Search NASA⌕ Search

SEARCH · Search NASA

Results for “One”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Internal one-particle density matrix for Bose-Einstein condensates with finite number of particles in a harmonic potential

Investigations on the internal one-particle density matrix in the case of Bose-Einstein condensates with a finite number (N) of particles in a harmonic potential are performed. We solve the eigenvalue problem of the Pethick-Pitaevskii-type internal density matrix and find a fragmented condensate. On the contrary the condensate Jacobi-type internal density matrix gives complete condensation into a single state. The internal one-particle density matrix is, therefore, shown to be different in general for different choices of the internal coordinate system. We propose two physically motivated criteria for the choice of the adequate coordinate systems that give us a unique answer for the internal one-particle density matrix. One criterion is that in the infinite particle number limit (N={infinity}) the internal one-particle density matrix should have the same eigenvalues and eigenfunctions as those of the corresponding ideal Bose-Einstein condensate in the laboratory frame. The other criterion is that the coordinate of the internal one-particle density matrix should be orthogonal to the remaining (N-2) internal coordinates, though the (N-2) coordinates, in general, do not need to be mutually orthogonal. This second criterion is shown to imply the first criterion. It is shown that the internal Jacobi coordinate system satisfies these two criteria while the internal coordinate system adopted by Pethick and Pitaevskii for the construction of the internal one-particle density matrix does not. It is demonstrated that these two criteria uniquely determine the internal one-particle density matrix that is identical to that calculated with the Jacobi coordinates. The relevance of this work concerning {alpha}-particle condensates in nuclei, as well as bosonic atoms in traps, is pointed out.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-173: One-Scan Protocol: Verifying the Delivery of Spot-Scanning Proton Beam

Purpose: Radiochromic film for spot-scanning QA provides high spatial resolution and efficiency gains from one-shot irradiation for multiple depths. However, calibration can be a tedious procedure which may limit widespread use. Moreover, since there may be an energy dependence, which manifests as a depth dependence, this may require additional measurements for each patient. We present a one-scan protocol to simplify the procedure. Methods: We performed the calibration using an EBT3 film at depths of 18, 20, 24cm of Plastic Water exposed by a 6-level step-wedge plan on a Proteus Plus proton system (IBA, Belgium). The calibration doses ranged 65–250 cGy(RBE) for proton energies of 170–200MeV. A clinical prostate+nodes plan was used for validation. The planar doses at selected depths were measured with EBT3 films and analyzed using one-scan protocol (one-scan digitization of QA film and at least one film exposed to known dose). The Gamma passing rates, dose-difference maps, and profiles of 2D planar doses measured with EBT3 film, IBA MatriXX PT, versus TPS calculations were analyzed and compared. Results: The EBT3 film measurement results matched well with the TPS calculation data with an average passing rate of ∼95% for 2%/2mm and slightly lower passing rates were obtained from an ion chamber array detector. We were able to demonstrate that the use of a proton step-wedge provided clinically acceptable results and minimized variations between film-scanner orientation, inter-scan, and scanning conditions. Furthermore, it could be derived from no more than two films exposed to known doses (one could be zero) for rescaling the master calibration curve at each depth. Conclusion: The use of a proton step-wedge for calibration of EBT3 film increases efficiency. The sensitivity of the calibration to depth variations has been explored. One-scan protocol results appear to be comparable to that of the ion chamber array detector. One author has a research grant from Ashland Inc., the manufacturer of the GafChromic film.

60 APPLIED LIFE SCIENCES↗

Comparisons between thermodynamic and one-dimensional combustion models of spark-ignition engines

Results from a one-dimensional combustion model employing a constant eddy diffusivity and a one-step chemical reaction are compared with those of one-zone and two-zone thermodynamic models to study the flame propagation in a spark-ignition engine. One-dimensional model predictions are found to be very sensitive to the eddy diffusivity and reaction rate data. The average mixing temperature found using the one-zone thermodynamic model is higher than those of the two-zone and one-dimensional models during the compression stroke, and that of the one-dimensional model is higher than those predicted by both thermodynamic models during the expansion stroke. The one-dimensional model is shown to predict an accelerating flame even when the front approaches the cold cylinder wall.

