Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Neutron-Friendly Li-Ion Battery Coin Cell for In Situ 3D Visualization of Li Plating

Advanced battery characterization using in situ/operando neutron imaging is critical for uncovering degradation modes such as lithium (Li) plating in Li-ion batteries (LIBs). However, conventional LIBs hinder operando neutron radiography (NR) and in situ neutron micro-computed tomography (N-μCT) for visualizing Li plating near the graphite-separator interface due to strong attenuation from hydrogen-rich components like PP–PE–PP separators, electrolyte, and Fe-based spacers. In this work, we designed and tested a neutron-friendly battery (NFB) optimized for in situ Li detection during extreme fast charging (XFC). Guided by neutron attenuation cross-sections and material transmission, the NFB enables clear visualization at the graphite–separator interface, which is typically opaque in standard LIBs. Electrochemical tests show the NFB exhibits voltage/current responses like standard cells for up to 50 XFC cycles. However, its lower reversibility and capacity are likely due to Cu-coated Al spacer degradation from delamination or corrosion. We propose titanium spacers as a more stable alternative, albeit requiring custom machining. Using this optimized cell, we achieved simultaneous neutron tomography of multiple cells, capturing in situ 3D images of dead Li accumulation, particularly near graphite edges. These heterogeneous deposits and disconnected Li clusters suggest localized current density hotspots during XFC.

25 ENERGY STORAGE↗

A Portable Miniature Cryogenic Environment for In Situ Neutron Diffraction

Neutron diffraction instruments offer a platform for materials science and engineering studies at extended temperature ranges far from ambient. As one of the widely used neutron sample environment types, cryogenic furnaces are usually bulky and complex, and they may need hours of beamtime overhead for installation, configuration, cooling, and sample change, etc. To reduce the overhead time and expedite experiments at the state-of-the-art high-flux neutron source, we developed a low-cost, miniature, and easy-to-use cryogenic environment (77–473 K) for in situ neutron diffraction. A travel-size mug serves for the environment where the samples sit inside. Immediate cooling and an isothermal dwell at 77 K are realized on the sample by direct contact with liquid N 2 in the mug. The designed Al inserts serve as the holder of samples and heating elements, alleviate the thermal gradient, and clear neutron pathways. Both a single-sample continuous measurement and multi-sample high-throughput measurements are demonstrated in this environment. High-quality and refinable in situ neutron diffraction patterns are acquired on model materials. The results quantify the orthorhombic-to-cubic phase transformation process in LiMn 2 O 4 and differentiate the anisotropic lattice thermal expansions and bond length evolutions between rhombohedral perovskite oxides with composition variation.

47 OTHER INSTRUMENTATION↗

High-energy neutron spectroscopy with thick silicon detectors

The high-energy neutron component of the space radiation environment in thick structures such as the International Space Station contributes to the total radiation dose received by an astronaut. Detector design constraints such as size and mass have limited the energy range of neutron spectrum measurements in orbit to about 12 MeV in Space Shuttle studies. We present a new method for high-energy neutron spectroscopy using small silicon detectors that can extend these measurements to more than 500 MeV. The methodology is based on measurement of the detector response function for high-energy neutrons and inversion of this response function with measured deposition data to deduce neutron energy spectra. We also present the results of an initial shielding study performed with the thick silicon detector system for high-energy neutrons incident on polyethylene.

Non-NASA Center↗

Neutron measurements onboard the space shuttle

The radiation environment inside a shielded volume is highly complex, consisting of both charged and neutral particles. Since the inception of human space flights, the charged particle component has received virtually all of the attention. There is however, a significant production of secondary neutrons, particularly from the aluminum structure in low earth orbiting spacecrafts. The interactions of galactic cosmic rays (GCR), and solar energetic particles with the earth's atmosphere produce a non-isotropic distribution of albedo neutrons. Inside any reasonable habitable module, the average radiation quality factor of neutrons is about 4-5 times larger than the corresponding average quality factor of charged particles. The measurement of neutrons and their energy spectra is a difficult problem due the intense sources of charged particles. This paper reviews the results of Shuttle flight experiments (made during both solar maximum and solar minimum) to measure the contribution of neutrons to the dose equivalent, as well as theoretical calculations to estimate the appropriate range of neutron energies that contribute most to the dose equivalent. Published by Elsevier Science Ltd.

short duration↗

Neutron environments on the Martian surface

Radiation is a primary concern in the planning of a manned mission to Mars. Recent studies using NASA Langley Research Center's HZETRN space radiation transport code show that the low energy neutron fluence on the Martian surface is larger than previously expected. The upper atmosphere of Mars is exposed to a background radiation field made up of a large number of protons during a solar particle event and mixture of light and heavy ions caused by galactic cosmic rays at other times. In either case, these charged ions interact with the carbon and oxygen atoms of the Martian atmosphere through ionization and nuclear collisions producing secondary ions and neutrons which then interact with the atmospheric atoms in a similar manner. In the past, only these downward moving particles have been counted in evaluating the neutron energy spectrum on the surface. Recent enhancements in the HZETRN code allow for the additional evaluation of those neutrons created within the Martian regolith through the same types of nuclear reactions, which rise to the surface. New calculations using this improved HZETRN code show that these upward moving neutrons contribute significantly to the overall neutron spectrum for energies less than 10 MeV.

