Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Checking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Experimental study of the γ p → π 0 η p reaction with the A2 setup at the Mainz Microtron

Here, the data available from the A2 Collaboration at MAMI were analyzed to select the γp → π 0 ηp reaction on an event-by-event basis, which allows for partial-wave analyses of three-body final states to obtain more reliable results, compared to fits to measured distributions. These data provide the world’s best statistical accuracy in the energy range from threshold to E γ = 1.45 GeV, allowing a finer energy binning in the measurement of all observables needed for understanding the reaction dynamics. The results obtained for the measured observables are compared to existing models, and the impact from the new data is checked by the fit with the revised Mainz model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determinants of Patient Satisfaction During Receipt of Radiation Therapy

Purpose: To evaluate the correlations and relative contributions of components of a radiation oncology-specific patient satisfaction survey to their overall satisfaction scores. Methods and Materials: From September 2006 through August 2012, we prospectively collected data from 8069 patients receiving radiation treatments with a 26-question survey. Each question was rated on a 10-point Likert scale. We analyzed the correlation between scores for each question and the overall satisfaction question. We also dichotomized the scores to reflect satisfaction versus dissatisfaction and used logistic regression to assess the relationship between items in 4 domains (the patient–provider relationship, access and environmental issues, wait times, and educational information) and overall satisfaction. Results: Scores on all questions correlated with overall patient satisfaction scores (P<.0001). Satisfaction with patient–provider relationships had the greatest influence on overall satisfaction (R{sup 2}=0.4219), followed by wait times (R{sup 2}=0.4000), access/environment (R{sup 2}=0.3837), and patient education (R{sup 2}=0.3700). The specific variables with the greatest effect on patient satisfaction were the care provided by radiation therapists (odds ratio 1.91) and pain management (odds ratio 1.29). Conclusions: We found that patients' judgment of provider relationships in an outpatient radiation oncology setting were the greatest contributors to their overall satisfaction ratings. Other measures typically associated with patient satisfaction (phone access, scheduling, and ease of the check-in process) correlated less strongly with overall satisfaction. These findings may be useful for other practices preparing to assess patient ratings of quality of care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Global Harmonization of Quality Assurance Naming Conventions in Radiation Therapy Clinical Trials

Purpose: To review the various radiation therapy quality assurance (RTQA) procedures used by the Global Clinical Trials RTQA Harmonization Group (GHG) steering committee members and present the harmonized RTQA naming conventions by amalgamating procedures with similar objectives. Methods and Materials: A survey of the GHG steering committee members' RTQA procedures, their goals, and naming conventions was conducted. The RTQA procedures were classified as baseline, preaccrual, and prospective/retrospective data capture and analysis. After all the procedures were accumulated and described, extensive discussions took place to come to harmonized RTQA procedures and names. Results: The RTQA procedures implemented within a trial by the GHG steering committee members vary in quantity, timing, name, and compliance criteria. The procedures of each member are based on perceived chances of noncompliance, so that the quality of radiation therapy planning and treatment does not negatively influence the trial measured outcomes. A comparison of these procedures demonstrated similarities among the goals of the various methods, but the naming given to each differed. After thorough discussions, the GHG steering committee members amalgamated the 27 RTQA procedures to 10 harmonized ones with corresponding names: facility questionnaire, beam output audit, benchmark case, dummy run, complex treatment dosimetry check, virtual phantom, individual case review, review of patients' treatment records, and protocol compliance and dosimetry site visit. Conclusions: Harmonized RTQA harmonized naming conventions, which can be used in all future clinical trials involving radiation therapy, have been established. Harmonized procedures will facilitate future intergroup trial collaboration and help to ensure comparable RTQA between international trials, which enables meta-analyses and reduces RTQA workload for intergroup studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Groundwater Monitoring of Uranium at the Hanford Site, Washington - 13116