Ramos, J. I.↗

rHealth One Demonstration Aboard ISS: A Microfluidic Bioanalyzer Based on Sheath/Hydrodynamic Focusing Flow Cytometry

The Exploration Medical Capability (ExMC) element aims to provide astronauts with the means for their own health monitoring, diagnosis, and treatment during exploration missions. As space flight ventures further from earth, the need for autonomous medical care increases under greater constraints on size, mass, and resources. One pillar for diagnosis that crew would be separated from is laboratory analysis. Even now on ISS, blood samples must be collected and returned to earth for testing. In response, ExMC is assessing how assays for hematology, bone health, radiation exposure etc. could be addressed through commercial-off-the-shelf (COTS) and Small Business Innovation Research (SBIR) funded bioanalyzers that are miniaturizing lab technology. Since missions will reach distances where there are no timely replacements, validation on the International Space Station (ISS) is a necessary part of that assessment. In partnership with NASA Johnson Space Center (JSC) Immunology Lab and the Research Operations and Integration (ROI) element, ExMC conducted a technology demonstration on ISS of the rHEALTH ONE, a flow cytometry based bioanalyzer, to assess future devices based on this design. In flow cytometry, there are predominantly three ways to focus the cells (or particles) into a single file stream: hydrodynamic focusing, microcapillary, and acoustic focusing. The rHEALTH ONE utilizes the commercial standard, sheath-based hydrodynamic focusing. rHEALTH itself represents both a company and a suite of medical tools NASA has funded through SBIR grants towards the development of a promising diagnosis instrument for exploration missions. rHEALTH ONE is the interim version of the technology, functional as a benchtop analyzer and test bed for the next generation of rHEALTH in development. Several modifications were made to the rHEALTH ONE analyzer for operation in microgravity. For function, fluid management was key. A sheath-based analyzer uses sheath fluid to flow the sample, cleaning fluid to prevent biological contamination, and a reservoir to collect the liquid waste. The rHEALTH ONE analyzer uses bottles dependent on gravity to separate the air and liquid pathways and keep the liquids contained. It uses only 1 psig of air pressure to directly push the liquid through the device, requiring little-to-no resistance at inlet and outlet. A microtubing assembly with self-sealing luer connectors was designed – featuring 0.014 mm thick durable medical balloons to hold water inside the supply bottles – to create safe containment and easy access for the crew while maintaining the analyzer’s function. For safety, copper tape was added to the interior of the plastic housing to reduce electromagnetic interference, fluid and electrical connections were secured against vibration and leaks, and gaps were further sealed to ensure containment of the optical block and lasers. Water as the sheath and cleaning fluid and TOX 0 samples were used to reduce the biohazard risk to the crew. In May 2022, European Space Agency astronaut Samantha Cristoforetti demonstrated the rHEALTH ONE aboard ISS for its sample loading, flow cytometry, and data collection capability in microgravity. The JSC Immunology Lab provided flow cytometry expertise, designed the sample test protocol, and manufactured and benchmarked the flight samples on a ‘gold-standard’ flow cytometer. The analyzer was primed with water, purged of air, and four calibration solutions of polystyrene microparticles were tested to characterize its performance. Tightly controlled procedures and excellent execution prevented air bubble interference during air/water separation, fluid transfer, sample mixing and loading. Data showed a slight increase in signal noise on 3 of 5 channels and an anomaly of fluorophores migrating in one sample (confirmed by JSC post-flight). Flight results correctly detected the change in sample, matched the analyzer’s ground performance, and were consistent with the gold-standard’s ground results. Although areas were noted for improvement, these outcomes signified complete mission success.

R. S. Miller↗

System and method for the analysis of one or more compounds and/or species produced by a solution-based nuclear reactor

The present invention relates generally to both a system and method for determining the composition of an off-gas from a solution nuclear reactor (e.g., an Aqueous Homogeneous Reactor (AHR)) and the composition of the fissioning solution from those measurements. In one embodiment, the present invention utilizes at least one quadrupole mass spectrometer (QMS) in a system and/or method designed to determine at least one or more of: (i) the rate of production of at least one gas and/or gas species from a nuclear reactor; (ii) the effect on pH by one or more nitrogen species; (iii) the rate of production of one or more fission gases; and/or (iv) the effect on pH of at least one gas and/or gas species other than one or more nitrogen species from a nuclear reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