NASA Center LaRC↗

Quantitative assessment of the cataractogenic potential of very low doses of neutrons

We report on the prevalence and relative biological effectiveness (RBE) for various stages of lens opacification in rats induced by very low doses (2 to 250 mGy) of medium-energy (440 keV) neutrons, compared to those for X rays. Neutron doses were delivered either in a single fraction or in four separate fractions and the irradiated animals were followed for over 100 weeks. At the highest observed dose (250 mGy) and at early observation times, there was evidence of an inverse dose-rate effect; i.e., a fractionated exposure was more potent than a single exposure. Neutron RBEs relative to X rays were estimated using a non-parametric technique. The results were only weakly dependent on time postirradiation. At 30 weeks, for example, 80% confidence intervals for the RBE of acutely delivered neutrons relative to X rays were 8-16 at 250 mGy, 10-20 at 50 mGy, 50-100 at 10 mGy and 250-500 at 2 mGy. The results are consistent with the estimated neutron RBEs in Japanese A-bomb survivors, though broad confidence bounds are present in the Japanese results. Our findings are also consistent with data reported earlier for cataractogenesis induced by heavy ions in rats, mice, and rabbits. We conclude from these results that, at very low doses (<10 mGy), the RBE for neutron-induced cataractogenesis is considerably larger than the RBE of 20 commonly used, and use of a significantly larger value for calculating equivalent dose would be prudent.

NASA Discipline Radiation Health↗

Global Maps of Lunar Neutron Fluxes from the LEND Instrument

The latest neutron spectrometer measurements with the Lunar Exploration Neutron Detector (LEND) onboard the Lunar Reconnaissance Orbiter (LRO) are presented. It covers more than 1 year of mapping phase starting on 15 September 2009. In our analyses we have created global maps showing regional variations in the flux of thermal (energy range < 0.015 eV) and fast neutrons (>0.5 MeV), and compared these fluxes to variances in soil elemental composition, and with previous results obtained by the Lunar Prospector Neutron Spectrometer (LPNS). We also processed data from LEND collimated detectors and derived a value for the collimated signal of epithermal neutrons based on the comparative analysis with the LEND omnidirectional detectors. Finally, we have compared our final (after the data reduction) global epithermal neutron map with LPNS data.

Epithermal neutrons↗

Promoting the regulatory acceptance of combined ion and neutron irradiation for material degradation in nuclear reactors

The Advanced Materials and Manufacturing Technologies (AMMT) program within the Department of Energy (DOE) Office of Nuclear Energy has developed its current recommendation for promoting the use of combined ion irradiation and neutron irradiation for the accelerated qualification of materials to be deployed in nuclear reactors. This plan is intended to provide a collaborative path forward that can be adopted by academia, national laboratories, and industry, and has been developed with input from the regulatory research arm of the U.S. Nuclear Regulatory Commission (NRC). To deploy new materials or materials manufactured with new technologies, such as additive manufacturing, materials must be evaluated for reactor-induced degradation from the combination of harsh temperatures, corrosive environments, and radiation fields. However, rapid deployment of materials necessitates accelerated testing methods rather than relying on years of neutron irradiation in a material test reactor. Ion irradiation has demonstrated success in reproducing material microstructure and select property evolution resulting from neutron irradiation with three to four orders of magnitude reduction in time and cost, making it an ideal candidate for accelerated irradiation testing. This presentation provides context governing both the scientific and regulatory aspects of the proposed goal. The discussion is aimed at a broad audience including researchers from industry, national laboratories, and academia. The recommended path forward is presented as a conceptual framework of specific steps. In brief, the strategy entails developing an integrated ion and neutron irradiation test plan for the material property of interest based on the fundamental tenet of the linkage of microstructure and properties in materials. Physics-based modeling interprets ion irradiation data and predicts neutron irradiation microstructure and properties with uncertainty bounds. The first round of testing is sufficient for an initial licensing application using a risk-informed approach, while a minimum required neutron irradiation test plan reduces cost and time requirements. A surveillance program with witness specimens in-reactor provides additional data over time to improve model predictions to higher damage levels and further reduce uncertainty bounds, which can be used for license extensions or longer lifetimes in new license applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Magnetic pair distribution function and half polarized neutron powder diffraction at the HB-2A powder diffractometer

