Search NASA⌕ Search

SEARCH · Search NASA

Results for “Medical Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record↗

Phosphor Scanner For Imaging X-Ray Diffraction

Improved optoelectronic scanning apparatus generates digitized image of x-ray image recorded in phosphor. Scanning fiber-optic probe supplies laser light stimulating luminescence in areas of phosphor exposed to x rays. Luminescence passes through probe and fiber to integrating sphere and photomultiplier. Sensitivity and resolution exceed previously available scanners. Intended for use in x-ray crystallography, medical radiography, and molecular biology.

Carter, Daniel C.↗

Ocular Coherence Tomography in the Evaluation of Anterior Eye Injuries in Space Flight

While Ocular Coherence Tomography (OCT) is not a first-line modality to evaluate anterior eye structures terrestrially, it is a resource already available on the International Space Station (ISS) that can be used in medical contingencies that involve the anterior eye. With remote guidance and subject matter expert (SME) support from the ground, a minimally trained crewmember can now use OCT to evaluate anterior eye pathologies on orbit. OCT utilizes low-coherence interferometry to produce detailed cross-sectional and 3D images of the eye in real time. Terrestrially, it has been used to evaluate macular pathologies and glaucoma. Since 2013, OCT has been used onboard the ISS as one part of a suite of hardware to evaluate the Visual Impairment/Intracranial Pressure risk faced by astronauts, specifically assessing changes in the retina and choroid during space flight. The Anterior Segment Module (ASM), an add-on lens, was also flown for research studies, providing an opportunity to evaluate the anterior eye in real time if clinically indicated. Anterior eye pathologies that could be evaluated using OCT were identified. These included corneal abrasions and ulcers, scleritis, and acute angle closure glaucoma. A remote guider script was written to provide ground specialists with step-by-step instructions to guide ISS crewmembers, who do not get trained on the ASM, to evaluate the anterior eye. The instructions were tested on novice subjects and/or operators, whose feedback was incorporated iteratively. The final remote guider script was reviewed by SME optometrists and NASA flight surgeons. The novel application of OCT technology to space flight allows for the acquisition of objective data to diagnose anterior eye pathologies when other modalities are not available. This demonstrates the versatility of OCT and highlights the advantages of using existing hardware and remote guidance skills to expand clinical capabilities in space flight.

Fer, Dan M.↗

Protein Innovations Advance Drug Treatments, Skin Care

Dan Carter carefully layered the sheets of tracing paper on the light box. On each sheet were renderings of the atomic components of an essential human protein, one whose structure had long been a mystery. With each layer Carter laid down, a never-before-seen image became clearer. Carter joined NASA s Marshall Space Flight Center in 1985 and began exploring processes of protein crystal growth in space. By bouncing intense X-rays off the crystals, researchers can determine the electron densities around the thousands of atoms forming the protein molecules, unveiling their atomic structures. Cultivating crystals of sufficient quality on Earth was problematic; the microgravity conditions of space were far more accommodating. At the time, only a few hundred protein structures had been mapped, and the methods were time consuming and tedious. Carter hoped his work would help reveal the structure of human serum albumin, a major protein in the human circulatory system responsible for ferrying numerous small molecules in the blood. More was at stake than scientific curiosity. Albumin has a high affinity for most of the world s pharmaceuticals, Carter explains, and its interaction with drugs can change their safety and efficacy. When a medication enters the bloodstream a cancer chemotherapy drug, for example a majority of it can bind with albumin, leaving only a small percentage active for treatment. How a drug interacts with albumin can influence considerations like the necessary effective dosage, playing a significant role in the design and application of therapeutic measures. In spite of numerous difficulties, including having no access to microgravity following the 1986 Space Shuttle Challenger disaster, the image Carter had hoped to see was finally clarifying. In 1988, his lab had acquired specialized X-ray and detection equipment a tipping point. Carter and his colleagues began to piece together albumin s portrait, the formation of its electron densities coalescing on the sheets of tracing paper he arranged on the light box. While space-grown crystals were ultimately not involved in the achievement, a year later, Carter says, we were on the cover of Science magazine, having determined the atomic structure of albumin.

Source record↗

The low intensity X-ray imaging scope /Lixiscope/

A fully portable, small-format X-ray imaging system, Lixiscope (low intensity X-ray imaging scope) is described. In the prototype, which has been built to demonstrate the feasibility of the Lixiscope concept, only well-developed and available components have been used. Consideration is given to the principles of operation of the device, some of its performance characteristics as well as possible dental, medical and industrial applications.