One System Overview - 16579

The U.S. Department of Energy (DOE), Office of River Protection (ORP) is responsible for managing and completing the River Protection Project mission, which is to 'safeguard the nuclear waste stored in Hanford's 177 underground tanks, and to manage the waste safely and responsibly until it can be treated in the Waste Treatment and Immobilization Plant for final disposition'. The Office of River Protection's work scope is currently performed through two primary contracts: - The Tank Operations Contract, held by Washington River Protection Solutions LLC, (WRPS) includes the construction, operation, and maintenance activities necessary to safely store, retrieve, and transfer tank wastes; provide supplemental tank waste treatment; provide storage and/or disposal of primary and secondary waste streams; design, construction and commissioning of the Low-Activity Waste Pretreatment System; and support ORP to integrate Hanford Tank Waste Treatment and Immobilization Plant (WTP) completion and startup with Tank Farms operations. - The WTP Contract, held by Bechtel National, Inc. (BNI), includes the design, construction, and commissioning of a Pretreatment Facility, two vitrification facilities (one for high-level waste and one for low-activity waste), a dedicated analytical laboratory, and supporting facilities to treat radioactive tank wastes by immobilizing them into a stable glass waste form. One System was established as a means to improve the integration between the tank farms and the WTP project to support its safe and successful startup. One System's scope and purpose focus on mission integration consistent with DOE's plans to treat tank waste in phases, starting with direct feed of the low-activity waste stream to the WTP's Low-Activity Waste (LAW) Vitrification Facility (referred to as DFLAW). The One System organization now has four major focus areas: - Flowsheet Integration? Integrated River Protection Project (RPP) flowsheet development and management; developing a gaps, risks, and opportunities management plan and technical roadmap; and waste feed qualification. - Mission Analysis and Planning? Strategic planning, system planning, and modeling integration. - WTP Startup, Commissioning, and Operations Integration? Interface Control Document (ICD) management, coordinating facilities startup-to-commissioning-to-operations, contract directives and standards identification, and DFLAW program integration. - Project Integration and Controls? Integrated schedule, metrics/dashboards monitoring, and One System risk register. ORP established the DFLAW Program Office in February 2015 as one of its key performance goals. ORP staff, along with contractor managers, have identified roles and responsibilities for the each of the four major focus areas. One System has established an Executive Council and Governance Board to drive program progress and make decisions on DFLAW. This approach allows appropriate government and contractor senior management involvement in the DFLAW Program. Monthly critical path analysis on the integrated DFLAW schedule is being performed. Interface control documents specific to DFLAW have been developed, and system planning and modeling tools are being used to help define the DFLAW flowsheet. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geology of the One Earth Energy Site

The One Earth Energy site is one of two sites in the Illinois Storage Corridor (ISC) project. The objectives of the ISC project is to accelerate commercial deployment of carbon capture utilization and storage at two individual sites and receive approvals for Underground Injection Control (UIC) Class VI permits for construction at each site. At the One Earth Energy site, an extensive data collection program was undertaken, which included the drilling of a test well (One Earth Energy #1 [OEE #1]), four 2D seismic lines, and a small 3D seismic survey. The OEE #1 well was drilled in 2022 and acquired extensive core, log, and testing data to characterize the subsurface geology of the site. Coring was focused on the storage interval, the Mt. Simon Sandstone, and the confining interval, the Eau Claire Formation. The core and log data were used to evaluate the sedimentology and sequence stratigraphy, as well as to develop the conceptual geologic model. This report includes the geological summaries of the Mt. Simon Sandstone and the Eau Claire Formation. The extensive analysis of the log data is included in the petrophysical section, showing ranges of porosity, estimated pore size, and the mineral content of selected zones in the well. The separate petrographic technical report entitled “Petrographic and Advanced Geologic Characterization Report on One Earth Energy #1 (API# 1211325373)”, report number DOE-UIUC-0031892-04, details thin section point-counting analysis that includes mineralogical and pore space analysis, including grain size analysis, annotated thin section photomicrographs, scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDS), and statistics of grain size analysis on Mt. Simon thin sections from OEE #1. The final OEE #1 well data to be included in this geology report is the routine core analysis of both whole core plugs and rotary sidewall core plugs. In addition to the OEE #1 well, four 2D seismic lines and a small 3D survey were acquired as part of the overall subsurface geological characterization. This geology report references the seismic interpretation report, entitled “One Earth Energy Site Seismic Interpretation Task 5.0”, report number DOE-UIUC-0031892-07. This report details the stratigraphic and structural interpretation of the 2D and 3D seismic data acquired at the One Earth Energy site. The 2D seismic data was acquired in 2019 and 2021, and the 3D survey was acquired in 2022. The objectives of the seismic programs were to contribute to the subsurface characterization of the Mt. Simon-Eau Claire Storage Complex by evaluating the continuity of potential storage reservoirs and containment intervals across the project area, and to determine if any geologic features are present that would increase containment risk to the proposed carbon storage project.

