At least 307 records · Page 17

Leveraging Topological Events in Tracking Graphs for Understanding Particle Diffusion

Abstract Single particle tracking (SPT) of fluorescent molecules provides significant insights into the diffusion and relative motion of tagged proteins and other structures of interest in biology. However, despite the latest advances in high‐resolution microscopy, individual particles are typically not distinguished from clusters of particles. This lack of resolution obscures potential evidence for how merging and splitting of particles affect their diffusion and any implications on the biological environment. The particle tracks are typically decomposed into individual segments at observed merge and split events, and analysis is performed without knowing the true count of particles in the resulting segments. Here, we address the challenges in analyzing particle tracks in the context of cancer biology. In particular, we study the tracks of KRAS protein, which is implicated in nearly 20% of all human cancers, and whose clustering and aggregation have been linked to the signaling pathway leading to uncontrolled cell growth. We present a new analysis approach for particle tracks by representing them as tracking graphs and using topological events – merging and splitting, to disambiguate the tracks. Using this analysis, we infer a lower bound on the count of particles as they cluster and create conditional distributions of diffusion speeds before and after merge and split events. Using thousands of time‐steps of simulated and in‐vitro SPT data, we demonstrate the efficacy of our method, as it offers the biologists a new, detailed look into the relationship between KRAS clustering and diffusion speeds.

McDonald, T.↗

Intensity-Modulated Radiotherapy Optimization in a Quasi-Periodically Deforming Patient Model

Purpose: To present the implementation of a probability-based, four-dimensional (4D) intensity-modulated radiotherapy (IMRT) planning approach that explicitly optimizes the accumulated dose to moving tissue, estimated using the patient's probability density function (pdf) of respiratory motion. This is termed 'optimization in tissue's-eye-view'. Methods and Materials: The method incorporates 4D Monte Carlo dose calculation in multiple geometries of a respiratory-correlated CT dataset. The instance doses are weighted according to the breathing pdf and accumulated in a common reference geometry, which involves dose warping based on deformable registration. The algorithm produces deliverable multileaf collimator segments and was tested on a sample lung cancer patient dataset with large target excursion. Accumulated doses of the moving target and organs at risk of this plan were compared with those of corresponding margin-based static IMRT plans for free-breathing and gated treatment, as well as target tracking. Results: Target tracking provided best target coverage. Both the presented 4D IMRT approach for free-breathing treatment and gated treatment gave similar results for target coverage and lung dose, with significantly better target coverage than the margin-based static IMRT plan for free-breathing treatment. Conclusions: The presented 4D planning concept offers an alternative to gating by providing the optimal dose for free-breathing IMRT treatment. Although the focus of this study was 4D lung planning, the approach can be generally applied for IMRT optimization in randomly deforming patient models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The influence of the liquid-to-solid transitions on the changes of macromolecules from disorder to order

When crystallizing macromolecules, one needs to recognize that they are sufficiently long to connect neighboring phases. This coupling between the phases is the reason that on ordering, practically all polymers develop a globally metastable, semicrystalline structure, consisting of multiple phases with different degrees of mobility. The ordered and amorphous phases are separated by nanophases of strained segments of molecule of nanometer dimensions, consisting of rigid-amorphous fractions, RAFs, which soften, above, within, or below the often very broad melting range of the ordered phases. Thus, ordering of a melt of macromolecules causes significant changes in the remaining amorphous phases. A summary of the various phases is given in terms of their structures, molecular vibrations, and large-amplitude motion as they influence the glass and order-disorder transitions. This is followed by a description of the limits of the classical nucleation theory of crystals when applied to macromolecules. Discussed in detail are the problems in primary and secondary nucleation which arise from the presence of RAFs. Special macromolecular nucleation processes that needed to be considered are the self-nucleation on cooling from above the melting temperature or on heating from above the glass transition temperature, and the molecular nucleation causing molar mass segregation on ordering. Finally, the glass transitions of the phases of various sizes and degree of order are discussed on hand of selected, pertinent examples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ground motion response to an ML 4.3 earthquake using co-located distributed acoustic sensing and seismometer arrays