An automated groundwater monitoring system for the detection of uranyl ion in groundwater was deployed at the 300 Area Industrial Complex, Hanford Site, Washington. The research was conducted to determine if at-site, automated monitoring of contaminant movement in the subsurface is a viable alternative to the baseline manual sampling and analytical laboratory assay methods currently employed. The monitoring system used Arsenazo III, a colorimetric chelating compound, for the detection of the uranyl ion. The analytical system had a limit of quantification of approximately 10 parts per billion (ppb, μg/L). The EPA's drinking water maximum contaminant level (MCL) is 30 ppb [1]. In addition to the uranyl ion assay, the system was capable of acquiring temperature, conductivity, and river level data. The system was fully automated and could be operated remotely. The system was capable of collecting water samples from four sampling sources, quantifying the uranyl ion, and periodically performing a calibration of the analytical cell. The system communications were accomplished by way of cellular data link with the information transmitted through the internet. Four water sample sources were selected for the investigation: one location provided samples of Columbia River water, and the remaining three sources provided groundwater from aquifer sampling tubes positioned in a vertical array at the Columbia River shoreline. The typical sampling schedule was to sample the four locations twice per day with one calibration check per day. This paper outlines the instrumentation employed, the operation of the instrumentation, and analytical results for a period of time between July and August, 2012. The presentation includes the uranyl ion concentration and conductivity results from the automated sampling/analysis system, along with a comparison between the automated monitor's analytical performance and an independent laboratory analysis. Benefits of using the automated system as an alternative to traditional sample collection and analysis includes the following: - Field observations that provide more characterization information than is possible using traditional monitoring methods. - Potentially significant reductions in labor and analytical costs if traditional methods are complemented by automated systems. - The reduced cost of acquiring samples will allow for more frequent collection of samples that may be automatically introduced into real-time graphical flux programs allowing site managers to observe the changes in contaminant concentrations during remediation projects and across discrete river stage events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

As-Built Simulation of the High Flux Isotope Reactor

The Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR) is an 85 MWt flux trap-type research reactor that supports key research missions, including isotope production, materials irradiation, and neutron scattering. The core consists of an inner and an outer fuel element containing 171 and 369 involute-shaped plates, respectively. The thin fuel plates consist of a U 3 O 8 -Al dispersion fuel (highly enriched), an aluminum-based filler, and aluminum cladding. The fuel meat thickness is varied across the width of the involute plate to reduce thermal flux peaks at the radial edges of the fuel elements. Some deviation from the designed fuel meat shaping is allowed during manufacturing. A homogeneity scan of each fuel plate checks for potential anomalies in the fuel distribution by scanning the surface of the plate and comparing the attenuation of the beam to calibration standards. While typical HFIR simulations use homogenized fuel regions, explicit models of the plates were developed under the Low-Enriched Uranium Conversion Program. These explicit models typically include one inner and one outer fuel plate with nominal fuel distributions, and then the plates are duplicated to fill the space of the corresponding fuel element. Therefore, data extracted from these simulations are limited to azimuthally averaged quantities. To determine the reactivity and physics impacts of an as-built outer fuel element and generate azimuthally dependent data in the element, 369 unique fuel plate models were generated and positioned. This model generates the three-dimensional (i.e., radial–axial–azimuthal) plate power profile, where the azimuthal profile is impacted by features within the adjacent control element region and beryllium reflector. For an as-built model of the outer fuel element, plate-specific homogeneity data, 235 U loading, enrichment, and channel thickness measurements were translated into the model, yielding a much more varied azimuthal power profile encompassed by uncertainty factors in analyses. These models were run with the ORNL-TN and Shift Monte Carlo tools, and they contained upwards of 500,000 cells and 100,000 unique tallies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dosimetry revisited for the HDR {sup 192}Ir brachytherapy source model mHDR-v2

Purpose: Recently, the manufacturer of the HDR {sup 192}Ir mHDR-v2 brachytherapy source reported small design changes (referred to herein as mHDR-v2r) that are within the manufacturing tolerances but may alter the existing dosimetric data for this source. This study aimed to (1) check whether these changes affect the existing dosimetric data published for this source; (2) obtain new dosimetric data in close proximity to the source, including the contributions from {sup 192}Ir electrons and considering the absence of electronic equilibrium; and (3) obtain scatter dose components for collapsed cone treatment planning system implementation. Methods: Three different Monte Carlo (MC) radiation transport codes were used: MCNP5, PENELOPE2008, and GEANT4. The source was centrally positioned in a 40 cm radius water phantom. Absorbed dose and collision kerma were obtained using 0.1 mm (0.5 mm) thick voxels to provide high-resolution dosimetry near (far from) the source. Dose-rate distributions obtained with the three MC codes were compared. Results: Simulations of mHDR-v2 and mHDR-v2r designs performed with three radiation transport codes showed agreement typically within 0.2% for r{>=}0.25 cm. Dosimetric contributions from source electrons were significant for r<0.25 cm. The dose-rate constant and radial dose function were similar to those from previous MC studies of the mHDR-v2 design. The 2D anisotropy function also coincided with that of the mHDR-v2 design for r{>=}0.25 cm. Detailed results of dose distributions and scatter components are presented for the modified source design. Conclusions: Comparison of these results to prior MC studies showed agreement typically within 0.5% for r{>=}0.25 cm. If dosimetric data for r<0.25 cm are not needed, dosimetric results from the prior MC studies will be adequate.

