Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microfluidic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Single cell swimming dynamics of Listeria monocytogenes using a nanoporous microfluidic platform

Listeria monocytogenes remains a significant foodborne pathogen due to its virulence and ability to become established in food processing facilities. The pathogen is characterized by its ability to grow over a wide temperature range and withstand a broad range of stresses. The following reports on the chemotaxis and motility of the L. monocytogenes when exposed to relatively small concentrations of acetic acid. Using the developed nanoporous microfluidic device to precisely modulate the cellular environment, we exposed the individual Listeria cells to acetic acid and, in real time and with high resolution, observed how the cells reacted to the change in their surroundings. Our results showed that concentrations of acetic acid below 10 mM had very little, if any, effect on the motility. However, when exposed to 100 mM acetic acid, the cells exhibited a sharp drop in velocity and displayed a more random pattern of motion. These results indicate that at appropriate concentrations, acetic acid has the ability to disable the flagellum of the cells, thus impairing their motility. This drop in motility has numerous effects on the cell; its main effects being the obstruction of the cell's ability to properly form biofilms and a reduction in the overall infectivity of the cells. Since these characteristics are especially useful in controlling the proliferation of L. monocytogenes, acetic acid shows potential for application in the food industry as an active compound in designing a food packaging environment and as an antimicrobial agent.

Wright, Evan↗

Single microbe trap and release in sub-microfluidics

Lab-on-a-chip systems have substantially impacted the way life-sciences are explored; life on earth, however, comprises mostly of microbes, which due to their sub-micron dimensions and high mobility are more challenging to dynamically manipulate on-a-chip. To address this challenge, we developed a high resolution microfluidic system (submicrofluidics) fabricated by direct electron beam lithography that is capable of trapping single microbes and releasing them upon demand. The fabrication method enabled the integration of sub-micron indentations (400 nm) with millimetre-scale fluidic channels rapidly in a single processing step. The larger channels deliver the cell suspension and reagents, while the sub-micron indentations immobilize the cells by locally increasing the hydrodynamic resistance. By volume exclusion, single cell trapping was possible in this system without any surface treatment. By increasing the flow rate, the microbes overcome the trap barrier and pass through the narrow indentation without undergoing lysis with kinetics that depend on their size. The fabrication method and its performance are described, along with microbial characterisations using E. coli.

59 BASIC BIOLOGICAL SCIENCES↗

Multilayer Microfluidic Devices Created From A Single Photomask

The time and expense associated with high quality photomask production can discourage the creation of multilayer microfluidic devices, as each layer currently requires a separate photomask. Here we describe an approach in which multilayer microfabricated devices can be created from a single photomask. The separate layers and their corresponding alignment marks are arranged in separate halves of the mask for two layer devices or quadrants for four layer devices. Selective exposure of the photomask features and rotation of the device substrate between exposures result in multiple copies of the devices on each wafer. Subsequent layers are aligned to patterned features on the substrate with the same alignment accuracy as when multiple photomasks are used. We demonstrate this approach for fabricating devices employing multilayer soft lithography (MSL) for pneumatic valving. MSL devices containing as many as 5 layers (4 aligned fluidic layers plus a manually aligned control layer) were successfully created using this approach. Device design is also modularized, enabling the presence or absence of features as well as channel heights to be selected independently from one another. The use of a single photomask to create multilayer devices results in a dramatic savings of time and/or money required to advance from device design to completed prototype.

47 OTHER INSTRUMENTATION↗

A solvent replenishment solution for managing evaporation of biochemical reactions in air-matrix digital microfluidics devices

Digital microfluidics (DMF) is a powerful technique for sample preparation and analysis for a broad range of biological and chemical applications. In many cases, it is desirable to carry out DMF on an open surface, such that the matrix surrounding the droplets is ambient air. However, the utility of the air-matrix DMF format has been severely limited by problems with droplet evaporation, especially when the droplet-based biochemical reactions require high temperatures for long periods of time. We present a simple solution for managing evaporation in air-matrix DMF: just-in-time replenishment of the reaction volume using droplets of solvent. We demonstrate that this solution enables DMF-mediated execution of several different biochemical reactions (RNA fragmentation, first-strand cDNA synthesis, and PCR) over a range of temperatures (4–95 °C) and incubation times (up to 1 h or more) without use of oil, humidifying chambers, or off-chip heating modules. Reaction volumes and temperatures were maintained roughly constant over the course of each experiment, such that the reaction kinetics and products generated by the air-matrix DMF device were comparable to those of conventional benchscale reactions. As a result, this simple yet effective solution for evaporation management is an important advance in developing air-matrix DMF for a wide variety of new, high-impact applications, particularly in the biomedical sciences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid and continuous magnetic separation in droplet microfluidic devices

