Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mechanical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

SIRTF/IRS cryogenic grating drive mechanism (ARC second positioning at 4 K)

The requirements, design, and test results of a grating drive mechanism for the Infrared Spectrograph (IRS) science instrument on the proposed superfluid helium-cooled Space Infrared Telescope Facility (SIRTF) are described. The IRS grating drive mechanism, tested in the fall of 1989, satisfied all performance requirements in vacuum at 4 K. Measured mechanism performance included: 1.4 arc sec root-mean-square (rms) error positioning resolution; 2.2 arc sec rms position repeatability error, less than 10 millijoules/deg dissipated power; and 170 deg angular range of travel. Mechanisms that precisely position optical elements at very low cryogenic temperatures (at/below 4 K) are vital to the operating success of a number of proposed infrared scientific instruments like those in SIRTF.

Kubitschek, Michael J.↗

Underground coal mine instrumentation and test

The need to evaluate mechanical performance of mine tools and to obtain test performance data from candidate systems dictate that an engineering data recording system be built. Because of the wide range of test parameters which would be evaluated, a general purpose data gathering system was designed and assembled to permit maximum versatility. A primary objective of this program was to provide a specific operating evaluation of a longwall mining machine vibration response under normal operating conditions. A number of mines were visited and a candidate for test evaluation was selected, based upon management cooperation, machine suitability, and mine conditions. Actual mine testing took place in a West Virginia mine.

Burchill, R. F.↗

A Mechanical Device for Illustrating Airplane Stability

An instrument is described which will illustrate completely in a qualitative sense the longitudinal stability characteristics of an airplane. The instrument is primarily of use for the lecture room, but it is hoped that ultimately it will be possible to obtain quantitative results from it.

Norton, F H↗

Design of the PIXIE Cryogenic System

The Primordial Inflation Explorer (PIXIE) is a proposed m1ss1on to study the polarization of the remnant cosmic microwave background with the goal of finding and understanding primordial gravity waves. The instrument has been designed to capture this information across the entire sky by rejecting foreground signals and suppressing systematic error by multiple differencing methods. The instrument operates at a temperature very close to the Cosmic Microwave Background of 2.7 K, while the detectors operate at 0.1 K. The PIXIE cryogenic system provides this in low Earth orbit by making use of 3 subsystems. Lightweight, simply deployed shields provide protection against the Earth and Sun while passively cooling wiring and instrument supports at 150 K. A mechanical cryocooler precools wires and supports at 68, 17, and 4.5 K while its compressors operate at room temperature. And finally two adiabatic demagnetization refrigerators cool the instrument from 4.5 to 2.7 K and cool the detectors to 0.1 K. Staged cooling in this manner allows a thermodynamically efficient use of relatively mature technologies that can be fully demonstrated before flight..

DiPirro, Michael↗

A CW ultrasonic bolt-strain monitor

There exists a need for a relatively inexpensive system for measuring strain in bolts. The torque wrench is one technique for straining bolts which has been widely applied. Unfortunately, friction in the bolt threads and between the nut and the work tend to make such a simple system inaccurate. In practice, a torque wrench is unacceptable for many situations where strain is critical. In this article, an ultrasonic technique is described which can indicate changes in bolt strain to better than one part in 10,000. The technique is based on the one-dimensional propagating-ultrasonic-wave model and uses a new ultrasonic instrument called a Reflection Oscillator Ultrasonic Spectrometer which is a closed-loop feedback marginal-oscillator system that frequency locks the device to the peak of a mechanical resonance in the bolt. The instrument indicates a shift in the bolt resonance frequency due to elongation and changes in velocity of sound due to strain. Data are presented comparing a standard torque wrench to the ultrasonic monitor for different measured stresses on the bolt as well as for different bolt conditions. The strain instrument can be used to monitor changing stresses, to measure material properties and may be applied as a strain gage or load cell.

Heyman, J. S.↗

Pool-Based Tow System for Testing Tethered Hydrokinetic Devices Being Developed to Harvest Energy From Ocean Currents

Abstract The immense potential for ocean current energy harvesting is being actively explored as the push for renewable energy becomes more urgent. This paper demonstrates a tow testing platform built to examine and validate mathematical models related to the performance of tethered, underwater, hydrokinetic devices in development to harvest energy from ocean currents, and presents experimental results illustrating how such a system can be used. The platform has been modularly designed to allow for the testing of various tethered, underwater energy-generation systems, including kite-based systems, coaxial turbines, and duct sails. Previous research on tethered energy-generating systems has primarily been focused on airborne systems. Additionally, the limited experimental research on tethered, underwater energy-generation systems has relied on a rigid rod for mechanical and electrical connections between the test articles and instrumentation. The tow testing platform presented in this paper accomplishes the mechanical and electrical connection through a dual-function tether, featuring internal conductors and an external sheath to support towing loads. The goal of this platform was to enable the emulation of ocean currents, which are largely unidirectional, and to retrofit a regular pool into a cost-effective, adaptable, small-scale tow tank test bed. The capabilities of the system include two-way communication with tethered devices, multiple towing profiles in order to emulate different flow regimes, real-time control, and differential velocities via dual winch operation.