60 APPLIED LIFE SCIENCES↗

Plutonium-238 Loadout Calorimeter Return To Service

The calorimeter in the transfer area in Building 7920 at the US Department of Energy’s Oak Ridge National Laboratory is used to measure the amount of 238 Pu in the Plutonium Heat Source Oxide. The calorimetry measurement is taken after the oxide is packaged in an ORISC (Oak Ridge Inner Shipping Capsule)/FSO (Fuel Storage Outer) assembly before loading into the Containment Vessel and shipping container. The equipment is used in three specific configurations: zero measurement (nothing in the sample cup), FSO measurement (actual measurement of 238 Pu), and reference calibration measurement (using the reference FSO as a known heat source). System checks were performed in July 2023 in preparation for scheduled material loadout. During these checks, personnel discovered that the reference FSO had experienced an electrical short in the heater cable and was no longer functional. The calorimeter was in the reference calibration measurement configuration at this time. Facility management was notified when the damage was discovered. The data from the Yokogawa recorder were pulled and analyzed for a span of time between September 2022 and July 2023. An unusual spike was found in the sample cup temperature data that started on October 19, 2022, and ended on October 20, 2022. The sample cup reached a temperature of 191.1°C. The maximum allowable temperature for the calorimeter thermopile to reach is 220°C based on the manufacturer statement provided in Appendix B of this report [1]. The calorimeter thermopile and the sample cup thermocouple are physically close to each other; therefore, the data suggest that the calorimeter itself never saw a temperature in excess of 191.1°C. Physical damage present on the cable, tape, and insulation suggests that the temperature reached a higher value in some locations within the sample cup than the data shows. Because of this discrepancy, testing of the calorimeter was required to confirm that the calorimeter is functioning the same as it was before the electrical short. The intent of this report is to assess the functionality of the calorimeter and determine if it is acceptable to use for 238 Pu loadout material measurement. Testing showed that the calorimeter is functionally equivalent to the initial calibration that was performed in the summer of 2021, and thus, the calorimeter was cleared to be used for its intended purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pre-Viking Swedish Hillfort Glass: A Prospective Long-Term Alteration Analogue for Vitrified Nuclear Waste

Examining ancient anthropogenic glasses altered in natural environments over hundreds of years can inform and verify models for predicting long-term rates of glass corrosion. Understanding corrosion mechanisms is critical for modeling the performance of nuclear waste glasses that are required to retain radionuclides for >1000 years, and will be disposed in shallow subsurface environments. Two types of ancient Swedish hillfort glasses — one clear, iron-poor glass, and one dark, iron-rich glass — have been characterized to evaluate their use as long-term alteration analogues for vitrified nuclear waste disposed under near-surface conditions. These glasses are of interest to the nuclear waste glass community as they have comparable elemental compositions to glasses under development for disposal of nuclear waste at the Hanford Site, USA. They are also of historical importance to Sweden; thus, an analysis protocol, focusing on non-destructive to semi-destructive analyses, has been developed to maintain the historical integrity of the samples. X-ray computed tomography, micro X-ray diffraction, micro X-ray fluorescence, and electron microscopy data are presented for both vitreous and mineralogical components of the hillfort samples. The internal microstructure and elemental distribution of the glasses, including the presence of crystalline inclusions, are discussed in the context of ancient glassmaking technology.