The PoroTomo research team deployed two arrays of seismic sensors in a natural laboratory at Brady Hot Springs, Nevada in March 2016. The 1500 m (length) by 500 m (width) by 400 m (depth) volume of the laboratory overlies a geothermal reservoir. The surface Distributed Acoustic Sensing (DAS) array consisted of 8700 m of fiber-optic cable in a shallow trench, including 340 m in a well. The conventional seismometer array consisted of 238 three- component geophones. The DAS cable was laid out in three parallel zig-zag lines with line segments approximately 100 meters in length and geophones were spaced at approximately 60- meter intervals. Both DAS and conventional geophones recorded continuously over 15 days during which a moderate-sized earthquake with a local magnitude of 4.3 was recorded on March 21, 2016. Its epicenter was approximately 150-km south-southeast of the laboratory. Several DAS line segments with co-located geophone stations were used to compare signal-to-noise (SNR) ratios in both time and frequency domains and to test relationships between DAS and geophone data. The ratios were typically within a factor of five of each other with DAS SNR often greater for P-wave but smaller for S-wave relative to geophone SNR. The SNRs measured for an earthquake can be better than for active sources, because the earthquake signal contains more low frequency energy and the noise level is also lower at those lower frequencies. Amplitudes of the sum of several DAS strain-rate waveforms matched the finite difference of two geophone waveforms reasonably well, as did the amplitudes of DAS strain waveforms with particle-velocity waveforms recorded by geophones. Similar agreement was found between DAS and geophone observations and synthetic strain seismograms. In conclusion, the combination of good SNR in the seismic frequency band, high-spatial density, large N, and highly accurate time control among individual sensors suggests that DAS arrays have potential to assume a role in earthquake seismology.

60 signal-to-noise ratio↗

Dynamics of water around the complex structures formed between the KH domains of far upstream element binding protein and single-stranded DNA molecules

Single-stranded DNA (ss-DNA) binding proteins specifically bind to the single-stranded regions of the DNA and protect it from premature annealing, thereby stabilizing the DNA structure. We have carried out atomistic molecular dynamics simulations of the aqueous solutions of two DNA binding K homology (KH) domains (KH3 and KH4) of the far upstream element binding protein complexed with two short ss-DNA segments. Attempts have been made to explore the influence of the formation of such complex structures on the microscopic dynamics and hydrogen bond properties of the interfacial water molecules. It is found that the water molecules involved in bridging the ss-DNA segments and the protein domains form a highly constrained thin layer with extremely retarded mobility. These water molecules play important roles in freezing the conformational oscillations of the ss-DNA oligomers and thereby forming rigid complex structures. Further, it is demonstrated that the effect of complexation on the slow long-time relaxations of hydrogen bonds at the interface is correlated with hindered motions of the surrounding water molecules. Importantly, it is observed that the highly restricted motions of the water molecules bridging the protein and the DNA components in the complexed forms originate from more frequent hydrogen bond reformations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Geometrically projected discrete dislocation dynamics

Three-dimensional discrete dislocation dynamics methods (3D-DDD) have been developed to explicitly track the motion of individual dislocations under applied stress. At present, these methods are limited to plastic strains of about one percent or less due to high computational cost associated with the interactions between large numbers of dislocations. This limitation motivates the construction of minimalistic approaches to efficiently simulate the motion of dislocations for higher strains and longer time scales. In the present study, we propose geometrically projected discrete dislocation dynamics (GP-DDD), a method in which dislocation loops are modeled as geometrical objects that maintain their shape with a constant number of degrees of freedom as they expand. We present an example where rectangles composed of two screw and two edge dislocation segments are used for modeling gliding dislocation loops. We use this model to simulate single slip loading of copper and compare the results with detailed 3D-DDD simulations. We discuss the regimes in which GP-DDD is able to adequately capture the variation of the flow stress with strain rate in the single slip loading condition. In conclusion, a simulation using GP-DDD requires ~40 times fewer degrees of freedom for a copper single slip loading case, thus reducing computational time and complexity.

