Search NASA⌕ Search

SEARCH · Search NASA

Results for “Net load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Colorado Residential Retrofit Energy District (CoRRED) Phase I: Final Modeling Results

Electrification of buildings and transportation coupled with increased deployment of distributed energy resources (DERs) has been identified as a key step toward meeting emissions reduction goals across the U.S. Examples of pilot projects that feature innovative, 'smart' electric neighborhoods are largely focused on new construction projects, but there is a need to address the millions of existing homes so that they too may accommodate cleaner yet variable energy production in ways that benefit both the utility grid and the homes' residents. The Colorado Residential Retrofit Energy District (CoRRED) project used building and grid co-simulation tools to model an advanced energy district demonstration in an existing residential neighborhood in Denver, Colorado, and explored how existing building and utility infrastructures can be enhanced with combinations of traditional energy-efficiency retrofit measures and integration of solar panels and other DER technologies to provide better affordability and reliability. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate. Our results clearly indicate that incorporating DERs into efficient electrification produces much bigger utility bill savings on an annual basis than efficient electrification without DERs. While electrifying a neighborhood will increase the maximum load, batteries and solar panels can reduce load during peak hours so that the community can be a net producer during peak periods. A remaining challenge is to overcome first cost barriers to implementing energy-efficiency and DER technologies, as modest utility bill savings require long payback periods that are not practical for most homeowners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power and Wind Shear Implications of Large Wind Turbine Scenarios in the US Central Plains

Continued growth of wind turbine physical dimensions is examined in terms of the implications for wind speed, power and shear across the rotor plane. High-resolution simulations with the Weather Research and Forecasting model are used to generate statistics of wind speed profiles for scenarios of current and future wind turbines. The nine-month simulations, focused on the eastern Central Plains, show that the power scales broadly as expected with the increase in rotor diameter (D) and wind speeds at hub-height (H). Increasing wind turbine dimensions from current values (approximately H = 100 m, D = 100 m) to those of the new International Energy Agency reference wind turbine (H = 150 m, D = 240 m), the power across the rotor plane increases 7.1 times. The mean domain-wide wind shear exponent (α) decreases from 0.21 (H = 100 m, D = 100 m) to 0.19 for the largest wind turbine scenario considered (H = 168 m, D = 248 m) and the frequency of extreme positive shear (α > 0.2) declines from 48% to 38% of 10-min periods. Thus, deployment of larger wind turbines potentially yields considerable net benefits for both the wind resource and reductions in fatigue loading related to vertical shear.

17 WIND ENERGY↗

Impact of Miller Cycle Strategies on Combustion Characteristics, Emissions and Efficiency in Heavy-Duty Diesel Engines

This study experimentally investigated the potential of Miller cycle strategies as a means to improve fuel consumption and reduce NO x emissions in heavy-duty diesel engines. The experiments were conducted at constant engine speed, load, and engine-out NO x (1160 rev/min, 1.76 MPa net IMEP, 4.5 g/kWh) on a single cylinder research engine equipped with a fully-flexible hydraulic valve train system. Early Intake Valve Closing (EIVC) and Late Intake Valve Closing (LIVC) timing strategies were compared to a conventional intake valve profile. While the decrease in effective compression ratio associated with the use of Miller valve profiles was symmetric around bottom dead center, the decrease in volumetric efficiency (VE) was not. EIVC profiles were more effective at reducing VE than LIVC profiles. Despite this difference, EIVC and LIVC profiles with comparable VE decrease resulted in similar changes in combustion and emissions characteristics. Miller cycle operation at constant intake pressure resulted in lower peak cylinder pressure, higher exhaust temperatures and lower EGR requirements compared to the baseline case, albeit with a significant fuel consumption penalty. Increasing intake manifold pressure to match the baseline air-fuel ratio overcame the fuel consumption penalty, without compromising NO x emissions. Selected EIVC/LIVC profiles were compared to the baseline condition at three different overall turbocharger efficiencies (n TC ). At the baseline n TC , Miller cycle profiles can lower peak cylinder pressures and increase exhaust temperatures with a minimal penalty in BSFC and FSN. At higher n TC than baseline, Miller cycle can maintain the benefits of lower peak cylinder pressure and higher exhaust temperature without a BSFC or FSN penalty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case Study: Hybrid Carbon Conversion Using Low-Carbon Energy Sources in Coal-Producing States