Weaver, Jamie L.↗

Potential Application Of Radionuclide Scaling Factors To High Level Waste Characterization

Production sources, radiological properties, relative solubilities in waste, and laboratory analysis techniques for the forty-five radionuclides identified in Hanford's Waste Treatment and Immobilization Plant (WTP) Feed Acceptance Data Quality Objectives (DQO) document are addressed in this report. Based on Savannah River Site (SRS) experience and waste characteristics, thirteen of the radionuclides are judged to be candidates for potential scaling in High Level Waste (HLW) based on the concentrations of other radionuclides as determined through laboratory measurements. The thirteen radionuclides conducive to potential scaling are: Ni-59, Zr-93, Nb-93m, Cd-113m, Sn-121m, Sn-126, Cs-135, Sm-151, Ra-226, Ra-228, Ac-227, Pa-231, and Th-229. The ability to scale radionuclides is useful from two primary perspectives: 1) it provides a means of checking the radionuclide concentrations that have been determined by laboratory analysis; and 2) it provides a means of estimating radionuclide concentrations in the absence of a laboratory analysis technique or when a complex laboratory analysis technique fails. Along with the rationale for identifying and applying the potential scaling factors, this report also provides examples of using the scaling factors to estimate concentrations of radionuclides in current SRS waste and into the future. Also included in the report are examples of independent laboratory analysis techniques that can be used to check results of key radionuclide analyses. Effective utilization of radionuclide scaling factors requires understanding of the applicable production sources and the chemistry of the waste. As such, the potential scaling approaches identified in this report should be assessed from the perspective of the Hanford waste before reaching a decision regarding WTP applicability.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

X-Ray Absorbed, Broad-Lined, Red AGN and the Cosmic X-Ray Background

We have obtained XMM spectra for five red, 2MASS AGN, selected from a sample observed by Chandra to be X-ray bright and to cover a range of hardness ratios. Our results confirm the presence of substantial absorbing material in three sources which have optical classifications ranging from Type 1 to Type 2, with an intrinsically flat (hard) power law continuum indicated in the other two. The presence of both X-ray absorption and broad optical emission lines with the usual strength suggests either a small (nuclear) absorber or a favored viewing angle so as to cover the X-ray source but not the broad emission line region (BELR). A soft excess is detected in all three Type 1 sources. We speculate that this soft X-ray emission may arise in an extended region of ionized gas, perhaps linked with the polarized (scattered) light which is a feature of these sources. The spectral complexity revealed by XMM emphasizes the limitations of the low S/N Chandra data. Overall, the new XMM results strengthen our conclusions (Wilkes et al. 2002) that the observed X-ray continua of red AGN are unusually hard at energies greater than 2 keV. Whether due to substantial line-of-sight absorption or to an intrinsically hard or reflection-dominated spectrum, these 'red' AGN have an observed spectral form consistent with contributing significantly to the missing had absorbed population of the Cosmic X-ray Background (CXRB). When absorption and or reflection is taken into account, all these AGN have power law slopes typical of broad-line (Type 1) AGN (Gamma approximately 1.9). This appears to resolve the spectral paradox which for so long has existed between the CXRB and the AGN thought to be the dominant contributors. It also suggests two scenarios whereby Type 1 AGN/QSOs may be responsible for a significant fraction of the CXRB at energies above 2 keV: 1) X-ray absorbed AGN/QSOs with visible broad emission lines; 2) AGN/QSOs with complex spectra whose hardness greater than 2 keV is not detectable in the typically low S/N data of X-ray surveys. Even if absorption is present in only half of the population, the large number of 'red' AGN suggests a development of unification models, where the continuum source is surrounded, over a substantial solid angle, by the wind or atmosphere of an accretion disk/torus. X-ray observations of such AGN not only provide a check on the presence of absorption, but also a unique probe of the absorbing material. Improved information on their space density, in particular as a function of redshift, will soon be provided by Spitzer-Chandra wide area surveys, allowing better estimates of both the importance of red AGN to the full AGN population and their contribution to the CXRB.