Engineering↗

PULSAUR 2: A sounding rocket project to study pulsating aurora and related phenomena

The second pulsating aurora (PULSAUR 2) rocket was a comprehensively instrumented rocket for the study of the generating mechanisms of pulsating auroras and their related atmospheric and ionospheric effects. It carried instruments to measure electrons and ions over a wide range of energies and pitch angles, optical emissions and X-rays, direct currents and alternating currents, magnetic fields, electron densities and temperatures. The rocket was flown from Andoeya, Norway on 9 February 1994, during good auroral and optical conditions, and reached an altitude of 291.5 km. Coordinated measurements were made from the rocket range by television cameras, photometers, magnetometers, riometers and very low frequency receivers. Ionospheric parameters were measured by the EISCAT radar. The main objectives and performance of the project are discussed, and some of the data obtained are mentioned.

Maaseide, K.↗

Analysis Background & Noise in Stretched Wire Alignment Technique Measurements

The Stretched-Wire Alignment Technique (SWAT) is one method of magnet alignment for linear induction accelerators. The applications of SWAT have been implemented for aligning solenoid magnets on the Scorpius linear induction accelerator which will be sited at the Nevada National Security Site and the Flash X-Ray (FXR) linear induction accelerator at Lawrence Livermore National Laboratory’s Contained Firing Facility. This article describes both systematic (repeatable) and random sources of background and noise as well as practical ways to eliminate or reduce them to acceptable levels. Systematic sources include reflections from wire ends, rapid sag due to ohmic heating of the wire, magnetic materials, and shot rate. Random sources include air currents, vibration of nearby equipment, mechanical stability of test equipment, and the instruments used to measure the wire motion. Mitigations include curve fitting and adaptive noise signal cancellation, and mechanical damping. Finite Element Analysis (FEA) was used to identify and resolve a repeatable wire vibration frequency interfering with the signal resolution. Two stretched wire alignment technique set ups from Sandia National Labs and Lawrence Livermore National Lab have shown background noise sources and ways of mitigating them by either analysis methods or change of mechanical configuration. Conclusions that were drawn included the severe sensitivity of the deflection to even small external interferences of the SWAT wire such that it requires attention to detail in mechanical set up and analysis.

Linear Inductive Accelerator↗

Design and Manufacture of a Highly Reliable, Miniaturized and Low Mass Shutter Mechanism

This paper describes the development, manufacturing and testing of a lightweight shutter mechanism made of titanium for the MERTIS Instrument. MERTIS is a thermal infrared imaging spectrometer onboard ESA's future BepiColombo mission to Mercury. The mechanism is built as a parallelogram arrangement of flexible hinges, actuated by a voice coil. In a first test run, it was shown that the selected EDM processing led to the generation of titanium oxides and an oxygen-enriched surface layer on the substrate (so called alpha-case layer). In the revised version of the shutter, it was possible to manufacture the complex geometry by micro-milling and an adjacent pickling procedure. The adequacy of this approach was verified by lifetime and vibration testing.

Manhart, M.↗

The influence of chemical short-range order on the nanoindentation properties of high-entropy alloys prepared via laser powder bed fusion

Chemical short-range order (CSRO) plays an instrumental role in determining the mechanical properties of high-entropy alloys (HEAs). Current methods for controlling CSRO mainly focus on cast HEAs, which can not solve the problem of grain coarsening caused by homogenization treatments. Laser Powder Bed Fusion (LPBF), which has extremely high cooling rates, can suppress compositional segregation, refine grain structures, and achieve low CSRO. This offers a promising avenue for quantitatively controlling CSRO without the need for homogenization treatments. In this study, we investigate the CSRO of HEAs fabricated via LPBF and elucidate their influence on nanoindentation behavior. The results show that, at the low cooling rate, the average size of CSRO is 0.66 nm and they occupy 2.8% of the cross-sectional area, while at high cooling rate, the corresponding values are 0.92 nm and 9.9%, respectively, both of which are significantly smaller than those of cast HEAs. Furthermore, by analyzing samples with different CSROs, we observe that the hardness increases and then decreases with the increase of CSRO, primarily due to the preferential formation of dislocations in regions enriched with Cr-Mn-Ni. With the improvement of CSRO, both the size and quantity of Cr-Mn-Ni rich region gradually increased; subsequently, as multiple Cr-Mn-Ni rich regions tend to merge into one during the CSRO improvement, the size of the Cr-Mn-Ni rich region continued to increase while the quantity gradually decreased; when the size of the Cr-Mn-Ni rich region is moderate and widely dispersed, the dislocation density is higher with much more uniform distributions, which favorably improves nanoindentation hardness.

