Search NASA⌕ Search

SEARCH · Search NASA

Results for “NORM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Instabilities in the aether

We investigate the stability of theories in which Lorentz invariance is spontaneously broken by fixed-norm vector 'aether' fields. Models with generic kinetic terms are plagued either by ghosts or by tachyons, and are therefore physically unacceptable. There are precisely three kinetic terms that are not manifestly unstable: a sigma model ({partial_derivative}{sub {mu}}A{sub {nu}}){sup 2}, the Maxwell Lagrangian F{sub {mu}}{sub {nu}}F{sup {mu}}{sup {nu}}, and a scalar Lagrangian ({partial_derivative}{sub {mu}}A{sup {mu}}){sup 2}. The timelike sigma-model case is well defined and stable when the vector norm is fixed by a constraint; however, when it is determined by minimizing a potential there is necessarily a tachyonic ghost, and therefore an instability. In the Maxwell and scalar cases, the Hamiltonian is unbounded below, but at the level of perturbation theory there are fewer degrees of freedom and the models are stable. However, in these two theories there are obstacles to smooth evolution for certain choices of initial data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Possible treatment of the ghost states in the Lee-Wick standard model

In this work, we employ the techniques used to cure the indefinite norm problem in pseudo-Hermitian Hamiltonians to show that the ghost states in a higher derivative scalar field theory are not real ghosts. For the model under investigation, an imaginary auxiliary field is introduced to have an equivalent non-Hermitian two-field scalar theory. We were able to calculate exactly the positive definite metric operator {eta} for the quantum mechanical as well as the quantum field versions of the theory. While the equivalent Hamiltonian is non-Hermitian in a Hilbert space characterized by the Dirac sense inner product, it is, however, a Hermitian in a Hilbert space endowed with the inner product <n|{eta}|m>. The main feature of the latter Hilbert space is that the propagator has the correct sign (no Lee-Wick fields). Moreover, the calculated metric operator diagonalizes the Hamiltonian in the two fields (no mixing). We found that the Hermiticity of the calculated metric operator to lead to the constrain M>2m for the two Higgs masses, in agreement with other calculations in the literature. Besides, our mass formulas coincide with those obtained in other works (obtained by a very different regime but with the existence of ghost states), which means that our positive normed Hamiltonian form preserves the mass spectra.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Black holes admitting a Freudenthal dual

The quantized charges x of four-dimensional stringy black holes may be assigned to elements of an integral Freudenthal triple system whose automorphism group is the corresponding U duality and whose U-invariant quartic norm {delta}(x) determines the lowest-order entropy. Here, we introduce a Freudenthal duality x{yields}x-tilde, for which x-tilde-tilde=-x. Although distinct from U duality, it nevertheless leaves {delta}(x) invariant. However, the requirement that x-tilde be an integer restricts us to the subset of black holes for which {delta}(x) is necessarily a perfect square. The issue of higher-order corrections remains open as some, but not all, of the discrete U-duality invariants are Freudenthal invariant. Similarly, the quantized charges A of five-dimensional black holes and strings may be assigned to elements of an integral Jordan algebra, whose cubic norm N(A) determines the lowest-order entropy. We introduce an analogous Jordan dual A*, with N(A) necessarily a perfect cube, for which A**=A and which leaves N(A) invariant. The two dualities are related by a 4D/5D lift.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Finite energy shifts in SU(n) supersymmetric Yang-Mills theory on T{sup 3}xR at weak coupling

We consider a perturbative treatment, in the regime of weak gauge coupling, of supersymmetric Yang-Mills theory in a space-time of the form T{sup 3}xR with SU(n)/Z{sub n} gauge group and a nontrivial gauge bundle. More specifically, we consider the theories obtained as power series expansions around a certain class of normalizable vacua of the classical theory, corresponding to isolated points in the moduli space of flat connections, and the perturbative corrections to the free energy eigenstates and eigenvalues in the weakly interacting theory. The perturbation theory construction of the interacting Hilbert space is complicated by the divergence of the norm of the interacting states. Consequently, the free and interacting Hilbert spaces furnish unitarily inequivalent representations of the algebra of creation and annihilation operators of the quantum theory. We discuss a consistent redefinition of the Hilbert space norm to obtain the interacting Hilbert space and the properties of the interacting representation. In particular, we consider the lowest nonvanishing corrections to the free energy spectrum and discuss the crucial importance of supersymmetry for these corrections to be finite.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uniform-density Bose-Einstein condensates of the Gross-Pitaevskii equation found by solving the inverse problem for the confining potential