Mushotzky, Richard↗

Report on the AAPM grand challenge on deep generative modeling for learning medical image statistics

Abstract Background The findings of the 2023 AAPM Grand Challenge on Deep Generative Modeling for Learning Medical Image Statistics are reported in this Special Report. Purpose The goal of this challenge was to promote the development of deep generative models for medical imaging and to emphasize the need for their domain‐relevant assessments via the analysis of relevant image statistics. Methods As part of this Grand Challenge, a common training dataset and an evaluation procedure was developed for benchmarking deep generative models for medical image synthesis. To create the training dataset, an established 3D virtual breast phantom was adapted. The resulting dataset comprised about 108 000 images of size 512 512. For the evaluation of submissions to the Challenge, an ensemble of 10 000 DGM‐generated images from each submission was employed. The evaluation procedure consisted of two stages. In the first stage, a preliminary check for memorization and image quality (via the Fréchet Inception Distance [FID]) was performed. Submissions that passed the first stage were then evaluated for the reproducibility of image statistics corresponding to several feature families including texture, morphology, image moments, fractal statistics, and skeleton statistics. A summary measure in this feature space was employed to rank the submissions. Additional analyses of submissions was performed to assess DGM performance specific to individual feature families, the four classes in the training data, and also to identify various artifacts. Results Fifty‐eight submissions from 12 unique users were received for this Challenge. Out of these 12 submissions, 9 submissions passed the first stage of evaluation and were eligible for ranking. The top‐ranked submission employed a conditional latent diffusion model, whereas the joint runners‐up employed a generative adversarial network, followed by another network for image superresolution. In general, we observed that the overall ranking of the top 9 submissions according to our evaluation method (i) did not match the FID‐based ranking, and (ii) differed with respect to individual feature families. Another important finding from our additional analyses was that different DGMs demonstrated similar kinds of artifacts. Conclusions This Grand Challenge highlighted the need for domain‐specific evaluation to further DGM design as well as deployment. It also demonstrated that the specification of a DGM may differ depending on its intended use.

Radiology, Nuclear Medicine & Medical Imaging↗

Templating as a Chain of Custody Tool for Arms Control

Historically, templates have been considered for use as a treaty accountable item (TAI) authentication tool, alongside item attributes. Because of this, the use of templates has fallen by the wayside due to the perceived intrusiveness of and handling/storage of template data; especially when compared to the negotiability of unclassified attribute threshold values. However, as a chain of custody tool, templates potentially have a large and important role to play in maintaining confidence in the authenticity of the treaty accountable items as they progress through an arms control regime. In general terms, templating is the process of creating a unique, measurable, and repeatable signature which is representative of the TAI. At any point in time, the signature can be re-measured or re-inspected to verify the signature has not changed. Chain of custody is the process by which a controlled boundary is established and maintained around a TAI to both deter and detect unauthorized access to the item. Typically, this is accomplished by putting a tamper indicating device (TID) on the item or container. The TID now acts as a surrogate for the item itself, and is continually checked to ensure the unique identifier and tamper indicating mechanisms have not changed since last inspection. This in and of itself is a form of templating. A stronger template is one that utilizes a signature of the combined item and container. There are many potential signatures which may be exploited, including radiation-, electromagnetic-, and acoustic-based signatures. This paper/presentation will explore the technology and mechanisms in which templating can be applied to create a more robust chain of custody over treaty accountable items as part of a future arms control regime.

Nuclear Warhead, Chain of Custody, Templates, Non-↗

Methods for a blind analysis of isobar data collected by the STAR collaboration

In 2018, the STAR collaboration collected data from $_{44}^{96}{\mathrm{Ru}}+_{44}^{96}{\mathrm{Ru}}$ and $_{40}^{96}{\mathrm{Zr}}+_{40}^{96}{\mathrm{Zr}}$ at $\sqrt{s_\text {NN}}=200$ GeV to search for the presence of the chiral magnetic effect in collisions of nuclei. The isobar collision species alternated frequently between $_{44}^{96}{\mathrm{Ru}}+_{44}^{96}{\mathrm{Ru}}$ and $_{40}^{96}{\mathrm{Zr}}+_{40}^{96}{\mathrm{Zr}}$ . In order to conduct blind analyses of studies related to the chiral magnetic effect in these isobar data, STAR developed a three-step blind analysis procedure. Analysts are initially provided a “reference sample” of data, comprised of a mix of events from the two species, the order of which respects time-dependent changes in run conditions. After tuning analysis codes and performing time-dependent quality assurance on the reference sample, analysts are provided a species-blind sample suitable for calculating efficiencies and corrections for individual $\approx 30$-min data-taking runs. For this sample, species-specific information is disguised, but individual output files contain data from a single isobar species. Only run-by-run corrections and code alteration subsequent to these corrections are allowed at this stage. Following these modifications, the “frozen” code is passed over the fully un-blind data, completing the blind analysis. As a check of the feasibility of the blind analysis procedure, analysts completed a “mock data challenge,” analyzing data from Au + Au collisions at $\sqrt{s_\text {NN}}=27$ GeV, collected in 2018. The Au + Au data were prepared in the same manner intended for the isobar blind data. Finally, the details of the blind analysis procedure and results from the mock data challenge are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gear Test Assembly - Status Report For FY2019

