Search NASA⌕ Search

SEARCH · Search NASA

Results for “Morris method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Creep-rupture of polymer-matrix composites

An accelerated characterization method for resin matrix composites is reviewed. Methods for determining modulus and strength master curves are given. Creep rupture analytical models are discussed as applied to polymers and polymer matrix composites. Comparisons between creep rupture experiments and analytical models are presented. The time dependent creep rupture process in graphite epoxy laminates is examined as a function of temperature and stress level.

Brinson, H. F.↗

The large system of molecular clouds in Orion and Monoceros

Emission is noted over about one-eighth of an 850-sq deg region centered on Orion and Monoceros that has been surveyed in the J = 1 to 0 line of CO; most of the emission arises from giant molecular clouds associated with Orion A and B, and Mon R2. A much smaller area was surveyed for C-13O emission. A comparison of cloud masses obtained by three independent methods indicates that CO luminosity is as accurate a measure of cloud mass as other indicators. The possible relationships among clouds in the survey are discussed, including the conjecture that the overall Orion complex of clouds is a much larger system than previously considered, incorporating most of the clouds in the present survey.

Maddalena, R. J.↗

Comet brightness parameters: Definition, determination, and correlations

The power-law definition of comet brightness is reviewed and possible systematic influences are discussed that can affect the derivation of m sub o and n values from visual magnitude estimates. A rationale for the Bobrovnikoff aperture correction method is given and it is demonstrated that the Beyer extrafocal method leads to large systematic effects which if uncorrected by an instrumental relationship result in values significantly higher than those derived according to the Bobrovnikoff guidelines. A series of visual brightness parameter sets are presented which have been reduced to the same photometric system. Recommendations are given to insure that future observations are reduced to the same system.

Meisel, D. D.↗

Shock structure in non-circular jets

The shock-cell structure of supersonic jets with non-circular exit geometry is modeled using a linearized analysis. The model takes into account the finite thickness of the jet shear layer using realistic velocity and density profiles. The effects of the shear layer turbulence are included by incorporating eddy-viscosity terms. A finite-difference numerical method is used to solve the steady linearized equations of motion. A body-fitted coordinate system is used to describe the shear layer. The variation of the pressure fluctuation with downstream distance is given for circular jets and for an elliptic jet of aspect ratio 2.0. Comparisons with experimental data are made. Difficulties with the numerical technique are also discussed.

Morris, Philip J.↗

Apparatus For Tests Of Percussion Primers

Test apparatus and method developed to measure ignition capability of percussion primers. Closely simulates actual conditions and interfaces encountered in such applications as in munitions and rocket motors. Ignitability-testing apparatus is small bomb instrumented with pressure transducers. Sizes, shapes, and positions of bomb components and materials under test selected to obtain quantitative data on ignition.

Bement, Laurence J.↗

Evaluation of alternatives for trichlorotrifluoroethane (CFC-113) to clean and verify liquid oxygen systems

NASA Langley Research Center (LARC) investigated several alternatives to the use of tri-chloro-tri-fluoroethane(CFC-113) in oxygen cleaning and verification. Alternatives investigated include several replacement solvents, Non-Destructive Evaluation (NDE) and Total Organic Carbon (TOC) analysis. Among the solvents, 1, 1-dichloro-1-fluoroethane (HCFC 141b) and di-chloro-penta-fluoro-propane (HCFC 225) are the most suitable alternatives for cleaning and verification. However, use of HCFC 141b is restricted, HCFC 225 introduces toxicity hazards, and the NDE and TOC methods of verification are not suitable for processes at LaRC. Therefore, the interim recommendation is to sparingly use CFC-113 for the very difficult cleaning tasks where safety is critical and to use HCFC 225 to clean components in a controlled laboratory environment. Meanwhile, evaluation must continue on now solvents and procedures to find one suited to LaRCs oxygen cleaning needs.

