Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Yield”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Concept of DT fuel cycle for a fusion neutron source

A concept of DT-fusion neutron source (FNS) with the neutron yield higher than 10{sup 18} neutrons per second is under design in Russia. Such a FNS is of interest for many applications: 1) basic and applied research (neutron scattering, etc); 2) testing the structural materials for fusion reactors; 3) control of sub-critical nuclear systems and 4) nuclear waste processing (including transmutation of minor actinides). This paper describes the fuel cycle concept of a compact fusion neutron source based on a small spherical tokamak (FNS-ST) with a MW range of DT fusion power and considers the key physics issues of this device. The major and minor radii are ∼0.5 and ∼0.3 m, magnetic field ∼1.5 T, heating power less than 15 MW and plasma current 1-2 MA. The system provides the fuel mixture with equal fractions of D and T (D:T = 1:1) for all FNS technology systems. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Demonstration of thermonuclear conditions in magnetized liner inertial fusion experiments

The magnetized liner inertial fusion concept [S. A. Slutz et al., Phys. Plasmas 17, 056303 (2010)] utilizes a magnetic field and laser heating to relax the pressure requirements of inertial confinement fusion. The first experiments to test the concept [M. R. Gomez et al., Phys. Rev. Lett. 113, 155003 (2014)] were conducted utilizing the 19 MA, 100 ns Z machine, the 2.5 kJ, 1 TW Z Beamlet laser, and the 10 T Applied B-field on Z system. Despite an estimated implosion velocity of only 70 km/s in these experiments, electron and ion temperatures at stagnation were as high as 3 keV, and thermonuclear deuterium-deuterium neutron yields up to 2 × 10{sup 12} have been produced. X-ray emission from the fuel at stagnation had widths ranging from 50 to 110 μm over a roughly 80% of the axial extent of the target (6–8 mm) and lasted approximately 2 ns. X-ray yields from these experiments are consistent with a stagnation density of the hot fuel equal to 0.2–0.4 g/cm{sup 3}. In these experiments, up to 5 × 10{sup 10} secondary deuterium-tritium neutrons were produced. Given that the areal density of the plasma was approximately 1–2 mg/cm{sup 2}, this indicates the stagnation plasma was significantly magnetized, which is consistent with the anisotropy observed in the deuterium-tritium neutron spectra. Control experiments where the laser and/or magnetic field were not utilized failed to produce stagnation temperatures greater than 1 keV and primary deuterium-deuterium yields greater than 10{sup 10}. An additional control experiment where the fuel contained a sufficient dopant fraction to substantially increase radiative losses also failed to produce a relevant stagnation temperature. The results of these experiments are consistent with a thermonuclear neutron source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimating uncertainty of inference for validation

We present a validation process based upon the concept that validation is an inference-making activity. This has always been true, but the association has not been as important before as it is now. Previously, theory had been confirmed by more data, and predictions were possible based on data. The process today is to infer from theory to code and from code to prediction, making the role of prediction somewhat automatic, and a machine function. Validation is defined as determining the degree to which a model and code is an accurate representation of experimental test data. Imbedded in validation is the intention to use the computer code to predict. To predict is to accept the conclusion that an observable final state will manifest; therefore, prediction is an inference whose goodness relies on the validity of the code. Quantifying the uncertainty of a prediction amounts to quantifying the uncertainty of validation, and this involves the characterization of uncertainties inherent in theory/models/codes and the corresponding data. An introduction to inference making and its associated uncertainty is provided as a foundation for the validation problem. A mathematical construction for estimating the uncertainty in the validation inference is then presented, including a possibility distribution constructed to represent the inference uncertainty for validation under uncertainty. The estimation of inference uncertainty for validation is illustrated using data and calculations from Inertial Confinement Fusion (ICF). The ICF measurements of neutron yield and ion temperature were obtained for direct-drive inertial fusion capsules at the Omega laser facility. The glass capsules, containing the fusion gas, were systematically selected with the intent of establishing a reproducible baseline of high-yield 10{sup 13}-10{sup 14} neutron output. The deuterium-tritium ratio in these experiments was varied to study its influence upon yield. This paper on validation inference is the first in a series of inference uncertainty estimations. While the methods demonstrated are primarily statistical, these do not preclude the use of nonprobabilistic methods for uncertainty characterization. The methods presented permit accurate determinations for validation and eventual prediction. It is a goal that these methods establish a standard against which best practice may evolve for determining degree of validation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using neutrons to measure keV temperatures in highly compressed plastic at multi-Gbar pressures