09 BIOMASS FUELS↗

A double copy from twisted (co)homology at genus one

We study the twisted (co)homology of a family of genus-one integrals — the so called Riemann-Wirtinger integrals. These integrals are closely related to one-loop string amplitudes in chiral splitting where one leaves the loop-momentum, modulus and all but one puncture un-integrated. While not actual one-loop string integrals, they share many properties and are simple enough that the associated twisted (co)homologies have been completely characterized [1]. Using intersection numbers — an inner product on the vector space of allowed differential forms — we derive the Gauss-Manin connection for two bases of the twisted cohomology providing an independent check of [2]. We also use the intersection index — an inner product on the vector space of allowed contours — to derive a double-copy formula for the closed-string analogues of Riemann-Wirtinger integrals (one-dimensional integrals over the torus). Similar to the celebrated KLT formula between open- and closed-string tree-level amplitudes, these intersection indices form a genus-one KLT-like kernel defining bilinears in meromorphic Riemann-Wirtinger integrals that are equal to their complex counterparts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

One-norm geometric quantum discord and critical point estimation in the XY spin chain

In contrast with entanglement and quantum discord (QD), we investigate the thermal quantum correlation in terms of Schatten one-norm geometric quantum discord (GQD) in the XY spin chain, and analyze their capabilities in detecting the critical point of quantum phase transition. We show that the one-norm GQD can reveal more properties about quantum correlation between two spins, especially for the long-range quantum correlation at finite temperature. Under the influences of site distance, anisotropy and temperature, one-norm GQD and its first derivative make it possible to detect the critical point efficiently for a general XY spin chain. - Highlights: • Comparing with entanglement and QD, one-norm GQD is more robust versus the temperature. • One-norm GQD is more efficient in characterization of long-range quantum correlation between two distant qubits. • One-norm GQD performs well in highlighting the critical point of QPT at zero or low finite temperature. • One-norm GQD has a number of advantages over QD in detecting the critical point of the spin chain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synthesis, characterization, anticancer evaluation and mechanisms of cytotoxic activity of novel 3-hydroxy-3-pyrrolin-2-ones bearing thenoyl fragment: DNA, BSA interactions and molecular docking study

In order to make a progress in discovering a new agents for chemotherapy with improved properties and bearing in mind the fact that substituted 3-hydroxy-3-pyrrolin-2-ones belong to a class of biologically active compounds, series of novel 1,5-diaryl-4-(2-thienylcarbonyl)-3-hydroxy-3-pyrrolin-2-ones were synthesized and characterized by spectral (UV–Vis, IR, NMR, ESI-MS), X-ray and elemental analysis. All compounds were examined for their cytotoxic effect on human cancer cell lines HeLa and MDA-MB 231 and normal fibroblasts (MRC-5). Four compounds, 3-hydroxy-1-(p-tolyl)-4-(2-thienylcarbonyl)-5-(4-chlorophenyl)-2,5-dihydro-1H-pyrrol-2-one (D10), 3-hydroxy-1-(3-nitrophenyl)-4-(2-thienylcarbonyl)-5-(4-(benzyloxy)phenyl)-2,5-dihydro-1H-pyrrol-2-one (D13), 3-hydroxy-1-(4-nitrophenyl)-4-(2-thienylcarbonyl)-5-(4-(benzyloxy)phenyl)-2,5-dihydro-1H-pyrrol-2-one (D14), and 3-hydroxy-1-(4-chlorophenyl)-4-(2-thienylcarbonyl)-5-(4-(benzyloxy)phenyl)-2,5-dihydro-1H-pyrrol-2-one (D15), that showed the highest cytotoxicity against malignant cells and the best selectivity towards normal cells were selected for further experiments. Results obtained by investigating mechanisms of cytotoxic activity suggest that selected 3-hydroxy-3-pyrrolin-2-one derivatives in HeLa cells induce apoptosis that is associated with S phase arrest (D13, D15, and D10) or unrelated to cell cycle distribution (D14). Additionally, to better understand their suitability for potential use as anticancer medicaments we studied the interactions between biomacromolecules (DNA or BSA) and D13 and D15. The results indicated that D13 and D15 have great affinity to displace EB from the EB-DNA complex through intercalation [K sv = (3.7 ± 0.1) and (3.4 ± 0.1) × 10 3 M -1 , respectively], an intercalative mode also confirmed through viscosity measurements. K a values, obtained as result of fluorescence titration of BSA with D13 and D15 [K a = (4.2 ± 0.2) and (2.6 ± 0.2) × 10 5 M, respectively], support the fact that a significant amount of the tested compounds could be transported and distributed through the cells. In addition, by DNA and BSA molecular docking study for D13, D14 and D15 is determined and predicted the binding mode and the interaction region. © 2019 Elsevier Inc.

