Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Final Report: Operational Retrieval of Cloud Microphysical Properties Using Combined Measurements by Diverse Instruments

The report on the final phase of the project describes improvements in the ice and liquid cloud retrieval algorithms due to the use of three-parameter particle size distributions in which all three parameters may vary with height, testing of the improved retrievals by comparisons of measured and calculated fluxes, and further improvement in liquid retrievals obtained by adding liquid water path information from the microwave radiometer to radar and visible optical depth information.

58 GEOSCIENCES↗

A high temperature instrument for consecutive measurements of thermal conductivity, electrical conductivity, and Seebeck coefficient

A device for measuring a plurality of material properties is designed to include accurate sensors configured to consecutively obtain thermal conductivity, electrical conductivity, and Seebeck coefficient of a single sample while maintaining a vacuum or inert gas environment. Four major design factors are confirmed as sample-heat spreader mismatch, radiation losses, parasitic losses, and sample surface temperature variance. The design is analyzed using finite element methods for high temperature ranges up to 1000°C as well as ultra-high temperatures up to 2500°C. A temperature uncertainty of 0.46% was estimated for a sample with cold and hot sides at 905.1 and 908.5°C, respectively. The uncertainty at 1000°C was calculated to be 0.7% for a ΔT of 5°C between the hot and cold sides. The thermal conductivity uncertainty was calculated to be -8.6% at ~900°C for a case with radiative gains, and +8.2% at ~1000°C for a case with radiative losses, indicating the sensitivity of the measurement to the temperature of the thermal guard in relation to the heat spreader and sample temperature. Lower limits of -17 and -13% error in thermal conductivity measurements were estimated at the ultra-high temperature of ~2500°C for a single-stage and double-stage radiation shield, respectively. Lastly, it is noted that this design is not limited to electro-thermal characterization and will enable measurement of ionic conductivity and surface temperatures of energy materials under realistic operating conditions in extreme temperature environments.

47 OTHER INSTRUMENTATION↗

Improved Instrumentation for Solar Resource Measurements and Forecasting: Cooperative Research and Development Final Report, CRADA Number CRD-09-349

Under this Agreement, NREL will work with Participant to improve the instrumentation and measurement systems available for measuring and monitoring solar radiation elements needed by the electric utilities and solar power system integrators to adequately characterize the spatial and temporal variations of the renewable energy resources. This work includes, but is not limited to, research and development for making cost effective radiometers, solar trackers, and related instrumentation for solar resource measurements and forecasting. Cooperative R&D is proposed in three areas: Improved radiometric systems for cost effective irradiance measurements (direct normal, global, diffuse and plane-of-array); evaluation of innovative disruptive technology approaches for deriving the constituent solar energy components utilizing new fast-response thermopile measurement technologies, coupled with innovative shading geometry and tracker motion control; and low-cost solutions for sky imaging needed for resource forecasting. This work will be conducted at NREL and Participant facilities.

14 SOLAR ENERGY↗

VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

Method validation is the process of evaluating whether an analytical method is acceptable for its intended purpose. For pharmaceutical methods, guidelines from the United States Pharmacopeia (USP), International Conference on Harmonisation (ICH), and the United States Food and Drug Administration (USFDA) provide a framework for performing such valications. In general, methods for regulatory compliance must include studies on specificity, linearity, accuracy, precision, range, detection limit, quantitation limit, and robustness. Elements of these guidelines are readily adapted to the issue of validation for beryllium sampling and analysis. This document provides a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers and books reviewed is given in the Appendix. Available validation documents and guides are listed therein; each has a brief description of application and use. In the referenced sources, there are varying approches to validation and varying descriptions of the valication process at different stages in method development. This discussion focuses on valication and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all referenced documents were published in English.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New portable instrument for the measurement of thermal conductivity in gas process conditions