In this study, we have designed an experiment for the National Ignition Facility to measure the Hugoniot of materials such as plastic at extreme pressures. The design employs a strong spherically converging shock launched through a solid ball of material using a hohlraum radiation drive. The shock front conditions can be characterized using X-ray radiography until background from shock coalescence overtakes the backlit signal. Shock coalescence at the center is predicted to reach tens of Gbars and can be further characterized by measuring the X-ray self-emission and 2.45 MeV neutrons emitted from the shock flash region. In this simulation design work the standard plastic sphere is replaced with a deuterated polyethylene sphere, CD 2 , that reaches sufficiently high densities and temperatures in the central hot spot to produce neutrons from Deuterium-Deuterium (DD) fusion reactions that can be measured by a neutron time of flight spectrometer (nTOF) and act as a temperature diagnostic. This paper focuses on the design of these experiments, based on an extensive suite of radiation-hydrodynamics simulations, and the interpretation of the predicted DD neutron signals. The simulations predict mean temperatures of 1 keV in the central hot spot with mean densities of 33 g/cc and mean pressures of 25 Gbar. Lastly, a preliminary comparison with early experimental results looks promising with an average ion temperature of 1.06 ± 0.15 keV in the central hot spot estimated from the nTOF spectral width and measured neutron yield of 7.0 (±0.5) × 10 9 DD neutrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using neutrons and x rays to measure plasma conditions in a solid sphere of deuterated polyethylene compressed to densities of 35 g/cc at temperatures of 2 keV and pressures of 40 Gbar

This paper describes an experiment that shock compresses the center of a solid deuterated polyethylene sphere, CD 2 , to densities of 35 g/cc and temperatures of 2 keV with corresponding pressure of 40 Gbar. The design employs a strong spherically converging shock launched through a solid ball of material using a Hohlraum radiation drive. As the shock coalesces at the center it produces a hot spot that we characterize by measuring the x-ray self-emission and 2.45 MeV neutrons emitted. Two-dimensional images and time-resolved measurements of the x rays emitted determine the size and time duration of the hot spot, leading to an estimated 2k eV electron temperature. The neutron time of flight spectrometer measures an average ion temperature of 1.06 ± 0.15 keV and neutron yield of 7.0 (±0.5) × 10 9 DD neutrons. Our new distribution function tool enables us to create a forward model of the experimental data based on 1D radiation-hydrodynamic simulations, leading to a better understanding of the plasma conditions that produce the measured neutrons and x rays. Furthermore, our simulations indicate that the x rays are produced in a short-lived hot-dense core over tens of picoseconds, whereas the neutron emission continues for about 200 ps, as the hot core starts to expand, thereby leading to a lower mean temperature of the plasma during neutron production. This finding is in agreement with the experimental data, and we therefore conclude that the forward-modeling is a useful tool for inferring the conditions of the hot spot in a laser-driven implosion during burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Versatile D-T Neutron-Generation System for Fast-Neutron Research and Education