Here, in this work, we consider a “reverse-engineering” approach to construct confining potentials that support exact, constant density kovaton solutions to the classical Gross-Pitaevskii equation (GPE) also known as the nonlinear Schr¨odinger equation (NLSE). In the one-dimensional case, the exact solution is the sum of stationary kink and anti-kink solutions, i.e. a kovaton, and in the overlapping region, the density is constant. In higher dimensions, the exact solutions are generalizations of this wave function. In the absence of self-interactions, the confining potential is similar to a smoothed out finite square well with minima also at the edges. When self-interactions are added, a term proportional to ±gψ*ψ gets added to the confining potential and ±gM, where M is the norm, gets added to the total energy. In the realm of stability analysis, we find (linearly) stable solutions in the case with repulsive self-interactions which also are stable to self-similar deformations. For attractive interactions, however, the minima at the edges of the potential get deeper and a barrier in the center forms as we increase the norm. This leads to instabilities at a critical value of M (related to the number of particles in the BEC). Comparing the stability criteria from Derrick’s theorem and Bogoliubov-de Gennes analysis stability results, we find that both predict stability for repulsive self-interactions and instability at a critical mass M for attractive interactions. However, the numerical analysis gives a much lower critical mass. The numerical analysis shows further that the initial instabilities violate the symmetry x → -x assumed by Derrick’s theorem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Localization and delocalization of two-dimensional discrete solitons pinned to linear and nonlinear defects

We study the dynamics of two-dimensional (2D) localized modes in the nonlinear lattice described by the discrete nonlinear Schroedinger equation, including a local linear or nonlinear defect. Discrete solitons pinned to the defects are investigated by means of the numerical continuation from the anticontinuum limit and also using the variational approximation, which features a good agreement for strongly localized modes. The models with the time-modulated strengths of the linear or nonlinear defect are considered too. In that case, one can temporarily shift the critical norm, below which localized 2D modes cannot exist, to a level above the norm of the given soliton, which triggers the irreversible delocalization transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of Sequential ϒ Suppression in Au + Au Collisions at $\sqrt{s_{NN}}$ = 200 GeV with the STAR Experiment

We report on measurements of sequential ϒ suppression in Au+Au collisions at $\sqrt{s_{NN}}$ = 200 GeV with the STAR detector at the Relativistic Heavy Ion Collider (RHIC) through both the dielectron and dimuon decay channels. In the 0%–60% centrality class, the nuclear modification factors (𝑅 𝐴⁢𝐴 ), which quantify the level of yield suppression in heavy-ion collisions compared to 𝑝 + 𝑝 collisions, for ϒ⁡(1⁢𝑆) and ϒ⁡(2⁢𝑆) are 0.40 ± 0.03⁢(stat) ± 0.03⁢(sys) ± 0.09⁢(norm) and 0.26 ± 0.08⁢(stat) ± 0.02⁢(sys) ± 0.06⁢(norm), respectively, while the upper limit of the ϒ⁡(3⁢𝑆) 𝑅 𝐴⁢𝐴 is 0.17 at a 95% confidence level. This provides experimental evidence that the ϒ⁡(3⁢𝑆) is significantly more suppressed than the ϒ⁡(1⁢𝑆) at RHIC. The level of suppression for ϒ⁡(1⁢𝑆) is comparable to that observed at the much higher collision energy at the Large Hadron Collider. Furthermore, these results point to the creation of a medium at RHIC whose temperature is sufficiently high to strongly suppress excited ϒ states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Operator Relaxation and the Optimal Depth of Classical Shadows

