variable-speed exhaust blower to mitigate hazardous gas exposures, as well as contract with hot surfaces. The module was equipped with a hydrogen gas pump and receiver tank to supply high quality hydrogen to chemical reactors located in the hood.

08 HYDROGEN↗

Examination of a Junction-Box Adhesion Test for Use in Photovoltaic Module Qualification (Presentation)

Engineering robust adhesion of the junction-box (j-box) is a hurdle typically encountered by photovoltaic (PV) module manufacturers during product development. There are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp heat' IEC qualification test is proposed to verify the basic robustness of its adhesion system. The details of the proposed test will be described, in addition to the preliminary results obtained using representative materials and components. The described discovery experiments examine moisture-cured silicone, foam tape, and hot-melt adhesives used in conjunction with PET or glass module 'substrates.' To be able to interpret the results, a set of material-level characterizations was performed, including thermogravimetric analysis, differential scanning calorimetry, and dynamic mechanical analysis. PV j-boxes were adhered to a substrate, loaded with a prescribed weight, and then placed inside an environmental chamber (at 85C, 85% relative humidity). Some systems did not remain attached through the discovery experiments. Observed failure modes include delamination (at the j-box/adhesive or adhesive/substrate interface) and phase change/creep. The results are discussed in the context of the application requirements, in addition to the plan for the formal experiment supporting the proposed modification to the qualification test.

14 SOLAR ENERGY↗

Degradation in Photovoltaic Encapsulant Transmittance: Results of the Second PVQAT TG5 Artificial Weathering Study

The optical degradation of encapsulants from ultraviolet (UV) radiation has historically resulted in a significant loss in performance throughout the life of a photovoltaic (PV) module. International Electrotechnical Commission (IEC) test methods have recently been developed to screen for PV encapsulants prone to loss in optical performance. The present study was performed to benchmark polymeric packaging materials relative to IEC 62788-1-4 (covering the measurement of optical transmittance) and IEC 62788-1-7 (on the durability of transmittance), provide feedback toward improvement of the methods, and develop insight regarding optical degradation. Contemporary materials were examined, including poly(ethylene-co-vinyl acetate) (EVA), thermoplastic polyolefin (TPO), polyolefin elastomer (POE), and polyvinyl butyral (PVB) encapsulants; a poly(ethene-co-tetrafluoroethene)/poly(ethylene terephthalate) (ETFE/PET) transparent backsheet; and a polystyrene (PS) working reference material. The use of silica-, specialty-, and rolled-glass was also compared in laminated coupons. Specimen size was separately examined from 2.5 to 12.5 cm. Weathering was performed with a xenon source, using IEC TS 62788-7-2 methods A2, A3, A4, and A5 (chamber temperature of 55 degrees C, 65 degrees C, 75 degrees C, or 85 degrees C), respectively. Characterizations were made using a UV-visible-near-infrared (UV-VIS-NIR) spectrophotometer (transmittance and reflectance, with and without an integrating sphere), a UV-VIS fluorescence spectrophotometer, a camera, and an optical microscope. Performance was analyzed, including solar weighted transmittance, yellowness index, UV cut-off wavelength, and haze (scattering). Separate Arrhenius analyses were performed to assess retention of transmittance and changes in yellowness index. The activation energy for both characteristics was found to range from 15-80 kJ mol-1, with an average of 48 kJ mol-1, similar to the average of 45 kJ mol-1 identified in the previous international PV Quality Assurance Task Force (PVQAT) Task Group 5 (TG5) study of more traditional encapsulants. The separate degradation modes of discoloration and scattering were distinguished in the encapsulants using a comprehensive spectral characterization. Based on these results, the IEC 62788-1-7 pass/fail criteria of 5% change in transmittance was confirmed to identify a known bad encapsulant.

durability↗

Mathematics Integrated with Computer Science through Scratch: Curricular Modules for the Middle Grades