The demand for more carbon efficient power sources and a decrease in natural gas prices has decreased the desire for coal power. This decrease in demand has led to massive job losses in coal mining regions over the past decade. The purpose of this project is to develop a hybrid energy system utilizing both a coal power plant and advanced reactor, which is competitive with natural gas by improving on profitability and decreasing carbon emissions. This report details the problem with a summary of the impact on the coal industry and the availability of renewable energy sources in the Appalachian region. Because of the geography of the region, variable renewable energy sources are not available without significant size and siting restrictions. However, biomass in the form of wood waste is abundant and can be used as a carbon neutral energy source. Combining biomass and coal processing, in addition to thermal power plants, can increase system profits and efficiency by providing peaking power and conversion opportunities for secondary markets. The electric load is based on publicly available demand data from Appalachian Power, which services the western Virginia and southern West Virginia in the Appalachian region. The demand information is combined by service, normalized, and scaled to an average demand of 1000 kW, which will be the basis for sizing the hybrid energy system. A traditional screening curve analysis for a coal plant and advanced reactor shows that the least cost design varies significantly based on the assumed discount rate and capital recovery period. An optimization program to size the design in TEAL based on the load curve gives 10 optimal designs, all with a negative resulting net present value (NPV) and a coal plant capacity of less than 15%. Including profits from selling captured carbon at a flat rate results in a positive NPV; however, the coal capacity factor only increases to about 40%. There are limitations with this optimization as well since the price of CO2 is likely to decrease as more is sold to the conversion market. The suggested design will combine coal power, an advanced reactor, and coal and biomass coprocessing to produce a variety of products that can be sold to the conversion market while increasing system efficiency. The analysis of conversion pathways for coal and biomass reveals that multiple options will need to be included in the analysis to produce the optimal system design. Three systems will be optimized and compared to determine the best design based on the figures of merit of total NPV and cost of carbon avoided. The first system will include a coal power plant and an advanced reactor that will sell electricity to the grid to meet demand and sell captured carbon to the conversion market. The second system adds a high-temperature steam electrolysis plant, which will utilize electricity during times of low demand to produce hydrogen and sell it to the conversion market. The third system adds biomass and coal processing with options for hydrocarbon oils, syngas to be produced for the conversion market, and electricity generation to power components within the system or provide peaking power. This analysis will be based on a new approach that combines traditional screening curve methods with a dispatch algorithm that optimizes the system based on the opportunity cost of different production options. The resulting optimization algorithm should provide results with less processing time than HERON’s decision tree method. The results from this analysis will determine an optimal design and reinforce the benefits of coal power when used in a hybrid energy system. The initial results show that the addition of a secondary market for carbon sales could result in a positive NPV and increases the capacity factor of the coal plant as compared to a design with only sales to the electricity market. The addition of more markets and additional coal consumption from biomass coprocessing could increase NPV further, replace carbon in other markets through the sale of biomass-derived hydrocarbons, and demonstrate the value of coal power technology.