Morris, Michelle L.↗

In-situ Characterization of Cast Stainless Steel Microstructures

Cast austenitic stainless steel (CASS) that was commonly used in U.S. nuclear power plants is a coarse-grained, elastically anisotropic material. The engineering properties of CASS made it a material of choice for selected designs of nuclear power reactor systems. However, the fabrication processes result in a variety of coarse-grain microstructures that are difficult to inspect ultrasonically, largely due to detrimental effects of wave interactions with the microstructure. To address the inspection needs, new approaches that are robust to these phenomena are being sought. However, overcoming the deleterious effects of the coarse-grained microstructure on the interrogating ultrasonic beam will require knowledge of the microstructure and the corresponding acoustic properties of the material, for potential optimization of inspection parameters to enhance the probability of detecting flaws. The goal of improving the reliability and effectiveness of ultrasonic inspection of CASS specimens can therefore potentially be achieved by first characterizing the microstructure of the component. The characterization of CASS microstructure must be done in-situ, to enable dynamic selection and optimization of the ultrasonic inspection technique. This paper discusses the application of ultrasonic measurement methods for classifying the microstructure of CASS components, when making measurements from the outside surface of the pipe or component. Results to date demonstrate the potential of ultrasonic and electromagnetic measurements to classify the material type of CASS for two consistent microstructures-equiaxed-grain material and columnar-grain material.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The suppression of low-temperature intergranular brittleness in ferritic Fe-Mn alloys

A method for obtaining cryogenic toughness in an Fe-12Mn-0.2Ti alloy by a controlled cooling technique is presented. The intergranular fracture surface of the quenched alloy, using an AES, revealed no significant difference from that obtained by the bulk transgranular fracture surface, indicating the absence of large-scale grain boundary segregation during the austenitizing treatment. Attention is given to the step cooling method, using a furnace at temperatures of 100 to 120 C, followed by fast cooling to ambient temperature, which in turn produces a high-impact toughness without intergranular brittleness. It is concluded that the sources of brittle intergranular fracture in the alloy are both chemical, operating in martensitic structure, and nonchemical, active during quenching from the austenitizing treatment.

Hwang, S. K.↗

Accelerated characterization of graphite/epoxy composites

A method to predict the long term compliance of unidirectional off-axis laminates from short term laboratory tests is presented. The method uses an orthotropic transformation equation and the time-stress-temperature superposition principle. Short term tests are used to construct master curves for two off-axis unidirectional laminates with fiber angles of 10 and 90 degrees. Analytical predictions of long term compliance for 30 and 60 degrees laminates are made. Comparisons with experimental data are also given.

Griffith, W. I.↗

Evidence for exclusively inorganic formation of magnetite in Martian meteorite ALH84001

Magnetite crystals produced by terrestrial magnetotactic bacterium MV-1 are elongated on a [111] crystallographic axis, in a so-called truncated hexa-Octahedral shape. This morphology has been proposed to constitute a biomarker (i.e., formed only in biogenic processes). A subpopulation of magnetite crystals associated with carbonate globules in Martian meteorite ALH84001 is reported to have this morphology, and the observation has been taken as evidence for biological activity on Mars. In this study, we present evidence for the exclusively inorganic origin of [111]-elongated magnetite crystals in ALH84001. We report three-dimensional(3-D) morphologies for approx.1000 magnetite crystals extracted from: (1) thermal decomposition products of Fe-rich carbonate produced by inorganic hydrothermal precipitation in laboratory experiments; (2) carbonate globules in Martian meteoriteeALH84001; and (3) cells of magnetotactic bacterial strain MV-1. The 3-D morphologies were derived by fitting 3-D shape models to two-dimensional bright-field transmission-electron microscope (TEAM) images obtained at a series of viewing angles. The view down the {110} axes closest to the [111] elongation axis of magnetite crystals ([111]x{110) not equal to 0) provides a 2-D projection that uniquely discriminates among the three [111]-elongated magnetite morphologies found in these samples: [111]-elongated truncated hexaoctahedron ([111]-THO), [111]-elongated cubo-octahedron ([111]-ECO), and [111]-elongated simple octahedron ([111]-ESO). All [111] -elongated morphologies are present in the three types of sample, but in different proportions. In the ALH84001 Martian meteorite and in our inorganic laboratory products, the most common [111]-elongated magnetite crystal morphology is [111]-ECO. In contrast, the most common morphology for magnetotactic bacterial strain MV-1 is [111]-THO. These results show that: (1) the morphology of [111]-elongated magnetite crystals associated with the carbonate globules in Martian meteorite ALH84001 is replicated by an inorganic process; and (2) the most common crystal morphology for biogenic (MV-1) magnetite is distinctly different from that in both ALH84001 and our inorganic laboratory products. Therefore, [111]-elongated magnetite crystals in ALH84001 do not constitute, as previously claimed, a robust biosignature and, in fact, an exclusively inorganic origin for the magnetite is fully consistent with our results. Furthermore, the inorganic synthesis method, i.e., the thermal decomposition of hydrothermally precipitated Fe-rich carbonate, is a process analogue for formation of the magnetite on Mars. Namely, precipitation of carbonate globules from carbonate-rich hydrothermal solutions followed at some later time by a thermal pulse, perhaps in association with meteoritic impact or volcanic processes on the Martian surface.