A project funded by the National Science Foundation, Computer Science Integrated with Mathematics in Middle Schools (CSIMMS) (DRL-1640039), brought middle-school mathematics teachers together with university computer science (CS) faculty and STEM education faculty to design, develop, and test curriculum modules in which CS is integrated into instruction for middle-school general-mathematics courses. The project developed integrated math/CS curriculum modules (for grades 6, 7, and 8), complete with student tasks and teacher materials to guide classroom implementation. Across the project, sixteen teachers from four middle schools representing different school contexts (both urban and suburban, serving students from a range of demographic and socioeconomic backgrounds) participated as members of the design team and trial testers of the math/CS modules. All modules underwent multiple years of testing and refinement, with extensive input from the teachers who co-designed and implemented them. Approximately 50-100 middle-school students participated in the classes of those who taught each year. The modules in this volume feature a range of models for integrating mathematics and computer science at the 6th and 7th grade levels. All modules foreground the teaching of grade-level mathematics content, with computer science functioning to motivate and/or reinforce these ideas.

Andrews larson, Christine↗

NDT System for Metal Components in Concrete Structures (Final Report)

Steel reinforcements embedded within concrete can corrode and crack, leading to weakening of the structures, and existing NDT (non-destructive testing) techniques do not provide the full picture. Condition assessment is critical in evaluating these structures in order to ensure safe, long-term operation of the nuclear power plants. Improved NDT techniques are needed as the nation’s generating stations age and require action based on increasingly critical inspection data. The power industry uses eddy current test (ECT) during in-service inspections to detect and monitor defects such as cracks and corrosion in metals, particularly metal pipes. However, the detection of defects in the reinforcing steel embedded in concrete is far more challenging for numerous reasons. Primary among them is the concrete layer’s thickness, which prevents the ability to have a close proximity between sensor and metallic sample. One solution to this problem is to create a higher sensitivity technique which can inspect at depth, with good spatial resolution and excellent directional sensitivity, to isolate the metal buried deep in the concrete and characterize defects in the metal. The goal of the phase II research program was to study and develop a new reinforced concrete NDT technology based on anisotropic magnetoresistive (AMR) sensors designed specifically for ECT of steel reinforcements in concrete. The first technical objective was to demonstrate the capability of inspecting steel reinforcement structures, including metal rebar and tensioning cable at or below 6” of depth embedded in concrete. Another objective was to be able to confidently identify multiple layers of reinforcements at varying depths. In addition, the technique needed to be able to provide condition assessment of the metal, providing data on the structure and positioning of the steel members, material loss, and detection of the presence of breaks. An important part of the research and development was aimed at achieving superior performance compared to existing technology. The ability to detect corrosion breaks in unbonded multi-wire and multi-strand tendons was another important objective. The final objective that led to a successful program was to build a complete prototype portable scanning system capable of demonstrating the probe performance in the field. All of these objectives were met, which provided data for the system development work going forward. RMD worked with the engineering firm Simpson Gumpertz & Heger to develop a detailed problem definition for concrete structures and the necessary sensor specifications. In addition, we developed finite element simulation models for the eddy current based NDT system through the analysis of the electromagnetic (EM) properties of sample materials and the orientation of the transmitter, sensor array (receivers), metal, and intervening materials like concrete and air. Based on the modeling and specifications, we designed and fabricated prototype sensor modules. We then acquired and fabricated test samples to characterize and optimize the sensors. Finally, we built a complete prototype for testing on actual concrete structures. This new NDT technology has high promise for greatly improving capabilities in the inspection of steel reinforcements within concrete structures, such as rebar, liners, anchors, and prestressing cables. This method could be valuable in the maintenance of nuclear power plants, and many other structures critical to our nation’s infrastructure.

42 ENGINEERING↗

Thermal performance and radio-frequency transmissivity of candidate ablation materials for S-band antenna window application on manned spacecraft

A test program was conducted in the MSC 1.5 MW arc-heated facility to evaluate the thermal performance of ablation materials having potential application as radio frequency windows. These tests were conducted for the improvement of omnidirectional antenna operating characteristics during atmospheric reentry. Since a full scale model of the Apollo command service module was available for antenna tests, this mockup was used as a basic for the tests. Test models were subjected to heating conditions simulating the nominal lunar return trajectory (AS-501) and the design trajectories, high heat load and high heating rate. RF measurements were made before and after the arc jet tests to measure attenuation effects due to the thermal degradation of the materials under consideration. The test program demonstrated that additional development is required in materials technology to achieve an ablative system with both good RF transmission characteristics and thermal-structural integrity.