01 COAL, LIGNITE, AND PEAT↗

Effects of Radiative Heat Transfer in High-Temperature Liquid-Salts

Recent technological advances and needs for high-temperature heat have increased interest in nuclear power systems that utilize liquid-salts such as Fluoride-salt-cooled High-temperature Reactors (FHR), Molten Salt Reactors (MSR), and high-magnetic-field fusion machines with immersion salt coolant blankets. These systems can be used to provide high-temperature heat to high carbon-emitting industrial processes such as oil refining, hydrogen production, and shale oil recovery. Additionally, improved gas turbine technology has made coupling high-temperature reactors to Nuclear Air-Brayton Combined Cycles possible. This allows for both base-load and peak electricity production that can increase system efficiency and net revenue. New fusion reactor designs with increased power density and smaller sizes can also benefit from liquid salt blankets to produce tritium while providing neutron and gamma shielding to high-field magnets. These applications when combined with enhancements in safety, fuel cycle, and cost make liquid-salt reactors an attractive option for new nuclear power systems. However, despite successful experiments such as the Molten Salt Reactor Experiment, the limited experience with liquid-salt coolants leaves unanswered questions. Understanding of the thermal hydraulic and heat transfer performance of these salts needs to be improved, especially in the area of radiative heat transfer. Liquid salt systems have typical operating temperatures between 600 and 700 deg. C. Because thermal radiation scales approximately as T4, its effects begin to become important in this temperature range. Under higher-temperature off-normal conditions radiative heat transfer can become a major mechanism of heat transfer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multiscale Effects Masked the Impact of the COVID-19 Pandemic on Electricity Demand in the United States

Shelter-in-place orders and business closures related to COVID-19 changed the hourly profile of electricity demand and created an unprecedented source of uncertainty for the grid. The potential for continued shifts in electricity profiles has implications for electricity sector investment and operating decisions that maintain reserve margins and provide grid reliability. This study reveals that understanding this uncertainty requires an understanding of the underlying drivers at the customer-class scale. This paper utilizes three datasets to compare the impacts of COVID-19 on electricity consumption across a range of spatiotemporal and customer scales. At the utility/customer-class scale, COVID-19-induced shutdowns in the spring of 2020 shifted weekday residential load profiles to resemble weekend profiles from previous years. Total commercial loads declined, but the commercial diurnal load profile was unchanged. With only total loads available at the balancing authority scale, the apparent impact of COVID-19 was smaller during the summer due in part to phased re-opening and spatial variability in re-opening, but there were still clear variations once total loads were broken down zonally. Monthly data at the state scale showed an increase in state-level residential electricity sales, a decrease in commercial sales, and a small net decrease in total sales in most states from April-August 2020. Analyses that focus on total load or a single scale may miss important changes that become apparent when the load is broken down regionally or by customer class.

COVID-19, electricity demand, multiscale, Commonwe↗

Advanced CO 2 Capture Solvent Systems for Dynamic Power Generation

RTI International, in collaboration with Pacific Northwest National Laboratory (PNNL), Carbon Capture Simulation for Industry Impact (CCSI 2 ), Electricity Power Research Institute (EPRI), and West Virginia University (WVU), successfully completed a joint research effort in developing a cost-effective, resilient, load-following advanced CO 2 capture technology for natural gas power plants. The project’s objective was to develop a CO 2 capture process that maximizes the net present value (NPV) of the electricity sale by minimizing the levelized cost of electricity (LCOE) under dynamic plant loads and high renewable penetration environments. The two key innovations developed in this project were the use of (i) advanced water-lean solvents (WLSs) and (ii) process intensification equipment, such as a rotating packed bed (RPB) absorber and dual-stage flash regeneration. The process’s low CO 2 capture cost is realized through WLSs’ low energy required for solvent regeneration, which lowers the operating cost while RPBs intensify the absorption process and reduces the power plant capital cost. A suite of advanced computational and simulation packages was implemented to guide the process design, validate the dynamic response of the capture plant, evaluate system-wide performance, and maximize the power plant’s profit. The project also engaged with power producers and other stakeholders to ensure its technical relevance and techno-economic viability. The development of this highly disruptive CO 2 capture technology could accelerate the industry adoption and thereby lower the greenhouse gas emissions of the U.S. power sector. Deployment of this technology can increase the reliability and decrease the cost of electricity generation in the U.S. by enabling the use of low-carbon fossil fuels to balance fluctuations of renewable energy availability.