Local magnetic order and anisotropy are often central for understanding fundamental behavior and emergent functional properties in quantum materials and beyond. Advances in neutron powder diffraction experiments and analysis tools now allow for quantitative determination. Here, we demonstrate this here with complementary total neutron scattering and polarized neutron measurements on the HB-2A neutron powder diffractometer at the High Flux Isotope Reactor (HFIR). In recent years, magnetic pair distribution function (mPDF) analysis has emerged as a powerful technique for probing local magnetic spin ordering of magnetic materials. This method can be broadly applied to any magnetic material but is particularly effective for studying systems with short-range magnetic order, such as materials with reduced dimensionality, geometrically frustrated magnets, thermoelectrics, multiferroics, and correlated paramagnets. Magnetic anisotropy often underpins the short-range order adopted. Half-polarized neutron powder diffraction (pNPD) can be used to determine the local susceptibility tensor on the magnetic sites to quantify the magnetic anisotropy. Combining the techniques of mPDF and pNPD can therefore provide valuable insights into local magnetic behavior. A series of measurements optimized for these techniques are presented as exemplar cases focused on frustrated materials where short-range order dominates, these include measurements to ultra-low temperature (<100 mK) not typically accessible for such experiments.

Half polarized neutron scattering↗

Thermal deflection in neutron scattering sample environments at Oak Ridge National Laboratory

The neutron sources at Oak Ridge National Laboratory use a wide suite of sample environment equipment to deliver extreme conditions for a number of experiments. Much of this instrumentation focuses on extremes of temperature, such as cryostats, closed-cycle refrigerators in both low and high temperature configurations, and radiant heating furnaces. When the temperature is controlled across a large range, thermal deflection effects can notably move the sample and affect its alignment in the beam. Here, we combine these sample environments with neutron imaging and machine vision to determine the motion of a representative sample with respect to the neutron beam. We find vertical sample displacement on the order of 1–2 mm and horizontal displacement that varies from near-negligible to 1.2 mm. While these deflections are not relevant for some of the beamlines at the first target station at the spallation neutron source and the high flux isotope reactor, they will become critical for upcoming instrumentation at the second target station, as well as any instruments targeting sub-mm samples, as neutron sources and optics evolve to smaller and more focused beams. We discuss mitigation protocols and potential modifications to the environment to minimize the effect of misalignment due to thermal deflection.

47 OTHER INSTRUMENTATION↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

Neutron Scattering in Sodium-Ion Battery Research: Progress and Prospects

Sodium-ion batteries have attracted renewed interest in recent years and are widely studied as a complementary power source to Li-ion batteries for large-scale stationary energy storage and small electric vehicles. Compared with Li-ion batteries, Na-ion batteries offer several advantages, including elemental abundance, lower cost, improved safety, and better low-temperature performance. An in-depth understanding of Na-ion batteries across multiple length and time scales has further accelerated the rapid development of this technology. Among the various advanced characterization techniques used to study Na-ion batteries, neutron scattering has gained significant traction in recent years. It has become a powerful and versatile tool for probing structure, morphology, and sodium-ion dynamics over a wide range of length and time scales. In this article, we will briefly review the development of neutron scattering technology and highlight recent advances in applying neutron-based techniques—including neutron diffraction, total scattering, small-angle scattering, quasi-elastic/inelastic scattering, and neutron imaging—to Na-ion battery materials. We also provide perspectives on future technique developments, particularly in the realm of in situ and operando neutron scattering characterization, and discuss how these approaches could further enhance our understanding of Na-ion battery systems.

Liu, Jue [ORNL] (ORCID:000000024453910X)↗

Neutron Grating Interferometry at the High Flux Isotope Reactor

Neutron imaging is a non-destructive probe that can spatially resolve bulk materials’ internal features/structures. Neutron imaging spatial resolution is driven by detector technology, i.e., pixel size, and is currently on the order of 10–20 µm. This limitation can be alleviated by the use of neutron grating interferometry – an advanced neutron imaging technique – that enables simultaneous access to three contrast mechanisms: attenuation, differential phase, and small-angle neutron scattering. Recently, a Talbot-Lau neutron grating interferometry has been implemented at the Multimodal Advanced Radiography Station at the High Flux Isotope Reactor. In this work, the design, setup and performance of the grating apparatus are presented.