Yin, L. I.↗

Hyperspectral Systems Increase Imaging Capabilities

In 1983, NASA started developing hyperspectral systems to image in the ultraviolet and infrared wavelengths. In 2001, the first on-orbit hyperspectral imager, Hyperion, was launched aboard the Earth Observing-1 spacecraft. Based on the hyperspectral imaging sensors used in Earth observation satellites, Stennis Space Center engineers and Institute for Technology Development researchers collaborated on a new design that was smaller and used an improved scanner. Featured in Spinoff 2007, the technology is now exclusively licensed by Themis Vision Systems LLC, of Richmond, Virginia, and is widely used in medical and life sciences, defense and security, forensics, and microscopy.

Source record↗

Virtual Guidance Ultrasound: A Tool to Obtain Diagnostic Ultrasound for Remote Environments

Astronauts currently acquire ultrasound images on the International Space Station with the assistance of real-time remote guidance from an ultrasound expert in Mission Control. Remote guidance will not be feasible when significant communication delays exist during exploration missions beyond low-Earth orbit. For example, there may be as much as a 20- minute delay in communications between the Earth and Mars. Virtual-guidance, a pre-recorded audio-visual tutorial viewed in real-time, is a viable modality for minimally trained scanners to obtain diagnostically-adequate images of clinically relevant anatomical structures in an autonomous manner. METHODS: Inexperienced ultrasound operators were recruited to perform carotid artery (n = 10) and ophthalmic (n = 9) ultrasound examinations using virtual guidance as their only instructional tool. In the carotid group, each each untrained operator acquired two-dimensional, pulsed, and color Doppler of the carotid artery. In the ophthalmic group, operators acquired representative images of the anterior chamber of the eye, retina, optic nerve, and nerve sheath. Ultrasound image quality was evaluated by independent imaging experts. RESULTS: Eight of the 10 carotid studies were judged to be diagnostically adequate. With one exception the quality of all the ophthalmic images were adequate to excellent. CONCLUSION: Diagnostically-adequate carotid and ophthalmic ultrasound examinations can be obtained by untrained operators with instruction only from an audio/video tutorial viewed in real time while scanning. This form of quick-response-guidance, can be developed for other ultrasound examinations, represents an opportunity to acquire important medical and scientific information for NASA flight surgeons and researchers when trained medical personnel are not present. Further, virtual guidance will allow untrained personnel to autonomously obtain important medical information in remote locations on Earth where communication is difficult or absent.

Caine,Timothy L.↗

Medical tomograph system using ultrasonic transmission

Ultrasonic energy transmission in rectilinear array scanning patterns of soft tissue provides projection density values of the tissue which are recorded as a function of scanning position and angular relationship, .theta., of the subject with a fixed coordinate system. A plurality of rectilinear scan arrays in the same plane for different angular relationships .theta..sub.1 . . . .theta..sub.n thus recorded are superimposed. The superimposition of intensity values thus yields a tomographic image of an internal section of the tissue in the scanning plane.

Heyser, Richard C.↗

Image Analysis via Fuzzy-Reasoning Approach: Prototype Applications at NASA

A set of imaging techniques based on Fuzzy Reasoning (FR) approach was built for NASA at Kennedy Space Center (KSC) to perform complex real-time visual-related safety prototype tasks, such as detection and tracking of moving Foreign Objects Debris (FOD) during the NASA Space Shuttle liftoff and visual anomaly detection on slidewires used in the emergency egress system for Space Shuttle at the launch pad. The system has also proved its prospective in enhancing X-ray images used to screen hard-covered items leading to a better visualization. The system capability was used as well during the imaging analysis of the Space Shuttle Columbia accident. These FR-based imaging techniques include novel proprietary adaptive image segmentation, image edge extraction, and image enhancement. Probabilistic Neural Network (PNN) scheme available from NeuroShell(TM) Classifier and optimized via Genetic Algorithm (GA) was also used along with this set of novel imaging techniques to add powerful learning and image classification capabilities. Prototype applications built using these techniques have received NASA Space Awards, including a Board Action Award, and are currently being filed for patents by NASA; they are being offered for commercialization through the Research Triangle Institute (RTI), an internationally recognized corporation in scientific research and technology development. Companies from different fields, including security, medical, text digitalization, and aerospace, are currently in the process of licensing these technologies from NASA.

Dominguez, Jesus A.↗

Optically Inaccessible Flow Visualization using Positron Emission Tomography

Flow visualization is a powerful tool for characterizing fluid dynamics within engineering systems that utilize fluid working media. Recent advances in Positron Emission Tomography (PET) have enhanced its ability to extend beyond the medical field, and offer an alternate vantage point in visualizing optically inaccessible fluid distributions and flow fields within the aerospace field. In light of this prospect an investigation has ensued to parametrically bound the flows that can be sufficiently resolved using current PET technology. Results from an initial series of experiments and analyses performed at the Positron Imaging Centre (PIC) located at the University of Birmingham, UK, will be presented. Discussion will also cover preliminary, on-going, activities associated with assessing the utility of PET technology in zero-gravity propellant gauging, ionization efficiency characterization in electric propulsion devices, and broader industrial applications.