03 NATURAL GAS↗

Getting to Net Zero

The technology necessary to build net zero energy buildings (NZEBs) is ready and available today, however, building to net zero energy performance levels can be challenging. Energy efficiency measures, onsite energy generation resources, load matching and grid interaction, climatic factors, and local policies vary from location to location and require unique methods of constructing NZEBs. It is recommended that Components start looking into how to construct and operate NZEBs now as there is a learning curve to net zero construction and FY 2020 is just around the corner.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimization and life-cycle cost of health clinic PV system for a rural area in southern Iraq using HOMER software

This paper addresses the need for electricity of rural areas in southern Iraq and proposes a photovoltaic (PV) solar system to power a health clinic in that region. The total daily health clinic load is 31.6 kW h and detailed loads are listed. The National Renewable Energy Laboratory (NREL) optimization computer model for distributed power, ''HOMER,'' is used to estimate the system size and its life-cycle cost. The analysis shows that the optimal system's initial cost, net present cost, and electricity cost is US$ 50,700, US$ 60,375, and US$ 0.238/kW h, respectively. These values for the PV system are compared with those of a generator alone used to supply the load. We found that the initial cost, net present cost of the generator system, and electricity cost are US$ 4500, US$ 352,303, and US$ 1.332/kW h, respectively. We conclude that using the PV system is justified on humanitarian, technical, and economic grounds. (author)

14 SOLAR ENERGY↗

The impact of retail rate structures on the economics of commercial photovoltaic systems in California

This article examines the impact of retail electricity rate design on the economic value of grid-connected photovoltaic (PV) systems, focusing on commercial customers in California. Using 15-min interval building load and PV production data from a sample of 24 actual commercial PV installations, we compare the value of the bill savings across 20 commercial-customer retail electricity rates currently offered in the state. Across all combinations of customers and rates, we find that the annual bill savings from PV, per kWh generated, ranges from $0.05 to $0.24/kWh. This sizable range in rate-reduction value reflects differences in rate structures, revenue requirements, the size of the PV system relative to building load, and customer load shape. The most significant rate design issue for the value of commercial PV is found to be the percentage of total utility bills recovered through demand charges, though a variety of other factors are also found to be of importance. The value of net metering is found to be substantial, but only when energy from commercial PV systems represents a sizable portion of annual customer load. Though the analysis presented here is specific to California, our general results demonstrate the fundamental importance of retail rate design for the customer-economics of grid-connected, customer-sited PV.

14 SOLAR ENERGY↗

Supervisory Control of Loads and Energy Storage in Next-Generation Zero Energy Buildings

A zero energy building (ZEB)—also known as a net zero energy or zero net energy building—is a building that exports as much renewable energy as the total energy it imports from other sources on an annual basis (DOE 2015). Large-scale and commercially viable ZEBs are now in the marketplace, and they are expected to become a larger share of the commercial building footprint as government and private sector policies continue to promote the development of buildings that produce more on-site energy than they use. However, the load profiles of ZEBs are currently perceived by electric utilities to be unfavorable and unpredictable. As shown in Figure ES-1, ZEB load profiles can have abrupt changes in magnitude, at times switching rapidly between exporting and importing electricity. This is a challenge for utilities, which are responsible for constantly balancing electricity supply and demand across the grid. Addressing these concerns will require new strategies and tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SUPERLUMINAL WAVES IN PULSAR WINDS

The energy lost by a rotation-powered pulsar is carried by a relativistic flow containing a mixture of electromagnetic fields and particles. In the inner regions, this is thought to be a magnetically dominated, cold, electron-positron wind that is well described by the MHD equations. However, beyond a critical radius r{sub cr}, the same particle, energy, and momentum fluxes can be transported by a strong, transverse electromagnetic wave with superluminal phase speed. We analyze the nonlinear dispersion relation of these waves for linear and circular polarization, and find the dependence of r{sub cr} on the mass-loading, magnetization, and luminosity of the flow, as well as on the net magnetic flux. We show that, for most isolated pulsars, the wind lies well outside r{sub cr} and speculate that superluminal modes play an important role in the dissipation of electromagnetic energy into nonthermal particles at the termination shock.