36 MATERIALS SCIENCE↗

Late Quaternary slip-rate along the central Bangong-Chaxikang segment of the Karakorum fault, western Tibet

Insight into the spatial and temporal changes of slip-rate is essential to understand the kinematic role of large strike-slip faults in continental collision zones. Geodetic and geologic rates from present to several million years ago along the Karakorum fault range from 0 to 11 mm/yr. Here, we determine the first late Quaternary slip-rate at the southern end of the linear Bangong-Chaxikang segment of the Karakorum fault, using cumulative offsets (20–200 m) of fans and terraces at three sites, as well as 74 new 10 Be surface-exposure ages to constrain the age of these offset geomorphic markers. The rate is >3 mm/yr at sites Gun and Chaxikang, and it is >1.7–2.2 mm/yr at the Gar fan site. Together with rates obtained along the southernmost Menshi-Kailas segment, the Karakorum fault slip-rate seems to increase southeastward from south of Bangong Lake to Kailas (from >3 to >8 mm/yr). These Karakorum fault slip-rate data (>3–8 mm/yr), together with the total length of the fault (>1000 km) and its initiation age (>13–23 Ma), confirm that the Karakorum fault is the major fault accommodating dextral strike-slip motion NE of the western Himalayas. Furthermore, the dextral Karakorum fault in the south and the conjugate left-lateral Longmu Co–Altyn Tagh fault system in the north are thus the major strike-slip faults of western Tibet, which contribute to eastward extrusion of Tibet.

58 GEOSCIENCES↗

A fiducial detection algorithm for real-time image guided IMRT based on simultaneous MV and kV imaging

The advantage of highly conformal dose techniques such as 3DCRT and IMRT is limited by intrafraction organ motion. A new approach to gain near real-time 3D positions of internally implanted fiducial markers is to analyze simultaneous onboard kV beam and treatment MV beam images (from fluoroscopic or electronic portal image devices). Before we can use this real-time image guidance for clinical 3DCRT and IMRT treatments, four outstanding issues need to be addressed. (1) How will fiducial motion blur the image and hinder tracking fiducials? kV and MV images are acquired while the tumor is moving at various speeds. We find that a fiducial can be successfully detected at a maximum linear speed of 1.6 cm/s. (2) How does MV beam scattering affect kV imaging? We investigate this by varying MV field size and kV source to imager distance, and find that common treatment MV beams do not hinder fiducial detection in simultaneous kV images. (3) How can one detect fiducials on images from 3DCRT and IMRT treatment beams when the MV fields are modified by a multileaf collimator (MLC)? The presented analysis is capable of segmenting a MV field from the blocking MLC and detecting visible fiducials. This enables the calculation of nearly real-time 3D positions of markers during a real treatment. (4) Is the analysis fast enough to track fiducials in nearly real time? Multiple methods are adopted to predict marker positions and reduce search regions. The average detection time per frame for three markers in a 1024x768 image was reduced to 0.1 s or less. Solving these four issues paves the way to tracking moving fiducial markers throughout a 3DCRT or IMRT treatment. Altogether, these four studies demonstrate that our algorithm can track fiducials in real time, on degraded kV images (MV scatter), in rapidly moving tumors (fiducial blurring), and even provide useful information in the case when some fiducials are blocked from view by the MLC. This technique can provide a gating signal or be used for intra-fractional tumor tracking on a Linac equipped with a kV imaging system. Any motion exceeding a preset threshold can warn the therapist to suspend a treatment session and reposition the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The development of a population of 4D pediatric XCAT phantoms for imaging research and optimization