60 APPLIED LIFE SCIENCES↗

Prognostic Significance of Number of Positive Nodes: A Long-Term Study of One to Two Nodes Versus Three Nodes in Breast Cancer Patients

Purpose: Previous reports of breast cancer have generally analyzed patients with one to three positive lymph nodes as a single group, often leading to controversy regarding the practical clinical applicability. The present study separately analyzed the survival outcomes of Stage T1-T2 breast cancer patients according to whether one, two, or three axillary nodes were pathologically positive. Methods and Materials: The records of 5,996 patients were available for analysis from the population-based Saskatchewan provincial registry between 1981 and 1995. Because the reliability of the nodal assessment depends on the number of lymph nodes sampled, only those 755 patients with Stage T1-T2 disease and eight or more nodes examined were analyzed further for overall survival and cause-specific survival (CSS). Results: Patients with one and two positive nodes had nearly indistinguishable survival plots, but those with three positive nodes had a distinct trend toward worse survival. The overall survival rate of patients with one, two, and three nodes at 5, 10, and 15 years was 82.7%, 77.0%, and 79.0%, 64.8%, 60.9%, and 52.8%, and 48.8%, 48.0%, and 40.9%, respectively (p = .11). The corresponding CSS rates at 5, 10, and 15 years were 89.4%, 82.0%, and 81.3%, 78.87%, 72.9%, and 62.1%, and 72.7%. 69.0%, and 55.6% (p = .0004). The use of regional radiotherapy did not confer any apparent survival benefit in terms of either overall survival or CSS. Conclusion: Patients with one or two positive nodes had a similar CSS. However, those with three positive nodes fared worse, with a significantly reduced CSS compared with those with one or two involved nodes. Thus, the survival data among patients with one to three nodes positive reveals clearly relevant differences when analyzed separately.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural and electronic properties of free standing one-sided and two-sided hydrogenated silicene: A first principle study

We performed first-principle study of the structural and electronic properties of two-dimensional hydrogenated silicene for two configurations; one is hydrogenation along one side of silicene sheet and second is hydrogenation in both sides of silicene sheet. The one-side hydrogenated silicene is found stable at planar geometry while increased buckling of 0.725 Å is found for both-side hydrogenated silicene. The result shows that the hydrogenation occupy the extended π-bonding network of silicene, and thus it exhibits semi-conducting behaviour with a band gap of 1.77 eV and 2.19 eV for one-side hydrogenated silicene and both-side hydrogenated silicene respectively. However, both-side hydrogenated silicene of binding energy 4.56 eV is more stable than one-side hydrogenated silicene of binding energy 4.30 eV, but experimentally silicene is synthesized on substrates which interacts one side of silicene layer and only other side is available for H-atoms. Therefore, practically one-side hydrogenation is also important.