Here, we present a droplet microfluidic method to extract molecules of interest from a droplet in a rapid and continuous fashion. We accomplish this by first marginalizing functionalized super-paramagnetic beads within the droplet using a magnetic field, and then splitting the droplet into one droplet containing the majority of magnetic beads and one droplet containing the minority fraction. We quantitatively analysed the factors which affect the efficiency of marginalization and droplet splitting to optimize the enrichment of magnetic beads. We first characterized the interplay between the droplet velocity and the strength of the magnetic field and its effect on marginalization. We found that marginalization is optimal at the midline of the magnet and that marginalization is a good predictor of bead enrichment through splitting at low to moderate droplet velocities. Finally, we focused our efforts on manipulating the splitting profile to improve the enrichment provided by asymmetric splitting. We designed asymmetric splitting forks that employ capillary effects to preferentially extract the bead-rich regions of the droplets. Our strategy represents a framework to optimize magnetic bead enrichment methods tailored to the requirements of specific droplet-based applications. We anticipate that our separation technology is well suited for applications in single-cell genomics and proteomics. In particular, our method could be used to separate mRNA bound to poly-dT functionalized magnetic microparticles from single cell lysates to prepare single-cell cDNA libraries.

60 APPLIED LIFE SCIENCES↗

Ultrasensitive multi-species detection of CRISPR-Cas9 by a portable centrifugal microfluidic platform

The discovery of the RNA-guided DNA nuclease CRISPR-Cas9 has enabled the targeted editing of genomes from diverse organisms, but the permanent and inheritable nature of genome modification also poses immense risks. The potential for accidental exposure, malicious use, or undesirable persistence of Cas9 therapeutics and off-target genome effects highlight the need for detection assays. Here we report a centrifugal microfluidic platform for the measurement of both Cas9 protein levels and nuclease activity. Because Cas9 from many bacterial species have been adapted for biotechnology applications, we developed the capability to detect Cas9 from the widely-used S. pyogenes, as well as S. aureus, N. meningitidis, and S. thermophilus using commercially-available antibodies. Further, we show that the phage-derived anti-CRISPR protein AcrIIC1, which binds to Cas9 from several species, can be used as a capture reagent to broaden the species range of detection. Finally, as genome modification generally requires Cas9 nuclease activity, a fluorescence-based sedimentation nuclease assay was also incorporated to allow the sensitive and simultaneous measurement of both Cas9 protein and activity in a single biological sample.

59 BASIC BIOLOGICAL SCIENCES↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗

Polymer-based microfluidic device for on-chip counter-diffusive crystallization and in situ X-ray crystallography at room temperature

Proteins are long chains of amino acid residues that perform a myriad of functions in living organisms, including enzymatic reactions, signalling, and maintaining structural integrity. Protein function is determined directly by the protein structure. X-ray crystallography is the primary technique for determining the 3D structure of proteins, and facilitates understanding the effects of protein structure on function. The first step towards structure determination is crystallizing the protein of interest. We have developed a centrifugally-actuated microfluidic device that incorporates the fluid handling and metering necessary for protein crystallization. Liquid handling takes advantage of surface forces to control fluid flow and enable metering, without the need for any fluidic or pump connections. Our approach requires only the simple steps of pipetting the crystallization reagents into the device followed by either spinning or shaking to set up counter-diffusive protein crystallization trials. The use of thin, UV-curable polymers with a high level of X-ray transparency allows for in situ X-ray crystallography, eliminating the manual handling of fragile protein crystals and streamlining the process of protein structure analysis. We demonstrate the utility of our device using hen egg white lysozyme as a model system, followed by the crystallization and in situ, room temperature structural analysis of the hub domain of calcium–calmodulin dependent kinase II (CaMKIIβ).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Control of liquid crystals combining surface acoustic waves, nematic flows, and microfluidic confinement