Golden, D. C.↗

A New Method of Neutron Detecton for UCN Lifetime Measrements

A number of inconsistant neutron lifetime measurements have been reported. The disagreement among the various measurements made with material neutron traps with ultra-cold neutrons (UCN) suggests unaccounted for systematic errors in these measurements. One potential source of error is due to the long emptying times which may be time dependent due to the UCN phase space evolution in the trap. We present a way to reduce this effect.

Morris, C. L.↗

Methods for the In-Situ Characterization of Cast Austenitic Stainless Steel Microstructures

Cast austenitic stainless steel (CASS) that was commonly used in U.S. nuclear power plants is a coarse-grained, elastically anisotropic material. Its engineering properties made it a material of choice for selected designs of nuclear power reactor systems. However, the fabrication processes result in a variety of coarse-grain microstructures that make current ultrasonic in-service inspection of components quite challenging. To address inspection needs, new ultrasonic inspection approaches are being sought. However, overcoming the deleterious and variable effects of the microstructure on the interrogating ultrasonic beam may require knowledge of the microstructure, for potential optimization of inspection parameters to enhance the probability of detection (POD). The ability to classify microstructure type (e.g. polycrystalline or columnar) has the potential to guide selection of optimal NDE approaches. This paper discusses the application of ultrasonic and electromagnetic methods for classifying CASS microstructures, when making measurements from the outside surface of the component. Results to date demonstrate the potential of these measurements to discriminate between two consistent microstructures - equiaxed-grain material versus columnar-grain material. The potential for fusion of ultrasonic and electromagnetic measurements for in-situ microstructure characterization in CASS materials will be explored.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Remote sensing as a tool for estimating soil erosion potential

The Universal Soil Loss Equation is a frequently used methodology for estimating soil erosion potential. The Universal Soil Loss Equation requires a variety of types of geographic information (e.g. topographic slope, soil erodibility, land use, crop type, and soil conservation practice) in order to function. This information is traditionally gathered from topographic maps, soil surveys, field surveys, and interviews with farmers. Remote sensing data sources and interpretation techniques provide an alternative method for collecting information regarding land use, crop type, and soil conservation practice. Airphoto interpretation techniques and medium altitude, multi-date color and color infrared positive transparencies (70mm) were utilized in this study to determine their effectiveness for gathering the desired land use/land cover data. Successful results were obtained within the test site, a 6136 hectare watershed in Dane County, Wisconsin.

Morris-Jones, D. R.↗

Tests of cosmic ray radiography for power industry applications

In this report, we assess muon multiple scattering tomography as a non-destructive inspection technique in several typical areas of interest to the nuclear power industry, including monitoring concrete degradation, gate valve conditions, and pipe wall thickness. This work is motivated by the need for imaging methods that do not require the licensing, training, and safety controls of x-rays, and by the need to be able to penetrate considerable overburden to examine internal details of components that are otherwise inaccessible, with minimum impact on industrial operations. In some scenarios, we find that muon tomography may be an attractive alternative to more typical measurements.

36 MATERIALS SCIENCE↗

PoolDilutionR : An R package for easy optimization of isotope pool dilution calculations

Abstract Isotopic pool dilution is a powerful approach to quantify gross biogeochemical transformation rates, but remains seldom used despite its potential. To facilitate broader implementation of pool dilution methods, we present a user‐friendly R package that optimizes gross production and consumption rates (and optionally fractionation constants as well) based on standard pool dilution time series data. This package features extensive documentation and example analyses, and is easily integrated into analytical pipelines. With this open‐source tool, the biogeochemistry community will be able to readily apply isotope pool dilution to a wide range of processes.

59 BASIC BIOLOGICAL SCIENCES↗

GEOS. User Tutorials

GEOS is a massively parallel, multi-physics simulation application utilizing high performance computing (HPC) to address subsurface reservoir stimulation activities with the goal of optimizing current operations and evaluating innovative stimulation methods. GEOS enables coupling of di erent solvers associated with the various physical processes occurring during reservoir stimulation in unique and sophisticated ways, adapted to various geologic settings, materials and stimulation methods. Developed at the Lawrence Livermore National Laboratory (LLNL) as a part of a Laboratory-Directed Research and Development (LDRD) Strategic Initiative (SI) project, GEOS represents the culmination of a multi-year ongoing code development and improvement e ort that has leveraged existing code capabilities and sta expertise to design new computational geosciences software.