The development of high temperature gas sensors for the monitoring and determination of thermophysical properties of complex process mixtures at high temperatures faces several problems, related with the materials compatibility, active sensing parts sensitivity, and lifetime. Ceramic/thin metal films based sensors, previously developed for the determination of thermal conductivity of molten materials up to 1200 °C, were redesigned, constructed, and applied for thermal conductivity measuring sensors. Platinum resistance thermometers were also developed using the same technology, to be used in the temperature measurement, which were also constructed and tested. A new data acquisition system for the thermal conductivity sensors, based on a linearization of the transient hot-strip model, including a portable electronic bridge for the measurement of the thermal conductivity in gas process conditions was also developed. The equipment is capable of measuring the thermal conductivity of gaseous phases with an accuracy of 2%-5% up to 840 °C (95% confidence level). The development of sensors up to 1200 °C, present at the core of the combustion chambers, will be done in a near future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating musical instruments

Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Harmonized and high-quality datasets of aerosol optical depth at a US continental site, 1997-2018

Aerosol optical depth (AOD) characterizes the aerosol burden in the atmosphere, while its wavelength dependence is a sign of particle size. Long-term records of wavelength-resolved AOD with high quality and suitable continuity are required for climate change assessment. Typically, climate-related studies use AOD products provided by several, and perhaps different, ground-based instruments. The measurements from these instruments often have different accuracy and temporal resolution. To preserve the advantages of these products (high quality) and to reduce their disadvantages (patchy records), we generate a merged dataset obtained from several instruments in which a nearly-continuous AOD record is found at two wavelengths (500 and 870 nm) with high quality and high temporal resolution (1-min) for a 21-yr period (1997-2018). The combined dataset addresses: (1) varying data quality and resolution mismatch of the individual AOD records, and (2) the uncertainty of the merged AOD and its relevance for user-specified needs. The generated dataset will be beneficial for a wide range of applications including aerosol-radiation interactions and their impact in forcing climate change.

54 ENVIRONMENTAL SCIENCES↗

Design and Instrumentation of a Measurement and Calibration System for an Acoustic Telemetry System

The Juvenile Salmon Acoustic Telemetry System (JSATS) is an active sensing technology developed by Portland District, the U.S. Army Corps of Engineers for detecting and tracking small fish. It is used at hydroelectric projects and in the laboratory for evaluating behavior and survival of juvenile salmonids migrating through the Federal Columbia River Power System to the Pacific Ocean. It provides critical data for salmon protection and development of more “fish-friendly” hydroelectric facilities. The objective of this study was to design and build a measurement and calibration system for evaluating the JSATS component, because the JSATS requires comprehensive acceptance and performance testing in a controlled environment before it is deployed in the field. The system consists of a reference transducer, a water test tank lined with anechoic material, a motion control unit, a reference receiver, a signal conditioner and amplifier unit, a data acquisition board, MATLAB control and analysis interface, and a computer. The fully integrated system has been evaluated successfully at various simulated distances and using different encoded signals at frequencies within the bandwidth of the JSATS transmitter. It provides accurate acoustic mapping capability in a controlled environment and automates the process that allows real-time measurements and evaluation of the piezoelectric transducers, sensors, or the acoustic fields. The measurement and calibration system has been in use since 2009 for acceptance and performance testing of, and further improvements to, the JSATS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Open-path Laser Transmissometer for Atmospheric Extinction Measurements

A transmissometer is an optical instrument which measures transmitted intensity of monochromatic light over a fixed pathlength. Prototype of a simple laser transmissometer has been developed for transmission (or extinction) measurements through suspended absorbers and scatterers in the atmosphere over tens of meters. Instrument consists of a continuous green diode pumped solid state laser, transmission optics, photodiode detectors and A/D data acquisition components. A modulated laser beam is transmitted and subsequently reflected and returned to the unit by a retroreflecting mirror assembly placed several tens of meters away. Results from an open-path field measurement of the instrument are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CHILI – the Chicago Instrument for Laser Ionization – a new tool for isotope measurements in cosmochemistry