Classical shadows are a powerful method for learning many properties of quantum states in a sample-efficient manner, by making use of randomized measurements. Here we study the sample complexity of learning the expectation value of Pauli operators via “shallow shadows,” a recently proposed version of classical shadows in which the randomization step is effected by a local unitary circuit of variable depth t. Here we show that the shadow norm (the quantity controlling the sample complexity) is expressed in terms of properties of the Heisenberg time evolution of operators under the randomizing (“twirling”) circuit—namely the evolution of the weight distribution characterizing the number of sites on which an operator acts nontrivially. For spatially contiguous Pauli operators of weight k, this entails a competition between two processes: operator spreading (whereby the support of an operator grows over time, increasing its weight) and operator relaxation (whereby the bulk of the operator develops an equilibrium density of identity operators, decreasing its weight). From this simple picture we derive (i) an upper bound on the shadow norm which, for depth t~log⁡(k), guarantees an exponential gain in sample complexity over the t=0 protocol in any spatial dimension, and (ii) quantitative results in one dimension within a mean-field approximation, including a universal subleading correction to the optimal depth, found to be in excellent agreement with infinite matrix product state numerical simulations. Our Letter connects fundamental ideas in quantum many-body dynamics to applications in quantum information science, and paves the way to highly optimized protocols for learning different properties of quantum states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Predicting Adaptively Chosen Observables in Quantum Systems

Recent advances have demonstrated that 𝒪⁡(log 𝑀) measurements suffice to predict 𝑀 properties of arbitrarily large quantum many-body systems. However, these remarkable findings assume that the properties to be predicted are chosen independently of the data. This assumption can be violated in practice, where scientists adaptively select properties after looking at previous predictions. This work investigates the adaptive setting for three classes of observables: local, Pauli, and bounded-Frobenius-norm observables. We prove that Ω⁡(√𝑀) samples of an arbitrarily large unknown quantum state are necessary to predict expectation values of 𝑀 adaptively chosen local and Pauli observables, where the system size scales exponentially and polynomially in 𝑀, respectively. We also present computationally efficient algorithms that achieve this information-theoretic lower bound. In contrast, for bounded-Frobenius-norm observables, we devise an algorithm requiring only 𝒪⁡(log 𝑀) samples, independent of system size. These results highlight the potential pitfalls of adaptivity in analyzing data from quantum experiments and provide algorithmic tools to safeguard against erroneous predictions in quantum experiments.

Machine learning↗

Leveraging Inequality-Constrained Data for Enhanced Liquidus Temperature Prediction in Nuclear Waste Glass Melts

Inequality-constrained data are frequently discarded in engineering, leading to significant information loss in data-scarce domains like glass characterization in nuclear waste vitrification. This paper presents a nonparametric censored-data regression framework based on an l1-norm optimization criterion that leverages slack variables to integrate left-, right-, and interval-constrained observations into training without distributional assumptions. Validated on synthetic data and a Physics-Informed Neural Network (PINN) for predicting liquidus temperature (TL), the method improved R2 from 0.60 to 0.89 and reduced Mean Absolute Error (MAE) by 48% (51.46 to 26.89?rC) on deterministic values. The traditional models failed to satisfy any inequality constraints while the proposed l1-norm PINN satisfies 81.25% of the constraints. The proposed framework effectively extracts actionable information from previously unusable data to enhance predictive accuracy, reduce epistemic uncertainty, and ensure physical consistency in complex industrial applications.

Garcia-Morado, Erick↗

Human-in-the-Loop Motion Control of a Two-DOF Hydraulic Backhoe Powered by the Hybrid Hydraulic Electric Architecture (HHEA)

Abstract The Hybrid Hydraulic-Electric Architecture (HHEA) combines the respective power density and control advantages of hydraulic and electric actuation to save energy for off-road vehicles. It uses a set of selectable common pressure rails to transmit the majority of power and electric actuation to modulate that power. As it is critical that off-road vehicles can perform tasks dexterously and exactly as commanded by the operator, the switchings between discrete pressure rails pose a potential challenge for smooth and precise motion. A control strategy consisting of a backstepping nominal control and least norm transition control has previously been developed to address this issue. It has been tested on 1 degree of freedom (DOF) testbeds where known trajectories were able to be tracked precisely. This paper presents the implementation of the HHEA motion control strategy on a 2-DOF backhoe operated by a human operator via a 2-DOF joystick. Unlike previous studies, the duty cycle is unknown beforehand and the decision to change pressure rails is taken in real-time. The efficacy of the motion control strategy has been validated experimentally. Several strategies to improve the user interface: control in workspace coordinates, pressure feedback, and velocity field-based task specification, have also been implemented and demonstrated to make operating the multiple DOF, HHEA actuated machine more intuitive to novice operators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distinguishing one from many using super-resolution compressive sensing