Purpose: We previously developed a set of highly detailed 4D reference pediatric extended cardiac-torso (XCAT) phantoms at ages of newborn, 1, 5, 10, and 15 yr with organ and tissue masses matched to ICRP Publication 89 values. In this work, we extended this reference set to a series of 64 pediatric phantoms of varying age and height and body mass percentiles representative of the public at large. The models will provide a library of pediatric phantoms for optimizing pediatric imaging protocols. Methods: High resolution positron emission tomography-computed tomography data obtained from the Duke University database were reviewed by a practicing experienced radiologist for anatomic regularity. The CT portion of the data was then segmented with manual and semiautomatic methods to form a target model defined using nonuniform rational B-spline surfaces. A multichannel large deformation diffeomorphic metric mapping algorithm was used to calculate the transform from the best age matching pediatric XCAT reference phantom to the patient target. The transform was used to complete the target, filling in the nonsegmented structures and defining models for the cardiac and respiratory motions. The complete phantoms, consisting of thousands of structures, were then manually inspected for anatomical accuracy. The mass for each major tissue was calculated and compared to linearly interpolated ICRP values for different ages. Results: Sixty four new pediatric phantoms were created in this manner. Each model contains the same level of detail as the original XCAT reference phantoms and also includes parameterized models for the cardiac and respiratory motions. For the phantoms that were 10 yr old and younger, we included both sets of reproductive organs. This gave them the capability to simulate both male and female anatomy. With this, the population can be expanded to 92. Wide anatomical variation was clearly seen amongst the phantom models, both in organ shape and size, even for models of the same age and sex. The phantoms can be combined with existing simulation packages to generate realistic pediatric imaging data from different modalities. Conclusions: This work provides a large cohort of highly detailed pediatric phantoms with 4D capabilities of varying age, height, and body mass. The population of phantoms will provide a vital tool with which to optimize 3D and 4D pediatric imaging devices and techniques in terms of image quality and radiation-absorbed dose.

60 APPLIED LIFE SCIENCES↗

Dynamics of dendritic polymers in the bulk and under confinement

The structure and dynamics of a hyperbranched polyesteramide (Hybrane® S 1200) polymer and its nanocomposites with natural montmorillonite (Na{sup +}-MMT) are investigated by XRD, DSC, QENS, DS and Molecular Dynamics (MD) simulation. In bulk, the energy-resolved elastically scattered intensity from the polymer exhibits two relaxation steps, one attributed to sub-T{sub g} motions and one observed at temperatures above the glass transition, T{sub g}. The QENS spectra measured over the complete temperature range are consistent with the elastic measurements and can be correlated to the results emerging from the detailed description afforded by the atomistic simulations, which predict the existence of three relaxation processes. Moreover, dielectric spectroscopy shows the sub- T{sub g} beta process as well as the segmental relaxation. For the nanocomposites, XRD reveals an intercalated structure for all hybrids with distinct interlayer distances due to polymer chains residing within the galleries of the Na{sup +}-MMT. The polymer chains confined within the galleries show similarities in the behavior with that of the polymer in the bulk for temperatures below the bulk polymer T{sub g}, whereas they exhibit frozen dynamics under confinement at temperatures higher than that.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Validation of a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial HDR brachytherapy

Purpose: In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. Methods: For this work, a new computer controlled robotic 3DUS system was built to perform a hybrid motion scan, which is a combination of a 6 cm linear translation with a 30° rotation at both ends. The new 3DUS scanner was designed to fit on a modified Kuske assembly, keeping the current template grid configuration but modifying the frame to allow the mounting of the 3DUS system at several positions. A finer grid was also tested. A user interface was developed to perform image reconstruction, semiautomatic segmentation of the surgical bed as well as catheter reconstruction and tracking. A 3D string phantom was used to validate the geometric accuracy of the reconstruction. The volumetric accuracy of the system was validated with phantoms using magnetic resonance imaging (MRI) and computed tomography (CT) images. In order to accurately determine whether 3DUS can effectively replace CT for treatment planning, the authors have compared the 3DUS catheter reconstruction to the one obtained from CT images. In addition, in agarose-based phantoms, an end-to-end procedure was performed by executing six independent complete procedures with both 14 and 16 catheters, and for both standard and finer Kuske grids. Finally, in phantoms, five end-to-end procedures were performed with the final CT planning for the validation of 3DUS preplanning. Results: The 3DUS acquisition time is approximately 10 s. A paired Student t-test showed that there was no statistical significant difference between known and measured values of string separations in each direction. Both MRI and CT volume measurements were not statistically different from 3DUS volume (Student t-test: p > 0.05) and they were significantly correlated to 3DUS measurement (Pearson test: MRI p < 0.05 and CT p < 0.001). The mean angular separation distance between catheter trajectories segmented from 3DUS and CT images was 0.42° ± 0.24°, while the maximum and mean trajectory separations were 0.51 ± 0.19 and 0.37 ± 0.17 mm, respectively. Overall, the new finer grid has performed significantly better in terms of dosimetric indices. The planning target volume dosimetric indices were not found statistically different between 3DUS and CT planning (Student t-test, p > 0.05). Both the skin and the pectoral muscle dosimetric indices were within ABS guidelines. Conclusions: A novel robot-assisted 3DUS system was designed and validated. To their knowledge, this is the first system capable of performing real-time guidance and planning of breast multicatheter HDR brachytherapy treatments. Future investigation will test the feasibility of using the system in the clinic and for permanent breast brachytherapy.