36 MATERIALS SCIENCE↗

Hydrolysis at One of the Two Nucleotide-binding Sites Drives the Dissociation of ATP-binding Cassette Nucleotide-binding Domain Dimers

The functional unit of ATP-binding cassette (ABC) transporters consists of two transmembrane domains and two nucleotide-binding domains (NBDs). ATP binding elicits association of the two NBDs, forming a dimer in a head-to-tail arrangement, with two nucleotides “sandwiched” at the dimer interface. Each of the two nucleotide-binding sites is formed by residues from the two NBDs. We recently found that the prototypical NBD MJ0796 from Methanocaldococcus jannaschii dimerizes in response to ATP binding and dissociates completely following ATP hydrolysis. However, it is still unknown whether dissociation of NBD dimers follows ATP hydrolysis at one or both nucleotide-binding sites. Here, we used luminescence resonance energy transfer to study heterodimers formed by one active (donor-labeled) and one catalytically defective (acceptor-labeled) NBD. Rapid mixing experiments in a stop-flow chamber showed that NBD heterodimers with one functional and one inactive site dissociated at a rate indistinguishable from that of dimers with two hydrolysis-competent sites. Comparison of the rates of NBD dimer dissociation and ATP hydrolysis indicated that dissociation followed hydrolysis of one ATP. We conclude that ATP hydrolysis at one nucleotide-binding site drives NBD dimer dissociation.

59 BASIC BIOLOGICAL SCIENCES↗

Comparing effective-one-body gravitational waveforms to accurate numerical data

We continue the program of constructing, within the effective-one-body (EOB) approach, high-accuracy, faithful analytic waveforms describing the gravitational wave signal emitted by inspiralling and coalescing binary black holes. We present the comparable-mass version of a new, resummed 3 post-Newtonian (PN) accurate EOB quadrupolar waveform that we recently introduced in the small-mass-ratio limit. We compare the phase and the amplitude of this waveform to the recently published results of a high-accuracy numerical simulation of 15 orbits of an inspiralling equal-mass binary black hole system performed by the Caltech-Cornell group. We find a remarkable agreement, both in phase and in amplitude, between the new EOB waveform and the published numerical data. More precisely: (i) in the gravitational wave (GW) frequency domain M{omega}<0.08 where the phase of one of the nonresummed 'Taylor approximant' (T4) waveform matches well with the numerical relativity one, we find that the EOB phase fares as well, while (ii) for higher GW frequencies, 0.08<M{omega} < or approx. 0.14, where the Taylor T4 approximant starts to significantly diverge from the numerical relativity phase, we show that the EOB phase continues to match well the numerical relativity one. We further propose various methods of tuning the two inspiral flexibility parameters, a{sub 5} and v{sub pole}, of the EOB waveform so as to ''best fit'' EOB predictions to numerical data. We find that the maximal dephasing between EOB and numerical relativity can then be reduced below 10{sup -3} GW cycles over the entire span (30 GW cycles) of the simulation (while, without tuning them, the dephasing is <8x10{sup -3} cycles). In addition, our resummed EOB amplitude agrees much better with the numerical relativity one than any of the previously considered nonresummed, post-Newtonian one (including a recently derived, nonresummed 3 PN-accurate one). We think that the present work, taken in conjunction with other recent works on the EOB-numerical relativity comparison confirms the ability of the EOB formalism (especially in its recently improved avatars) to faithfully capture the 'real' general relativistic waveforms.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cooperative Design of Systems of Systems Against Attack on One Subsystem

Future large-scale control systems will be cyberphysical System of Systems (SoS)s each consisting of many interacting subsystems operating harmoniously and making decisions that benefit the entire enterprise. In terms of accomplishing their own objectives, the subsystems in an SoS will be designed so that their decision-making process achieves a Nash equilibrium for the entire SoS. This equilibrium ensures that no one subsystem can improve its position by deviating from the agreed decision. One of the weaknesses of this equilibrium is that it is vulnerable to cyber-attacks directed towards the objectives of one subsystem. In this paper, we consider an attack on a linear quadratic SoS that consists of altering some parameters in the objective function of one subsystem by injecting negative definite matrices into the attacked subsystem's objective function. Such an attack would be designed to disrupt the operation of the entire SoS by pitting one subsystem against the others and causing a change in the behavior and trajectory of the entire SoS. We consider two possible outcomes of the attack. The first is when the attack is not detected and all subsystems continue to operate as designed but now reaching a different Nash equilibrium that may or may not yield the outcome desired by the attacker. In this case, existence results related to the new Nash equilibrium will be derived. The second is when the attack is detected causing the remaining subsystems to react by forming a cooperative team to counter the actions of the attacked subsystem. The team will then establish a new Nash equilibrium with the attacked subsystem. Both of these possible outcomes of the cyber-attack will be analyzed. A 3-subsystems SoS example illustrating the results will also be presented. This example illustrates the ability of an attacker to drive the SoS's state trajectory away from the origin if the attack on one subsystem is not detected. It also illustrates the advantage that the remaining subsystems have in restoring the trajectory to one that is close to the pre-attack equilibrium trajectory by cooperating as a team if the attack is detected.