PET↗

Autonomous Medical Officer Support (AMOS) ISS Technology Demonstration: Enabling Earth-Independnt Procedure Guidance

Successful performance of medical procedures during missions beyond low Earth orbit requires novel solutions to replace real-time support from the ground since the communication delay will be longer as the crew travels farther from Earth. The Autonomous Medical Officer Support software Technology Demonstration project (AMOS Tech Demo) on the International Space Station (ISS) evaluates a novel software tool that shifts the emphasis from preflight training and real-time guidance (current ISS paradigm) to in-flight just-in-time (JIT) instruction (a new paradigm for crew medical autonomy). The AMOS platform introduces a novel, streamlined, skill-management archetype for exploration missions; the current AMOS version features comprehensive training and guidance modules for urinary bladder and kidney ultrasound examinations. The primary goal of the AMOS Tech Demo was to confirm telemedical proof-of-concept through initial use of the platform for autonomous imaging activities in an operational setting. Success metrics encompassed 1) successful software deployment, 2) collection of click tracking data, and 3) recording of ultrasound images. Additional aims included collecting crew feedback on a) AMOS implementation, and b) integrated training and procedure support concepts, as well as c) evaluation of AMOS use in an operational setting.

D. Ebert↗

Medical ultrasonic tomographic system

An electro-mechanical scanning assembly was designed and fabricated for the purpose of generating an ultrasound tomogram. A low cost modality was demonstrated in which analog instrumentation methods formed a tomogram on photographic film. Successful tomogram reconstructions were obtained on in vitro test objects by using the attenuation of the fist path ultrasound signal as it passed through the test object. The nearly half century tomographic methods of X-ray analysis were verified as being useful for ultrasound imaging.

Heyser, R. C.↗

Measuring the metastatic potential of cancer cells

Cancer cells must secrete proteolytic enzymes to invade adjacent tissues and migrate to a new metastatic site. Urokinase (uPA) is a key enzyme related to metastasis in cancers of the lung, colon, gastric, uterine, breast, brain, and malignant melanoma. A NASA technology utilization project has combined fluorescence microscopy, image analysis, and flow cytometry, using fluorescent dyes, and urokinase-specific antibodies to measure uPA and abnormal DNA levels (related to cancer cell proliferation) inside the cancer cells. The project is focused on developing quantitative measurements to determine if a patient's tumor cells are actively metastasizing. If a significant number of tumor cells contain large amounts of uPA (esp. membrane-bound) then the post-surgical chemotherapy or radiotherapy can be targeted for metastatic cells that have already left the primary tumor. These analytical methods have been applied to a retrospective study of biopsy tissues from 150 node negative, stage 1 breast cancer patients. Cytopathology and image analysis has shown that uPA is present in high levels in many breast cancer cells, but not found in normal breast. Significant amounts of uPA also have been measured in glioma cell lines cultured from brain tumors. Commercial applications include new diagnostic tests for metastatic cells, in different cancers, which are being developed with a company that provides a medical testing service using flow cytometry for DNA analysis and hormone receptors on tumor cells from patient biopsies. This research also may provide the basis for developing a new 'magic bullet' treatment against metastasis using chemotherapeutic drugs or radioisotopes attached to urokinase-specific monoclonal antibodies that will only bind to metastatic cells.

Morrison, Dennis R.↗

The Effects of Long Duration Bed Rest on Functional Mobility and Balance: Relationship to Resting State Motor Cortex Connectivity

NASA offers researchers from a variety of backgrounds the opportunity to study bed rest as an experimental analog for space flight. Extended exposure to a head-down tilt position during long duration bed rest can resemble many of the effects of a low-gravity environment such as reduced sensory inputs, body unloading and increased cephalic fluid distribution. The aim of our study is to a) identify changes in brain function that occur with prolonged bed rest and characterize their recovery time course; b) assess whether and how these changes impact behavioral and neurocognitive performance. Thus far, we completed data collection from six participants that include task based and resting state fMRI. The data have been acquired through the bed rest facility located at the University of Texas Medical Branch (Galveston, TX). Subjects remained in bed with their heads tilted down 6 degrees below their feet for 70 consecutive days. Behavioral measures and neuroimaging assessments were obtained at seven time points: a) 7 and 12 days before bed rest; b) 7, 30, and 65 days during bed rest; and c) 7 and 12 days after bed rest. Functional connectivity magnetic resonance imaging (FcMRI) analysis was performed to assess the connectivity of motor cortex in and out of bed rest. We found a decrease in motor cortex connectivity with vestibular cortex and the cerebellum from pre bed rest to in bed rest. We also used a battery of behavioral measures including the functional mobility test and computerized dynamic posturography collected before and after bed rest. We will report the preliminary results of analyses relating brain and behavior changes. Furthermore, we will also report the preliminary results of a spatial working memory task and vestibular stimulation during in and out of bed rest.