79 ASTRONOMY AND ASTROPHYSICS↗

NREL RSF Measured Data 2011

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance. This submission includes the Measured Energy Data from the RSF Systems Model. The data includes a csv with measured data from NREL's Research and Support Facility (RSF) for 2011. The dataset contains hourly data for: Total Cooling (kW)- Total Heating (kW)- Total Mechanical (kW)- Total Lighting (kW)- Total Plug Loads (kW)- Total Data Center (kW)- Total Building (kW)- PV (kW)- Building Net (kW). Energy Model data and Weather data related to the RSF Systems Model can be found in the "Related Datasets" section of this submission.

2011↗

Updating PV and Battery Bill Savings Calculations for Net Billing: New Best Practices for Input Data and Uncertainty

Jurisdictions are increasingly adopting compensation structures for distributed PV and PV-battery systems that price exported energy lower than energy consumed onsite (net billing rates). Standard methods for calculating the bill savings from PV and PV-battery systems were developed for net metering structures, and applying these same methods to net billing structures (such as using Typical Meteorological Year weather with actual year load) introduces bias errors that underestimate PV-battery system bill savings by between 1.5\% and 9\%, depending on the utility rate. We assess the magnitude of these errors and compare them to other sources of uncertainty when estimating the bill savings from PV and PV-battery systems under more complex utility rates.

14 SOLAR ENERGY↗

A novel methodology for assessing the hygroscopicity of aerosol filter samples

Abstract. Due to US regulations, concentrations of hygroscopic inorganic sulfate and nitrate have declined in recent years, leading to an increased importance of the hygroscopic nature of organic matter (OM). The hygroscopicity of OM is poorly characterized because only a fraction of the multitude of organic compounds in the atmosphere is readily measured, and there is limited information on their hygroscopic behaviors. Hygroscopicity of aerosol is traditionally measured using a humidified tandem differential mobility analyzer (HTDMA) or electrodynamic balance (EDB). EDB measures water uptake by a single particle. For ambient and chamber studies, HTDMA measurements provide water uptake and particle size information but not chemical composition. To fill this information gap, we developed a novel methodology to assess the water uptake by particles collected on Teflon filters. This method uses the same filter sample for both hygroscopicity measurements and chemical characterization, thereby providing an opportunity to link the measured hygroscopicity with ambient particle composition. To test the method, hygroscopic measurements were conducted in the laboratory for ammonium sulfate, sodium chloride, glucose, and malonic acid, which were collected on 25 mm Teflon filters using an aerosol generator and sampler. Constant-humidity solutions (CHSs), including potassium chloride, barium chloride dihydrate, and potassium sulfate, were employed in a saturated form to maintain the relative humidity (RH) at approximately 84 %, 90 %, and 97 % in small chambers. Our preliminary experiments revealed that, without the pouch, water uptake measurements were not feasible due to rapid water loss during weighing. Additionally, we observed some absorption by the aluminum pouch itself. To account for this, concurrent measurements were conducted for both the loaded and the blank filters at each RH level. Thus, the dry loaded and blank Teflon filters were placed in aluminum pouches with one side open and in RH-controlled chambers for more than 24 h. The wet loaded samples and wet blanks were then weighed using an ultramicrobalance to determine the water uptake by the respective compound and the blank Teflon filter. The net amount of water absorbed by each compound was calculated by subtracting the water uptake of the blank filter from that of the wet loaded filter. Hygroscopic parameters, including the water-to-solute (W / S) ratio, molality, mass fraction solute (mfs), and growth factors (GFs), were calculated from the measurements. The results obtained are consistent with those reported by the Extended Aerosol Inorganics Model (E-AIM) and previous studies utilizing HTDMA and EDB for these compounds, highlighting the accuracy of this new methodology. This new approach enables the hygroscopicity and chemical composition of individual filter samples to be assessed so that in complex mixtures, such as chamber and ambient samples, the total water uptake can be parsed between the inorganic and organic components of the aerosol.