60 APPLIED LIFE SCIENCES↗

SU-G-BRA-04: Simulation of Errors in Maximal Intensity Projection (MIP)-Based Lung Tumor Internal Target Volumes (ITV) Using Real-Time 2D MRI and Deformable Image Registration Based Lung Tumor Tracking

Purpose: To evaluate the effect of inter- and intra-fractional tumor motion on the error in four-dimensional computed tomography (4DCT) maximal intensity projection (MIP)–based lung tumor internal target volumes (ITV), using deformable image registration of real-time 2D-sagital cine-mode MRI acquired during lung SBRT treatments. Methods: Five lung tumor patients underwent free breathing SBRT treatment on the ViewRay, with dose prescribed to PTV (4DCT MIP-based ITV+3–6mm margin). Sagittal slice cine-MR images (3.5×3.5mm pixels) were acquired through the center of the tumor at 4 frames per second throughout the treatments (3–4 fractions of 21–32 minutes duration). Tumor GTVs were contoured on the first frame of the cine and tracked throughout the treatment using off-line optical-flow based deformable registration implemented on a GPU cluster. Pseudo-4DCT MIP-based ITVs were generated from MIPs of the deformed GTV contours limited to short segments of image data. All possible pseudo-4DCT MIP-based ITV volumes were generated with 1s resolution and compared to the ITV volume of the entire treatment course. Varying pseudo-4DCT durations from 10-50s were analyzed. Results: Tumors were covered in their entirety by PTV in the patients analysed here. However, pseudo-4DCT based ITV volumes were observed that were as small as 29% of the entire treatment-ITV, depending on breathing irregularity and the duration of pseudo-4DCT. With an increase in duration of pseudo-4DCT from 10–50s the minimum volume acquired from 95% of all pseudo-4DCTs increased from 62%–81% of the treatment ITV. Conclusion: A 4DCT MIP-based ITV offers a ‘snap-shot’ of breathing motion for the brief period of time the tumor is imaged on a specific day. Real time MRI over prolonged periods of time and over multiple treatment fractions shows that the accuracy of this snap-shot varies according to inter- and intra-fractional tumor motion. Further work is required to investigate the dosimetric effect of these results.

60 APPLIED LIFE SCIENCES↗

Fault geometry inversion and slip distribution of the 2010 M w 7.2 El Mayor-Cucapah earthquake from geodetic data

The 4 April 2010 M w 7.2 El Mayor-Cucapah (EMC) earthquake in Baja, California, and Sonora, Mexico, had primarily right-lateral strike-slip motion and a minor normal-slip component. The surface rupture extended about 120 km in a NW-SE direction, west of the Cerro Prieto fault. We use geodetic measurements including near- to far-field GPS, interferometric synthetic aperture radar (InSAR), and subpixel offset measurements of radar and optical images to characterize the fault slip during the EMC event. We use dislocation inversion methods and determine an optimal nine-segment fault geometry, as well as a subfault slip distribution from the geodetic measurements. With systematic perturbation of the fault dip angles, randomly removing one geodetic data constraint, or different data combinations, we are able to explore the robustness of the inferred slip distribution along fault strike and depth. The model fitting residuals imply contributions of early postseismic deformation to the InSAR measurements as well as lateral heterogeneity in the crustal elastic structure between the Peninsular Ranges and the Salton Trough. We also find that with incorporation of near-field geodetic data and finer fault patch size, the shallow slip deficit is reduced in the EMC event by reductions in the level of smoothing. Finally, these results show that the outcomes of coseismic inversions can vary greatly depending on model parameterization and methodology.