Zhang, Yuxuan [ORNL] (ORCID:0000000200831408)↗

Understanding neutron capture processes in uranium deposits using combined U-Sm-Nd isotopic compositions

Valuable insights into the history and evolution of a geologic deposit can be found by investigating neutron capture reactions. Thermal neutron capture reactions occur within both the samarium (Sm) and the uranium (U) systems, where 149 Sm and 235 U can capture neutrons to become 150 Sm and 236 U, respectively. Although largely unexplored, paired measurements of 150 Sm and 236 U could be important for understanding neutron capture effects within uranium ore bodies, and such measurements are potentially useful in nuclear forensics for assessing a material's provenance or mineral exploration. In this work, we refined measurement procedures of Sm isotope compositions utilizing MC-ICPMS. While geologic reference materials were found to have indistinguishable Sm isotope compositions, we found significant isotope variations consistent with nuclear field shift among synthetic Sm standards. Here, this observation highlights that future high-precision Sm isotope investigations need to carefully evaluate synthetic standard(s) against geologic reference materials until an unfractionated and agreed-upon standard is identified. Here, we applied this method to a set of nine uranium ores from the South Australian Beverley North uranium deposits. Although 236 U excesses had been previously reported for these U ores, we found no measurable isotopic shifts in 149 Sm- 150 Sm at the current level of precision (±5 parts per million). One possible explanation for this disparity in the observed neutron capture signatures between U and Sm is that the source(s) of the U and Sm in these ores may be decoupled. This is consistent with the finding that these ores have variable 143 Nd/ 144 Nd, thus demonstrating that diverse sources were involved in the formation of the Beverley North deposits. Alternatively, this deposit may be too young (<50Ma) to have accumulated measurable neutron capture effects in Sm to be detected with the methods employed here.

Mineral exploration↗

Comparison of hardening and microstructures of ferritic/martensitic steels irradiated with fast neutrons and dual ions

Ferritic/martensitic steels T91 and HT9 were irradiated with neutrons (BOR-60 reactor) and dual ions (9 MeV Fe 3+ and 3.42 MeV energy degraded He 2+ ) from 369 to 520 °C and damage levels of 16.6 to 72 dpa to quantify the possibility of using ion irradiation to simulate neutron irradiation in terms of microstructures and mechanical properties. Nanoindentation testing was performed to obtain the bulk equivalent hardness of the dual-ion irradiated samples. For the neutron irradiated samples, both nanoindentation and Vickers hardness testing were conducted. Transmission Electron Microscopy (TEM) characterizations of the cavities, dislocation loops and precipitates were conducted to account for the strengthening contribution of each microstructure element. The good agreement between the microstructure-predicted (dispersed barrier hardening) and measured strength of the irradiated specimens demonstrated the accuracy of the strengthening model and the nanoindentation tests. Furthermore, the comparison of mechanical property and microstructure changes in ion and neutron irradiated structural materials indicated that ion irradiation replicated many neutron irradiation features. However, a single 70 °C temperature shift is insufficient to match all complex microstructures of neutron vs. ion irradiation over the irradiation temperature range of 369–520 °C.

36 MATERIALS SCIENCE↗

Low energy neutron light output characterization of EJ301D and deuterated stilbene with a comparison of light output characterization methods

The neutron-induced light yield of a 2.54 cm diameter by 2.54 cm long right circular cylinder of EJ301D and a (5.08 cm)3 custom made cube of deuterated trans-stilbene-d12 (d-stilbene) were measured over incident neutron energies from 300 keV to 2.2 MeV and 200 keV to 2.4 MeV, respectively. The measurements were performed using a time-of-flight experiment with a Cf-252 source and an approximately 1.5 m flight path. We compare three light output spectrum full energy deposition edge estimation methods: (1) simulating the neutron energy spectrum edge and fitting it to the light output spectrum, (2) using the inflection point of the light output spectrum edge (derivative method, a.k.a. Kornilov’s method), and (3) using an empirical model fit to the edge of the light output spectrum. Both the derivative and equation fit methods do not account for physical processes such as multiple neutron scattering in the detectors. They instead rely on assumptions about the linear shape continuum shape of the light output spectrum and the direct correlation between the location of the spectrum’s inflection point and maximum energy deposition. These assumptions were found to introduce bias into those methods when tested against simulated spectra with known edge locations. When tested against measured spectra the derivative method was found to differ from the simulation fit by greater than 30% at low energies with large discontinuities for adjacent data points above 800 keV incident neutron energy. The empirical equation fitting method was found to also exhibit bias of a similar magnitude, but with significantly more continuous behavior, especially with the lower count data of the smaller volumed EJ301D scintillator. Experimental light output yield for this neutron energy range is reported using the simulated spectrum fitting method because it includes physics neglected by the other methods, and did not exhibit the bias observed in the other methods

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