We describe CHILI, the Chicago Instrument for Laser Ionization, a new resonance ionization mass spectrometer developed for isotopic analysis at high spatial resolution and high sensitivity of small samples like contemporary interstellar dust grains returned by the Stardust spacecraft. We explain how CHILI addresses the technical challenges associated with such analyses by pushing most technical specifications towards their physical limits. As an initial demonstration, after many years of designing and developing CHILI, we have analyzed presolar silicon carbide grains for their isotopic compositions of strontium, zirconium, and barium. Subsequently, after further technical improvements, we have used CHILI to analyze, for the first time without interference, all stable isotopes of iron and nickel simultaneously in presolar silicon carbide grains. With a special timing scheme for the ionization lasers, we separated iron and nickel isotopes in the time-of-flight spectrum such that the isobaric interference between Fe-58 and Ni-58 was resolved. In-depth discussion of the astrophysical implications of the presolar grain results is deferred to dedicated later publications. Here we focus on the technical aspects of CHILI, its status quo, and further developments necessary to achieve CHILI's ultimate goals, similar to 10 nm lateral resolution and 30-40% useful yield.

Stephan, Thomas (ORCID:0000000163778731)↗

Solid particulate mass and number from ducted fuel injection in an optically accessible diesel engine in skip-fired operation

Ducted fuel injection (DFI) is a new combustion strategy that has been shown to significantly attenuate soot formation in diesel engines. While previous studies have used optical diagnostics and optical filter smoke number methods to show that DFI reduces in-cylinder soot formation and engine-out soot emissions, respectively, this is the first study to measure solid particle number (PN) emissions in addition to particle mass (PM). Furthermore, this study quantitatively evaluates the use of transient particle instruments for measuring particles from skip-fired operation in an optical single cylinder research engine (SCRE). Engine-out PN was measured using an engine exhaust particle sizer following a catalytic stripper, and PM was measured using a photoacoustic analyzer. The study improves on earlier preliminary emissions studies by clearly showing that DFI reduces overall PM by 76%–79% and PN for particles larger than 23 nm by 77% relative to conventional diesel combustion at a 1200-rpm, 13.3-bar gross indicated mean effective pressure operating condition. The degree of engine-out PM reduction with DFI was similar across both particulate measurement instruments used in the work. Through the use of bimodal distribution fitting, DFI was also shown to reduce the geometric mean diameter of accumulation mode particles by 26%, similar to the effects of increased injection pressure in conventional diesel combustion systems. This work clearly shows the significant solid particulate matter reductions enabled by DFI while also demonstrating that engine-out PN can be accurately measured from an optical SCRE operating in a skip-fired mode. Based on these results, it is believed that DFI has the potential to enable fuel savings when implemented in multi-cylinder engines, both by lowering the required frequency of active diesel particulate filter regeneration, and by reducing the backpressure imposed by exhaust filtration systems.

33 ADVANCED PROPULSION SYSTEMS↗

Scanning Mobility Particle Sizer (SMPS)-Aerodynamic Particle Sizer (APS) Merged Size Distribution (mergedsmpsaps) Value-Added Product Report

Aerosol particles influence the Earth’s radiation balance directly by absorbing and scattering light and indirectly by influencing cloud formation, properties, and lifetimes. Measurements of aerosol particle optical properties, mass loading, size distributions, microphysical properties, cloud formation properties, and chemical composition are important for understanding the aerosol life cycle and for validating earth system models that predict these quantities. The Atmospheric Radiation Measurement (ARM) user facility’s Aerosol Observing System (AOS) is a highly instrumented platform designed to house instruments that measure many of these aerosol properties in situ. Currently, ARM operates at least four different instruments that measure a portion of the ambient aerosol size distribution. Most users are interested in the entire size distribution or a portion of the size distribution that extends across the measurement range of multiple instruments. However, merging these distributions is not trivial as the instruments employ different measurement principals and, in most cases, report data as a function of different representations of the aerosol diameter.

54 ENVIRONMENTAL SCIENCES↗