We present that distinguishing whether a signal corresponds to a single source or a limited number of highly overlapping point spread functions (PSFs) is a ubiquitous problem across all imaging scales, whether detecting receptor-ligand interactions in cells or detecting binary stars. Super-resolution imaging based upon compressed sensing exploits the relative sparseness of the point sources to successfully resolve sources which may be separated by much less than the Rayleigh criterion. However, as a solution to an underdetermined system of linear equations, compressive sensing requires the imposition of constraints which may not always be valid. One typical constraint is that the PSF is known. However, the PSF of the actual optical system may reflect aberrations not present in the theoretical ideal optical system. Even when the optics are well characterized, the actual PSF may reflect factors such as non-uniform emission of the point source (e.g. fluorophore dipole emission). As such, the actual PSF may differ from the PSF used as a constraint. Similarly, multiple different regularization constraints have been suggested including the l 1 -norm, l 0 -norm, and generalized Gaussian Markov random fields (GGMRFs), each of which imposes a different constraint. Other important factors include the signal-to-noise ratio of the point sources and whether the point sources vary in intensity. In this work, we explore how these factors influence super-resolution image recovery robustness, determining the sensitivity and specificity. In conclusion, we determine an approach that is more robust to the types of PSF errors present in actual optical systems.

42 ENGINEERING↗

Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT

Purpose: Compressed sensing theory has enabled an accurate, low-dose cone-beam computed tomography (CBCT) reconstruction using a minimal number of noisy projections. However, the reconstruction time remains a significant challenge for practical implementation in the clinic. In this work, we propose a novel gradient projection algorithm, based on the Gradient-Projection-Barzilai-Borwein formulation (GP-BB), that handles the total variation (TV)-norm regularization-based least squares problem for the CBCT reconstruction in a highly efficient manner, with speed acceptable for routine use in the clinic. Methods: CBCT is reconstructed by minimizing an energy function consisting of a data fidelity term and a TV-norm regularization term. Both terms are simultaneously minimized by calculating the gradient projection of the energy function with the step size determined using an approximate Hessian calculation at each iteration, based on the Barzilai-Borwein formulation. To speed up the process, a multiresolution optimization is used. In addition, the entire algorithm was designed to run with a single graphics processing unit (GPU) card. To evaluate the performance, the Shepp-Logan numerical phantom, the CatPhan 600 physical phantom, and a clinically-treated head-and-neck patient were acquired from the TrueBeam system (Varian Medical Systems, Palo Alto, CA). For each scan, in total, 364 projections were acquired in a 200 deg. rotation. The imager has 1024 x 768 pixels with 0.388 x 0.388-mm resolution. This was down-sampled to 512 x 384 pixels with 0.776 x 0.776-mm resolution for reconstruction. Evenly spaced angles were subsampled and used for varying the number of projections for the image reconstruction. To assess the performance of our GP-BB algorithm, we have implemented and compared with three compressed sensing-type algorithms, the two of which are popular and published (forward-backward splitting techniques), and the other one with a basic line-search technique. In addition, the conventional Feldkamp-Davis-Kress (FDK) reconstruction of the clinical patient data is compared as well. Results: In comparison with the other compressed sensing-type algorithms, our algorithm showed convergence in {<=}30 iterations whereas other published algorithms need at least 50 iterations in order to reconstruct the Shepp-Logan phantom image. With the CatPhan phantom, the GP-BB algorithm achieved a clinically-reasonable image with 40 projections in 12 iterations, in less than 12.6 s. This is at least an order of magnitude faster in reconstruction time compared with the most recent reports utilizing GPU technology given the same input projections. For the head-and-neck clinical scan, clinically-reasonable images were obtained from 120 projections in 34-78 s converging in 12-30 iterations. In this reconstruction range (i.e., 120 projections) the image quality is visually similar to or better than the conventional FDK reconstructed images using 364 projections. This represents a dose reduction of nearly 67% (120/364 projections) while maintaining a reasonable speed in clinical implementation. Conclusions: In this paper, we proposed a novel, fast, low-dose CBCT reconstruction algorithm using the Barzilai-Borwein step-size calculation. A clinically viable head-and-neck image can be obtained within {approx}34-78 s while simultaneously cutting the dose by approximately 67%. This makes our GP-BB algorithm potentially useful in an on-line image-guided radiation therapy (IGRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving IMRT delivery efficiency with reweighted L1-minimization for inverse planning