In order to stimulate new cutting-edge research and create novel educational tools at the Pennsylvania State University (PSU), the PIs of the project acquired a versatile 14-MeV D-T neutron-generation system. Relatively recent advancements at Lawrence Berkeley National Laboratory (LBNL) have led to the development of high-neutron-output D-T neutron generators. The resulting technology was subsequently licensed to Adelphi Technology, Inc. and 14-MeV D-T neutron-generation systems are currently available with neutron yields up to 10 10 n/sec. Such neutron output has been available previously; however, the existing D-T generators were traditionally million-dollar systems (an example is D711 from Thermo Scientific), thus beyond reach for many users. The Adelphi neutron generators, on the other hand, now provide access to high neutron outputs for a reasonable price. More importantly, the expected lifetime of the D-T system’s tubes is at least 2,000 hours; a factor of two better when compared to D711, with comparable generator-tube replacement cost. Adelphi Technology, the manufacturer of the dual D-T neutron generation system, delivered one 10 8 neutrons/second and one 10 10 neutrons/second D-T generator with two separate control units to PSU.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring implosion velocities in experiments and simulations of laser-driven cylindrical implosions on the OMEGA laser

Laser-driven magnetized liner inertial fusion (MagLIF) on OMEGA involves cylindrical implosions, a preheat beam, and an applied magnetic field. Initial experiments excluded the preheat beam and magnetic field to better characterize the implosion. X-ray self-emission as measured by framing cameras was used to determine the shell trajectory. The 1-D code LILAC was used to model the central region of the implosion, and results were compared to 2-D simulations from the HYDRA code. Post-processing of simulation output with SPECT3D and Yorick produced synthetic x-ray images that were used to compare the simulation results with the x-ray framing camera data. Quantitative analysis shows that higher measured neutron yields correlate with higher implosion velocities. The future goal is to further analyze the x-ray images to characterize the uniformity of the implosions and apply these analysis techniques to integrated laser-driven MagLIF shots to better understand the effects of preheat and the magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron emission during the implosion of a wire array onto a deuterated fiber

Results are presented from Z-pinch experiments performed in the S-300 facility (Kurchatov Institute) at a maximum current of 2 MA and current rise time of 100 ns. The Z-pinch load was a 1-cm-long 1-cmdiameter cylindrical array made of 40 tungsten wires with a total mass of 160 {mu}g, at the axis of which a 100-{mu}m-diameter (CD{sub 2}){sub n} deuterated fiber was installed. Hard X-ray and neutron signals were recorded using five scintillation detectors oriented in one radial and two axial directions. The maximum neutron yield from the DD reaction reached 3 x 10{sup 9} neutrons per shot. The average neutron energy was determined from time-of-flight measurements and Monte Carlo simulations under the assumption that the neutron emission time was independent of the neutron energy. The average neutron energy in different experiments was found to vary within the range 2.5-2.7 MeV. The fact that the average neutron energy was higher than 2.45 MeV (the energy corresponding to the DD reaction) is attributed to the beam-target collisional mechanism for the acceleration of deuterons to 100-500 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Dark-Field Tomography

We report how a grating interferometer yields neutron dark-field scatter images for tomographic investigations. The image contrast is based on ultrasmall-angle scattering. It provides otherwise inaccessible spatially resolved information about the distribution of micrometer and submicrometer sized structural formations. Three complementary sets of tomographic data corresponding to attenuation, differential phase, and small-angle scattering can be obtained from one measurement. The method is compatible with conventional imaging and provides significantly higher efficiency than existing techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heavy-ion versus {sup 3}He/{sup 4}He fusion-fission reactions: Angular momentum dependence of dissipation in nuclear fission

The stochastic Langevin model is employed to study dissipation properties in fission in the {sup 16}O + {sup 181}Ta {yields}{sup 197}Tl system by analyzing prescission neutron yields measured in this reaction. It has been found that the {sup 197}Tl nuclei undergo fission that is not in accordance with the standard Bohr-Wheeler statistical theory. A detailed comparison with previously published work in which fission excitation functions measured in {sup 3,4}He + {sup 197}Au {yields}{sup 200,201}Tl are shown to be in excellent agreement with the fission width formula predicted by the traditional models of nuclear fission suggests that nuclear dissipation strength may have an angular momentum dependence in addition to the known deformation and temperature dependence. Implications for the basic understanding of the observed abnormal rise in prescission particles at high energy and the need for further experimental confirmations are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Absolute Neutron Emission Measurement in Burning Plasma Experiments