The final stages of pre-sodium commissioning were completed for the Gear Test Assembly (GTA) in late 2018 and all the components were moved to building 308 for final preparations for insertion into the Mechanisms Engineering Test Loop (METL). The GTA was fully assembled in the experimental test assembly workstation and all supporting electrical and hardware systems were installed on the METL Mezzanine. The GTA was installed in Test Vessel 1 after performing a final systems check, and the vessel and article were raised to operating temperature and held for two weeks to bake-out any moisture present in the components. Test Vessel 1 was filled with sodium and a purification process was completed using the cold trap system. When the sodium was sufficiently clean, Test Vessel 1 was isolated from the rest of METL, and experimental operation of the GTA commenced. The experimental operations consisted of rotating two shafts using Parker servomotors to apply a prototypic torque of a fuel handling mechanism removing and inserting a sodium fast reactor fuel assembly. This removing and inserting motion was repeated until the system seized, indicating component degradation of either the gears or the bearings in the test gearbox. A total of 19,600 cycles were completed, corresponding to the removal and insertion of 9,800 fuel assemblies. The system was shut down and then prepared for removal. The Flexicask System was successfully used to remove the GTA from Test Vessel 1 while keeping both vessel and article inert during the process. The GTA was installed in the Carbonation System, where the process of slowly reacting the sodium away using moist CO 2 has been started. Once the GTA is fully cleaned, it will be disassembled and the gears will undergo the same NDE process performed before testing to quantify the wear that occurred. A report on this, along with the data analysis from the experimental operations will be submitted in late 2019.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dark energy survey internal consistency tests of the joint cosmological probes analysis with posterior predictive distributions

Beyond ΛCDM, physics or systematic errors may cause subsets of a cosmological data set to appear inconsistent when analysed assuming ΛCDM. Here, we present an application of internal consistency tests to measurements from the Dark Energy Survey Year 1 (DES Y1) joint probes analysis. Our analysis relies on computing the posterior predictive distribution (PPD) for these data under the assumption of ΛCDM. We find that the DES Y1 data have an acceptable goodness of fit to ΛCDM, with a probability of finding a worse fit by random chance of p = 0.046. Using numerical PPD tests, supplemented by graphical checks, we show that most of the data vector appears completely consistent with expectations, although we observe a small tension between large- and small-scale measurements. A small part (roughly 1.5 per cent) of the data vector shows an unusually large departure from expectations; excluding this part of the data has negligible impact on cosmological constraints, but does significantly improve the p-value to 0.10. The methodology developed here will be applied to test the consistency of DES Year 3 joint probes data sets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon detector system timing performance in the DUNE 35-ton prototype liquid argon time projection chamber

Here, the 35-ton prototype for the Deep Underground Neutrino Experiment far detector was a single-phase liquid argon time projection chamber with an integrated photon detector system, all situated inside a membrane cryostat. The detector took cosmic-ray data for six weeks during the period of February 1, 2016 to March 12, 2016. The performance of the photon detection system was checked with these data. An installed photon detector was demonstrated to measure the arrival times of cosmic-ray muons with a resolution better than 32 ns, limited by the timing of the trigger system. A measurement of the timing resolution using closely-spaced calibration pulses yielded a resolution of 15 ns for pulses at a level of 6 photo-electrons. Scintillation light from cosmic-ray muons was observed to be attenuated with increasing distance with a characteristic length of $155 \pm 28$ cm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Analytics, Causal Knowledge Acquisition and Reasoning for Technical Language Processing