Purpose: This study presents an improved technique to further simplify the fluence-map in intensity modulated radiation therapy (IMRT) inverse planning, thereby reducing plan complexity and improving delivery efficiency, while maintaining the plan quality.Methods: First-order total-variation (TV) minimization (min.) based on L1-norm has been proposed to reduce the complexity of fluence-map in IMRT by generating sparse fluence-map variations. However, with stronger dose sparing to the critical structures, the inevitable increase in the fluence-map complexity can lead to inefficient dose delivery. Theoretically, L0-min. is the ideal solution for the sparse signal recovery problem, yet practically intractable due to its nonconvexity of the objective function. As an alternative, the authors use the iteratively reweighted L1-min. technique to incorporate the benefits of the L0-norm into the tractability of L1-min. The weight multiplied to each element is inversely related to the magnitude of the corresponding element, which is iteratively updated by the reweighting process. The proposed penalizing process combined with TV min. further improves sparsity in the fluence-map variations, hence ultimately enhancing the delivery efficiency. To validate the proposed method, this work compares three treatment plans obtained from quadratic min. (generally used in clinic IMRT), conventional TV min., and our proposed reweighted TV min. techniques, implemented by a large-scale L1-solver (template for first-order conic solver), for five patient clinical data. Criteria such as conformation number (CN), modulation index (MI), and estimated treatment time are employed to assess the relationship between the plan quality and delivery efficiency.Results: The proposed method yields simpler fluence-maps than the quadratic and conventional TV based techniques. To attain a given CN and dose sparing to the critical organs for 5 clinical cases, the proposed method reduces the number of segments by 10-15 and 30-35, relative to TV min. and quadratic min. based plans, while MIs decreases by about 20%-30% and 40%-60% over the plans by two existing techniques, respectively. With such conditions, the total treatment time of the plans obtained from our proposed method can be reduced by 12-30 s and 30-80 s mainly due to greatly shorter multileaf collimator (MLC) traveling time in IMRT step-and-shoot delivery.Conclusions: The reweighted L1-minimization technique provides a promising solution to simplify the fluence-map variations in IMRT inverse planning. It improves the delivery efficiency by reducing the entire segments and treatment time, while maintaining the plan quality in terms of target conformity and critical structure sparing.

61 RADIATION PROTECTION AND DOSIMETRY↗

The use of strain tensor to estimate thoracic tumors deformation

Purpose: Respiration-induced kinematics of thoracic tumors suggests a simple analogy with elasticity, where a strain tensor is used to characterize the volume of interests. The application of the biomechanical framework allows for the objective determination of tumor characteristics. Methods: Four-dimensional computed tomography provides the snapshots of the patient's anatomy at the end of inspiration and expiration. Image registration was used to obtain the displacement vector fields and deformation fields, which allows one for the determination of the strain tensor. Its departure from the identity matrix gauges the departure of the medium from rigidity. The tensorial characteristic of each GTV voxel was determined and averaged. To this end, the standard Euclidean matrix norm as well as the Log-Euclidean norm were employed. Tensorial anisotropy was gauged with the fractional anisotropy measure which is based on the normalized variance of the tensors eigenvalues. Anisotropy was also evaluated with the geodesic distance in the Log-Euclidean framework of a given strain tensor to its closest isotropic counterpart. Results: The averaged strain tensor was determined for each of the 15 retrospectively analyzed thoracic GTVs. The amplitude of GTV motion varied from 0.64 to 4.21 with the average of 1.20 cm. The GTV size ranged from 5.16 to 149.99 cc with the average of 43.19 cc. The tensorial analysis shows that deformation is inconsiderable and that the tensorial anisotropy is small. The Log-Euclidean distance of averaged strain tensors from the identity matrix ranged from 0.06 to 0.31 with the average of 0.19. The Frobenius distance from the identity matrix is similar and ranged from 0.06 to 0.35 with the average of 0.21. Their fractional anisotropy ranged from 0.02 to 0.12 with the average of 0.07. Their geodesic anisotropy ranged from 0.03 to 0.16 with the average of 0.09. These values also indicate insignificant deformation. Conclusions: The tensorial framework allows for direct measurements of tissue deformation. It goes beyond the evaluation of deformation via comparison of shapes. It is an independent and objective determination of tissue properties. This methodology can be used to determine possible changes in lung properties due to radiation therapy and possible toxicities.