The absolute measurement of neutron emission rate from the whole plasma is a very important diagnostics as a fusion power monitor in fusion experimental devices with D-T or D-T operations. Here measurement techniques of time-resolved and time-integrated absolute neutron emission on the present tokamaks and ITER are reviewed. In the present tokamaks, fission chamber installed outside the vacuum vessel are very popular in the absolute neutron emission rate measurement. As well as conventional neutron monitors installed outside the vacuum vessel, in-vessel neutron monitors using micro fission chamber are proposed for the absolute neutron emission rate measurement in ITER. The neutron activation system provides time-integrated measurements of the total neutron yield with high accuracy by using well known neutron reaction cross sections, which is useful to maintain a robust measure of fusion energy production with stability and wide dynamic range. The calibration of the relation between the neutron emission rate in the whole plasma and the output of neutron monitor is the most important issue in the absolute neutron emission rate measurements. The calibration of the neutron detectors has been performed by moving a neutron source such as a {sup 252}Cf neutron or a small accelerator-based neutron generator. For the calibration in ITER, the neutron generator with neutron emission rate of 10{sup 11} s{sup -1} or stronger is required to obtain high accuracy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute measurements of fast neutrons using yttrium

Yttrium is presented as an absolute neutron detector for pulsed neutron sources. It has high sensitivity for detecting fast neutrons. Yttrium has the property of generating a monoenergetic secondary radiation in the form of a 909 keV gamma-ray caused by inelastic neutron interaction. It was calibrated numerically using MCNPX and does not need periodic recalibration. The total yttrium efficiency for detecting 2.45 MeV neutrons was determined to be f{sub n}{approx}4.1x10{sup -4} with an uncertainty of about 0.27%. The yttrium detector was employed in the NX2 plasma focus experiments and showed the neutron yield of the order of 10{sup 8} neutrons per discharge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of Hydrodynamic Flows in Imploding Fusion Plasmas on the National Ignition Facility [plus supplemental information]

Inertial confinement fusion implosions designed to have minimal fluid motion at peak compression often show significant linear flows in the laboratory, attributable per simulations to percent-level imbalances in the laser drive illumination symmetry. In this work, we present experimental results which intentionally varied the mode 1 drive imbalance by up to 4% to test hydrodynamic predictions of flows and the resultant imploded core asymmetries and performance, as measured by a combination of DT neutron spectroscopy and high-resolution x-ray core imaging. Neutron yields decrease by up to 50%, and anisotropic neutron Doppler broadening increases by 20%, in agreement with simulations. Furthermore, a tracer jet from the capsule fill-tube perturbation that is entrained by the hot-spot flow confirms the average flow speeds deduced from neutron spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration methodology for proportional counters applied to yield measurements of a neutron burst

This paper introduces a methodology for the yield measurement of a neutron burst using neutron proportional counters. This methodology is to be applied when single neutron events cannot be resolved in time by nuclear standard electronics, or when a continuous current cannot be measured at the output of the counter. The methodology is based on the calibration of the counter in pulse mode, and the use of a statistical model to estimate the number of detected events from the accumulated charge resulting from the detection of the burst of neutrons. The model is developed and presented in full detail. For the measurement of fast neutron yields generated from plasma focus experiments using a moderated proportional counter, the implementation of the methodology is herein discussed. An experimental verification of the accuracy of the methodology is presented. An improvement of more than one order of magnitude in the accuracy of the detection system is obtained by using this methodology with respect to previous calibration methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Two Extraordinary AmLi Neutron Sources