Talebi, Shahriar↗

SU-F-J-66: Anatomy Deformation Based Comparison Between One-Step and Two-Step Optimization for Online ART

Purpose: This study investigated that how the quality of adapted plan was affected by inter-fractional anatomy deformation by using one-step and two-step optimization for on line adaptive radiotherapy (ART) procedure. Methods: 10 lung carcinoma patients were chosen randomly to produce IMRT plan by one-step and two-step algorithms respectively, and the prescribed dose was set as 60 Gy on the planning target volume (PTV) for all patients. To simulate inter-fractional target deformation, four specific cases were created by systematic anatomy variation; including target superior shift 0.5 cm, 0.3cm contraction, 0.3 cm expansion and 45-degree rotation. Based on these four anatomy deformation, adapted plan, regenerated plan and non-adapted plan were created to evaluate quality of adaptation. Adapted plans were generated automatically by using one-step and two-step algorithms respectively to optimize original plans, and regenerated plans were manually created by experience physicists. Non-adapted plans were produced by recalculating the dose distribution based on corresponding original plans. The deviations among these three plans were statistically analyzed by paired T-test. Results: In PTV superior shift case, adapted plans had significantly better PTV coverage by using two-step algorithm compared with one-step one, and meanwhile there was a significant difference of V95 by comparison with adapted and non-adapted plans (p=0.0025). In target contraction deformation, with almost same PTV coverage, the total lung received lower dose using one-step algorithm than two-step algorithm (p=0.0143,0.0126 for V20, Dmean respectively). In other two deformation cases, there were no significant differences observed by both two optimized algorithms. Conclusion: In geometry deformation such as target contraction, with comparable PTV coverage, one-step algorithm gave better OAR sparing than two-step algorithm. Reversely, the adaptation by using two-step algorithm had higher efficiency and accuracy as target occurred position displacement. We want to thank Dr. Lei Xing and Dr. Yong Yang in the Stanford University School of Medicine for this work. This work was jointly supported by NSFC (61471226), Natural Science Foundation for Distinguished Young Scholars of Shandong Province (JQ201516), and China Postdoctoral Science Foundation (2015T80739, 2014M551949).

60 APPLIED LIFE SCIENCES↗

Developing and Deploying Universal Diagnostic Platforms for One-Health Biosurveillance