36 MATERIALS SCIENCE↗

Upgrades to the ion cyclotron emission diagnostic on the DIII-D tokamak

The ion cyclotron emission diagnostic on the DIII-D tokamak comprises seven single-turn loops that measure high-frequency (1–100 MHz) magnetic field fluctuations that are often excited by energetic particles in the plasma. The raw voltage signals induced in the loops in response to these fluctuations travel through a series of cables, isolation transformer DC blocks, low-pass filters, and finally a digitizer before being analyzed in frequency space. The diagnostic has been recently upgraded, most notably to include four additional graphite tile loops and a new eight-channel digitizer. The previous three loops are all on the low-field side of the tokamak. The measurement capabilities of the system have been expanded by the addition of a new horizontally oriented loop on the low-field side, an additional toroidal loop on the low-field side, and two toroidal loops on the high-field side. These loops will be used to provide approximate mode polarization, improved toroidal mode number calculations, and information on modes in inward-shifted plasmas, respectively.

47 OTHER INSTRUMENTATION↗

Complete Stokes vector analysis with a compact, portable rotating waveplate polarimeter

Accurate calibration of polarization dependent optical elements is often necessary in optical experiments. A versatile polarimeter device to measure the polarization state of light is a valuable tool in these experiments. Here we report a rotating waveplate-based polarimeter capable of complete Stokes vector analysis of collimated light. Calibration of the device allows accurate measurements over a range of wavelengths, with a bandwidth of >30 nm in this implementation. A photo-interrupter trigger system supplies the phase information necessary for full determination of the Stokes vector. An Arduino microcontroller performs rapid analysis and displays the results on a liquid crystal display. The polarimeter is compact and can be placed anywhere on an optical table on a single standard post. The components to construct the device are only a fraction of the cost of commercially available devices while the accuracy and precision of the measurements are of the same order of magnitude.

47 OTHER INSTRUMENTATION↗

Raster Thomson scattering in large-scale laser plasmas produced at high repetition rate

We present optical Thomson scattering measurements of electron density and temperature in a large-scale (~2 cm) exploding laser plasma produced by irradiating a solid target with a high energy (5-10 J) laser pulse at high repetition rate (1 Hz). The Thomson scattering diagnostic matches this high repetition rate. Unlike previous work performed in single shots at much higher energies, the instrument allows point measurements anywhere inside the plasma by automatically translating the scattering volume using motorized stages as the experiment is repeated at 1 Hz. Measured densities around 4×10 16 cm -3 and temperatures around 7 eV result in a scattering parameter near unity, depending on the distance from the target. The measured spectra show the transition from collective scattering close to the target to non-collective scattering at larger distances. Densities obtained by fitting the weakly collective spectra agree to within 10% with an irradiance calibration performed via Raman scattering in nitrogen.

47 OTHER INSTRUMENTATION↗

Development of deflector mode for spin-resolved time-of-flight photoemission spectroscopy

Spin- and angle-resolved photoemission spectroscopy (“spin-ARPES”) is a powerful technique for probing the spin degree-of-freedom in materials with nontrivial topology, magnetism, and strong correlations. Spin-ARPES faces severe experimental challenges compared to conventional ARPES attributed to the dramatically lower efficiency of its detection mechanism, making it crucial for instrumentation developments that improve the overall performance of the technique. Here in this paper, we demonstrate the functionality of our spin-ARPES setup based on time-of-flight spectroscopy and introduce our recent development of an electrostatic deflector mode to map out spin-resolved band structures without sample rotation. We demonstrate the functionality by presenting the spin-resolved spectra of the topological insulator Bi2Te3 and describe in detail the spectrum calibrations based on numerical simulations. By implementing the deflector mode, we minimize the need for sample rotation during measurements, hence improving the overall efficiency of experiments on small or inhomogeneous samples.

47 OTHER INSTRUMENTATION↗

Introduction to the Special Issue on Software Tools for Quantum Computing: Part 1

Quantum computing is emerging as a remarkable technology that offers the possibility of achieving major scientific breakthroughs in many areas. Here, by leveraging the unique features of quantum mechanics, quantum computers may be instrumental in advancing many areas, including science, energy, defense, medicine, and finance. This includes solving complex problems whose solution lies well beyond the capacity of contemporary and even future supercomputers that are based on conventional computing technologies. As a foundation for future generations of computing and information processing, quantum computing represents an exciting area for developing new ideas in computer science and computational engineering.

97 MATHEMATICS AND COMPUTING↗

Introduction to the Special Issue on Software Tools for Quantum Computing: Part 2

Quantum computing is emerging as a remarkable technology that offers the possibility of achieving major scientific breakthroughs in many areas. By leveraging the unique features of quantum mechanics, quantum computers may be instrumental in advancing many areas, including science, energy, defense, medicine, and finance. This includes solving complex problems whose solution lies well beyond the capacity of contemporary and even future supercomputers that are based on conventional computing technologies. As a foundation for future generations of computing and information processing, quantum computing represents an exciting area for developing new ideas in computer science and computational engineering.

97 MATHEMATICS AND COMPUTING↗