Tillian, D. J.↗

Utilizing Photogrammetry and Strain Gage Measurement to Characterize Pressurization of Inflatable Modules

This paper focuses on integrating a large hatch penetration into inflatable modules of various constructions. This paper also compares load predictions with test measurements. The strain was measured by utilizing photogrammetric methods and strain gages mounted to select clevises that interface with the structural webbings. Bench testing showed good correlation between strain data collected from an extensometer and photogrammetric measurements, even when the material transitioned from the low load to high load strain region of the curve. The full-scale torus design module showed mixed results as well in the lower load and high strain regions. After thorough analysis of photogrammetric measurements, strain gage measurements, and predicted load, the photogrammetric measurements seem to be off by a factor of two.

Mohammed, Anil↗

Incidental Testicular Irradiation From Prostate IMRT: It All Adds Up

Purpose: To identify the technical aspects of image-guided intensity-modulated radiation therapy (IMRT) for localized prostate cancer that could result in a clinically meaningful incidental dose to the testes. Methods and Materials: We examined three sources that contribute incidental dose to the testes, namely, from internal photon scattering from IMRT small field and large pelvic nodal fields with 6 or 15 MV, from neutrons when >10-MV photons are used, and from daily image-guided fiducial-based portal imaging. Using clinical data from 10 patients who received IMRT for prostate cancer, and thermo-luminescent dosimeter measurements in phantom, we estimated the dose to the testes from each of these sources. Results: A mean testicular dose of 172 and 220 cGy results from internal photon scatter for pelvic nodal fields and 68 and 93 cGy for prostate-only fields, for 6- and 15-MV energies, respectively. For 15-MV photon energies, the mean testicular dose from neutrons is 60 cGy for pelvic fields and 31 cGy for prostate-only fields. From daily portal MV image guidance, the testes-in-field mean dose is 350 cGy, whereas the testes-out-of-field scatter dose is 16 cGy. Dosimetric comparisons between IMRT using 6-MV and 15-MV photon energies are not significantly different. Worst-case scenarios can potentially deliver cumulative incidental mean testicular doses of 630 cGy, whereas best-case scenarios can deliver only 84 cGy. Conclusions: Incidental dose to the testes from prostate IMRT can be minimized by opting to restrict the use of elective pelvic nodal fields, by choosing photon energies <10 MV, and by using the smallest port sizes necessary for daily image guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Planning Time and Plan Quality Through Multicriteria Optimization for Intensity-Modulated Radiotherapy

Purpose: To test whether multicriteria optimization (MCO) can reduce treatment planning time and improve plan quality in intensity-modulated radiotherapy (IMRT). Methods and Materials: Ten IMRT patients (5 with glioblastoma and 5 with locally advanced pancreatic cancers) were logged during the standard treatment planning procedure currently in use at Massachusetts General Hospital (MGH). Planning durations and other relevant planning information were recorded. In parallel, the patients were planned using an MCO planning system, and similar planning time data were collected. The patients were treated with the standard plan, but each MCO plan was also approved by the physicians. Plans were then blindly reviewed 3 weeks after planning by the treating physician. Results: In all cases, the treatment planning time was vastly shorter for the MCO planning (average MCO treatment planning time was 12 min; average standard planning time was 135 min). The physician involvement time in the planning process increased from an average of 4.8 min for the standard process to 8.6 min for the MCO process. In all cases, the MCO plan was blindly identified as the superior plan. Conclusions: This provides the first concrete evidence that MCO-based planning is superior in terms of both planning efficiency and dose distribution quality compared with the current trial and error-based IMRT planning approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of breakdown-voltage of contemporary and veteran photovoltaic backsheets