Erdeniz, B.↗

MEDSAT - A remote sensing satellite for malaria early warning and control

A remote sensing, medical satellite (MEDSAT) aids in the control of carrier (vector) borne disease. The prototype design is a light satellite to test for control of malaria. The design features a 340-kg satellite with visual/IR and SAR sensors in a low inclination orbit observing a number of worldwide test sites. The approach is to use four-band visual/IR and dual-polarized L-band SAR images obtained from MEDSAT in concert with in-situ data to estimate the temporal and spatial variations of malaria risk. This allows public health resources to focus on the most vulnerable areas at the appropriate time. It is concluded that a light-satellite design for a MEDSAT satellite with a Pegasus launch is feasible.

Vesecky, John↗

An IDEA of What's in the Air

The Automatic Particle Fallout Monitor (APFM) is an automated instrument that assesses real-time particle contamination levels in a facility by directly imaging, sizing, and counting contamination particles. It allows personnel to respond to particle contamination before it becomes a major problem. For NASA, the APFM improves the ability to mitigate, avoid, and explain mission-compromising incidents of contamination occurring during payload processing, launch vehicle ground processing, and potentially, during flight operations. Commercial applications are in semiconductor processing and electronics fabrication, as well as aerospace, aeronautical, and medical industries. The product could also be used to measure the air quality of hotels, apartment complexes, and corporate buildings. IDEA sold and delivered its first four units to the United Space Alliance for the Space Shuttle Program at Kennedy. NASA used the APFM in the Kennedy Space Station Processing Facility to monitor contamination levels during the assembly of International Space Station components.

Source record↗

An overview of the space medicine program and development of the Health Maintenance Facility for Space Station

Because the prolonged stay on board the Space Station will increase the risk of possible inflight medical problems from that on Skylab missions, the Health Maintenance Facility (HMF) planned for the Space Station is much more sophisticated than the small clinics of the Skylab missions. The development of the HMF is directed by the consideration of three primary factors: prevention, diagnosis, and treatment of injuries and illnesses that may occur in flight. The major components of the HMF include the clinical laboratory, pharmacy, imaging system, critical-care system, patient-restraint system, data-management system, exercise system, surgical system, electrophysiologic-monitoring system, introvenous-fluid system, dental system, and hyperbaric-treatment-support system.

Pool, Sam Lee↗

Surgical Capabilities for Exploration and Colonization Space Flight - An Exploration Symposium

Surgical capabilities in human space flight, whether on a space-based platform in low Earth orbit or on a long duration planetary exploration mission, will be challenging to conduct for a variety of reasons, some of which will be ameliorated by training, technology, and pre-flight planning. Nevertheless, inherent risks and challenges remain. Early space missions did not have any surgical capability. It was not until NASA's Skylab mission that serious consideration was given to this fundamental medical care capability. Over the past 30 years, subject matter experts have been brought together for discussion on the myriad of challenges and opportunities in this endeavor. The last such meeting was held in 2005 at the NASA Johnson Space Center. As we continue to move forward with human space flight activities for the International Space Station and beyond, the capabilities of information technology, robotics, sensors and imaging have rapidly changed since the last gathering of expertise. In December 2015, through sponsorship of the National Space Biomedical Research Institute (NSBRI), a diverse group of individuals from government, academia, and industry representing three countries gathered at the NSBRI Space 4 Biomedicine facility in Houston, TX. This two day symposia included comprehensive sessions that addressed the challenges that we all face in developing, deploying, and utilizing surgical care capabilities in all human space missions, regardless of mission duration or profile. The symposium benefited from the knowledge and experience of three seasoned NASA physician astronauts, Drs. Jay Buckey, Thomas Marshburn, and Lee Morin. At the end of the first day, the assembled group heard from the crew members about their experiences and their ideas. It is clear that the discussion of surgical capabilities is part of the larger discussion of consideration of advanced healthcare, including critical care, on exploration space missions. This report represents the culmination of the symposium, capturing knowledge, experience, conceptual dialogue, and a narrative that can be used in supporting the development of future programs and potential policy. Each of the presentations that were provided by the guest speakers is included in the appendices. Those presentations that are not included were due to sensitivity of the material or at the request of the speaker. In addition, each speaker was offered an opportunity to provide comments in a 'lightning round' format. All of these comments and speaker abstracts also appear in the appendices. At the conclusion of the second day, a discussion was held that reviewed the priorities that perhaps add value to decision makers. These are also summarized. This report will serve as the final product of this symposium. Additional material may be produced for the peer-reviewed literature.

Doarn, Charles R.↗