60 APPLIED LIFE SCIENCES↗

MO-G-17A-07: Improved Image Quality in Brain F-18 FDG PET Using Penalized-Likelihood Image Reconstruction Via a Generalized Preconditioned Alternating Projection Algorithm: The First Patient Results

Purpose: To investigate the performance of a new penalized-likelihood PET image reconstruction algorithm using the 1{sub 1}-norm total-variation (TV) sum of the 1st through 4th-order gradients as the penalty. Simulated and brain patient data sets were analyzed. Methods: This work represents an extension of the preconditioned alternating projection algorithm (PAPA) for emission-computed tomography. In this new generalized algorithm (GPAPA), the penalty term is expanded to allow multiple components, in this case the sum of the 1st to 4th order gradients, to reduce artificial piece-wise constant regions (“staircase” artifacts typical for TV) seen in PAPA images penalized with only the 1st order gradient. Simulated data were used to test for “staircase” artifacts and to optimize the penalty hyper-parameter in the root-mean-squared error (RMSE) sense. Patient FDG brain scans were acquired on a GE D690 PET/CT (370 MBq at 1-hour post-injection for 10 minutes) in time-of-flight mode and in all cases were reconstructed using resolution recovery projectors. GPAPA images were compared PAPA and RMSE-optimally filtered OSEM (fully converged) in simulations and to clinical OSEM reconstructions (3 iterations, 32 subsets) with 2.6 mm XYGaussian and standard 3-point axial smoothing post-filters. Results: The results from the simulated data show a significant reduction in the 'staircase' artifact for GPAPA compared to PAPA and lower RMSE (up to 35%) compared to optimally filtered OSEM. A simple power-law relationship between the RMSE-optimal hyper-parameters and the noise equivalent counts (NEC) per voxel is revealed. Qualitatively, the patient images appear much sharper and with less noise than standard clinical images. The convergence rate is similar to OSEM. Conclusions: GPAPA reconstructions using the 1{sub 1}-norm total-variation sum of the 1st through 4th-order gradients as the penalty show great promise for the improvement of image quality over that currently achieved with clinical OSEM reconstructions.

60 APPLIED LIFE SCIENCES↗

WE-G-17A-01: Improving Tracking Image Spatial Resolution for Onboard MR Image Guided Radiation Therapy Using the WHISKEE Technique

Purpose: To evaluate the feasibility of using the weighted hybrid iterative spiral k-space encoded estimation (WHISKEE) technique to improve spatial resolution of tracking images for onboard MR image guided radiation therapy (MR-IGRT). Methods: MR tracking images of abdomen and pelvis had been acquired from healthy volunteers using the ViewRay onboard MRIGRT system (ViewRay Inc. Oakwood Village, OH) at a spatial resolution of 2.0mm*2.0mm*5.0mm. The tracking MR images were acquired using the TrueFISP sequence. The temporal resolution had to be traded off to 2 frames per second (FPS) to achieve the 2.0mm in-plane spatial resolution. All MR images were imported into the MATLAB software. K-space data were synthesized through the Fourier Transform of the MR images. A mask was created to selected k-space points that corresponded to the under-sampled spiral k-space trajectory with an acceleration (or undersampling) factor of 3. The mask was applied to the fully sampled k-space data to synthesize the undersampled k-space data. The WHISKEE method was applied to the synthesized undersampled k-space data to reconstructed tracking MR images at 6 FPS. As a comparison, the undersampled k-space data were also reconstructed using the zero-padding technique. The reconstructed images were compared to the original image. The relatively reconstruction error was evaluated using the percentage of the norm of the differential image over the norm of the original image. Results: Compared to the zero-padding technique, the WHISKEE method was able to reconstruct MR images with better image quality. It significantly reduced the relative reconstruction error from 39.5% to 3.1% for the pelvis image and from 41.5% to 4.6% for the abdomen image at an acceleration factor of 3. Conclusion: We demonstrated that it was possible to use the WHISKEE method to expedite MR image acquisition for onboard MR-IGRT systems to achieve good spatial and temporal resolutions simultaneously. Y. Hu and O. green receive travel reimbursement from ViewRay. S. Mutic has consulting and research agreements with ViewRay. Q. Zeng, R. Nana, J.L. Patrick, S. Shvartsman and J.F. Dempsey are ViewRay employees.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of pulse duration on magnetostimulation thresholds