The ability of designated electrically insulating materials in a module, including the backsheet, to act as insulators is a key safety requirement for photovoltaic technology. The recently developed test standards IEC TS 62788-2 (including a method for direct-current breakdown-voltage) and IEC TS 62788-7-2 (for ultraviolet [UV] weathering) are examined for the first time together in this study. Thirty-six contemporary backsheets were compared using the breakdown-voltage test, before and after UV weathering, according to the recent A3 test condition. Twenty-eight backsheets, extracted from a variety of veteran photovoltaic modules, were also examined using the breakdown test. Additional characterizations were performed to interpret the breakdown-voltage results, including: surface and cross-sectional optical microscopy failure analysis; cross-sectional scanning electron (SEM) microscopy with EDS energy-dispersive X-ray spectroscopy (EDX) failure analysis; Fourier-transform infrared spectroscopy (FTIR) to identify the base resin and its chemical integrity; and differential scanning calorimetry (DSC) to identify phase transitions that might adversely affect degradation during weathering. The electrical insulation for the backsheets is discussed relative to: the industry safety requirement; features observed to facilitate the degradation of insulation; the validity of the artificial UV weathering test; the validity of the sheet geometry used for specimens in this study; and the validity of subsequent mechanical testing.

14 SOLAR ENERGY↗

Asymmetrically driven implosions

Techniques to achieve uniform near-spherical symmetry of radiation drive on a capsule in a laser-heated hohlraum have received detailed attention in the context of inertial confinement fusion. However, much less attention has been paid to the understanding of the hohlraum physics in cases where the radiation drive departs significantly from spherical symmetry. A series of experiments has been carried out to study the implosion dynamics of a capsule irradiated by a deliberately asymmetric x-ray drive. The experimental data provide a sensitive test of radiation transport in hohlraums in which drive symmetry is modulated by asymmetric laser beam timing and the use of wall materials of different albedos. Data from foam ball and thin-shell capsule experiments are presented together with modeling using consecutively linked Lagrangian and Eulerian calculational schemes. The thin-shell capsules exhibit much stronger sensitivity to early-time asymmetry than do the foam balls, and this sensitivity results in the formation of a well-defined polar jet. These data are shown to challenge computational modeling in this highly asymmetric convergent regime. All of the experiments detailed were carried out at the OMEGA laser facility [J. M. Soures, R. L. McCrory, C. P. Verdon et al., Phys. Plasmas 3, 2108 (1996)] at the Laboratory for Laser Energetics in Rochester, NY.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effluent Treatment Facility Catalyst Testing

ETF needs to bring its peroxide decomposer module back on-line in order to support the Waste Treatment and Immobilization Plant. This report discusses testing of five catalyst materials: Sud-Chemie T-2525, Carulite 200, EnviCat VOC-2531, LayneOx and a natural manganese ore. This testing looked at the amount of fines produced as well as the peroxide destruction abilities of each material. The Sud-Chemie T-2525 material had the least amount of fines and reduced the peroxide to ≤10 ppm within 30 min. The Carulite 200 and EnviCat VOC 2531 catalysts contained more fines than the T-2525 material, but also reduced the peroxide concentration to ≤10 ppm within 30 min. The Pro Ox and LayneOx materials contained the greatest amount of fines and did not reduce as much peroxide when compared to the other catalysts tested.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reducing module soiling with scalable and robust photocatalytic coatings