Complex engineering systems such as nuclear power plants (NPPs) generate and collect large amounts of equipment reliability (ER) data elements that contain information on the status of components, assets, and systems. Some of this information is textual in form and can be found in documents such as incident reports (IRs) and work orders (WOs). Analyses of textual data in current NPPs-using natural language processing (NLP) methods-have been expanded over the last decade, and it is only recently that the true potential of such analyses has emerged. So far, applications of NLP methods have mostly been limited to classification and prediction, the goal being to identify the nature of the textual element (e.g., safety or non-safety related). Here, we target a more complex problem: automatically extracting knowledge from a textual element in order to assist system engineers in conducting system health assessments. Knowledge extraction is a very broad concept, and its definition may vary depending on the application context. Our methods are a blend of both rule-based and machine learning (ML) algorithms. For our purposes, knowledge extraction means identifying the systems or assets mentioned in a given textual element, as well as the type of event described (e.g., component failure or maintenance activity). In addition, we want to capture details such as measured quantities and the temporal/cause-effect relations between events. In this tool, we also demonstrate how textual data elements are preprocessed in order to handle typos, acronyms, and abbreviations. One main feature of these methods is that they are not based solely on data, but are in fact model-based. In other words, they also rely on MBSE models that are designed to capture-from a functional point of view-the architecture of the systems/assets under consideration. The main purpose of such models is to digitally emulate system engineers' knowledge of system and asset architecture and to identify dependencies among systems, assets, and components. Provided these models, analyses of textual and numeric ER data can be performed by first identifying the OPM model elements to which the ER data elements are referring. The relationships between ER data elements are then identified by checking for any temporal or logical dependencies.

Mandelli, Diego [Idaho National Laboratory (INL), ↗

Functional Bounding Content Envelope for Gamma and Neutron Emitting Isotopes in the Model 9977 Packaging

The contents approved for shipment in a Type B radioactive material transportation package have historically been descriptions of discrete items, or groupings of well-defined similar items, in the package safety basis documentation. The need for a comprehensive functional content envelope of both gamma and neutron emitting nuclides compliant with regulatory limits has become necessary as the DOE complex requires shipments of unique mixtures of radionuclides and impurities. Recent publications have presented a calculational model and a corresponding content envelope intended to be compliant with federal regulatory external radiation limits as well as design decay heat limits based on the Model 9977 Packaging. The methodology used to develop this content envelope consisted of determining the external radiation dose rates based on one gram of a given isotope combined, in the case of actinides, with various levels of light element impurities and determining the allowable mass to the regulatory limits based on these dose rates. The method of ratioing from these calculations to the masses that meet the regulatory limits fails in the case of some combinations of actinides and light element impurities because of the effect of subcritical multiplication, resulting in non-conservative and non-compliant dose rates in some cases. This is particularly true for many actinides combined with beryllium, boron, fluorine, lithium, and sodium. In this study, the source was modeled as a sphere with the appropriate dimensions based on the actinide or gamma source density and placed at the bottom of the containment vessel for maximum conservatism. The results presented in this report rectify the above-noted deficiencies by adjusting the previously determined mass limits so that the resulting dose rates are compliant with regulatory limits. Some amount of iteration was required in some instances to adjust the masses for dose compliance. In some instances the masses were increased since they were too conservative. In addition, the method of ratioing the masses when applied to several gamma emitting isotopes also resulted in either non-conservative or overly conservative data. The mass imits presented here are for bare sources and are complaint with the design decay heat limit of 19W. The masses are based on package surface dose rates (the limiting dose rate) that fall in the range 185-195 mrem/h, thus giving an additional margin of between 7.5% and 2.5% to the regulatory limit of 200 mrem/h. This report presents a revised set of mass limits (i.e., content envelope) for several neutron emitting actinides with varying levels of light element impurities compliant with both external radiation and design decay heat limits. In addition, revised limits for gamma sources are also presented. The neutron emitter mass limits are in Tables 1 through 9 and the gamma emitter mass limits are in Table 10. The revised content envelope covering a wide range of materials present in the DOE complex, was developed for the Model 9977 Packaging, providing conservative limits for other commonly-used Type B Packagings such as the Models 9975 and 9978. It should be noted that for the Model 9977 package, shipment is also possible with three shielded containers – lead or tungsten for gamma sources and polyethylene for neutron emitters. The design decay heat limits for these are as follows: 19W for tungsten, 6W for lead and 3W for polyethylene. The limits presented in this report would need to be checked against the lower decay heat limits for the lead and polyethylene and adjusted as required for compliance. Criticality safety is not factored into these limits and should be evaluated on a case by case basis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