ObjectiveOur goal is to develop deployable strategies for infectious disease diagnosis at the point-of-care that are applicable to multiple hosts of infection - conforming to the global One Health Strategy for diagnostics. We aim to develop methods that do not require prior knowledge of the pathogen in question, and can facilitate rapid and effective decision-making and situational awareness.IntroductionThere is an urgent need for diagnostic strategies for infections which are host-independent, so as to effectively track zoonotic spread, monitor animal carriers of pathogens, and evaluate transmission dynamics. Infection of a host - pathogen or human- by an animal results in recognition by the immune response, which consequently causes release of inflammatory mediators. Many scientists have explored the use of cytokines as diagnostic indicators of disease, but the conserved nature of the immune response in humans and animals results in cross-reactivity among many pathogens, making evaluation of the results difficult, especially in high disease burden populations. Measuring the pathogen-specific signature, however, is advantageous - as it offers discrete identification of active infection, and discrimination from exposure. It also offers a universal strategy that can be applied to human and animal hosts of infection - allowing for One Health Biosurveillance. Achieving this, however, requires the development of a) tailored strategies for the measurement of biochemically disparate pathogen signatures in clinical samples and b) ultra-sensitive detection of such signatures in the host. The sensor team at Los Alamos National Laboratory is working on both of these aspects, and the development of One Health Diagnostic platforms, the focus of the work presented here.MethodsMany of the biomarkers secreted by bacterial pathogens and recognized by innate immune receptors elicit host cytokine responses that are amphiphilic (largely glycolipids, lipoproteins or lipoglycans). Based on such, our team has developed tailored methods – membrane insertion and lipoprotein capture for the capture and detection of these greasy and stealthy molecules in infected blood. Sensitivity and specificity, assay optimization, alinearity associated with lipidic molecules and assay parameter development for biomarkers associated with bacterial pathogens will be presented. Considerations for clinical sampling for amphiphile detection in blood, and clinical study design will be demonstrated. Our team has developed an ultra-sensitive biosensor for detection of biomarkers in complex matrices based on the evanescent field properties of single mode planar optical waveguides. Detection of amphiphilic biomarkers in clinical samples, using the waveguide-based biosensor and tailored methods for the detection of such molecules has allowed for the diagnosis of infection in both human and animals hosts. Herein, we present two examples of the same; 1) diagnosis of tuberculosis in humans, cattle and badgers using pathogen-based diagnostic strategies; and 2) detection of Gram-negative Lipopolysacharides in beef and in patients with Salmonella-induced sepsis.ResultsWe have developed tailored ultra-sensitive waveguide-biosensor assays for the detection of Lipoarabinomannan (and other biomarkers) from Mycobacteria and demonstrated feasibility in blinded clinical studies in humans and cattle, demonstrating one -health compatibility.We have also demonstrated detection of lipopolysacharides from eight different serotypes of Shiga-toxin carrying E. coli in beef, and Salmonella Typhimurium in pediatric patients using the same approach.ConclusionsWe have demonstrated clinical feasibility of a One Health Strategy for point-of-care diagnostics of bacterial infections in blood for tuberculosis and Gram-negative pathogens in clinical samples. The results will be demonstrated with several discussion points on the consideration of unconventional biochemistry of pathogens for diagnostics, factors influencing point-of-care deployment and integration of diagnostic platforms for biosurveillance. One Health Considerations and challenges therein will also merit discussion.ReferencesSakamuri, R; et al. Accurate Tracking of Bovine Tuberculosis Biomarkers in Infected Cattle using a Novel Biomarker Capture Strategy, Analytical Sciences, 33(4): 457-460, 2017.Noormohammed A et al. Detection of Salmonella LPS in Patient blood by Lipoprotein Capture. Proc. SPIE 10072, Optical Diagnostics and Sensing XVII: Toward Point-of-Care Diagnostics, 100720A , 2017. doi:10.1117/12.2253506Stromberg L et al. Membrane Insertion for the Detection of Lipopolysaccharides: Exploring the Dynamics of Amphiphile-in-Lipid Assays, PloS One, April 2016.Sakamuri RM et al. Association of lipoarabinomannan with high density lipoprotein in blood: implications for diagnostics.Tuberculosis (Edinb). 2013 May;93(3):301-7. doi: 10.1016/j.tube.2013.02.015. Epub 2013 Mar 16Mukundan H et al. Understanding the interaction of Lipoarabinomannan with membrane mimetic architectures. Tuberculosis, 92(1) 32-47, 2012.Mukundan H et al., Waveguide-based Sensors for Pathogen Detection, Invited Review, Sensors, 9(7), 5783-5809.

Mukundan, Harshini↗

Design and initial testing of a one-bladed 30-meter-diameter rotor on the NASA/DOE mod-O wind turbine

The concept of a one-bladed horizontal-axis wind turbine has been of interest to wind turbine designers for many years. Many designs and economic analyses of one-bladed wind turbines have been undertaken by both United States and European wind energy groups. The analyses indicate significant economic advantages but at the same time, significant dynamic response concerns. In an effort to develop a broad data base on wind turbine design and operations, the NASA Wind Energy Project Office has tested a one-bladed rotor at the NASA/DOE Mod-O Wind Turbine Facility. This is the only known test on an intermediate-sized one-bladed rotor in the United States. The 15.2-meter-radius rotor consists of a tip-controlled blade and a counterweight assembly. A rigorous test series was conducted in the Fall of 1985 to collect data on rotor performance, drive train/generator dynamics, structural dynamics, and structural loads. This report includes background information on one-bladed rotor concepts, and Mod-O one-bladed rotor test configuration, supporting design analysis, the Mod-O one-blade rotor test plan, and preliminary test results.

Corrigan, R. D.↗