The air-glass interface at the front of a photovoltaic (PV) module reflects approximately 4% of incident light, decreasing the potential power output of the module by the same amount. Today’s modules reduce this loss by adding a low-refractive-index (1.25-1.30) SiO2 coating to the sunward side of the module glass; this antireflection coating recovers approximately 3% of the 4% light that would otherwise be lost. While such antireflection coatings work very well on clean, new modules, they do not inhibit soiling—the accumulation of soilants such as dust, pollen, soot, or other foreign material—on the module glass, and soilants reflect and scatter incident light. An improved coating would serve provide not only an antireflection effect, but also an anti-soiling effect. The goal of this project was to develop such a coating and provide a path for it to be manufactured in the U.S. The project successfully designed and fabricated coatings that provided >3% transmittance gain compared to bare glass (matching the performance of commercial antireflection coatings) and displayed anti-soiling behavior in standard laboratory soiling effects. This was achieved by using a Swift Coat proprietary coating deposition technique, aerosol impact-driven assembly (AIDA), to control the porosity and thus refractive index of coatings of photocatalytic materials—such as TiO2—that would otherwise increase (instead of decrease) reflection. These combined antireflection/anti-soiling coatings passed PV industry standard module reliability tests as well as coating-specific abrasion tests, showing that they have the durability needed for decades in the field. Swift Coat scaled the AIDA hardware and deposition process to make mini-modules that were monitored for nearly two years during field tests administered by a third party, as well as demonstrated scaling to the widths of full-sized modules. The fielded mini-modules outperformed reference modules (with commercial antireflection coatings) in two locations, providing a 1% absolute average performance boost and larger increases during periods of heavier soiling. Swift Coat’s cost analysis indicated a coating manufacturing cost below the sales price of today’s antireflection coatings. More than five module manufacturers sampled and assessed the coatings, and three provided letters of support. The coating developed in this project increases the energy output of PV modules, thereby decreasing the cost per kilowatt-hour of solar energy generated. Cheaper solar electricity benefits the public by accelerating the transition to a stable, affordable, carbon-free energy economy. In addition, for select applications in which PV modules are highly visible—such as on residential rooftops—the coating provides an aesthetic benefit because it stays cleaner than today’s modules. Finally, Swift Coat and its prospective customers are U.S. companies, and successful commercialization of this technology will provide U.S. jobs and a secure solar supply chain.

14 SOLAR ENERGY↗

Test-Free Fracture Toughness

Computational simulation results can give the prediction of damage growth and progression and fracture toughness of composite structures. The experimental data from literature provide environmental effects on the fracture behavior of metallic or fiber composite structures. However, the traditional experimental methods to analyze the influence of the imposed conditions are expensive and time consuming. This research used the CODSTRAN code to model the temperature effects, scaling effects and the loading effects of fiberbraided composite specimens with and without fiber-optic sensors on the damage initiation and energy release rates. The load-displacement relationship and fracture toughness assessment approach is compared with the test results from literature and it is verified that the computational simulation, with the use of established material modeling and finite element modules, adequately tracks the changes of fracture toughness and subsequent fracture propagation for any fiberbraided composite structure due to the change of fiber orientations, presence of large diameter optical fibers, and any loading conditions.

Minnetyan, Levon↗

Test-Free Fracture Toughness

Computational simulation results can give the prediction of damage growth and progression and fracture toughness of composite structures. The experimental data from literature provide environmental effects on the fracture behavior of metallic or fiber composite structures. However, the traditional experimental methods to analyze the influence of the imposed conditions are expensive and time consuming. This research used the CODSTRAN code to model the temperature effects, scaling effects and the loading effects of fiber/braided composite specimens with and without fiber-optic sensors on the damage initiation and energy release rates. The load-displacement relationship and fracture toughness assessment approach is compared with the test results from literature and it is verified that the computational simulation, with the use of established material modeling and finite element modules, adequately tracks the changes of fracture toughness and subsequent fracture propagation for any fiber/braided composite structure due to the change of fiber orientations, presence of large diameter optical fibers, and any loading conditions.

Minnetyan, Levon↗

Cost and Reliability Improvement for CIGS-Based PV on Flexible Substrate: May 24, 2006 -- July 31, 2010

Global Solar Energy rapidly advances the cost and performance of commercial thin-film CIGS products using roll-to-roll processing on steel foil substrate in compact, low cost deposition equipment, with in-situ sensors for real-time intelligent process control. Substantial increases in power module efficiency, which now exceed 13%, are evident at GSE factories in two countries with a combinedcapacity greater than 75 MW. During 2009 the average efficiency of cell strings (3780 cm2) was increased from 7% to over 11%, with champion results exceeding 13% Continued testing of module reliability in rigid product has reaffirmed extended life expectancy for standard glass product, and has qualified additional lower-cost methods and materials. Expected lifetime for PV in flexible packagescontinues to increase as failure mechanisms are elucidated, and resolved by better methods and materials. Cost reduction has been achieved through better materials utilization, enhanced vendor and material qualification and selection. The largest cost gains have come as a result of higher cell conversion efficiency and yields, higher processing rates, greater automation and improved control inall process steps. These improvements are integral to this thin film PV partnership program, and all realized with the 'Gen2' manufacturing plants, processes and equipment.

14 SOLAR ENERGY↗