54 ENVIRONMENTAL SCIENCES↗

Techno-Economic Assessment of Data Center Load Demand Powered by Small Modular Reactors and Distributed Energy Resources

The rapid increase in data center energy demand, driven by AI and large-scale data processing, poses significant challenges to global energy infrastructure. Data centers require substantial and reliable energy for continuous operations and high-performance computing. Current electrical grids face issues such as transmission bottlenecks and aging infrastructure, making it difficult to meet these demands. Integrating inverter-based-resources (IBRs) like solar and wind presents both opportunities and challenges due to their intermittent nature. Small Modular Reactors (SMRs) offer a promising solution with their enhanced safety, modularity, reliability, and scalability, providing consistent base load power ideal for data center operations. This study presents a comprehensive techno-economic assessment of powering data center load demand using a combination of SMRs and IBRs with grid-connected and islanded mode. This study utilized Idaho National Laboratory’s (INL) HPC data center hourly load profiles and Xendee microgrid optimization platform to conduct the analysis. In this configuration, SMRs serves as the primary base load power source, consistently providing a steady supply of electricity necessary to meet the minimum load demand of the data center with support from the IBRs. Key performance indicators such as Levelized Cost of Electricity (LCOE), Net Present Value (NPV) has been calculated to assess the economic feasibility. The findings from this research will underscore the strategic benefits of integrating SMR plant with DERs – particularly for critical infrastructure load such as data centers.

14 - SOLAR ENERGY↗

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Slot-die-coating operability windows for polymer electrolyte membrane fuel cell cathode catalyst layers

Roll-to-roll (R2R) slot-die coating of polymer electrolyte membrane fuel cell (PEMFC) catalyst layers represents a scalable deposition method for producing 10–20 m 2 ·min -1 of catalyst-coated gas diffusion layers (GDLs). This high-throughput production technique will help lower the cost of PEMFC catalyst layers. The uniformity of the wet layer applied by slot die deposition is affected by process parameters such as substrate speed, vacuum pressure applied at the upstream meniscus, gap between the slot die lips and substrate, ink rheology, and other ink and substrate properties. The set of conditions for producing a defect-free coating with a dilute ink typically requires little to no upstream vacuum pressure, so suitable operating conditions can be found easily through trial and error and operator intuition. However, the higher viscosity of more concentrated inks dramatically shifts the range of settings that result in a homogeneous coating to higher vacuum levels, which are harder to find through hit or miss. A predictive model showing the range of operable conditions decreases material wastage inherent in experimentally searching for suitable parameters. In this study, the defect-free coating parameter window is explored experimentally and theoretically for two concentrations of PEFC cathode inks. Both a full capillary hydrodynamic model and a computationally cheaper viscocapillary model successfully predict the experimentally determined coating window within the experimental and model uncertainty limits for inks with 5.3 wt% and 12.0 wt% solids ink while maintaining the 0.1 mg Pt ·cm -2 Pt areal loading target. Here, this paper demonstrates a viable pathway for meeting the $30/kW net ultimate cost target of the United States Department of Energy (U.S. DOE) Hydrogen Fuel Cells Technologies Office (HFTO). The concentrated ink lowers the thermal energy and capital expenditure (CapEx) budget of the coating process by decreasing the amount of time, energy, and floorspace required for drying the coating.

25 ENERGY STORAGE↗