Purpose: Medical imaging techniques such as magnetic resonance imaging and magnetic particle imaging (MPI) utilize time-varying magnetic fields that are subject to magnetostimulation limits, which often limit the speed of the imaging process. Various human-subject experiments have studied the amplitude and frequency dependence of these thresholds for gradient or homogeneous magnetic fields. Another contributing factor was shown to be number of cycles in a magnetic pulse, where the thresholds decreased with longer pulses. The latter result was demonstrated on two subjects only, at a single frequency of 1.27 kHz. Hence, whether the observed effect was due to the number of cycles or due to the pulse duration was not specified. In addition, a gradient-type field was utilized; hence, whether the same phenomenon applies to homogeneous magnetic fields remained unknown. Here, the authors investigate the pulse duration dependence of magnetostimulation limits for a 20-fold range of frequencies using homogeneous magnetic fields, such as the ones used for the drive field in MPI. Methods: Magnetostimulation thresholds were measured in the arms of six healthy subjects (age: 27 ± 5 yr). Each experiment comprised testing the thresholds at eight different pulse durations between 2 and 125 ms at a single frequency, which took approximately 30–40 min/subject. A total of 34 experiments were performed at three different frequencies: 1.2, 5.7, and 25.5 kHz. A solenoid coil providing homogeneous magnetic field was used to induce stimulation, and the field amplitude was measured in real time. A pre-emphasis based pulse shaping method was employed to accurately control the pulse durations. Subjects reported stimulation via a mouse click whenever they felt a twitching/tingling sensation. A sigmoid function was fitted to the subject responses to find the threshold at a specific frequency and duration, and the whole procedure was repeated at all relevant frequencies and pulse durations. Results: The magnetostimulation limits decreased with increasing pulse duration (T{sub pulse}). For T{sub pulse} < 18 ms, the thresholds were significantly higher than at the longest pulse durations (p < 0.01, paired Wilcoxon signed-rank test). The normalized magnetostimulation threshold (B{sub Norm}) vs duration curve at all three frequencies agreed almost identically, indicating that the observed effect is independent of the operating frequency. At the shortest pulse duration (T{sub pulse} ≈ 2 ms), the thresholds were approximately 24% higher than at the asymptotes. The thresholds decreased to within 4% of their asymptotic values for T{sub pulse} > 20 ms. These trends were well characterized (R{sup 2} = 0.78) by a stretched exponential function given by B{sub Norm}=1+αe{sup −(T{sub p}{sub u}{sub l}{sub s}{sub e}/β){sup γ}}, where the fitted parameters were α = 0.44, β = 4.32, and γ = 0.60. Conclusions: This work shows for the first time that the magnetostimulation thresholds decrease with increasing pulse duration, and that this effect is independent of the operating frequency. Normalized threshold vs duration trends are almost identical for a 20-fold range of frequencies: the thresholds are significantly higher at short pulse durations and settle to within 4% of their asymptotic values for durations longer than 20 ms. These results emphasize the importance of matching the human-subject experiments to the imaging conditions of a particular setup. Knowing the dependence of the safety limits to all contributing factors is critical for increasing the time-efficiency of imaging systems that utilize time-varying magnetic fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