58 GEOSCIENCES↗

Multivariate Methods for Prediction of Geologic Sample Composition with Laser-Induced Breakdown Spectroscopy

Laser-induced breakdown spectroscopy (LIBS) uses pulses of laser light to ablate a material from the surface of a sample and produce an expanding plasma. The optical emission from the plasma produces a spectrum which can be used to classify target materials and estimate their composition. The ChemCam instrument on the Mars Science Laboratory (MSL) mission will use LIBS to rapidly analyze targets remotely, allowing more resource- and time-intensive in-situ analyses to be reserved for targets of particular interest. ChemCam will also be used to analyze samples that are not reachable by the rover's in-situ instruments. Due to these tactical and scientific roles, it is important that ChemCam-derived sample compositions are as accurate as possible. We have compared the results of partial least squares (PLS), multilayer perceptron (MLP) artificial neural networks (ANNs), and cascade correlation (CC) ANNs to determine which technique yields better estimates of quantitative element abundances in rock and mineral samples. The number of hidden nodes in the MLP ANNs was optimized using a genetic algorithm. The influence of two data preprocessing techniques were also investigated: genetic algorithm feature selection and averaging the spectra for each training sample prior to training the PLS and ANN algorithms. We used a ChemCam-like laboratory stand-off LIBS system to collect spectra of 30 pressed powder geostandards and a diverse suite of 196 geologic slab samples of known bulk composition. We tested the performance of PLS and ANNs on a subset of these samples, choosing to focus on silicate rocks and minerals with a loss on ignition of less than 2 percent. This resulted in a set of 22 pressed powder geostandards and 80 geologic samples. Four of the geostandards were used as a validation set and 18 were used as the training set for the algorithms. We found that PLS typically resulted in the lowest average absolute error in its predictions, but that the optimized MLP ANN and the CC ANN often gave results comparable to PLS. Averaging the spectra for each training sample and/or using feature selection to choose a small subset of wavelengths to use for predictions gave mixed results, with degraded performance in some cases and similar or slightly improved performance in other cases. However, training time was significantly reduced for both PLS and ANN methods by implementing feature selection, making this a potentially appealing method for initial, rapid-turn-around analyses necessary for Chemcam's tactical role on MSL. Choice of training samples has a strong influence on the accuracy of predictions. We are currently investigating the use of clustering algorithms (e.g. k-means, neural gas, etc.) to identify training sets that are spectrally similar to the unknown samples that are being predicted, and therefore result in improved predictions

Morris, Richard↗

Regional Radiological Security Partnership in Southeast Asia – Increasing the Sustainability of Security Systems at the Site-Level by Using a Model Facility Approach

In 2004, Australia, through the Australian Nuclear Science and Technology Organisation (ANSTO), created the Regional Security of Radioactive Sources (RSRS) project and partnered with the U.S. Department of Energy’s Global Threat Reduction Initiative (GTRI) and the International Atomic Energy Agency (IAEA) to form the Southeast Asian Regional Radiological Security Partnership (RRSP). The intent of the RRSP is to cooperate with countries in Southeast Asia to improve the security of their radioactive sources. This Southeast Asian Partnership supports objectives to improve the security of high risk radioactive sources by raising awareness of the need and developing national programs to protect and control such materials, improve the security of such materials, and recover and condition the materials no longer in use. The RRSP has utilized many tools to meet those objectives including: provision of physical protection upgrades, awareness training, physical protection training, regulatory development, locating and recovering orphan sources, and most recently - development of model security procedures at a model facility. This paper discusses the benefits of establishing a model facility, the methods employed by the RRSP, and three of the expected outcomes of the Model Facility approach. The first expected outcome is to increase compliance with source security guidance materials and national regulations by adding context to those materials, and illustrating their impact on a facility. Second, the effectiveness of each of the tools above is increased by making them part of an integrated system. Third, the methods used to develop the model procedures establishes a sustainable process that can ultimately be transferred to all facilities beyond the model. Overall, the RRSP has utilized the Model Facility approach as an important tool to increase the security of radioactive sources, and to position facilities and countries for the long term secure management of those sources.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