The optical properties of liquid crystals serve as the basis for display, diagnostic, and sensing technologies. Such properties are generally controlled by relying on electric fields. In this work, we investigate the effects of microfluidic flows and acoustic fields on the molecular orientation and the corresponding optical response of nematic liquid crystals. Several previously unknown structures are identified, which are rationalized in terms of a state diagram as a function of the strengths of the flow and the acoustic field. The new structures are interpreted by relying on calculations with a free energy functional expressed in terms of the tensorial order parameter, using continuum theory simulations in the Landau-de Gennes framework. Taken together, the findings presented here offer promise for the development of new systems based on combinations of sound, flow, and confinement.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optimizing microfluidic flow cell geometry for in situ resonant soft X-ray characterization of molecular nanostructures

Liquid-phase resonant soft X-ray scattering (LP-RSoXS) is an emerging label-free technique to probe chemically resolved nanostructures of molecular or hybrid materials in liquid environments. Still, quantitative analysis is hindered by the pressure-induced deformation of thin silicon nitride (SiN) membranes used as windows in microfluidic flow cells, which attenuates the signal in nonlinear ways, making experimental optimization difficult. Here, in this work, we directly characterize this deformation under experimental conditions for a variety of cell configurations. We use this to develop a predictive model that combines transmission effects of SiN bowing, incident X-ray beam profiles, and material-dependent resonant scattering cross sections to simulate the effective scattering intensity at the detector across the carbon K-edge. Maps of the total signal across the flow cell window reveal that increasing the window width and polymer concentration shifts the anisotropic intensity distributions from the center toward the edges of the window. It was determined that an optimal SiN thickness of 50 nm, with a window aperture of 104 μm, maximizes the total signal for typical solute concentrations and energies across the carbon K-edge. Our results overturn the assumption that corner regions dominate the scattering signal, offering explicit design guidelines for maximizing LP-RSoXS signals and significantly advancing the quantitative application of this technique to the characterization of molecular and hybrid nanostructured materials in liquids.

Grabner, Devin [Washington State Univ., Pullman, W↗

Microfluidic pumps employing surface acoustic waves generated in ZnO thin films

ZnO thin film based surface acoustic wave (SAW) devices have been utilized to fabricate microfluidic pumps. The SAW devices were fabricated on nanocrystalline ZnO piezoelectric thin films deposited on Si substrates using rf magnetron sputtering and use a Sezawa wave mode for effective droplet motion. The as-deposited ZnO surface is hydrophilic, with a water contact angle of {approx}75 deg., which prevents droplet pumping. Therefore, the ZnO surface was coated using a self-assembled monolayer of octadecyltrichlorosilane which forms a hydrophobic surface with a water contact angle of {approx}110 deg. Liquid droplets between 0.5 and 1 {mu}l in volume were successfully pumped on the hydrophobic ZnO surface at velocities up to 1 cm s{sup -1}. Under acoustic pressure, the water droplet on an hydrophilic surface becomes deformed, and the asymmetry in the contact angle at the trailing and leading edges allow the force acting upon the droplet to be calculated. These forces, which increase with input voltage above a threshold level, are found to be in the range of {approx}100 {mu}N. A pulsed rf signal has also been used to demonstrate precision manipulation of the liquid droplets. Furthermore, a SAW device structure is demonstrated in which the ZnO piezoelectric only exists under the input and output transducers. This structure still permits pumping, while avoiding direct contact between the piezoelectric material and the fluid. This is of particular importance for biological laboratory-on-a-chip applications.

36 MATERIALS SCIENCE↗

Natural discharge after pulse and cooperative electrodes to enhance droplet velocity in digital microfluidics

Digital Microfluidics (DMF) is a promising technology for biological/chemical micro-reactions due to its distinct droplet manageability via electronic automation, but the limited velocity of droplet transportation has hindered DMF from utilization in high throughput applications. In this paper, by adaptively fitting the actuation voltages to the dynamic motions of droplet movement under real-time feedback monitoring, two control-engaged electrode-driving techniques: Natural Discharge after Pulse (NDAP) and Cooperative Electrodes (CE) are proposed. They together lead to, for the first time, enhanced droplet velocity with lower root mean square voltage value.

36 MATERIALS SCIENCE↗