58 GEOSCIENCES↗

Traveling electric field probed by a fine particle above voltage-modulated strips in a striped electrode device

It is described that the distribution of the horizontal electric field above a striped electrode can be inferred from the trajectory of a single fine particle with known mass and diameter. The striped electrode consists of 100 segmented stainless steel strips, each electrically insulated. A traveling periodic potential profile is produced above the striped electrode by modulating the voltage signals on the strips. When the voltage modulation is on, the fine particle, which is originally levitated in the sheath region above the striped electrode, experiences a periodic oscillation along both the vertical and the horizontal directions because of the periodic electric force arising from the modulation voltages. Tracking the motion of the fine particles, the electric force is obtained from the momentum equation including the gravity and the neutral gas friction. With the particle charge estimated by the vertical oscillation method, the electric field can be derived. The horizontal electric field obtained by this method is in agreement with the result predicted by a collisional particle-in-cell simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long-Duration High-Resolution Large-Eddy Simulations of Hurricane Laura (2020) for Infrastructure Design

This dataset provides long-duration large-eddy simulations (LES) of Hurricane Laura (2020), capturing the turbulent boundary-layer wind field during the storm's passage at horizontal grid spacings of 55.55 m and 10 m. Hurricane Laura made landfall as a Category 4 storm in southwestern Louisiana at 06:00 UTC on 27 August 2020, producing widespread damage to coastal infrastructure. The simulations characterize the spatial and temporal variability of the turbulent wind at heights spanning the lowest 300 m of the boundary layer, throughout the approach and passage of the storm's eyewall over a fixed location. To resolve the spatial heterogeneity of wind and turbulence conditions across the storm, seven independent refined LES runs are performed at radial locations spanning the storm relative to its direction of motion. The refinement positions are defined on a normalized radial coordinate r ̂=r/R, where R≈21 km is Laura's radius of maximum wind, and lie between r ̂=-1.5 and r ̂=+1.5 in ∆r ̂=0.5 increments along a line perpendicular to the storm's track at the midpoint of the simulation. Negative r ̂ corresponds to locations south-southwest of the storm center and positive r ̂ to locations north-northeast. The dataset is segmented into seven radial refinement groups.

17 WIND ENERGY↗

How non-bonding domains affect the active assembly of microtubule spools

We report that structural defects can determine and influence various properties of materials, and many technologies rely on the manipulation of defects ( e.g. , semiconductor industries). In biological systems, management of defects/errors ( e.g. DNA repair) is critical to an organism's survival, which has inspired the design of artificial nanomachines that mimic nature's ability to detect defects and repair damage. Biological motors have captured considerable attention in developing such capabilities due to their ability to convert energy into directed motion in response to environmental stimuli, which maximizes their ability for detection and repair. The objective of the present study was to develop an understanding of how the presence of non-bonding domains, here considered as a “defect”, in microtubule (MT) building blocks affect the kinesin-driven, active assembly of MT spools. The assembly/joining of micron-scale bonding ( i.e. , biotin-containing) and non-bonding ( i.e. , no biotin) MTs resulted in segmented MT building blocks consisting of alternating bonding and non-bonding domains. Here, the introduction of these MT building blocks into a kinesin gliding motility assay along with streptavidin-coated quantum dots resulted in the active assembly of spools with altered morphology but retained functionality. Moreover, it was noted that non-bonding domains were autonomously and preferentially released from the spools over time, representing a mechanism by which defects may be removed from these structures. In conclusion, our findings demonstrate that this active assembly system has an intrinsic ability for quality control, which can be potentially expanded to a wide range of applications such as self-regulation and healing of active materials.

36 MATERIALS SCIENCE↗

Three-dimensional measurement of small mechanical parts under a complicated background based on stereo vision

We present an effective method for the accurate three-dimensional (3D) measurement of small industrial parts under a complicated noisy background, based on stereo vision. To effectively extract the nonlinear features of desired curves of the measured parts in the images, a strategy from coarse to fine extraction is employed, based on a virtual motion control system. By using the multiscale decomposition of gray images and virtual beam chains, the nonlinear features can be accurately extracted. By analyzing the generation of geometric errors, the refined feature points of the desired curves are extracted. Then the 3D structure of the measured parts can be accurately reconstructed and measured with least squares errors. Experimental results show that the presented method can accurately measure industrial parts that are represented by various line segments and curves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