Two legacy AmLi sources, MRC-101 and MRC-103, are routinely used for neutron detector characterization and testing campaigns that Pacific Northwest National Laboratory manages for the Defense Threat Reduction Agency within the U.S. Department of Defense. However, applicability of source measurement data has been substantially limited due to the lack of original manufacturer documentation and cross comparison to other sources. This paper summarizes results of the measurement campaign conducted to better quantify source radionuclide content, neutron energy spectrum and emission rate of the AmLi sources. The source characterization study consisted of three major consecutive measurement exercises. First, gamma spectrometry measurements using a high purity germanium detector were used to estimate the radionuclide content and potential impurities of the AmLi sources. Then neutron spectral measurements were taken to determine the unique neutron energy distribution. Finally, assessments of the total neutron yields of the sources were made with measurements in a neutron well counter. The neutron detection efficiency for these measurements was determined via detailed Monte Carlo modeling based on the neutron energy distribution measured with the rotating neutron spectrometer. The most exciting and unexpected finding of the study was a significant contamination of the source material with beryllium, contributing up to 17% to the total neutron emission rate and correspondingly changing the neutron energy spectrum. Also, the obtained lithium-only portion of the measured energy distribution of the sources was compared against several AmLi spectra previously reported by different researchers.

AWCC, AmLi, beryllium contamination, neutron spect↗

Performance of a hardened x-ray streak camera at Lawrence Livermore National Laboratory’s National Ignition Facility

Electron tubes continue to provide the highest speeds possible for recording dynamics of hot high-energy density plasmas. Standard streak camera drive electronics and CCD readout are not compatible with the radiation environment associated with high DT fusion yield inertial confinement fusion experiments >10 13 14 MeV DT neutrons or >10 9 n cm -2 ns -1 . Here, we describe a hardened x-ray streak camera developed for the National Ignition Facility and present preliminary results from the first experiment on which it has participated, recording the time-resolved bremsstrahlung spectrum from the core of an inertial confinement fusion implosion at more than 40× the operational neutron yield limit of the previous National Ignition Facility x-ray streak cameras.

47 OTHER INSTRUMENTATION↗

Sustained Neutron Production from a Sheared-Flow Stabilized Z Pinch

The sheared-flow stabilized Z pinch has demonstrated long-lived plasmas with fusion-relevant parameters. Here we present the first experimental results demonstrating sustained, quasi-steady-state neutron production from the fusion Z -pinch experiment, operated with a mixture of 20% deuterium/80% hydrogen by pressure. Neutron emissions lasting approximately 5 μs are reproducibly observed with pinch currents of approximately 200 kA during an approximately 16 μs period of plasma quiescence. The average neutron yield is estimated to be ( 1.25 ± 0.45 ) x 10 5 neutrons / pulse and scales with the square of the deuterium concentration. Coincident with the neutron signal, plasma temperatures of 1–2 keV and densities of approximately 10 17 cm -3 with 0.3 cm pinch radii are measured with fully integrated diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation of hot spots in the plasma of a Z-pinch produced from low-density deuterated polyethylene

Results are presented from experimental studies of the plasma formation dynamics in a Z-pinch produced from a cylindrical microporous agar-agar load. The experiments were performed on the S-300 facility at a current of 2 MA and current rise time of 100 ns. To enhance the energy concentration, a deuterated polyethylene neck with a mass density of 50-75 {mu}g/cm{sup 3} and diameter of 1-2 mm was made in the central part of the load. The spatiotemporal characteristics of the Z-pinch were studied using an optical streak camera and fast frame photography in the optical and soft X-ray spectral ranges. X-ray emission was detected using semiconductor and vacuum diodes, and neutron emission was studied by means of the time-of-flight method. It is found that, in the course of continuous plasma production, hot spots with a diameter of 100 {mu}m form in the pinch plasma. The hot spots emit short soft X-ray pulses with a duration of 2-4 ns, as well as neutron pulses with an average neutron energy of about 2.45 MeV. The maximum neutron yield was found to be 4.5 x 10{sup 9} neutrons per shot. The scenario of hot spot formation is adequately described by two-dimensional MHD simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