Cloud Uniformity Measurement from NASA's 2nd Fundamental Ice Crystal Icing Test Part 1 (Water Content & PSD)
This paper presents water content and particle measurements from the second Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The water content measurements came from the Science Engineering Associates Multi-Element Probe and the Isokinetic Probe whereas the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments measured the particle size distribution. Ice particle accretion due to the ingestion of ice-crystals is attributed to numerous jet engine powerloss events. The NASA PSL is an altitude jet-engine test facility which has recently added a capability to inject ice particles into the flow. This work focuses on characterizing the icing cloud by traversing the instruments across the test section at four different conditions where velocity and water content were varied. For this test, the nozzle patterns were selected to make a uniform cloud in the center 6-inch diameter of the test section. Radial trends for the ice and water content measurements are presented and the melt ratio is calculated at the measurement locations. Particle size distributions are also presented. The measured water content, melt ratio, and particle size decreased moving out radially. Measured water content trends show uniformity to within 19.2% for the center 6 inches of the cloud, as intended. In addition, the total water content increased at centerline with velocity, whereas the melt ratio decreased.